Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
1.
Vet Anaesth Analg ; 48(1): 116-124, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33277182

ABSTRACT

OBJECTIVE: To compare the perioperative use of analgesics and complication rates in dogs administered an erector spinae plane (ESP) block or a traditional opioid-based (OP) treatment as part of analgesic management during hemilaminectomy. STUDY DESIGN: Retrospective cohort study. ANIMALS: Medical records of 114 client-owned dogs. METHODS: General data included demographics, duration of procedure, number of laminae fenestrated, perioperative use of steroid and non-steroidal anti-inflammatory drugs. Intra- and postoperative analgesics used in 48 hours and complications rates were compared between groups. Opioid use was expressed in morphine equivalents [ME (mg kg-1)]. Continuous data were compared using the Mann-Whitney U test and incidence of events with a Fisher's exact tests. Multiple linear regression was used to evaluate association between perioperative ME consumption (dependent variable) with other independent variables. Data are presented as median (range). Differences were considered significant when p < 0.05. RESULTS: Group ESP comprised 42 dogs and group OP 72 dogs. No differences were observed in the general data. Intraoperative ME was 0.65 (0.20-3.74) and 0.79 (0.19-5.60) mg kg-1 in groups ESP and OP, respectively (p = 0.03). Intraoperative infusion of lidocaine was administered intravenously (IV) to 23.8% and 68% of groups ESP and OP, respectively (p < 0.0001). Intraoperative infusion of ketamine was administered IV to 21% and 40% of groups ESP and OP, respectively (p = 0.04). Regression analysis revealed the ESP block as the only independent variable affecting the perioperative ME consumption. Pharmacological intervention to treat cardiovascular complications was administered to 21.4% and 47.2% of dogs in groups ESP and OP, respectively (p = 0.008). There were no differences in postoperative complication rates. CONCLUSIONS AND CLINICAL RELEVANCE: ESP block was associated with reduced perioperative opioid consumption, intraoperative adjuvant analgesic use and incidence of pharmacological interventions to treat cardiovascular complications in dogs undergoing hemilaminectomy.


Subject(s)
Dog Diseases , Nerve Block , Analgesics , Animals , Dogs , Nerve Block/veterinary , Pain, Postoperative/prevention & control , Pain, Postoperative/veterinary , Paraspinal Muscles , Retrospective Studies
2.
Vet Surg ; 49(3): 480-486, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32034924

ABSTRACT

OBJECTIVE: To compare the effectiveness of four different intestinal anastomosis techniques at preventing leakage after enterectomy. STUDY DESIGN: Experimental study. SAMPLE POPULATION: Grossly normal jejunal segments (N = 70) from three fresh canine cadavers. METHODS: Eight-centimeter cooled canine cadaveric jejunal segments were randomly assigned to a control group (six segments) and four treatment groups (16 segments each [two segments/anastomotic construct]): (1) handsewn anastomosis (HSA), (2) barbed suture anastomosis (B-HSA), (3) stapled functional end-to-end anastomosis (SFEEA), and (4) stapled functional end-to-end anastomosis with an oversew (SFEEA-O). Control segments and anastomotic constructs were infused intraluminally to the point of leakage. Initial leak pressures were recorded and compared. RESULTS: Initial leak pressures (median + range) for jejunal control segments, HSA, B-HSA, SFEEA, and SFEEA-O were 331.88 mmHg (range, 315.34-346.64), 35.17 (20.29-56.24), 24.99 (6.08-38.64), 28.77 (18.80-85.09), and 35.92 (12.05-80.71), respectively. No difference was detected between leak pressures of anastomosed segments (P = .35), all of which were more variable and lower than those of intact segments. CONCLUSION: No difference in initial leak pressures was detected between the four anastomosis techniques tested in cooled canine cadaveric jejunum. CLINICAL SIGNIFICANCE: All four anastomosis techniques evaluated in this study may be suitable in dogs.


Subject(s)
Anastomosis, Surgical/veterinary , Digestive System Surgical Procedures/veterinary , Jejunum/surgery , Anastomosis, Surgical/methods , Animals , Cadaver , Cold Temperature , Digestive System Surgical Procedures/methods , Dogs , Pressure , Random Allocation , Suture Techniques/veterinary
3.
Vet Anaesth Analg ; 47(2): 249-258, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32014397

ABSTRACT

OBJECTIVE: To describe a quadratus lumborum (QL) block technique in canine cadavers and the spread of injectate. STUDY DESIGN: Prospective, randomized, descriptive, experimental anatomic study. ANIMALS: A group of 12 adult canine cadavers. METHODS: Gross and ultrasound anatomy of the sublumbar musculature and the relationship with the spinal nerves was studied in two cadavers. Bilateral ultrasound-guided injections were performed in eight cadavers in the fascial plane between the QL and psoas muscle using a dye-lidocaine solution [low volume (LV) 0.15 mL kg-1 or high volume (HV) 0.3 mL kg-1]. The ultrasound transducer was positioned caudal and parallel to the proximal aspect of the last rib, and an insulated needle was introduced in-plane using a ventrolateral to dorsomedial approach. Dissections were performed to determine the number of spinal nerves successfully stained (>1 cm) and the presence of injectate in the epidural space or abdominal cavity. Additionally, two cadavers were transversally cryosectioned after QL injection. RESULTS: Ventral branches of the last thoracic and first three lumbar spinal nerves ran between the bundles of the QL muscle and between the QL and psoas muscles. The target fascial plane was ultrasonographically identified and filled with the dye solution following all injections. Ventral branches of the thirteenth thoracic and first, second and third lumbar nerves were stained by 0.0%, 71.4%, 100%, 100%, and 25%, 100%, 100%, 100% using LV and HV, respectively. Multisegmental spread stained the lumbar sympathetic trunk on 0 (0-3) and 3 (0-4) vertebral levels with LV and HV, respectively. No abdominal or epidural spread was identified. CONCLUSION AND CLINICAL RELEVANCE: Although no significant differences were found, HV resulted in a higher percentage of stain on spinal nerves and sympathetic trunk than LV. Further studies are warranted to determine if the QL block provides somatic and visceral abdominal analgesia in dogs.


