Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 85
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Neurosurg Rev ; 46(1): 163, 2023 Jul 04.
Article in English | MEDLINE | ID: mdl-37402894

ABSTRACT

OBJECTIVE: Proton beam therapy is considered, by some authors, as having the advantage of delivering dose distributions more conformal to target compared with stereotactic radiosurgery (SRS). Here, we performed a systematic review and meta-analysis of proton beam for VSs, evaluating tumor control and cranial nerve preservation rates, particularly with regard to facial and hearing preservation. METHODS: We reviewed, using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) articles published between 1968 and September 30, 2022. We retained 8 studies reporting 587 patients. RESULTS: Overall rate of tumor control (both stability and decrease in volume) was 95.4% (range 93.5-97.2%, p heterogeneity= 0.77, p<0.001). Overall rate of tumor progression was 4.6% (range 2.8-6.5%, p heterogeneity < 0.77, p<0.001). Overall rate of trigeminal nerve preservation (absence of numbness) was 95.6% (range 93.5-97.7%, I2 = 11.44%, p heterogeneity= 0.34, p<0.001). Overall rate of facial nerve preservation was 93.7% (range 89.6-97.7%, I2 = 76.27%, p heterogeneity<0.001, p<0.001). Overall rate of hearing preservation was 40.6% (range 29.4-51.8%, I2 = 43.36%, p heterogeneity= 0.1, p<0.001). CONCLUSION: Proton beam therapy for VSs achieves high tumor control rates, as high as 95.4%. Facial rate preservation overall rates are 93%, which is lower compared to the most SRS series. Compared with most currently reported SRS techniques, proton beam radiation therapy for VSs does not offer an advantage for facial and hearing preservation compared to most of the currently reported SRS series.


Subject(s)
Neuroma, Acoustic , Proton Therapy , Radiosurgery , Humans , Neuroma, Acoustic/radiotherapy , Neuroma, Acoustic/surgery , Neuroma, Acoustic/pathology , Hearing , Cranial Nerves , Facial Nerve/pathology , Radiosurgery/methods , Treatment Outcome , Follow-Up Studies , Retrospective Studies
2.
Acta Oncol ; 61(2): 206-214, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34686122

ABSTRACT

BACKGROUND: Clinical data suggest that the relative biological effectiveness (RBE) in proton therapy (PT) varies with linear energy transfer (LET). However, LET calculations are neither standardized nor available in clinical routine. Here, the status of LET calculations among European PT institutions and their comparability are assessed. MATERIALS AND METHODS: Eight European PT institutions used suitable treatment planning systems with their center-specific beam model to create treatment plans in a water phantom covering different field arrangements and fulfilling commonly agreed dose objectives. They employed their locally established LET simulation environments and procedures to determine the corresponding LET distributions. Dose distributions D1.1 and DRBE assuming constant and variable RBE, respectively, and LET were compared among the institutions. Inter-center variability was assessed based on dose- and LET-volume-histogram parameters. RESULTS: Treatment plans from six institutions fulfilled all clinical goals and were eligible for common analysis. D1.1 distributions in the target volume were comparable among PT institutions. However, corresponding LET values varied substantially between institutions for all field arrangements, primarily due to differences in LET averaging technique and considered secondary particle spectra. Consequently, DRBE using non-harmonized LET calculations increased inter-center dose variations substantially compared to D1.1 and significantly in mean dose to the target volume of perpendicular and opposing field arrangements (p < 0.05). Harmonizing LET reporting (dose-averaging, all protons, LET to water or to unit density tissue) reduced the inter-center variability in LET to the order of 10-15% within and outside the target volume for all beam arrangements. Consequentially, inter-institutional variability in DRBE decreased to that observed for D1.1. CONCLUSION: Harmonizing the reported LET among PT centers is feasible and allows for consistent multi-centric analysis and reporting of tumor control and toxicity in view of a variable RBE. It may serve as basis for harmonized variable RBE dose prescription in PT.


Subject(s)
Linear Energy Transfer , Proton Therapy , Humans , Monte Carlo Method , Protons , Radiotherapy Planning, Computer-Assisted , Relative Biological Effectiveness
3.
Adv Exp Med Biol ; 1269: 185-190, 2021.
Article in English | MEDLINE | ID: mdl-33966215

