Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Ann Vasc Surg ; 67: 568.e1-568.e8, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32234576

ABSTRACT

BACKGROUND: We report a rare case of delayed, symptomatic thoracic endograft thrombosis after the initial thoracic endovascular aortic repair (TEVAR) for blunt thoracic aortic injury which was successfully retreated with a redo TEVAR, followed by open conversion due to recurrent partial occlusion of the distal edge of the endografts. METHODS: Two years ago, a 22-year-old man had undergone an emergency TEVAR for blunt thoracic aortic injury. A Zenith Cook 22 × 100 mm (Cook Incorporated, Bloomington, IN) endograft was used. Six months later, he underwent an emergency endovascular relining of the endograft using the same type of device. The multiorgan perfusion was completely restored except for the spinal cord injury. After 8 months, a recurrent partial occlusion of the distal edge of the second graft was documented. The thoracic aorta was replaced with a 22-mm silver-coated graft (Maquet Spain, SLU). RESULTS: Histology examination showed a neointimal formation and thickening and fibrosis of the inner 1/3 of the media with loss of smooth muscle cells and increase of the elastic fibers. CONCLUSIONS: The need for secondary interventions or open conversion because of potential complications after TEVAR for traumatic aortic injury is an additional consideration when weighing the risks and benefits of endovascular repair and subsequent surveillance strategies.


Subject(s)
Aorta, Thoracic/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Graft Occlusion, Vascular/surgery , Thrombosis/surgery , Vascular System Injuries/surgery , Wounds, Nonpenetrating/surgery , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/physiopathology , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Graft Occlusion, Vascular/diagnostic imaging , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/physiopathology , Humans , Male , Recurrence , Reoperation , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/physiopathology , Treatment Outcome , Vascular Patency , Vascular System Injuries/diagnostic imaging , Vascular System Injuries/etiology , Vascular System Injuries/physiopathology , Wounds, Nonpenetrating/diagnostic imaging , Wounds, Nonpenetrating/etiology , Wounds, Nonpenetrating/physiopathology , Young Adult
2.
Ann Vasc Surg ; 47: 281.e5-281.e10, 2018 Feb.
Article in English | MEDLINE | ID: mdl-28893706

ABSTRACT

Thoracic endovascular aortic repair (TEVAR) is a less invasive option for managing traumatic injuries of the descending aorta in polytraumatized patients. Concerns arise when treating young patients with TEVAR. A 22-year-old male was admitted to the emergency department following a high-impact road traffic collision. Whole-body computed tomography (CT) scan documented multiple injuries, including rupture of descending thoracic aorta just below the isthmus. There was no evidence of paraplegia or stroke. We decided to treat him in an endovascular fashion with a Zenith Cook (Cook Incorporated, Bloomington, IN) endograft. Final angiography confirmed the proper positioning of the device, no infoldings, and the optimal filling of the thoracic aorta downstream of the endoprosthesis. In the postoperative period, the patient showed high blood pressure which was treated with 4 different antihypertensive drugs. He was discharged on cardioaspirine. CT scan control was scheduled after 30 days and 6 months, but he referred to our emergency department after less than 6 months with paraplegia, abdominal pain, and acute renal failure. He had independently discontinued antiplatelet therapy 3 months before. Emergency CT control documented the presence of intimal flap and thrombus at the distal edge of the device. The magnetic resonance imaging revealed ischemic damage of the spinal cord. We decided to reline the endograft using another Zenith Cook device with very good results. Renal failure and bowel pain gradually improved, but paraplegia is still present. TEVAR is the most suitable treatment for blunt thoracic aortic injury in the modern era. Concerns arise from what can happen to a young aorta receiving a stiff endovascular graft that should be carried all lifelong. These devices have been associated with acute hypertension and cardiac remodeling. Less stiffer stent grafts should be studied for young patients. High attention must be posed in the follow-up for the immediate resolution of eventual problems.


Subject(s)
Aorta, Thoracic/surgery , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endovascular Procedures , Hypertension/etiology , Paraplegia/etiology , Stents , Thrombosis/etiology , Vascular System Injuries/surgery , Wounds, Nonpenetrating/surgery , Accidents, Traffic , Antihypertensive Agents/therapeutic use , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/injuries , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Computed Tomography Angiography , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Humans , Hypertension/diagnosis , Hypertension/drug therapy , Magnetic Resonance Imaging , Male , Paraplegia/diagnostic imaging , Paraplegia/therapy , Platelet Aggregation Inhibitors/therapeutic use , Prosthesis Design , Thrombosis/diagnostic imaging , Thrombosis/therapy , Time Factors , Treatment Outcome , Vascular System Injuries/diagnostic imaging , Vascular System Injuries/etiology , Wounds, Nonpenetrating/diagnostic imaging , Wounds, Nonpenetrating/etiology , Young Adult
3.
Ann Vasc Surg ; 27(2): 240.e9-240.e11, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23380561