Subject(s)
Coloring Agents/administration & dosage , Dogs , Lidocaine/administration & dosage , Nerve Block/veterinary , Ultrasonography, Interventional/veterinary , Animals , Cadaver , Coloring Agents/chemistry , Injections/veterinary , Lidocaine/chemistry , Lumbar Vertebrae/diagnostic imaging , Nerve Block/instrumentation , Nerve Block/methods , Spinal Nerves/diagnostic imaging
4.
Vet Anaesth Analg ; 47(2): 229-237, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31980367

ABSTRACT

OBJECTIVE: To investigate the distribution and nerve staining of two volumes of lidocaine-dye solution after ultrasound-guided erector spinae plane (ESP) injections in canine cadavers. STUDY DESIGN: Experimental cadaveric study. ANIMALS: A total of nine canine cadavers. METHODS: ESP injections were performed between the longissimus thoracis muscle and the dorsolateral edge of the ninth thoracic transverse process. Two cadavers were transversally cryosectioned after unilateral ESP injections [0.6 mL kg-1; high volume (HV)]. In seven cadavers, bilateral ESP injections with HV or low volume (0.3 mL kg-1; LV) were performed. Gadodiamide was added to the injectate for two cadavers and magnetic resonance imaging (MRI) was performed pre- and post-injection. Injectate distribution and nerve staining of the branches of the spinal nerves were recorded after gross anatomical dissection. The thoracic paravertebral and epidural spaces were examined for dye solution. RESULTS: Cryosections, MRI and gross dissections showed that the injectate spread dorsally to the transverse processes, over the ventromedial aspect of the longissimus thoracis muscle where the medial and lateral branches of the dorsal branches of the spinal nerves are located. LV and HV stained a median (range) of 4 (2-7) and 4 (3-8) medial branches, respectively (p = 0.52). LV and HV stained 4 (2-5) and 5 (4-7) lateral branches (p = 0.26), respectively. Ventral branches were not stained, and dye was not identified in the epidural or paravertebral spaces. CONCLUSIONS: and clinical relevance Medial and lateral branches were consistently stained over several spinal segments. The number of nerves stained was not different with HV or LV, and the ventral branches of the spinal nerves were not stained in any cadaver. ESP block may find a clinical application to desensitize structures innervated by the medial and lateral branches of the dorsal branches of the thoracic spinal nerves.


Subject(s)
Coloring Agents/administration & dosage , Dogs , Lidocaine/administration & dosage , Nerve Block/veterinary , Ultrasonography, Interventional/veterinary , Animals , Cadaver , Coloring Agents/chemistry , Injections/veterinary , Lidocaine/chemistry , Nerve Block/instrumentation , Nerve Block/methods , Spinal Nerves/diagnostic imaging , Thoracic Vertebrae/diagnostic imaging
5.
Circ Res ; 120(2): 312-323, 2017 Jan 20.
Article in English | MEDLINE | ID: mdl-27799253

ABSTRACT

RATIONALE: Sympathetic nervous system control of inflammation plays a central role in hypertension. The gut receives significant sympathetic innervation, is densely populated with a diverse microbial ecosystem, and contains immune cells that greatly impact overall inflammatory homeostasis. Despite this uniqueness, little is known about the involvement of the gut in hypertension. OBJECTIVE: Test the hypothesis that increased sympathetic drive to the gut is associated with increased gut wall permeability, increased inflammatory status, and microbial dysbiosis and that these gut pathological changes are linked to hypertension. METHODS AND RESULTS: Gut epithelial integrity and wall pathology were examined in spontaneously hypertensive rat and chronic angiotensin II infusion rat models. The increase in blood pressure in spontaneously hypertensive rat was associated with gut pathology that included increased intestinal permeability and decreased tight junction proteins. These changes in gut pathology in hypertension were associated with alterations in microbial communities relevant in blood pressure control. We also observed enhanced gut-neuronal communication in hypertension originating from paraventricular nucleus of the hypothalamus and presenting as increased sympathetic drive to the gut. Finally, angiotensin-converting enzyme inhibition (captopril) normalized blood pressure and was associated with reversal of gut pathology. CONCLUSIONS: A dysfunctional sympathetic-gut communication is associated with gut pathology, dysbiosis, and inflammation and plays a key role in hypertension. Thus, targeting of gut microbiota by innovative probiotics, antibiotics, and fecal transplant, in combination with the current pharmacotherapy, may be a novel strategy for hypertension treatment.