ABSTRACT

In radiotherapy, hypoxia is a known negative factor, occurring especially in solid malignant tumours. Nitroimidazole-based positron emission tomography (PET) tracers, due to their selective binding to hypoxic cells, could be used as surrogates to image and quantify the underlying oxygen distributions in tissues. The spatial resolution of a clinical PET image, however, is much larger than the cellular spatial scale where hypoxia occurs. A question therefore arises regarding the possibility of quantifying different hypoxia levels based on PET images, and the aim of the present study is the prescription of corresponding therapeutic doses and its exploration.A tumour oxygenation model was created consisting of two concentric spheres with different oxygen partial pressure (pO2) distributions. In order to mimic a PET image of the simulated tumour, given the relation between uptake and pO2, fundamental effects that limit spatial resolution in a PET imaging system were considered: the uptake distribution was processed with a Gaussian 3D filter, and a re-binning to reach a typical PET image voxel size was performed. Prescription doses to overcome tumour hypoxia and predicted tumour control probability (TCP) were calculated based on the processed images for several fractionation schemes. Knowing the underlying oxygenation at microscopic scale, the actual TCP expected after the delivery of the calculated prescription doses was evaluated. Results are presented for three different dose painting strategies: by numbers, by contours and by using a voxel grouping-based approach.The differences between predicted TCP and evaluated TCP indicate that careful consideration must be taken on the dose prescription strategy and the selection of the number of fractions, depending on the severity of hypoxia.


Subject(s)
Neoplasms , Humans , Neoplasms/diagnostic imaging , Oxygen , Partial Pressure , Positron-Emission Tomography , Probability
4.
Acta Oncol ; 59(10): 1151-1156, 2020 Oct.
Article in English | MEDLINE | ID: mdl-33000988

ABSTRACT

BACKGROUND: This paper presents an insight into the critical discussions and the current strategies of the Nordic countries for handling the variable proton relative biological effectiveness (RBE) as presented at The Nordic Collaborative Workshop for Particle Therapy that took place at the Skandion Clinic on 14th and 15th of November 2019. MATERIAL AND METHODS: In the current clinical practice at the two proton centres in operation at the date, Skandion Clinic, and the Danish Centre for Particle Therapy, a constant proton RBE of 1.1 is applied. The potentially increased effectiveness at the end of the particle range is however considered at the stage of treatment planning at both places based on empirical observations and knowledge. More elaborated strategies to evaluate the plans and mitigate the problem are intensely investigated internationally as well at the two centres. They involve the calculation of the dose-averaged linear energy transfer (LETd) values and the assessment of their distributions corroborated with the distribution of the dose and the location of the critical clinical structures. RESULTS: Methods and tools for LETd calculations are under different stages of development as well as models to account for the variation of the RBE with LETd, dose per fraction, and type of tissue. The way they are currently used for evaluation and optimisation of the plans and their robustness are summarised. A critical but not exhaustive discussion of their potential future implementation in the clinical practice is also presented. CONCLUSIONS: The need for collaboration between the clinical proton centres in establishing common platforms and perspectives for treatment planning evaluation and optimisation is highlighted as well as the need of close interaction with the research academic groups that could offer a complementary perspective and actively help developing methods and tools for clinical implementation of the more complex metrics for considering the variable effectiveness of the proton beams.


Subject(s)
Neoplasms/radiotherapy , Proton Therapy , Humans , Internationality , Radiotherapy Planning, Computer-Assisted , Relative Biological Effectiveness , Scandinavian and Nordic Countries
5.
Acta Oncol ; 57(4): 485-490, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29141489

ABSTRACT

BACKGROUND: Tumour hypoxia is associated with increased radioresistance and poor response to radiotherapy. Pre-treatment assessment of tumour oxygenation could therefore give the possibility to tailor the treatment by calculating the required boost dose needed to overcome the increased radioresistance in hypoxic tumours. This study concerned the derivation of a non-linear conversion function between the uptake of the hypoxia-PET tracer 18F-HX4 and oxygen partial pressure (pO2). MATERIAL AND METHODS: Building on previous experience with FMISO including experimental data on tracer uptake and pO2, tracer-specific model parameters were derived for converting the normalised HX4-uptake at the optimal imaging time point to pO2. The conversion function was implemented in a Python-based computational platform utilising the scripting and the registration modules of the treatment planning system RayStation. Subsequently, the conversion function was applied to determine the pO2 in eight non-small-cell lung cancer (NSCLC) patients imaged with HX4-PET before the start of radiotherapy. Automatic segmentation of hypoxic target volumes (HTVs) was then performed using thresholds around 10 mmHg. The HTVs were compared to sub-volumes segmented based on a tumour-to-blood ratio (TBR) of 1.4 using the aortic arch as the reference oxygenated region. The boost dose required to achieve 95% local control was then calculated based on the calibrated levels of hypoxia, assuming inter-fraction reoxygenation due to changes in acute hypoxia but no overall improvement of the oxygenation status. RESULTS: Using the developed conversion tool, HTVs could be obtained using pO2 a threshold of 10 mmHg which were in agreement with the TBR segmentation. The dose levels required to the HTVs to achieve local control were feasible, being around 70-80 Gy in 24 fractions. CONCLUSIONS: Non-linear conversion of tracer uptake to pO2 in NSCLC imaged with HX4-PET allows a quantitative determination of the dose-boost needed to achieve a high probability of local control.