ABSTRACT

Endovascular treatment of persistent type II endoleak may not resolve the complication. We report two cases of sacotomy performed to treat this problem: the first case was in an emergency setting for aneurismal sac rupture, and the second occurred in an elective surgery setting after several unsuccessful endovascular procedures. In both cases, sacotomy allowed us identify the bleeding sources without aortic cross-clamping and endograft explantation. By minimizing hemodynamic modifications and reducing operative time, this procedure can be carried out even in patients considered unfit for surgery. Sacotomy could be considered as an alternative in selected cases of persistent type II endoleak with aneurysm sac enlargement.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/surgery , Endovascular Procedures/adverse effects , Aged, 80 and over , Aortography/methods , Endoleak/diagnostic imaging , Endoleak/etiology , Female , Humans , Male , Reoperation , Tomography, X-Ray Computed , Treatment Outcome
4.
Thorac Cardiovasc Surg ; 61(7): 606-9, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23564532

ABSTRACT

Both aortic pseudoaneurysm following endovascular aortoiliac reconstruction and spondylodiscitis subsequent to endograft infections are rare complications. We present a case of aortic false aneurysm following iliac arteries treatment complicated by spondylodiscitis after its endovascular repair. In this patient, a huge aortic pseudoaneurysm was diagnosed and treated in an emergency setting a few days after the procedure. A left aortomonoiliac endograft was placed and a femoro-femoral crossover bypass was performed. Afterward, the patient developed a stent graft infection and a lumbar spondylodiscitis. The patient was managed with a conservative treatment and, after 4 years, he continues to live. Analyzing this case, we would like to point out the following aspects: any procedure, although well established and technically simple, can cause life-threatening complications; hematomas resulting from endovascular exclusion of large pseudoaneurysms could be drained, to prevent bacterial infections.


Subject(s)
Aneurysm, False/etiology , Aortic Aneurysm/etiology , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis/adverse effects , Discitis/etiology , Endovascular Procedures/adverse effects , Iliac Artery/surgery , Prosthesis-Related Infections/etiology , Stents/adverse effects , Aneurysm, False/diagnosis , Aneurysm, False/surgery , Anti-Bacterial Agents/therapeutic use , Aortic Aneurysm/diagnosis , Aortic Aneurysm/surgery , Aortography/methods , Blood Vessel Prosthesis Implantation/instrumentation , Discitis/diagnosis , Discitis/therapy , Drainage , Emergencies , Endovascular Procedures/instrumentation , Humans , Male , Middle Aged , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/therapy , Reoperation , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
5.
JACC Cardiovasc Interv ; 14(17): 1917-1923, 2021 09 13.
Article in English | MEDLINE | ID: mdl-34391704

ABSTRACT

OBJECTIVES: The aim of this study was to evaluate the 1-year safety and efficacy of a dual-layered stent (DLS) for carotid artery stenting (CAS) in a multicenter registry. BACKGROUND: DLS have been proved to be safe and efficient during short-term follow-up. Recent data have raised the concern that the benefit of CAS performed with using a DLS may be hampered by a higher restenosis rate at 1 year. METHODS: From January 2017 to June 2019, a physician-initiated, prospective, multispecialty registry enrolled 733 consecutive patients undergoing CAS using the CGuard embolic prevention system at 20 centers. The primary endpoint was the occurrence of death and stroke at 1 year. Secondary endpoints were 1-year rates of transient ischemic attack, acute myocardial infarction, internal carotid artery (ICA) restenosis, in-stent thrombosis, and external carotid artery occlusion. RESULTS: At 1 year, follow-up was available in 726 patients (99.04%). Beyond 30 days postprocedure, 1 minor stroke (0.13%), four transient ischemic attacks (0.55%), 2 fatal acute myocardial infarctions (0.27%), and 6 noncardiac deaths (1.10%) occurred. On duplex ultrasound examination, ICA restenosis was found in 6 patients (0.82%): 2 total occlusions and 4 in-stent restenoses. No predictors of target ICA restenosis and/or occlusion could be detected, and dual-antiplatelet therapy duration (90 days vs 30 days) was not found to be related to major adverse cardiovascular event or restenosis occurrence. CONCLUSIONS: This real-world registry suggests that DLS use in clinical practice is safe and associated with minimal occurrence of adverse neurologic events up to 12-month follow-up.


