Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Circ J ; 84(5): 786-791, 2020 04 24.
Article in English | MEDLINE | ID: mdl-32238666

ABSTRACT

BACKGROUND: The Harmonization By Doing (HBD) program was established in 2003 as a partnership among stakeholders of academia, industry and regulatory agencies in Japan and the United States, with a primary focus on streamlining processes of global medical device development for cardiovascular medical devices. While HBD has traditionally focused on development of devices intended to treat conditions prevalent in adults, in 2016, HBD established the "HBD-for-Children" program, which focuses on the development of pediatric devices as the development of medical devices for pediatric use lags behind that of medical devices for adults in both countries.Methods and Results:Activities of the program have included: (1) conducting a survey with industry to better understand the challenges that constrain the development of pediatric medical devices; (2) categorizing pediatric medical devices into five categories based on global availability and exploring concrete solutions for the early application and regulatory approval in both geographies; and (3) facilitating global clinical trials of pediatric medical devices in both countries. CONCLUSIONS: The establishment of the HBD-for-Children program is significant because it represents a global initiative for the introduction of pediatric medical devices for patients in a timely manner. Through the program, academia, industry and regulatory agencies can work together to facilitate innovative pediatric device development from a multi-stakeholder perspective. This activity could also encourage industry partners to pursue the development of pediatric medical devices.


Subject(s)
Cardiac Catheterization/instrumentation , Cardiac Surgical Procedures/instrumentation , Cardiovascular Diseases/therapy , Cooperative Behavior , Equipment Design , Equipment and Supplies , International Cooperation , Pediatrics/instrumentation , Public-Private Sector Partnerships , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/physiopathology , Humans , Japan , Program Evaluation , Stakeholder Participation , United States
2.
J Transl Med ; 16(1): 57, 2018 03 09.
Article in English | MEDLINE | ID: mdl-29523171

ABSTRACT

BACKGROUND: Multiple sclerosis (MS) is a progressively debilitating neurological condition in which the immune system abnormally erodes the myelin sheath insulating the nerves. Mesenchymal stem cells (MSC) have been used in the last decade to safely treat certain immune and inflammatory conditions. METHODS: A safety and feasibility study was completed on the use of umbilical cord MSC (UCMSC) as a treatment for MS. In this 1-year study, consenting subjects received seven intravenous infusions of 20 × 106 UCMSC over 7 days. Efficacy was assessed at baseline, 1 month and 1 year after treatment, including magnetic resonance imaging (MRI) scans, Kurtzke Expanded Disability Status Scale (EDSS), Scripps Neurological Rating Scale, Nine-Hole Peg Test, 25-Foot Walk Test, and RAND Short Form-36 quality of life questionnaire. RESULTS: Twenty subjects were enrolled in this study. No serious adverse events were reported. Of the mild AEs denoted as possibly related to treatment, most were headache or fatigue. Symptom improvements were most notable 1 month after treatment. Improvements were seen in EDSS scores (p < 0.03), as well as in bladder, bowel, and sexual dysfunction (p < 0.01), in non-dominant hand average scores (p < 0.01), in walk times (p < 0.02) and general perspective of a positive health change and improved quality of life. MRI scans of the brain and the cervical spinal cord showed inactive lesions in 15/18 (83.3%) subjects after 1 year. CONCLUSIONS: Treatment with UCMSC intravenous infusions for subjects with MS is safe, and potential therapeutic benefits should be further investigated. Trial registration ClinicalTrials.gov NCT02034188. Registered Jan 13, 2014. https://clinicaltrials.gov/ct2/show/NCT02034188.


Subject(s)
Mesenchymal Stem Cell Transplantation , Mesenchymal Stem Cells/cytology , Multiple Sclerosis/therapy , Umbilical Cord/cytology , Adult , Feasibility Studies , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Multiple Sclerosis/diagnostic imaging , Treatment Outcome , Young Adult
4.
Cardiovasc Revasc Med ; 52: 67-74, 2023 07.
Article in English | MEDLINE | ID: mdl-36870799

ABSTRACT

As medical device development becomes increasingly global, the opportunities and potential advantages offered by international clinical trial and regulatory approval strategies are also growing. In particular, medical device clinical trials involving sites in both the United States and Japan and intended to support marketing in both countries may warrant particular consideration, given the similarities in their regulatory systems, patients and clinical practice patterns, and market sizes. Since 2003, the US-Japan Harmonization By Doing (HBD) initiative has been focused on identifying and addressing clinical and regulatory barriers to medical devices access in both countries via collaboration between governmental, academic, and industry stakeholders. Through the efforts of HBD participants, US-Japanese clinical trials have been conducted and the resulting data have supported regulatory approval for marketing in both countries. Based on these experiences, this paper outlines some of the key factors to consider when developing a global clinical trial involving US and Japanese participation. These considerations include the mechanisms for consultation with regulatory authorities on clinical trial strategies, the regulatory framework for clinical trial notification and approval, recruitment and conduct of clinical sites, and lessons learned from specific US-Japanese clinical trial experiences. The goal of this paper is to promote global access to promising medical technologies by assisting potential clinical trial sponsors in understanding when an international strategy may be appropriate and successful.