Subject(s)
Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Imidazoles , Lung Neoplasms/diagnostic imaging , Radiotherapy Planning, Computer-Assisted/methods , Triazoles , Tumor Hypoxia , Carcinoma, Non-Small-Cell Lung/radiotherapy , Fluorine Radioisotopes , Humans , Lung Neoplasms/radiotherapy , Positron-Emission Tomography/methods , Radiopharmaceuticals
6.
Adv Exp Med Biol ; 1072: 183-187, 2018.
Article in English | MEDLINE | ID: mdl-30178343

ABSTRACT

The progress in functional imaging and dose delivery has opened the possibility of targeting tumour hypoxia with radiotherapy. Advanced approaches apply quantitative information on tumour oxygenation retrieved from imaging in dose prescription. These do not, however, take into account the potential difference in radiosensitivity of chronically and acutely hypoxic cells. It was the aim of this study to evaluate the implications of assuming the same or different sensitivities for the hypoxic cells. An in silico 3D-model of a hypoxic tumour with heterogeneous oxygenation was used to model the probabilities of tumour control with different radiotherapy regimens. The results show that by taking into account the potential lower radioresistance of chronically hypoxic cells deprived of oxygen and nutrients, the total dose required to achieve a certain level of control is substantially reduced for a given fractionation scheme in comparison to the case when chronically and acutely hypoxic cells are assumed to have similar features. The results also suggest that the presence of chronic hypoxia could explain the success of radiotherapy for some hypoxic tumours. Given the implications for clinical dose escalation trials, further exploration of the influence of the different forms of hypoxia on treatment outcome is therefore warranted.


Subject(s)
Computer Simulation , Neoplasms/radiotherapy , Radiation Tolerance/physiology , Tumor Hypoxia/physiology , Dose Fractionation, Radiation , Humans , Radiotherapy Dosage
7.
Adv Exp Med Biol ; 1072: 195-200, 2018.
Article in English | MEDLINE | ID: mdl-30178345

ABSTRACT

Functional imaging of tumour hypoxia has been suggested as a tool for refining target definition and treatment optimization in radiotherapy. The approach, however, has been slow to be adopted clinically as most of the studies on the topic do not take into account the in-treatment changes of hypoxia. The present study aimed to introduce a function that quantifies the changes of oxygen distributions in repeated PET images taken during treatment. The proposed approach for determining the reoxygenation function was tested for feasibility on patients with head and neck cancer, repeatedly imaged with FMISO PET during radiotherapy. Reoxygenation functions were derived by solving the convolution between functions describing the oxygen distributions of successive images. The method was found to be mathematically feasible. The results indicate that the reoxygenation functions describing the change in oxygenation have distinct shapes prompting the hypothesis that oxygenation changes reflected by them might have predictive power for treatment outcome. Future studies on a larger patient population to search for predictive correlations based on the reoxygenation function are planned.


Subject(s)
Head and Neck Neoplasms/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Models, Theoretical , Positron-Emission Tomography/methods , Tumor Hypoxia/physiology , Head and Neck Neoplasms/pathology , Humans , Misonidazole/analogs & derivatives
9.
Acta Oncol ; 56(8): 1072-1080, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28281359

ABSTRACT

BACKGROUND: The majority of breast cancer patients who receive radiation treatment are affected by acute radiation-induced skin changes. The assessment of these changes is usually done by subjective methods, which complicates the comparison between different treatments or patient groups. This study investigates the feasibility of new robust methods for monitoring skin microcirculation to objectively assess and quantify acute skin reactions during radiation treatment. MATERIAL AND METHODS: Laser Doppler flowmetry, laser speckle contrast imaging, and polarized light spectroscopy imaging were used to measure radiation-induced changes in microvascular perfusion and red blood cell concentration (RBC) in the skin of 15 patients undergoing adjuvant radiation therapy for breast cancer. Measurements were made before treatment, once a week during treatment, and directly after the last fraction. RESULTS: In the treated breast, perfusion and RBC concentration were increased after 1-5 fractions (2.66-13.3 Gy) compared to baseline. The largest effects were seen in the areola and the medial area. No changes in perfusion and RBC concentration were seen in the untreated breast. In contrast, Radiation Therapy Oncology Group (RTOG) scores were increased only after 2 weeks of treatment, which demonstrates the potential of the proposed methods for early assessment of skin changes. Also, there was a moderate to good correlation between the perfusion (r = 0.52) and RBC concentration (r = 0.59) and the RTOG score given a week later. CONCLUSION: We conclude that radiation-induced microvascular changes in the skin can be objectively measured using novel camera-based techniques before visual changes in the skin are apparent. Objective measurement of microvascular changes in the skin may be valuable in the comparison of skin reactions between different radiation treatments and possibly in predicting acute skin effects at an earlier stage.