Subject(s)
Carotid Stenosis , Carotid Artery, Internal , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/therapy , Humans , Prospective Studies , Stents , Treatment Outcome
6.
JACC Cardiovasc Interv ; 13(18): 2170-2177, 2020 09 28.
Article in English | MEDLINE | ID: mdl-32861633

ABSTRACT

OBJECTIVES: This study sought to evaluate 30-day safety and efficacy of dual-layer mesh-covered carotid stent systems for carotid artery stenting (CAS) in the clinical practice. BACKGROUND: When compared with carotid endarterectomy, CAS has been associated with a higher rate of post procedural neurologic events; these could be related to plaque's debris prolapsing through stent's mesh. Consequently, the need for increased plaque coverage has resulted in the development of dual-layer mesh-covered carotid stent systems. METHODS: From January 2017 to June 2019, a physician-initiated, prospective, multispecialty registry enrolled 733 consecutive patients undergoing CAS using the CGuard embolic prevention system in 20 centers. The primary endpoint was stroke up to 30 days; secondary endpoints were technical and procedural success; external carotid artery occlusion; and in-hospital and 30-day transient ischemic attack (TIA), acute myocardial infarction (AMI), and death rates. RESULTS: Symptoms were present in 131 (17.87%) patients. An embolic protection device was used in 731 (99.72%) patients. Procedural success was 100%, technical success was obtained in all but 1 (99.86%) patient, who died in hospital due to a hemorrhagic stroke. Six TIAs, 2 minor strokes, and 1 AMI occurred during in-hospital stay, and external carotid artery occlusion was evident in 8 (1.09%) patients. Between hospital discharge and 30-day follow-up, 2 TIAs, 1 minor stroke, and 3 AMIs occurred. Therefore, the cumulative stroke rate was 0.54%. CONCLUSIONS: This real-world registry suggests that use of CGuard embolic prevention system in clinical practice is safe and associated with a minimal occurrence of adverse neurological events up to 30-day follow-up.


Subject(s)
Carotid Stenosis , Stroke , Humans , Prospective Studies , Stents , Time Factors , Treatment Outcome
10.
Infect Dis Rep ; 8(3): 6515, 2016 Sep 29.
Article in English | MEDLINE | ID: mdl-31343642

ABSTRACT

Aeromonas hydrophila has been infrequently reported as a cause of infection in humans. It has been associated with a variety of clinical syndromes but Aeromonas-related endocarditis is extremely rare. We present the case of a 76-year-old diabetic patient who was admitted to our hospital due to severe lumbar pain resistant to nonsteroidal anti-inflammatory drugs accompanied by fever (up to 38.5°C). The vital signs were normal and the physical examination was unremarkable except for tenderness over right flank. Laboratory investigation showed a mild leukocytosis (white blood cell count of 11,360×106/L) with elevation of inflammatory markers. Cardiac ultrasound showed a large vegetation on the mitral valve. Abdominal computed tomogrpahy revealed a ruptured aneurysm of the right renal artery. Multiple sets of blood culture grew A. hydrophila.

11.
J Infect Chemother ; 11(6): 297-9, 2005 Dec.
Article in English | MEDLINE | ID: mdl-16369737

ABSTRACT

Infections due to nontyphoidal Salmonella are common and their incidence has been increasing in the last few years. Here, we describe a patient with a rupture of abdominal aortic aneurysm associated with a psoas abscess due to Salmonella typhimurium. Early diagnosis, prompt surgical intervention, and active and prolonged antibiotic therapy are the gold standard for the management of this severe clinical situation.


Subject(s)
Aorta, Abdominal/surgery , Aortic Aneurysm, Abdominal/microbiology , Iliac Artery/surgery , Prosthesis-Related Infections/microbiology , Psoas Abscess/microbiology , Salmonella Infections/microbiology , Salmonella typhimurium/isolation & purification , Aneurysm, Infected/microbiology , Aneurysm, Ruptured/microbiology , Aorta, Abdominal/microbiology , Blood Vessel Prosthesis/microbiology , Humans , Iliac Artery/microbiology , Male , Middle Aged
12.
J Craniofac Surg ; 13(6): 816-20, 2002 Nov.
Article in English | MEDLINE | ID: mdl-12457099

ABSTRACT

Internal carotid artery (ICA) reparative techniques are nowadays widely standardized in traumatic as well as degenerative pathological conditions; therefore, the greatest difficulty encountered in the treatment of lesions at the expense of the most distal segment of the ICA is not a result of the application of these techniques as much as the difficulty in obtaining adequate exposure of the vessel and a sufficiently wide surgical field. In the past, lesions localized more toward the skull were considered to be surgically unreachable. During the last 20 years, however, various techniques have been suggested and attempted for the exposure of this difficult area. This article suggests a type of approach already carried out by the Department of Maxillofacial Surgery of the University of Rome "La Sapienza" in collaboration with the II Department of Vascular Surgery of the same university, which offers the advantage of being of simple and rapid execution with minimum repercussions on the intrasurgical time required and guarantees an excellent exposure of the most distal tract of the ICA with an adequate widening of the surgical field.


Subject(s)
Carotid Artery, Internal/surgery , Carotid Stenosis/surgery , Endarterectomy, Carotid/methods , Mandible/surgery , Oral Surgical Procedures/methods , Aged , Anastomosis, Surgical/methods , Carotid Artery, Common/surgery , Humans , Male , Osteotomy/methods
SELECTION OF CITATIONS
SEARCH DETAIL