Subject(s)
Gastrointestinal Microbiome/physiology , Hypertension/metabolism , Hypertension/physiopathology , Intestinal Mucosa/metabolism , Intestinal Mucosa/physiopathology , Angiotensin II/toxicity , Angiotensin-Converting Enzyme Inhibitors/pharmacology , Angiotensin-Converting Enzyme Inhibitors/therapeutic use , Animals , Gastrointestinal Microbiome/drug effects , Hypertension/drug therapy , Intestinal Mucosa/drug effects , Male , Permeability/drug effects , Rats , Rats, Inbred SHR , Rats, Inbred WKY , Rats, Sprague-Dawley , Rats, Wistar
6.
Vet Anaesth Analg ; 45(5): 703-706, 2018 Sep.
Article in English | MEDLINE | ID: mdl-29908716

ABSTRACT

OBJECTIVE: To investigate the utility of identifying the superficial circumflex iliac artery (SCIA) via ultrasound as an anatomical landmark for ultrasound-guided femoral nerve block. STUDY DESIGN: Observational study. ANIMALS: A group of six canine cadavers weighing >20 kg. METHODS: Pelvic limbs from six canine cadavers were examined to study the relationship between the SCIA and the femoral nerve. Ultrasonographic imaging of the SCIA in each limb was obtained with the transducer placed transversely in the medial aspect of the pelvic limb at the inguinal area. Subsequently, a needle was inserted in close proximity to the femoral nerve using an in-plane technique based on the anatomical relationship between the SCIA and femoral nerve. A total of 0.1 mL of colored latex was then injected at the location where the femoral nerve was expected to be in relationship to the SCIA. Gross dissection of the inguinal region in each pelvic limb was performed after injection. Positive nerve location was defined when the colored latex was in contact with the femoral nerve. RESULTS: A total of eleven pelvic limbs were injected because the SCIA could not be successfully visualized in one limb. Upon dissection, colored latex was found to be in direct contact with the femoral nerve in all 11 injected limbs. CONCLUSIONS AND CLINICAL RELEVANCE: We concluded that the ultrasonographic visualization of the SCIA assisted in the accurate deposition of dye in proximity to the femoral nerve of canine cadavers. Further investigation will determine the efficacy of this technique for performing femoral nerve blocks.


Subject(s)
Dogs/anatomy & histology , Femoral Nerve/diagnostic imaging , Iliac Artery/diagnostic imaging , Nerve Block/veterinary , Ultrasonography, Interventional/veterinary , Anatomic Landmarks/anatomy & histology , Anatomic Landmarks/diagnostic imaging , Animals , Femoral Nerve/anatomy & histology , Iliac Artery/anatomy & histology , Nerve Block/methods , Ultrasonography, Interventional/methods
7.
Vet Anaesth Analg ; 45(4): 566-574, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29793780

ABSTRACT

OBJECTIVE: To evaluate an ultrasound-guided technique for adductor canal (AC) block by describing the distribution of methylene blue around the AC, popliteal fossa, saphenous, tibial and common fibular nerves in dog cadavers. STUDY DESIGN: Prospective experimental trial. ANIMALS: Ten mixed breed canine cadavers weighing 28.55 ± 3.94 kg. METHODS: Ultrasound scans of the AC were performed bilaterally in 10 canine cadavers. A high-frequency linear transducer was placed on the long axis of the pectineus muscle and using an in-plane technique, an insulated needle was introduced at a proximal to distal direction into the AC. Methylene blue 0.1% (0.3 mL kg-1) was administered followed by dissection. The presence of dye over the target nerves for ≥2 cm was considered successful distribution. Three of 10 cadavers were submitted to computed tomography (CT) and one of them to magnetic resonance (MR) evaluation. RESULTS: Methylene blue reached the AC in 20 (100%) and the popliteal fossa in 17 (85%) pelvic limbs. Staining was successful in the saphenous nerve (4.0 ± 1.57 cm) in 11 (55%) limbs, tibial nerve (2.65 ± 0.8 cm) in six (30%) and common fibular nerve (2.7 ± 0.9 cm) in four (20%). There was no evidence of staining around the motor branches of the femoral nerve. No intraneural or intravascular dye spread was found during dissections. Contrast distribution to the popliteal fossa was observed in three limbs (50%) in CT and in one (50%) MR image. CONCLUSIONS AND CLINICAL RELEVANCE: Although the tibial and common fibular nerves were not stained as often as the saphenous nerve, dye was encountered throughout the popliteal fossa near the nerves. The AC block may be useful for intra and postoperative analgesia in stifle surgery with minimal femoral motor dysfunction. However, further study is required to confirm its efficacy and safety in vivo.