Subject(s)
Breast Neoplasms/radiotherapy , Laser-Doppler Flowmetry/methods , Microcirculation , Skin/blood supply , Adult , Aged , Female , Humans , Image Processing, Computer-Assisted/methods , Middle Aged , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated/methods , Skin/radiation effects
10.
Acta Oncol ; 56(11): 1428-1436, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28826308

ABSTRACT

BACKGROUND: Proton breast radiotherapy has been suggested to improve target coverage as well as reduce cardiopulmonary and integral dose compared with photon therapy. This study aims to assess this potential when accounting for breathing motion and a variable relative biological effectiveness (RBE). METHODS: Photon and robustly optimized proton plans were generated to deliver 50 Gy (RBE) in 25 fractions (RBE = 1.1) to the CTV (whole left breast) for 12 patients. The plan evaluation was performed using the constant RBE and a variable RBE model. Robustness against breathing motion, setup, range and RBE uncertainties was analyzed using CT data obtained at free-breathing, breath-hold-at-inhalation and breath-hold-at-exhalation. RESULTS: All photon and proton plans (RBE = 1.1) met the clinical goals. The variable RBE model predicted an average RBE of 1.18 for the CTVs (range 1.14-1.21) and even higher RBEs in organs at risk (OARs). However, the dosimetric impact of this latter aspect was minor due to low OAR doses. The normal tissue complication probability (NTCP) for the lungs was low for all patients (<1%), and similar for photons and protons. The proton plans were generally considered robust for all patients. However, in the most extreme scenarios, the lowest dose received by 98% of the CTV dropped from 96 to 99% of the prescribed dose to around 92-94% for both protons and photons. Including RBE uncertainties in the robustness analysis resulted in substantially higher worst-case OAR doses. CONCLUSIONS: Breathing motion seems to have a minor effect on the plan quality for breast cancer. The variable RBE might impact the potential benefit of protons, but could probably be neglected in most cases where the physical OAR doses are low. However, to be able to identify outlier cases at risk for high OAR doses, the biological evaluation of proton plans taking into account the variable RBE is recommended.


Subject(s)
Movement , Organs at Risk/radiation effects , Proton Therapy , Radiotherapy Planning, Computer-Assisted/methods , Relative Biological Effectiveness , Respiration , Unilateral Breast Neoplasms/radiotherapy , Dose-Response Relationship, Radiation , Female , Humans , Linear Energy Transfer
11.
Acta Oncol ; 56(6): 819-825, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28464740

ABSTRACT

BACKGROUND: Hypoxia imaged by positron emission tomography (PET) is a potential target for optimization in radiotherapy. However, the implementation of this approach with respect to the conversion of intensities in the images into oxygenation and radiosensitivity maps is not straightforward. This study investigated the feasibility of applying two conversion approaches previously derived for 18F-labeled fluoromisonidazole (18F-FMISO)-PET images for the hypoxia tracer 18F-flortanidazole (18F-HX4). MATERIAL AND METHODS: Ten non-small-cell lung cancer patients imaged with 18F-HX4 before the start of radiotherapy were considered in this study. PET image uptake was normalized to a well-oxygenated reference region and subsequently linear and non-linear conversions were used to determine tissue oxygenations maps. These were subsequently used to delineate hypoxic volumes based partial oxygen pressure (pO2) thresholds. The results were compared to hypoxic volumes segmented using a tissue-to-background ratio of 1.4 for 18F-HX4 uptake. RESULTS: While the linear conversion function was not found to result in realistic oxygenation maps, the non-linear function resulted in reasonably sized sub-volumes in good agreement with uptake-based segmented volumes for a limited range of pO2 thresholds. However, the pO2 values corresponding to this range were significantly higher than what is normally considered as hypoxia. The similarity in size, shape, and relative location between uptake-based sub-volumes and volumes based on the conversion to pO2 suggests that the relationship between uptake and pO2 is similar for 18F-FMISO and 18F-HX4, but that the model parameters need to be adjusted for the latter. CONCLUSIONS: A non-linear conversion function between uptake and oxygen partial pressure for 18F-FMISO-PET could be applied to 18F-HX4 images to delineate hypoxic sub-volumes of similar size, shape, and relative location as based directly on the uptake. In order to apply the model for e.g., dose-painting, new parameters need to be derived for the accurate calculation of dose-modifying factors for this tracer.


