Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters

Database
Country/Region as subject
Language
Affiliation country
Publication year range
1.
Huan Jing Ke Xue ; 38(2): 502-509, 2017 Feb 08.
Article in Zh | MEDLINE | ID: mdl-29964505

ABSTRACT

This paper analyzed 17 polychlorinated dibenzo-p-dioxins and dibenzofurans(PCDD/Fs) by HRGC/HRMS in the flue gas of a certain municipal solid waste incinerator(MSWI) and its surrounding air and other possible sources in Guangdong. It discussed the feature of homologs and main toxic monomers in all samples. It also investigated the relationship among surrounding area, MSWI and possible sources using principle component analysis (PCA) and cluster analysis. The results showed that the concentration of PCDD/Fs was higher in the flue gas than the ambient air, moreover non-effect suffered by prevailing wind direction. The possible sources might be tyre factory and open burning based on spot survey. The concentration of PCDD/Fs was lower in tyre factory than upwind station, but higher at open burning spot than outdrop monitoring station. The analysis of homologs showed that OCDD, 1,2,3,4,6,7,8-HpCDD and 1,2,3,4,6,7,8-HpCDF were the main materials in the flue gas and air, meanwhile OCDF was also found in atmosphere. There was similar feature of 17 PCDD/Fs between surrounding monitoring station and tyre factory, and the same between flue gas and open burning. The further analysis showed that the linearly dependent coefficients of 1,2,3,7,8-PeCDD and 2,3,4,6,7,8-HxCDF were 0.95 and 0.75, respectively. It showed the strong correlation of two monomers in all ambient air samples. The PCA and cluster analysis showed that MSWI influenced the surrounding air, tyre factory had an impact on upwind station, and open burning had a lower effect on outdrop monitoring station.

2.
Huan Jing Ke Xue ; 36(10): 3596-602, 2015 Oct.
Article in Zh | MEDLINE | ID: mdl-26841590

ABSTRACT

To analysis the influencing factors for the emssions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) as structure of crematory, air pollution control device (APCD) and funeral objects, etc, we collected and measured the PCDD/Fs emissions in flue gas from 13 crematories in China. Then we proposed some supervision suggestions on measures of pollution control and management. The results indicated that the emission levels of PCDD/Fs (as the toxic equivalent concentration, TEQ) was ranged in a large gap from 0.027 to 15.8 ng x m(-3), and the average was 3.2 ng x m(-3). Emissions factor of PCDD/Fs (as TEQ) from 13 crematories varied between 45.9 and 22 236 ng x body(-1), and the average was 4 738 ng x body(-1). The emissions of PCDD/Fs from flat incinerators were generally lower, whereas higher ratio up to the national discharge standard, than that of car type incinerators. Congener distribution of PCDD/Fs in flue gas from 13 crematories were different from each other. Since the emission of PCDD/Fs from some crematories remains in high level, it is necessary to control pollution from the source, improve the pollution control technology, and strengthen government supervision, by following measures: 11 cremating funeral objects separately from corpse; 22 adding one


Subject(s)
Air Pollutants/analysis , Benzofurans/analysis , Cremation , Incineration , Polychlorinated Dibenzodioxins/analogs & derivatives , China , Dibenzofurans, Polychlorinated , Polychlorinated Dibenzodioxins/analysis
3.
Huan Jing Ke Xue ; 34(8): 3238-43, 2013 Aug.
Article in Zh | MEDLINE | ID: mdl-24191574

ABSTRACT

The concentration and profiles of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in the environmental air, soil and plant samples around a hospital solid waste incinerator (HSWI) in Northwest of China were determined by HRGC/HRMS, and the flue gas samples of the HSWI were also involved. The results showed that the average concentration (I-TEQ) of PCDD/Fs in the exhaust gas was 184 ng x m(-3), which seriously exceeds the emission standard (0.5 ng x m(-3)). And the average concentration of PCDD/ Fs was 7.30 pg x m(-3) in the ambient air samples, 52.5 pg x g(-1) in the soil samples, and 146 pg x g(-1) in the leaves samples. All of them were at quite high levels. The concentrations of PCDD/Fs in air samples of downwind were obviously higher than those of upwind. The concentration increased and then decreased with the increase of distance from the HSWI, and the highest concentration occurred at the distance of 700 m from the HSWI. The mass concentration (I-TEQ) proportional distributions of 2, 3, 7, 8 substitution toxic dioxins in downwind air and soil samples was similar to those in the exhaust gas samples. The analysis results of PCDD/Fs concentrations, profiles distributions and principal components all showed that the major source of PCDD/Fs in this area was from the HSWI flue gas emissions.


Subject(s)
Air Pollutants/analysis , Benzofurans/analysis , Environmental Monitoring , Polychlorinated Dibenzodioxins/analogs & derivatives , Soil Pollutants/analysis , China , Dibenzofurans, Polychlorinated , Incineration , Polychlorinated Dibenzodioxins/analysis , Soil/chemistry , Solid Waste
SELECTION OF CITATIONS
SEARCH DETAIL