Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Catheter Cardiovasc Interv ; 104(2): 408-415, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38922752

ABSTRACT

As the general population ages, the incidence of degenerative mitral stenosis (MS) among patients has increased. Percutaneous mitral valvuloplasty (PMV) has emerged as a well-established option for mitral rheumatic stenosis with specific characteristics. However, a blank therapeutic space must be filled with the treatment options for degenerative or rheumatic mitral stenosis in patients with many comorbidities and contraindication for valvuloplasty. We here present a comprehensive overview of the current possibilities, despite their scarce success. That is the reason why we propose a case series to facilitate a better understanding of our innovative technique in this challenging clinical context.


Subject(s)
Balloon Valvuloplasty , Mitral Valve Stenosis , Mitral Valve , Humans , Mitral Valve Stenosis/diagnostic imaging , Mitral Valve Stenosis/physiopathology , Mitral Valve Stenosis/therapy , Mitral Valve Stenosis/surgery , Treatment Outcome , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve/surgery , Female , Male , Aged , Middle Aged , Cardiac Catheters , Equipment Design , Hemodynamics
2.
Echocardiography ; 41(6): e15861, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38853674

ABSTRACT

BACKGROUND: Transesophageal echocardiography (TEE) is primarily used to guide transcatheter structural heart interventions, such as tricuspid transcatheter edge-to-edge repair (TEER). Although TEE has a good safety profile, it is still an invasive imaging technique that may be associated with complications, especially when performed during long transcatheter procedures or on frail patients. The aim of this study was to assess TEE-related complications during tricuspid TEER. METHODS: This is a prospective study enrolling 53 patients who underwent tricuspid TEER for severe tricuspid regurgitation (TR). TEE-related complications were assessed clinically and divided into major (life-threatening, major bleeding requiring transfusions or surgery, organ perforation, and persistent dysphagia) and minor (perioral hypesthesia, < 24 h dysphagia/odynophagia, minor intraoral bleeding and hematemesis not requiring transfusion) RESULTS: The median age of the patient population was 79 years; 43.4% had severe, 39.6% massive, and 17.6% torrential TR. 62.3% of patients suffered from upper gastrointestinal disorders. Acute procedural success (APS) was achieved in 88.7% in a median device time of 36 min. A negative association was shown between APS and lead-induced etiology (r = -.284, p = .040), baseline TR grade (r = -.410, p = .002), suboptimal TEE view (r = -.349, p = .012), device time (r = -.234, p = .043), and leaflet detachment (r = -.496, p < .0001). We did not observe any clinical manifest major or minor TEE-related complications during the hospitalization. CONCLUSIONS: Our study reinforces the good safety profile and efficacy of TEE guidance during tricuspid TEER. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious complications. Furthermore, suboptimal intraprocedural TEE views are associated with lower TR reduction rates. HIGHLIGHTS: Transesophageal echocardiography is a crucial and safe technique for guiding transcatheter structural heart interventions. A mix of mid/deep esophageal and trans gastric views, as well as real-time 3D imaging is generally used to guide the procedure. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious problems. A shorter device time is associated with more rarely probe-related complications. Suboptimal intraprocedural TEE views are associated with lower TR reduction rates.


Subject(s)
Echocardiography, Transesophageal , Tricuspid Valve Insufficiency , Tricuspid Valve , Humans , Echocardiography, Transesophageal/methods , Female , Male , Prospective Studies , Tricuspid Valve Insufficiency/surgery , Aged , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Treatment Outcome , Aged, 80 and over
3.
Article in English | MEDLINE | ID: mdl-39450711

ABSTRACT

AIMS: Our study aims to evaluate the acute remodeling of the tricuspid valve annulus immediately after the T-TEER by using intraprocedural transesophageal three-dimensional (3D) echocardiography. METHODS AND RESULTS: We prospectively enrolled 62 consecutive symptomatic patients with at least severe TR, who underwent T-TEER with the TriClip System between March 2021 and June 2024. The following parameters were assessed using a multiplanar reconstruction analysis performed off-line using a 3D dataset: septal-lateral (SL) and antero-posterior (AP) annulus diameters; annulus area; annulus perimeter and eccentricity index.The acute procedural success was achieved in 85,5%. We observed an acute reduction in SL (from a median of 43 to 38 mm, p<0,0001), AP (from a median of 46 to 45 mm, p<0,0001), area (from a median of 17,9 to 15,95 cm2, p<0,0001), perimeter (from a median of 145,5 to 137 mm, p<0,0001) and eccentricity index (from 0,92 to 0,87, p<0,0001). The TV annulus was progressively larger in patients with higher residual TR. Analysis of the subgroups according to procedural success showed an acute inverse remodeling of the TV annulus independent of the acute procedural success. CONCLUSIONS: The TV geometry necessitates the use of 3D echocardiography for accurate assessment of annular remodeling post T-TEER. The reduction in TR grade and TV annulus dimensions begins immediately after TriClip implantation. Concurrently, the baseline TV geometry influences the procedural results.

SELECTION OF CITATIONS
SEARCH DETAIL