Subject(s)
Aorta/pathology , Carcinoma, Non-Small-Cell Lung/pathology , Hypoxia/pathology , Lung Neoplasms/pathology , Muscles/pathology , Positron-Emission Tomography/methods , Radiotherapy, Image-Guided/methods , Aorta/diagnostic imaging , Aorta/radiation effects , Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Carcinoma, Non-Small-Cell Lung/radiotherapy , Fluorodeoxyglucose F18 , Humans , Hypoxia/diagnostic imaging , Hypoxia/radiotherapy , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy , Muscles/diagnostic imaging , Muscles/radiation effects , Radiopharmaceuticals , Radiotherapy Dosage , Reference Standards
12.
Acta Oncol ; 55(5): 577-83, 2016 May.
Article in English | MEDLINE | ID: mdl-27027913

ABSTRACT

Background Respiratory gating and proton therapy have both been proposed to reduce the cardiopulmonary burden in breast cancer radiotherapy. This study aims to investigate the additional benefit of proton radiotherapy for breast cancer with and without respiratory gating. Material and methods Twenty left-sided patients were planned on computed tomography (CT)-datasets acquired during enhanced inspiration gating (EIG) and free-breathing (FB), using photon three-dimensional conformal radiation therapy (3D-CRT) and scanned proton beams. Ten patients received treatment to the whole breast only (WBO) and 10 were treated to the breast and the regional lymph nodes (BRN). Dosimetric parameters characterizing the coverage of target volumes and the cardiopulmonary burden were compared using a paired, two-tailed Student's t-test. Results Protons ensured comparable or better target coverage than photons in all patients during both EIG and FB. The heterogeneity index decreased from 12% with photons to about 5% with protons. The mean dose to the ipsilateral lung was reduced in BRN patients from 12 Gy to 7 Gy (RBE) in EIG and from 14 Gy to 6-7 Gy (RBE) in FB, while for WBO patients all values were about 5-6 Gy (RBE). The mean dose to heart decreased by a factor of four in WBO patients [from 1.1 Gy to 0.3 Gy (RBE) in EIG and from 2.1 Gy to 0.5 Gy (RBE) in FB] and 10 in BRN patients [from 2.1 Gy to 0.2 Gy (RBE) in EIG and from 3.4 Gy to 0.3 Gy (RBE) in FB]. Similarly, the mean and the near maximum dose to the left anterior descending artery (LAD) were significantly lower (p < 0.05) with protons in comparison with photons. Conclusion Proton spot scanning has a high potential to reduce the irradiation of organs at risk and other normal tissues for most patients, beyond what could be achieved with EIG and photon therapy. The largest dose sparing has been seen for BRN patients, both in terms of cardiopulmonary burden and integral dose.


Subject(s)
Breast Neoplasms/radiotherapy , Photons/therapeutic use , Proton Therapy/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Adjuvant/methods , Radiotherapy, Conformal/methods , Breast Neoplasms/surgery , Female , Heart/radiation effects , Humans , Inhalation , Lung/radiation effects , Lymph Nodes/radiation effects , Organs at Risk/radiation effects , Patient Positioning/methods , Radiotherapy Dosage , Respiration , Tomography, X-Ray Computed
13.
Acta Oncol ; 54(9): 1592-8, 2015.
Article in English | MEDLINE | ID: mdl-26217986

ABSTRACT

BACKGROUND: Conventionally fractionated radiotherapy (CFRT) has proven ineffective in treating non-small cell lung cancer while more promising results have been obtained with stereotactic body radiotherapy (SBRT). Hypoxic tumours, however, might present a challenge to extremely hypofractionated schedules due to the decreased possibility for inter-fraction fast reoxygenation. A potentially successful compromise might be found in schedules employing several fractions of varying fractional doses. In this modelling study, a wide range of fractionation schedules from single-fraction treatments to heterogeneous, multifraction schedules taking into account repair, repopulation, reoxygenation and radiosensitivity of the tumour cells, has been explored with respect to the probability of controlling lung tumours. MATERIAL AND METHODS: The response to radiation of tumours with heterogeneous spatial and temporal oxygenation was simulated including the effects of accelerated repopulation and intra-fraction repair. Various treatments with respect to time, dose and fractionation were considered and the outcome was estimated as Poisson-based tumour control probability for local control. RESULTS: For well oxygenated tumours, heterogeneous fractionation could increase local control while hypoxic tumours are not efficiently targeted by such treatments despite reoxygenation. For hypofractionated treatments employing large doses per fraction, a synergistic effect was observed between intra-fraction repair and inter-fraction fast reoxygenation of the hypoxic cells as demonstrated by a reduction in D50 from 53.3 Gy for 2 fractions to 52.7 Gy for 5 fractions. CONCLUSIONS: For well oxygenated tumours, heterogeneous fractionation schedules could increase local control rates substantially compared to CFRT. For hypoxic tumours, SBRT-like hypofractionated schedules might be optimal despite the increased risk of intra-fraction repair due to a synergistic effect with inter-fraction reoxygenation.