Subject(s)
Nerve Block/veterinary , Ultrasonography, Interventional/veterinary , Animals , Dogs , Female , Lower Extremity/diagnostic imaging , Lower Extremity/innervation , Male , Nerve Block/methods , Peroneal Nerve/diagnostic imaging , Tibial Nerve/diagnostic imaging , Ultrasonography, Interventional/methods
8.
Circ Res ; 117(2): 178-91, 2015 Jul 03.
Article in English | MEDLINE | ID: mdl-25963715

ABSTRACT

RATIONALE: Microglial activation in autonomic brain regions is a hallmark of neuroinflammation in neurogenic hypertension. Despite evidence that an impaired sympathetic nerve activity supplying the bone marrow (BM) increases inflammatory cells and decreases angiogenic cells, little is known about the reciprocal impact of BM-derived inflammatory cells on neuroinflammation in hypertension. OBJECTIVE: To test the hypothesis that proinflammatory BM cells from hypertensive animals contribute to neuroinflammation and hypertension via a brain-BM interaction. METHODS AND RESULTS: After BM ablation in spontaneously hypertensive rats, and reconstitution with normotensive Wistar Kyoto rat BM, the resultant chimeric spontaneously hypertensive rats displayed significant reduction in mean arterial pressure associated with attenuation of both central and peripheral inflammation. In contrast, an elevated mean arterial pressure along with increased central and peripheral inflammation was observed in chimeric Wistar-Kyoto rats reconstituted with spontaneously hypertensive rat BM. Oral treatment with minocycline, an inhibitor of microglial activation, attenuated hypertension in both the spontaneously hypertensive rats and the chronic angiotensin II-infused rats. This was accompanied by decreased sympathetic drive and inflammation. Furthermore, in chronic angiotensin II-infused rats, minocycline prevented extravasation of BM-derived cells to the hypothalamic paraventricular nucleus, presumably via a mechanism of decreased C-C chemokine ligand 2 levels in the cerebrospinal fluid. CONCLUSIONS: The BM contributes to hypertension by increasing peripheral inflammatory cells and their extravasation into the brain. Minocycline is an effective therapy to modify neurogenic components of hypertension. These observations support the hypothesis that BM-derived cells are involved in neuroinflammation, and targeting them may be an innovative strategy for neurogenic resistant hypertension therapy.


Subject(s)
Bone Marrow Cells/physiology , Hypertension/etiology , Microglia/physiology , Neurogenic Inflammation/complications , Paraventricular Hypothalamic Nucleus/physiopathology , Sympathetic Nervous System/physiopathology , Angiotensin II , Animals , Baroreflex/physiology , Bone Marrow Transplantation , Chemokine CCL2/biosynthesis , Chemokine CCL2/genetics , Female , Hypertension/physiopathology , Hypertension/prevention & control , Interleukin-1beta/biosynthesis , Interleukin-1beta/genetics , Male , Microglia/drug effects , Minocycline/therapeutic use , Norepinephrine/blood , Paraventricular Hypothalamic Nucleus/immunology , Radiation Chimera , Rats , Rats, Inbred SHR , Rats, Inbred WKY , Sympathetic Nervous System/drug effects , T-Lymphocyte Subsets/immunology
9.
Vet Anaesth Analg ; 44(3): 502-508, 2017 May.
Article in English | MEDLINE | ID: mdl-28539183

ABSTRACT

OBJECTIVE: To measure intraocular pressure (IOP) in horses during hoisting after induction of anesthesia. STUDY DESIGN: Prospective nonrandomized clinical study. ANIMALS: Eighteen healthy adult horses aged [mean±standard deviation (SD)] 10±4.2 years and weighing 491±110 kg anesthetized for elective procedures. METHODS: IOP was measured in the superior eye of each horse based on planned recumbency after induction of anesthesia. Measurements were taken directly after premedication with xylazine or detomidine with butorphanol, after induction with diazepam-ketamine, after intubation, when suspended by the hoist and on the operating table. During hoisting, the head was supported and the eye-heart height was measured to account for variations in head positioning among patients. IOPs were compared across time points using repeated-measures analysis of variance. Regression was used to compare IOP outcome with potential cofactors. RESULTS: Compared with measurements after premedication (17.5±2.5 mmHg) (mean±SD), hoisting significantly increased IOP (32.4±15.3 mmHg) (p<0.01). The highest recorded IOP in the hoist was 80.0 (range, 16.0-80.0) mmHg. The difference in IOP between premedication and hoisting was 15.0±16.2 (range, -1.0 to 68.0) mmHg. Body weight had a significant effect on absolute IOP and change in IOP in the hoist (p<0.01). CONCLUSIONS AND CLINICAL RELEVANCE: Hoist IOP was significantly higher than post-premedication IOP with heavier horses having higher hoist IOPs and greater increases in IOP. The clinician should take this relationship into account when anesthetizing and hoisting larger horses where an increase in IOP could be detrimental.


Subject(s)
Anesthesia/veterinary , Intraocular Pressure/physiology , Moving and Lifting Patients/veterinary , Animals , Elective Surgical Procedures/veterinary , Horses , Ketamine , Moving and Lifting Patients/adverse effects , Preanesthetic Medication , Prospective Studies , Tonometry, Ocular/veterinary , Xylazine
10.
Vet Anaesth Analg ; 43(6): 662-669, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27109568

ABSTRACT

OBJECTIVES: To evaluate perfusion index (PI) as a determinant of regional nerve block success following sciatic nerve blockade with bupivacaine in dogs undergoing stifle surgery. STUDY DESIGN: Prospective clinical trial. ANIMALS: Ten adult dogs, aged 5.6 ± 2.6 years and weighing 36.9 ± 16.8 kg, undergoing a tibial plateau leveling osteotomy. METHODS: Dogs were premedicated with acepromazine (0.03 mg kg-1 ) and hydromorphone (0.1 mg kg-1 ) intramuscularly, and anesthetized with propofol (up to 4 mg kg-1 ) intravenously and isoflurane in oxygen. An ultrasound-guided femoral and sciatic (F+S) nerve block was performed on the surgical limb with bupivacaine (0.75%), 0.2 mL kg-1 at the femoral site and 0.3 mL kg-1 at the sciatic site, with a maximum volume of 10 mL per site. Physiological variables were recorded every 5 minutes throughout anesthesia. A pulse co-oximeter probe was placed between the third and fourth digits of both pelvic limbs, and the PI was recorded 5 minutes before infiltration with bupivacaine, immediately afterwards, and every 5 minutes for 30 minutes. Motor nerve conduction velocity (MNCV) of the sciatic nerve was performed on the surgical limb 5 minutes before and 20 minutes after bupivacaine administration to confirm nerve block. RESULTS: The PI of the surgical limb was significantly greater than the contralateral pelvic limb at 10 minutes (p = 0.03) and 15 minutes (p < 0.01) after F+S nerve blockade. The MNCV performed after sciatic nerve blockade revealed a functional motor blockade for all dogs. There were no significant changes in physiological variables. CONCLUSIONS AND CLINICAL RELEVANCE: The PI provided a reliable indication of successful sciatic nerve blockade in the clinical patients in this study. No increase in the PI by 15 minutes after bupivacaine administration around the sciatic nerve could indicate partial or total failure of anesthetic blockade.


Subject(s)
Anesthetics, Local/administration & dosage , Bupivacaine/administration & dosage , Dogs/surgery , Nerve Block/veterinary , Animals , Female , Male , Osteotomy/veterinary , Oximetry/veterinary , Prospective Studies , Regional Blood Flow/drug effects , Sciatic Nerve
11.
Can Vet J ; 57(1): 59-64, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26740699

ABSTRACT

This study evaluated the safety of preoperative computed tomography angiography (CTA) and its effect on surgical time and clinical outcomes in dogs that underwent surgical correction of a single congenital extrahepatic portosystemic shunt (CEPSS). Patient data were retrospectively collected from medical records and owner communications for 124 dogs with single CEPSS, undergoing preoperative CTA (n = 43) or not (n = 81) which were surgically treated from 2005 to 2014. The frequency of major postoperative complications was 4.7% and 9.9% for the CTA and no CTA groups, respectively (P = 0.49). Mean ± standard deviation (SD) surgical time for the preoperative CTA group was 84 ± 40 min and 81 ± 31 min for the no CTA group (P = 0.28). We conclude that anesthetized preoperative CTA appears to be a safe method for diagnosis and surgical planning in dogs with single CEPSS, and does not appear to affect surgical procedure time, complication rate, or clinical outcome.


Évaluation des résultats chirurgicaux, des complications et de la mortalité chez les chiens subissant une angiographie par tomodensitométrie préopératoire pour le diagnostic d'un shunt portosystémique extrahépatique : 124 cas (2005­2014). Cette étude a évalué l'innocuité d'une angiographie par tomodensitométrie (AT) préopératoire et son effet sur la durée de la chirurgie et les résultats cliniques chez les chiens qui avaient subi la correction chirurgicale d'un shunt portosystémique extrahépatique congénital simple (SPSEHC). Les données des patients ont été recueillies rétrospectivement dans les dossiers médicaux et lors de communications avec les propriétaires pour 124 chiens atteints d'un SPSEHC simple, qui subissaient une AT préopératoire (n = 43) ou non (n = 81), et qui avaient été traités par chirurgie entre 2005 et 2014. La fréquence des complications postopératoires majeures était de 4,7 % et de 9,9 % pour les groupes AT et sans AT, respectivement (P = 0,49). La durée moyenne ± SD de la chirurgie pour le groupe d'AT préopératoire était de 84 ± 40 minutes et de 81 ± 31 minutes pour le groupe sans AT (P = 0,28). Nous avons conclu que l'AT préopératoire semble être une méthode sûre pour le diagnostic et la planification chirurgicale des chiens ayant un SPSEHC simple et qu'elle ne semble pas affecter la durée de l'intervention, le taux de complication ou les résultats cliniques.(Traduit par Isabelle Vallières).


Subject(s)
Angiography/veterinary , Dog Diseases/diagnostic imaging , Portal System/abnormalities , Postoperative Complications/veterinary , Tomography, X-Ray Computed/veterinary , Angiography/methods , Animals , Dog Diseases/surgery , Dogs , Female , Male , Portal System/surgery , Preoperative Care/methods , Retrospective Studies , Tomography, X-Ray Computed/methods , Treatment Outcome
12.
Vet Anaesth Analg ; 42(1): 99-102, 2015 Jan.
Article in English | MEDLINE | ID: mdl-24735018

ABSTRACT

OBJECTIVE: To determine if the transesophageal atrial (A) wave amplitude or ventricular (V) wave amplitude can be used to guide optimal positioning of a transesophageal pacing catheter in dogs. STUDY DESIGN: Prospective clinical study. ANIMALS: Fourteen client owned healthy dogs with a median weight of 15.4 kg (IQR = 10.6-22.4) and a median age of 12 months (IQR = 6-12). MATERIALS AND METHODS: Transesophageal atrial pacing (TAP) using a 6 Fr pacing catheter was attempted in dogs under general anesthesia. The pacing catheter was inserted orally into the esophagus to a position caudal to the heart. With the pulse generator set at a rate 20 beats/minute(-1) above the intrinsic sinus rate, the catheter was slowly withdrawn until atrial pacing was noted on a surface electrocardiogram (ECG). Then the catheter was withdrawn in 1 cm increments until atrial capture was lost. Minimum pacing threshold (MPT) and transesophageal ECG were recorded at each site. Amplitudes of the A and V waves on transesophageal ECG were then measured and their relationship to MPT was evaluated. RESULTS: TAP was achieved in all dogs. In 9/14 dogs the site of lowest overall MPT was the same as the site of maximal A wave deflection. In dogs with at least three data points, linear regression analysis of the relationship between the estimated site of the lowest overall MPT compared to estimated site of the maximal A and V waveform amplitudes demonstrated a strong correlation (R(2) = 0.99). CONCLUSION AND CLINICAL RELEVANCE: Transesophageal ECG A and V waveforms were correlated to MPT and could be used to direct the placement of a pacing catheter. However, the technique was technically challenging and was not considered to be clinically useful to guide the placement of a pacing catheter.


Subject(s)
Catheters/veterinary , Dogs , Electrocardiography/veterinary , Esophagus , Animals , Cardiac Pacing, Artificial/methods , Cardiac Pacing, Artificial/veterinary , Electrocardiography/methods , Pacemaker, Artificial/veterinary
13.
Vet Clin North Am Equine Pract ; 30(1): 1-17, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24680204

ABSTRACT

Morbidity and mortality rate in equine anesthesia is still unacceptably high. Thus it is critical contemplating whether the benefit of general anesthesia for a specific patient and procedure outweighs the risks. Sedative protocols that would allow performing diagnostic and surgical procedures with the patient remaining standing would therefore be ideal. Infusion of short-acting agents allows to rapidly achieve a titratable steady state of sedation. Supplementing sedatives and tranquilizers with systemic analgesic or regional anesthetic techniques (i.e. epidurals) facilitates standing surgical procedures. Multimodal analgesia would also provide superior analgesia with potentially fewer side effects than a single agent approach.


Subject(s)
Analgesia/veterinary , Anesthesia, General/veterinary , Horse Diseases/surgery , Horses/surgery , Surgical Procedures, Operative/veterinary , Adrenergic alpha-2 Receptor Agonists/therapeutic use , Analgesia/methods , Anesthesia, General/methods , Animals , Female , Pain Management/veterinary , Pain, Postoperative/drug therapy , Pain, Postoperative/prevention & control , Pain, Postoperative/veterinary , Pregnancy
14.
Vet Anaesth Analg ; 40(5): 546-50, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23742668

ABSTRACT

OBJECTIVE: To evaluate the accuracy of epidural catheter placement at different levels of the spinal cord guided solely by electrical nerve stimulation and resultant segmental muscle contraction. STUDY DESIGN: Prospective, experiment. ANIMALS: Six male and two female Beagles, age (1 ± 0.17 years) and weight (12.9 ± 1.1 kg). METHODS: Animals were anesthetized with propofol and maintained with isoflurane. An insulated epidural needle was used to reach the lumbosacral epidural space. A Tsui epidural catheter was inserted and connected to a nerve stimulator (1.0 mA, 0.1 ms, 2 Hz) to assess positioning of the tip at specific spinal cord segments. The catheter was advanced to three different levels of the spinal cord: lumbar (L2-L5), thoracic (T5-T10) and cervical (C4-C6). Subcutaneous needles were previously placed at these spinal levels and the catheter was advanced to match the needle location, guided only by corresponding muscle contractions. Catheter position was verified by fluoroscopy. If catheter tip and needle were at the same vertebral body a score of zero was assigned. When catheter tip was cranial or caudal to the needle, positive or negative numbers, respectively, corresponding to the number of vertebrae between them, were assigned. The mean and standard deviation of the number of vertebrae between catheter tip and needle were calculated to assess accuracy. Results are given as mean ± SD. RESULTS: The catheter position in relation to the needle was within 0.3 ± 2.0 vertebral bodies. Positive predictive values (PPV) were 57%, 83% and 71% for lumbar, thoracic and cervical regions respectively. Overall PPV was 70%. No significant difference in PPV among regions was found. CONCLUSION AND CLINICAL RELEVANCE: Placement of an epidural catheter at specific spinal levels using electrical nerve stimulation was feasible without radiographic assistance in dogs. Two vertebral bodies difference from the target site may be clinically acceptable when performing segmental epidural regional anesthesia.


Subject(s)
Anesthesia, Epidural/veterinary , Catheterization/veterinary , Dogs/physiology , Electric Stimulation/methods , Anesthesia, Epidural/methods , Animals , Catheterization/methods , Female , Male
15.
Animals (Basel) ; 13(14)2023 Jul 20.
Article in English | MEDLINE | ID: mdl-37508139

ABSTRACT

Numerous cardiac output (CO) technologies were developed to replace the 'gold standard' pulmonary artery thermodilution due to its invasiveness and the risks associated with it. Minimally invasive lithium dilution (LiD) shows excellent agreement with thermodilution and can be used as a reference standard in animals. This study evaluated CO via noninvasive electrical cardiometry (EC) and acquired hemodynamic variables against CO measured using LiD in six healthy, anesthetized dogs administered different treatments (dobutamine, esmolol, phenylephrine, and high-dose isoflurane) impacting CO values. These treatments were chosen to cause drastic variations in CO, so that fair comparisons between EC and LiD across a wide range of CO values (low, intermediate, and high) could be made. Statistical analysis included linear regression, Bland-Altman plots, Lin's concordance correlation coefficient (ρc), and polar plots. Values of p < 0.05 represented significance. Good agreement was observed between EC and LiD, but consistent underestimation was noted when the CO values were high. The good trending ability, ρc of 0.88, and low percentage error of ±31% signified EC's favorable performance. Other EC-acquired variables successfully tracked changes in CO measured using LiD. EC may be a pivotal hemodynamic tool for continuously monitoring circulatory changes, as well as guiding and treating cardiovascular anesthetic complications in clinical settings.

16.
Am J Vet Res ; 83(6)2022 May 08.
Article in English | MEDLINE | ID: mdl-35524964

ABSTRACT

OBJECTIVE: To evaluate cardiac output (CO) measurements using transpulmonary ultrasound (TPUD) technology and compare results with those of the gold standard, pulmonary arterial catheter thermodilution (PACTD), in 6 healthy anesthetized pigs during acute hemodynamic changes caused by manipulation of the blood volume. ANIMALS: 6 healthy male Landrace pigs. PROCEDURES: Over a period of 1 week, pigs were anesthetized with isoflurane, mechanically ventilated, and underwent instrumentation in dorsal recumbency. They were subjected to sequential experimental states during which the blood volume was manipulated so that the animals transitioned from normovolemia to hypovolemia (20% and 40% of blood volume depletion), back to normovolemia (autologous blood transfusion), and then to hypervolemia (following colloid bolus). During each volume state, CO measurements were compared between TPUD and PACTD. RESULTS: The mean ± SD relative bias between TPUD and PACTD was 7.71% ± 21.2% with limits of agreement -33.9% to 49.3%, indicating TPUD slightly underestimated CO values, compared with values obtained with PACTD. The mean ± SD of the bias between the 2 methods was 0.13 ± 0.5 L/min. Only 5 of 36 (13.9%) TPUD CO measurements had an absolute value of relative bias > 30%. The percentage error calculated for TPUD was 29.4%. CLINICAL RELEVANCE: Results suggested that TPUD measurements have acceptable agreement with PACTD measurements. Moreover, TPUD exhibits promising potential in being used interchangeably with PACTD for future hemodynamic research involving swine as species of interest.


Subject(s)
Swine Diseases , Thermodilution , Animals , Cardiac Output , Hemodynamics , Hypovolemia/veterinary , Male , Pulmonary Artery/diagnostic imaging , Swine , Thermodilution/veterinary , Ultrasonography/methods , Ultrasonography/veterinary
17.
Am J Vet Res ; 71(2): 157-60, 2010 Feb.
Article in English | MEDLINE | ID: mdl-20113222

ABSTRACT

OBJECTIVE: To determine the minimal electric threshold (MET) of neurostimulation in and out of the lumbosacral epidural space necessary to cause muscle contraction of the hind limb or tail, determine an MET cutoff value that indicates epidural needle placement, and compare predictability of epidural needle placement attained by use of neurostimulation versus the standard technique that uses loss of resistance in dogs. ANIMALS: 96 healthy Beagles. PROCEDURES: Dogs received nonionic contrast medium (90 mg/kg) either in or out of the epidural space. Correct placement of the needle was evaluated by use of neurostimulation and loss of resistance of injection and confirmed by use of epidurography. RESULTS: With the neurostimulator test, MET was significantly lower in dogs with needle placement in the epidural space (mean +/- SEM, 0.30 +/- 0.07 mA) than those with needle placement out of the epidural space (1.2 +/- 0.13 mA). When an electric current cutoff of < or = 0.28 mA for the neurostimulator test was used to suggest correct needle placement in the lumbosacral epidural space, sensitivity and specificity were 74% and 93%, respectively. The loss of resistance test had sensitivity of 63% and specificity of 90%. The combination of both tests yielded a sensitivity of 89% and specificity of 83%. CONCLUSIONS AND CLINICAL RELEVANCE: Neurostimulation is a useful tool to suggest correct lumbosacral epidural needle placement in dogs.


Subject(s)
Dogs , Electric Stimulation , Injections, Epidural/veterinary , Lumbosacral Region , Muscle Contraction , Analgesia, Epidural/instrumentation , Animals , Catheterization/instrumentation , Contrast Media/administration & dosage , Contrast Media/pharmacology , Female , Iohexol/administration & dosage , Iohexol/pharmacology , Male , Muscle, Skeletal
18.
Am J Vet Res ; 81(10): 827-831, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32969730

ABSTRACT

OBJECTIVE: To compare initial leak pressure (ILP) between cadaveric canine and synthetic small intestinal segments that did and did not undergo enterotomy. SAMPLE: Eight 8-cm grossly normal jejunal segments from 1 canine cadaver and eight 8-cm synthetic small intestinal segments. PROCEDURES: Intestinal segments were randomly assigned to undergo enterotomy (6 cadaveric and 6 synthetic segments) or serve as untreated controls (2 cadaveric and 2 synthetic segments). For segments designated for enterotomy, a 2-cm full-thickness incision was created along the antimesenteric border. The incision was closed in a single layer with 4-0 suture in a simple continuous pattern. Leak testing was performed with intestinal segments occluded at both ends and infused with dilute dye solution (999 mL/h) until the solution was observed leaking from the suture line or serosal tearing occurred. Intraluminal pressure was continuously monitored. The ILP at construct failure was compared between cadaveric and synthetic control segments and between cadaveric and synthetic enterotomy segments. RESULTS: Mean ± SD ILP did not differ significantly between cadaveric (345.11 ± 2.15 mm Hg) and synthetic (329.04 ± 24.69 mm Hg) control segments but was significantly greater for cadaveric enterotomy segments (60.77 ± 15.81 mm Hg), compared with synthetic enterotomy segments (15.03 ± 6.41 mm Hg). CONCLUSIONS AND CLINICAL RELEVANCE: Leak testing should not be used to assess the accuracy or security of enterotomy suture lines in synthetic intestinal tissue. Synthetic intestinal tissue is best used for students to gain confidence and proficiency in performing enterotomies before performing the procedure on live animals.


Subject(s)
Digestive System Surgical Procedures/veterinary , Dog Diseases , Anastomosis, Surgical/veterinary , Animals , Cadaver , Dogs , Pressure , Suture Techniques/veterinary , Sutures
19.
Am J Vet Res ; 81(9): 747-754, 2020 Sep.
Article in English | MEDLINE | ID: mdl-33112170

ABSTRACT

OBJECTIVE: To determine the optimal energy profile for and to assess the feasibility and efficacy of ultrasonographic and laparoscopic guidance for microwave ablation (MWA) of clinically normal canine ovaries. SAMPLE: 44 extirpated ovaries from 22 healthy dogs. PROCEDURES: In the first of 2 trials, 13 dogs underwent oophorectomy by routine laparotomy. Extirpated ovaries underwent MWA at 45 W for 60 (n = 11) or 90 (12) seconds; 3 ovaries did not undergo MWA and served as histologic controls. Ovaries were histologically evaluated for cell viability. Ovaries without viable cells were categorized as completely ablated. Histologic results were used to identify the optimal MWA protocol for use in the subsequent trial. In the second trial, the ovaries of 9 dogs underwent MWA at 45 W for 90 seconds in situ. Ultrasonographic guidance for MWA was deemed unfeasible after evaluation of 1 ovary. The remaining 17 ovaries underwent MWA with laparoscopic guidance, after which routine laparoscopic oophorectomy was performed. Completeness of ablation was histologically assessed for all ovaries. RESULTS: 2 ovaries were excluded from the trial 1 analysis because of equivocal cell viability. Six of 11 ovaries and 10 of 10 ovaries that underwent MWA for 60 and 90 seconds, respectively, were completely ablated. In trial 2, laparoscopic-guided MWA resulted in complete ablation for 12 of 17 ovaries. Dissection of the ovarian bursa for MWA probe placement facilitated complete ablation. CONCLUSIONS AND CLINICAL RELEVANCE: Laparoscopic-guided MWA at 45 W for 90 seconds was feasible, safe, and effective for complete ablation of clinically normal ovaries in dogs.


Subject(s)
Catheter Ablation , Laparoscopy , Animals , Catheter Ablation/veterinary , Dogs , Feasibility Studies , Female , Laparoscopy/veterinary , Microwaves , Ovary/diagnostic imaging , Ovary/surgery , Radiofrequency Ablation/veterinary , Treatment Outcome
20.
Am J Vet Res ; 80(1): 24-32, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30605039

ABSTRACT

OBJECTIVE To evaluate the use of a modified passive leg-raising maneuver (PLRM) to predict fluid responsiveness during experimental induction and correction of hypovolemia in isoflurane-anesthetized pigs. ANIMALS 6 healthy male Landrace pigs. PROCEDURES Pigs were anesthetized with isoflurane, positioned in dorsal recumbency, and instrumented. Following induction of a neuromuscular blockade, pigs were mechanically ventilated throughout 5 sequential experimental stages during which the blood volume was manipulated so that subjects transitioned from normovolemia (baseline) to hypovolemia (blood volume depletion, 20% and 40%), back to normovolemia, and then to hypervolemia. During each stage, hemodynamic variables were measured before and 3 minutes after a PLRM and 1 minute after the pelvic limbs were returned to their original position. The PLRM consisted of raising the pelvic limbs and caudal portion of the abdomen to a 15° angle relative to the horizontal plane. RESULTS Hemodynamic variables did not vary in response to the PLRM when pigs were normovolemic or hypervolemic. When pigs were hypovolemic, the PLRM resulted in a significant increase in cardiac output and decrease in plethysomographic variability index and pulse pressure variation. When the pelvic limbs were returned to their original position, cardiac output and pulse pressure variation rapidly returned to their pre-PLRM values, but the plethysomographic variability index did not. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested a modified PLRM might be useful for identification of hemodynamically unstable animals that are likely to respond to fluid therapy. Further research is necessary to validate the described PLRM for prediction of fluid responsiveness in clinically ill animals.


Subject(s)
Anesthesia/veterinary , Anesthetics, Inhalation/pharmacology , Cardiac Output/drug effects , Isoflurane/pharmacology , Posture , Swine/physiology , Animals , Hemodynamics/drug effects , Hypovolemia/physiopathology , Hypovolemia/veterinary , Intraoperative Complications/physiopathology , Intraoperative Complications/veterinary , Male
SELECTION OF CITATIONS
SEARCH DETAIL