Subject(s)
Device Approval , Humans , United States , Japan
5.
Cardiovasc Revasc Med ; 37: 112-117, 2022 04.
Article in English | MEDLINE | ID: mdl-34607786

ABSTRACT

Effective treatment strategies and medical devices continue to be needed in Japan and the United States of America (US) to mitigate the growing burden of cardiovascular disease and coronary heart disease. Unfortunately, there can be a delay in gaining cardiovascular device approval in Japan after a device has already been approved and is in use in the US. The Harmonization by Doing (HBD) program; however, can eliminate this delay and reduce the cost of completing a clinical trial in Japan. The HBD proof-of-concept study, COAST, resulted in approval of the Diamondback 360® Coronary Orbital Atherectomy System Micro Crown simultaneously in Japan and the US on the same day. Subsequently, the Diamondback 360® Coronary OAS Classic Crown also received approval in Japan. The COAST study provides further evidence that global clinical trials via HBD for medical devices are practical and advantageous.


Subject(s)
Atherectomy, Coronary , Coronary Artery Disease , Percutaneous Coronary Intervention , Vascular Calcification , Atherectomy , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Humans , Japan , Severity of Illness Index , Treatment Outcome , United States , Vascular Calcification/diagnostic imaging , Vascular Calcification/therapy
6.
Circulation ; 108(11): 1295-8, 2003 Sep 16.
Article in English | MEDLINE | ID: mdl-12952833

ABSTRACT

BACKGROUND: This study used serial volumetric intravascular ultrasound (IVUS) to evaluate the effect of preinterventional arterial remodeling on in-stent intimal hyperplasia (IH) after implantation of non-polymer-encapsulated paclitaxel-coated stents. METHODS AND RESULTS: Patients were randomized to placebo or one of two doses of paclitaxel (low dose, 1.28 microg/mm2; high dose, 3.10 microg/mm2). Complete preinterventional, post-stent implantation, and follow-up IVUS were available in 18 low-dose and 21 high-dose patients. IH volumes were similar in low-dose and high-dose patients: 17.6+/-15.1 mm3 in low-dose patients and 13.1+/-13.3 mm3 in high-dose patients (P=0.3). Therefore, IVUS findings in low- and high-dose patients were combined. Preinterventional remodeling was assessed by comparing lesion site to proximal and distal reference arterial area: positive remodeling (lesion>proximal reference, n=13), intermediate remodeling (distal reference

Subject(s)
Coronary Restenosis/prevention & control , Paclitaxel/therapeutic use , Stents , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/pathology , Female , Humans , Hyperplasia , Male , Middle Aged , Paclitaxel/administration & dosage , Stents/adverse effects , Tunica Intima/diagnostic imaging , Tunica Intima/pathology , Ultrasonography
7.
Circulation ; 107(4): 517-20, 2003 Feb 04.
Article in English | MEDLINE | ID: mdl-12566359

ABSTRACT

BACKGROUND: The aim of this study was to use serial volumetric intravascular ultrasound (IVUS) to evaluate the effect of a paclitaxel coating on in-stent intimal hyperplasia (IH). METHODS AND RESULTS: Patients were randomized to placebo (bare metal stents) or 1 of 2 doses of paclitaxel (low dose: 1.28 microg/mm2; high dose: 3.10 microg/mm2). Complete post-stent implantation and follow-up IVUS were available in 81 patients, including 25 control patients and in 28 receiving a low-dose and 28 receiving a high dose. Volumetric analysis of the stented segment and of both reference segments was performed. Baseline stent measurements and both reference measurements were similar among the groups. With increasing doses, there was a stepwise reduction in IH accumulation within the stented segment (31+/-22 mm3 in control, 18+/-15 mm3 in low dose, and 13+/-14 mm3 in high dose, P<0.001). Post hoc analysis showed less IH accumulation when low- and high-dose patients were compared with control (P=0.009 and P<0.001, respectively), but not when low-dose patients were compared with high-dose patients (P=0.2). Focal late malapposition was seen in 1 high-dose patient. With increasing doses, there was no significant change in the reference segments. CONCLUSIONS: Paclitaxel-coated stents are effective in reducing in-stent neointimal tissue proliferation in humans. They are not associated with edge restenosis or significant late malapposition.