Subject(s)
Carcinoma, Non-Small-Cell Lung/radiotherapy , Lung Neoplasms/radiotherapy , Models, Biological , Oxygen Consumption , Carcinoma, Non-Small-Cell Lung/physiopathology , Cell Hypoxia , Computer Simulation , Humans , Lung Neoplasms/physiopathology , Oxygen/metabolism , Radiation Dose Hypofractionation , Radiation Tolerance
14.
Acta Oncol ; 53(8): 1041-7, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24983652

ABSTRACT

BACKGROUND: Intensity-modulated radiation therapy (IMRT) has been increasingly employed for treating head and neck (H&N) tumours due to its ability to produce isodoses suitable for the complex anatomy of the region. The aim of this study was to assess possible differences between IMRT and conformal radiation therapy (CRT) with regard to risk of radiation-induced secondary malignancies for H&N tumours. MATERIAL AND METHODS: IMRT and CRT plans were made for 10 H&N adult patients and the resulting treatment planning data were used to calculate the risk of radiation-induced malignancies in four different tissues. Three risk models with biologically relevant parameters were used for calculations. The influence of scatter radiation and repeated imaging sessions has also been investigated. RESULTS: The results showed that the total lifetime risks of developing radiation-induced secondary malignancies from the two treatment techniques, CRT and IMRT, were comparable and in the interval 0.9-2.5%. The risk contributions from the primary beam and scatter radiation were comparable, whereas the contribution from repeated diagnostic imaging was considerably smaller. CONCLUSION: The results indicated that the redistribution of the dose characteristic to IMRT leads to a redistribution of the risks in individual tissues. However, the total levels of risk were similar between the two irradiation techniques considered.


Subject(s)
Head and Neck Neoplasms/radiotherapy , Neoplasms, Radiation-Induced/etiology , Neoplasms, Second Primary/etiology , Radiotherapy, Conformal/adverse effects , Radiotherapy, Intensity-Modulated/adverse effects , Adult , Algorithms , Diagnostic Imaging/adverse effects , Esophagus/radiation effects , Female , Humans , Hypopharyngeal Neoplasms/radiotherapy , Lung/radiation effects , Male , Organs at Risk/radiation effects , Parotid Gland/radiation effects , Phantoms, Imaging , Photons/therapeutic use , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Radiotherapy, Image-Guided/adverse effects , Radiotherapy, Image-Guided/methods , Radiotherapy, Intensity-Modulated/methods , Risk , Scattering, Radiation , Sex Factors , Tongue Neoplasms/radiotherapy , Tonsillar Neoplasms/radiotherapy
15.
Acta Oncol ; 53(8): 1035-40, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24957551

ABSTRACT

BACKGROUND: The validity of the linear-quadratic (LQ) model at high doses has been questioned due to a decreasing agreement between predicted survival and experimental cell survival data. A frequently proposed alternative is the universal survival curve (USC) model, thought to provide a better fit in the high-dose region. The comparison between the predictions of the models has mostly been performed for uniform populations of cells with respect to sensitivity to radiation. This study aimed to compare the two models in terms of cell survival and tumour control probability (TCP) for cell populations with mixed sensitivities related to their oxygenation. METHODS: The study was performed in two parts. For the first part, cell survival curves were calculated with both models assuming various homogeneous populations of cells irradiated with uniform doses. For the second part, a realistic three-dimensional (3D) model of complex tumour oxygenation was used to study the impact of the differences in cell survival on the modelled TCP. Cellular response was assessed with the LQ and USC models at voxel level and a Poisson TCP model at tumour level. RESULTS: For hypoxic tumours, the disputed continuous bend of the LQ survival curve was counteracted by the increased radioresistance of the hypoxic cells and the survival curves started to diverge only at much higher doses than for oxic tumours. This was also reflected by the TCP curves for hypoxic tumours for which the difference in D50 values for the LQ and USC models was reduced from 5.4 to 0.2 Gy for 1 and 3 fractions, respectively, in a tumour with only 1.1% hypoxia and from 9.5 to 0.4 Gy in a tumour with 11.1% hypoxia. CONCLUSIONS: For a large range of fractional doses including hypofractionated schemes, the difference in predicted survival and TCP between the LQ and USC models for tumours with heterogeneous oxygenation was found to be negligible.


Subject(s)
Cell Hypoxia/radiation effects , Cell Survival/radiation effects , Models, Biological , Neoplasms/radiotherapy , Oxygen Consumption/physiology , Radiation Tolerance/physiology , Algorithms , Cell Hypoxia/physiology , Cell Survival/physiology , Dose Fractionation, Radiation , Linear Models , Neoplasms/physiopathology , Neoplasms/surgery , Poisson Distribution , Probability , Radiosurgery
16.
Adv Exp Med Biol ; 812: 143-148, 2014.
Article in English | MEDLINE | ID: mdl-24729226

ABSTRACT

Tumour oxygenation is an important determinant of radiotherapy outcome as it could modulate cellular radiation sensitivity. Advanced PET imaging able to characterise this microenvironmental aspect in vivo might be used to devise counteracting therapies as it could provide information on the severity and the spatial distribution of the hypoxic regions. This study reviews the advantages and limitations of PET for imaging and quantifying tumour hypoxia and proposes a novel approach to obtain absolute levels of hypoxia from PET images through the use of EPR oximetry. This would offer a significant advantage over proposals based on empirical conversions of the intensities in the PET images to relative radiosensitivities. Thus, tumour hypoxia must be taken into account at the stage of treatment planning for photons and particle therapy by accounting for its extent and severity through the use of PET imaging combined with absolute EPR measurements.


Subject(s)
Hypoxia/metabolism , Neoplasms/radiotherapy , Calibration , Electron Spin Resonance Spectroscopy/methods , Humans , Neoplasms/metabolism , Positron-Emission Tomography
17.
Phys Med ; 123: 103427, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38959576

ABSTRACT

BACKGROUND: Reirradiation of head and neck cancer (HNC) became more accessible in the last decade, owing to modern irradiation techniques which offer a reduction in treatment related toxicities. The aim of this paper was to comparatively evaluate the dosimetric aspects derived from intensity modulated photon vs. proton treatment planning in reirradiated HNC patients. METHODS: Six recurrent HNC patients were enrolled in this retrospective study. For each patient two treatment plans were created: one IMRT/VMAT and one IMPT plan. The prescribed dose for the second irradiation was between 50 and 70 Gy RBE. The study comparatively analyzed the CTV coverage, doses to organs at risk (OARs) and low doses received by the healthy tissue (other than OAR). RESULTS: Similar CTV coverage was achieved for photon vs proton plans, with the latter presenting better homogeneity in four cases. Maximum dose to CTV was generally higher for photon plans, with differences ranging from 0.3 to 1.9%. For parotid glands and body, the mean dose was lower for proton plans. A notable reduction of low dose to healthy tissue (other than OARs) could be achieved with protons, with an average of 60% and 64% for D10% and Dmean, respectively. CONCLUSION: The dosimetric comparison between photon and proton reirradiation of HNC showed a great need for treatment individualization, concluding that protons should be considered for reirradiation on an individual basis.


Subject(s)
Head and Neck Neoplasms , Organs at Risk , Photons , Proton Therapy , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Re-Irradiation , Humans , Head and Neck Neoplasms/radiotherapy , Proton Therapy/methods , Photons/therapeutic use , Radiotherapy, Intensity-Modulated/methods , Re-Irradiation/methods , Radiotherapy Planning, Computer-Assisted/methods , Organs at Risk/radiation effects , Retrospective Studies
18.
Phys Med ; 123: 103396, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38943799

ABSTRACT

PURPOSE: Respiratory motion and patient setup error both contribute to the dosimetric uncertainty in radiotherapy of lung tumors. Managing these uncertainties for free-breathing treatments is usually done by margin-based approaches or robust optimization. However, breathing motion can be irregular and concerns have been raised for the robustness of the treatment plans. We have previously reported the dosimetric effects of the respiratory motion, without setup uncertainties, in lung tumor photon radiotherapy using free-breathing images. In this study, we include setup uncertainty. METHODS: Tumor positions from cine-CT images acquired in free-breathing were combined with per-fraction patient shifts to simulate treatment scenarios. A total of 14 patients with 300 tumor positions were used to evaluate treatment plans based on 4DCT. Four planning methods aiming at delivering 54 Gy as median tumor dose in three fractions were compared. The planning methods were denoted robust 4D (RB4), isodose to the PTV with a central higher dose (ISD), the ISD method normalized to the intended median tumor dose (IRN) and homogeneous fluence to the PTV (FLU). RESULTS: For all planning methods 95% of the intended dose was achieved with at least 90% probability with RB4 and FLU having equal CTV D50% values at this probability. FLU gave the most consistent results in terms of CTV D50% spread and dose homogeneity. CONCLUSIONS: Despite the simulated patient shifts and tumor motions being larger than observed in the 4DCTs the dosimetric impact was suggested to be small. RB4 or FLU are recommended for the planning of free-breathing treatments.


Subject(s)
Four-Dimensional Computed Tomography , Lung Neoplasms , Photons , Radiotherapy Planning, Computer-Assisted , Respiration , Humans , Lung Neoplasms/radiotherapy , Lung Neoplasms/diagnostic imaging , Uncertainty , Radiotherapy Planning, Computer-Assisted/methods , Photons/therapeutic use , Movement , Radiotherapy Dosage , Radiotherapy Setup Errors/prevention & control , Radiometry
19.
Med Phys ; 51(7): 5099-5108, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38112191

ABSTRACT

BACKGROUND: Superficial targets require the use of the lowest energies within the available energy range in proton pencil-beam scanning (PBS) technique. However, the lower efficiency of the energy selection system at these energies and the requirement of a greater number of layers may represent disadvantages for this approach. The alternative is to use a range shifter (RS) at nozzle exit. However, one of the concerns of using this beamline element is that it becomes an additional source of neutrons that could irradiate organs situated far from the target. PURPOSE: The purpose of this study is to assess the increase in neutron dose due to the RS in proton PBS technique. Additionally, an analytical model for the neutron production is tested. METHODS: Two clinical plans, designed to achieve identical target coverage, were created for an anthropomorphic phantom. These plans consisted of a lateral field delivering an absorbed dose of 60 Gy (RBE) to the target. One of the plans employed the RS. The MCNP code was used to simulate the plans, evaluating the distribution of neutron dose equivalent (Hn) and the equivalent dose in organ. In the plan with the RS plan, neutron production from both the patient and the RS were assessed separately. Hn values were also fitted versus the distance to field edge using a Gaussian function. RESULTS: Hn per prescription dose, in the plan using the RS, ranged between 1.4 and 3.7 mSv/Gy at the field edge, whereas doses at 40 cm from the edge ranged from 9.9 to 32 µSv/Gy. These values are 1.2 to 10 times higher compared to those obtained without the RS. Both this factor and the contribution of neutrons originating from the RS increases with the distance from field edge. A triple-Gaussian function was able to reproduce the equivalent dose in organs within a factor of 2, although underestimating the values. CONCLUSIONS: The dose deposited in the patient by the neutrons originating from the RS predominantly affects areas away from the target (beyond approximately 25 cm from field edge), resulting in a neutron dose equivalent of the order of mSv. This indicates an overall low neutron contribution from the use of RS in PBS.


Subject(s)
Neutrons , Phantoms, Imaging , Proton Therapy , Radiotherapy Dosage , Humans , Proton Therapy/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Monte Carlo Method , Radiation Exposure/analysis , Radiation Dosage
20.
Neurosurgery ; 94(2): 423-430, 2024 02 01.
Article in English | MEDLINE | ID: mdl-37665222

ABSTRACT

BACKGROUND AND OBJECTIVES: Brain metastases (BM) develop in nearly half of the patients with advanced melanoma. The aim of this retrospective historical cohort study was to analyze radiological response of melanoma BM to single-fraction Gamma Knife radiosurgery (GKRS), in relation to biologically effective dose (BED) for various alpha/beta ratios. METHODS: Included in the study were 274 lesions. Primary outcome was local control (LC). Mean marginal dose was 21.6 Gy (median 22, range 15-25). Biologically effective dose was calculated for an alpha/beta ratio of 3 (Gy 3 ), 5 (Gy 10 ), 10 (Gy 10 ), and 15 (Gy 15 ). RESULTS: Receiver operating characteristic value for LC and BED was 85% (most statistically significant odds ratio 1.14 for BED Gy 15 , P = .006), while for LC and physical dose was 79% ( P = .02). When comparing equality of 2 receiver operating characteristic areas, this was statistically significant ( P = .02 and .03). Fractional polynomial regression revealed BED (Gy 10 and Gy 15 ) as statistically significant ( P = .05) with BED of more than 63 Gy 10 or 49 Gy 15 as relevant, also for higher probability of quick decrease in volume first month after GKRS and lower probability of radiation necrosis. Shorter irradiation time was associated with better LC ( P = .001), particularly less than 40 minutes (LC below 90%, P = .05). CONCLUSION: BED Gy 10 and particularly Gy 15 were more statistically significant than physical dose for LC after GKRS for radioresistant melanoma BM. Irradiation time (per lesion) longer than 40 minutes was predictive for lower rates of LC. Such results need to be validated in larger cohorts.


Subject(s)
Brain Neoplasms , Melanoma , Radiosurgery , Humans , Radiosurgery/methods , Retrospective Studies , Cohort Studies , Melanoma/radiotherapy , Brain Neoplasms/radiotherapy , Brain Neoplasms/surgery , Brain Neoplasms/secondary , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL