Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Proc Jpn Acad Ser B Phys Biol Sci ; 98(6): 227-282, 2022.
Article in English | MEDLINE | ID: mdl-35691845

ABSTRACT

Presented here are the observations and interpretations from a comprehensive analysis of 16 representative particles returned from the C-type asteroid Ryugu by the Hayabusa2 mission. On average Ryugu particles consist of 50% phyllosilicate matrix, 41% porosity and 9% minor phases, including organic matter. The abundances of 70 elements from the particles are in close agreement with those of CI chondrites. Bulk Ryugu particles show higher δ18O, Δ17O, and ε54Cr values than CI chondrites. As such, Ryugu sampled the most primitive and least-thermally processed protosolar nebula reservoirs. Such a finding is consistent with multi-scale H-C-N isotopic compositions that are compatible with an origin for Ryugu organic matter within both the protosolar nebula and the interstellar medium. The analytical data obtained here, suggests that complex soluble organic matter formed during aqueous alteration on the Ryugu progenitor planetesimal (several 10's of km), <2.6 Myr after CAI formation. Subsequently, the Ryugu progenitor planetesimal was fragmented and evolved into the current asteroid Ryugu through sublimation.


Subject(s)
Meteoroids , Solar System , Water
2.
J Mass Spectrom ; 57(11): e4892, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36376098

ABSTRACT

We developed an autocorrelation function to resolve the overtaking problem in a multiturn time-of-flight mass spectrometer (TOF-MS). The function analyzes the characteristic period for one lap of each ion packet and derives a mass spectrum from a signal pulse train composed of multiturn ion packets. To detect the ion pulse train, a new nondestructive ion detector was developed and installed in the multiturn orbit of MULTUM-S II. This detector is composed of an electrostatically induced charge detector, a preamplifier, and a digitizer. The electrostatic noises are smaller than the single-ion signals owing to the accumulation of the multiturn TOF spectrum. The conventional ion detector of TOF-MS is operated after collecting the signal pulse train. The multiturn TOF spectrum was convolved with an autocorrelation function to derive the mass spectrum. The convolved mass spectrum performed a mass resolving power (MRP) of 28,200 at m/z 69 and mass accuracy of 28 ppm for the perfluorotributylamine (PFTBA) gas sample.


Subject(s)
Static Electricity , Mass Spectrometry
SELECTION OF CITATIONS
SEARCH DETAIL