Subject(s)
Coated Materials, Biocompatible , Coronary Artery Disease/diagnostic imaging , Coronary Restenosis/prevention & control , Hyperplasia/prevention & control , Paclitaxel/administration & dosage , Stents , Cell Division/drug effects , Coated Materials, Biocompatible/adverse effects , Coronary Artery Disease/surgery , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Dose-Response Relationship, Drug , Drug Implants/administration & dosage , Female , Follow-Up Studies , Humans , Hyperplasia/diagnostic imaging , Male , Middle Aged , Stents/adverse effects , Treatment Outcome , Tunica Intima/diagnostic imaging , Tunica Intima/drug effects , Ultrasonography, Interventional
8.
Am J Cardiol ; 95(1): 107-9, 2005 Jan 01.
Article in English | MEDLINE | ID: mdl-15619404

ABSTRACT

Using data from the ASian Paclitaxel-Eluting Stent Clinical Trial, a 3-center, randomized, placebo-controlled trial of nonpolymeric paclitaxel-coated stents with a single center, 81-patient intravascular ultrasound (IVUS) substudy, the length of a stent that was free of IVUS-detectable intimal hyperplasia measured 3.2 +/- 4.8 mm in placebo stents, 6.1 +/- 5.6 mm in low-dose stents, and 8.7 +/- 6.1 mm in high-dose stents (p = 0.0029). IVUS percent neointima volume obstruction correlated with the length of this IVUS neointima-free segment (r = 0.785, p <0.0001); angiographic late lumen loss and follow-up diameter stenosis also correlated with the IVUS neointima-free length of the stents (r = 0.670, p <0.0001 and r = 0.679, p <0.0001, respectively.


Subject(s)
Coronary Restenosis/diagnostic imaging , Coronary Restenosis/prevention & control , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Drug Delivery Systems , Paclitaxel/administration & dosage , Stents , Tunica Intima/diagnostic imaging , Tunica Intima/pathology , Ultrasonography, Interventional , Humans , Hyperplasia/diagnostic imaging , Randomized Controlled Trials as Topic
9.
Am J Cardiol ; 95(1): 105-7, 2005 Jan 01.
Article in English | MEDLINE | ID: mdl-15619403

ABSTRACT

We used data from the ASian Paclitaxel-Eluting Stent Clinical Trial (a 3-center, randomized, placebo-controlled trial of nonpolymeric paclitaxel-coated stents with a single-center intravascular ultrasound substudy) to compare angiographic indexes of drug-eluting stent efficacy with the magnitude of intimal hyperplasia (IH) assessed by intravascular ultrasound. Overall, percent IH (IH volume divided by stent volume) was larger in restenotic lesions than in nonrestenotic lesions (46 +/- 19% vs 15 +/- 13%, p <0.0001); angiographic late loss and follow-up diameter stenoses correlated strongly with percent IH.


Subject(s)
Coronary Angiography , Coronary Restenosis/diagnostic imaging , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Drug Delivery Systems , Paclitaxel/administration & dosage , Stents , Tunica Intima/diagnostic imaging , Tunica Intima/pathology , Ultrasonography, Interventional , Coronary Restenosis/prevention & control , Humans , Hyperplasia/diagnostic imaging , Randomized Controlled Trials as Topic
10.
J Thorac Cardiovasc Surg ; 130(2): 477-84, 2005 Aug.
Article in English | MEDLINE | ID: mdl-16077416

ABSTRACT

OBJECTIVE: We sought to investigate a placement of a percutaneous low-profile prosthetic valve constructed of small intestinal submucosa in the pulmonary position in a swine model. METHODS: Twelve female farm pigs were stented at the native pulmonary valve to induce pulmonary insufficiency. Once right ventricular dilation occurred, the small intestinal submucosa valve was implanted. The pigs were followed up with transthoracic echocardiographic Doppler scanning. One animal died of heart failure before valve replacement. Animals were euthanized at 1 day, 1 month, 3 months, 6 months, and 12 months after valve implantation. RESULTS: The small intestinal submucosa pulmonary valve showed effective reversal of pulmonary regurgitation. There were no misplacements during deployment. There were no embolizations. One-year echocardiographic follow-up showed minimal regurgitation and no stenosis for a valve/vessel ratio of 0.78 or greater. Histologic examination demonstrated intensive remodeling of the small intestinal submucosal valve. Within 1 month, the surface was covered by endothelium, and fibroblasts invaded the interior. Over the following months, the small intestinal submucosal valve remodeled without apparent graft rejection. CONCLUSION: The small intestinal submucosa valve has the potential for graft longevity without the need for anticoagulation or immunosuppression. Histologic remodeling of the valve tissue provides a replacement capable of resembling a native valve that can be placed percutaneously with low-profile delivery systems.


Subject(s)
Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Intestine, Small/transplantation , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve , Absorbable Implants , Animals , Catheterization , Female , Graft Survival , Intestinal Mucosa/transplantation , Models, Animal , Swine
11.
Am J Cardiol ; 94(2): 196-8, 2004 Jul 15.
Article in English | MEDLINE | ID: mdl-15246900

ABSTRACT

To determine the relation of intimal hyperplasia thickness to stent size in nonpolymeric paclitaxel-coated stents, intravascular ultrasound was performed after stent implantation and at 6 months. Similar to bare metal stents, this study demonstrated that intimal hyperplasia thickness is independent of stent size. There was no deleterious effect of the increased concentration associated with using the same stent design in a smaller artery, and these results suggested that stent strut density may be a more important concept than drug concentration.


Subject(s)
Antineoplastic Agents, Phytogenic/administration & dosage , Paclitaxel/administration & dosage , Stents , Tunica Intima/pathology , Humans , Hyperplasia , Prosthesis Design , Randomized Controlled Trials as Topic , Tunica Intima/diagnostic imaging , Ultrasonography, Interventional
12.
Am J Cardiol ; 94(2): 199-201, 2004 Jul 15.
Article in English | MEDLINE | ID: mdl-15246901

ABSTRACT

The investigators examined 326 pairs of angiograms from 2 randomized dose-finding (0.2 to 3.1 microg paclitaxel/mm(2) of stent surface area) clinical trials of polymer-free paclitaxel-eluting stents in de novo lesions (the ASian Paclitaxel-Eluting stent Clinical Trial [ASPECT] and the European evaLUation of Taxol Eluting Stent [ELUTES]). A dose-dependent effect was observed: the largest dose of paclitaxel in the 2 trials resulted in a significantly larger proportion of lesions at follow-up with <10% diameter stenosis (54% vs 16%, p = 0.00012 in ASPECT; 53% vs 21%, p = 0.013 in ELUTES) and with minimal luminal diameter located outside the stent compared with control stents (62% vs 20% in ASPECT, 48% vs 18% in ELUTES; p <0.05). Also, significantly shorter lesion lengths at 6-month follow-up were observed for the doses of 0.7 to 3.1 microg/mm(2) (p <0.03) relative to their respective lengths before the procedure compared with control stents.


Subject(s)
Angiogenesis Inhibitors/administration & dosage , Coronary Restenosis/prevention & control , Paclitaxel/administration & dosage , Stents , Tunica Intima/pathology , Coronary Angiography , Dose-Response Relationship, Drug , Humans , Hyperplasia/prevention & control , Prosthesis Design , Randomized Controlled Trials as Topic , Stainless Steel
13.
J Vasc Surg ; 48(1): 1-9, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18486418

ABSTRACT

PURPOSE: The safety and efficacy of the Zenith (Cook Inc, Bloomington, Ind) endovascular graft was assessed based on the United States multicenter trial through 5 years of follow-up. METHODS: Between 2000 and 2003, the pivotal study enrolled patients to open surgery (control) or the Zenith endovascular graft (endovascular). A separate continued access study arm enrolled endovascular patients using the same inclusion/exclusion criteria. Both studies were designed for 2-year follow-up, and the pivotal endovascular patients had the option of extending the study follow-up through 5 years. All endovascular patients were stratified by physiologic risk into high-risk and standard-risk groups to assess overall mortality, rupture, conversion, endoleaks, secondary interventions, and sac enlargement. The entire endovascular cohort was pooled to assess device integrity, limb occlusion, component separation, and migration. The suboptimal endovascular result (SER) was established as an end point to assess late adverse outcomes. Statistical analyses included Kaplan-Meier estimations and Cox regression to assess factors contributing to sac enlargement and SER. RESULTS: The study enrolled 739 endovascular patients (352 pivotal, 387 continued access); 158 patients in the pivotal study reconsented to be followed up for 5 years. For the patients at standard and high risk at 5 years, the respective survival estimate was 83% and 61%, aneurysm-related death was 2% and 4%, and freedom from rupture was 100% and 99.6%, respectively. Cumulative risk of conversion, limb occlusion, migration >10 mm, or component separation was < or =3% at 5 years. Cumulative risk of late endoleak was 12% to 15%, representing the primary indication for secondary interventions which occurred in 20% of standard-risk patients and 25% of high-risk patients through 5 years. Sac enlargement was very rare and associated with advanced age and larger aneurysms. SER was predicted by advanced age and internal iliac artery occlusion. CONCLUSION: These middle- and long-term data support long-term durability of the Zenith endovascular graft. Risk of aneurysm-related death or rupture was exceptionally low, and complications of migration, limb occlusion, and device integrity issues were uncommon. Incidence of late endoleaks and association of endoleaks with sac growth underscore the need for long-term follow-up of patients treated with endovascular grafts, although the sequelae of such events are unknown.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis/adverse effects , Blood Vessel Prosthesis Implantation , Follow-Up Studies , Humans , Prosthesis Design , Prosthesis Failure , Stents , Treatment Outcome
14.
J Vasc Surg ; 39(6): 1209-18, 2004 Jun.
Article in English | MEDLINE | ID: mdl-15192559

ABSTRACT

PURPOSE: The intent of this study was to assess the safety and effectiveness of the Zenith AAA Endovascular Graft compared with conventional aneurysm repair. MATERIAL AND METHODS: The study was conducted in a prospective, multicenter, nonrandomized, concurrent control manner. Physiologically similar patients with infrarenal abdominal aortic aneurysms (AAAs) underwent either open surgery or repair with the Zenith AAA Endovascular Graft. Separate analyses of physiologically challenged patients were performed. Follow-up was conducted at hospital discharge and at 1, 6, and 12 months (endovascular repair group) or 1 and 12 months (open surgical repair group). Evaluation included computed tomography, abdominal radiography, laboratory tests, and physical examination. Mortality (AAA-related and overall), morbidity, in-hospital recovery, renal function, and secondary interventions were assessed. Patients in the endovascular repair group were evaluated for change in aneurysm size, endoleak, graft migration, conversion, rupture, and device integrity. Statistical analyses were performed with the Kaplan-Meier method, Blackwelder test, propensity score assessment, two-sample t test, Yates-corrected Pearson chi(2) test, and Fisher exact test. RESULTS: Conventional open surgery was used in 80 patients, and 200 patients underwent repair with the Zenith AAA Endovascular Graft. Technical success was accomplished in 98.8% of patients in the open repair group and 99.5% in the endovascular repair group. Patients in the endovascular repair group had fewer significant adverse events within 30 days (80% vs 57%; P <.001). All-cause mortality was similar (endovascular, 3.5%; open surgery, 3.8%). Aneurysm-related mortality was higher with conventional surgery at 12 months (3.8% vs 0.5%; P =.04). In-hospital recovery and procedural measures were better for endovascular repair in all categories (P <.001). The incidence of endoleak was 17% at 30 days, 7.4% at 12 months, and 5.4% at 24 months. Aneurysm shrinkage (>5 mm) was noted in more than two thirds of patients at 12 months and three fourths of patients at 24 months. Renal dysfunction rate did not differ between groups. Migration (>5 mm) was detected in four (2%) patients through 12 months; none was greater than 10 mm or associated with adverse events through 24 months. Three conversions were performed within 12 months, one because of aneurysm rupture. Secondary procedures were more common in the endovascular group (11% vs 2.5%; P =.03). In total, 351 patients had endografts implanted, and 6 patients were noted to have barb separations through 12-month follow-up. No stent fractures were noted. CONCLUSIONS: The Zenith AAA Endovascular Graft is safe and effective for treatment of infrarenal AAAs. The high likelihood of decrease in aneurysm size provides evidence that treatment of aneurysms with this device reverses the natural history of aneurysmal disease. The importance of long-term follow-up is underscored by the small but defined incidence of barb separation and the potential for unforeseen failure modes.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/epidemiology , Aortic Rupture/epidemiology , Aortic Rupture/etiology , Biomarkers/blood , Creatinine/blood , Equipment Design , Equipment Safety , Female , Follow-Up Studies , Humans , Kidney/metabolism , Kidney/physiopathology , Male , Middle Aged , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Prospective Studies , Risk Factors , Survival Analysis , Time Factors , Treatment Outcome , United States/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL