Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters

Database
Language
Journal subject
Affiliation country
Publication year range
1.
Sensors (Basel) ; 23(3)2023 Jan 20.
Article in English | MEDLINE | ID: mdl-36772222

ABSTRACT

Electrical impedance tomography (EIT) is a medical imaging technique based on the injection of a current or voltage pattern through electrodes on the skin of the patient, and on the reconstruction of the internal conductivity distribution from the voltages collected by the electrodes. Compared to other imaging techniques, EIT shows significant advantages: it does not use ionizing radiation, is non-invasive and is characterized by high temporal resolution. Moreover, its low cost and high portability make it suitable for real-time, bedside monitoring. However, EIT is also characterized by some technical limitations that cause poor spatial resolution. The possibility to design wearable devices based on EIT has recently given a boost to this technology. In this paper we reviewed EIT physical principles, hardware design and major clinical applications, from the classical to a wearable setup. A wireless and wearable EIT system seems a promising frontier of this technology, as it can both facilitate making clinical measurements and open novel scenarios to EIT systems, such as home monitoring.


Subject(s)
Tomography , Wearable Electronic Devices , Humans , Tomography/methods , Electric Impedance , Tomography, X-Ray Computed , Electric Conductivity , Electrodes
2.
Molecules ; 27(12)2022 Jun 14.
Article in English | MEDLINE | ID: mdl-35745090

ABSTRACT

Due to the fact that the policy regarding the publication of images from the collection of the Papyrological Institute, the owner of the object under study, changed when the article was already in publication, the authors would like to make the following corrections to this paper [...].

3.
Molecules ; 26(17)2021 08 30.
Article in English | MEDLINE | ID: mdl-34500701

ABSTRACT

Fayum mummy portraits, painted around 2000 years ago, represent a fascinating fusion of Egyptian and Graeco-Roman funerary and artistic traditions. Examination of these artworks may provide insight into the Roman Empire's trade and economic and social structure during one of its most crucial yet still hazy times of transition. The lack of proper archaeological documentation of the numerous excavated portraits currently prevents their chronological dating, be it absolute or relative. So far, their production period has been defined essentially on the basis of the relevant differences in their pictorial style. Our study introduces the use of Accelerator Mass Spectrometry (AMS) to assess the age of a fragment of an encaustic painting belonging to the corpus of the Fayum portraits. The unexpected age resulting from 14C analysis suggests the need to reconsider previous assumptions regarding the period of production of the Fayum corpus. Furthermore, our multi-analytical, non-invasive approach yields further details regarding the fragment's pictorial technique and constituting materials, based on spectral and morphological analysis and cross-sectional examination.

SELECTION OF CITATIONS
SEARCH DETAIL