1.
Catheter Cardiovasc Interv ; 98(4): 723-732, 2021 10.
Article in English | MEDLINE | ID: mdl-34164905

ABSTRACT

OBJECTIVES: To investigate the long-term vasomotor response and inflammatory changes in Absorb bioresorbable vascular scaffold (BVS) and metallic drug-eluting stent (DES) implanted artery. BACKGROUND: Clinical evidence has demonstrated that compared to DES, BVS is associated with higher rates of target lesion failure. However, it is not known whether the higher event rates observed with BVS are related to endothelial dysfunction or inflammation associated with polymer degradation. METHODS: Ten Absorb BVS and six Xience V DES were randomly implanted in the main coronaries of six nonatherosclerotic swine. At 4-years, vasomotor response was evaluated in vivo by quantitative coronary angiography response to intracoronary infusion of Ach and ex vivo by the biomechanical response to prostaglandin F2-α (PGF2-α), substance P and bradykinin and gene expression analysis. RESULTS: Absorb BVS implanted arteries showed significantly restored vasoconstrictive responses after Ach compared to in-stent Xience V. The contractility of Absorb BVS treated segments induced by PGF2-α was significantly greater compared to Xience V treated segments and endothelial-dependent vasorelaxation was greater with Absorb BVS compared to Xience V. Gene expression analyses indicated the pro-inflammatory lymphotoxin-beta receptor (LTßR) signaling pathway was significantly upregulated in arteries treated with a metallic stent compared to Absorb BVS treated arterial segments. CONCLUSIONS: At 4 years, arteries treated with Absorb BVS compared with Xience V, demonstrate significantly greater restoration of vasomotor responses. Genetic analysis suggests mechanobiologic reparation of Absorb BVS treated arteries at 4 years as opposed to Xience V treated vessels.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Absorbable Implants , Animals , Everolimus , Gene Expression , Percutaneous Coronary Intervention/adverse effects , Prosthesis Design , Stents , Swine , Treatment Outcome
2.
Catheter Cardiovasc Interv ; 97(7): 1331-1340, 2021 06 01.
Article in English | MEDLINE | ID: mdl-32659048

ABSTRACT

BACKGROUND: Provisional side branch (SB) stenting is correlated with target vessel myocardial infarction (TVMI) in patients with coronary bifurcation lesions. However, the mechanisms underlying this association remain unknown. OBJECTIVES: To determine the correlation between SB lesion length with vulnerable plaques and TVMI using optical coherence tomography (OCT). BACKGROUND: The correlation between SB lesion length with vulnerable plaques and TVMI is unknown. METHODS: A total of 405 patients with 405 bifurcation lesions who underwent preprocedure OCT imaging of both the main vessel (MV) and the SB were enrolled. Patients were divided into long SB lesion (SB lesion length ≥10 mm) and short SB lesion (SB lesion length <10 mm) groups according to quantitative coronary analysis; they were also stratified by the presence of vulnerable plaques identified by OCT. The primary endpoint was the occurrence of TVMI after provisional stenting at 1-year follow-up. RESULTS: In total, 178 (43.9%) patients had long SB lesions. Vulnerable plaques were predominantly localized in the MV and were more frequently in the long SB lesion group (42.7%) than in the short SB lesion group (24.2%, p < .001). At 1-year follow-up after provisional stenting, there were 31 (7.7%) TVMIs, with 21 (11.8%) in the long SB lesion group and 10 (4.4%) in the short SB lesion group (p = .009). Multivariate regression analysis showed that long SB lesion length (p = .011), absence of vulnerable plaques in the polygon of confluence (p = .001), and true coronary bifurcation lesions (p = .004) were the three independent factors of TVMI. CONCLUSIONS: The presence of long SB lesion with MV vulnerable plaques predicts the increased risk of TVMI after provisional stenting in patients with true coronary bifurcation lesions. Further studies are warranted to identify the best stenting techniques for coronary bifurcation lesions with long SB lesions.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Myocardial Infarction , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Humans , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/etiology , Risk Factors , Stents , Tomography, Optical Coherence , Treatment Outcome
3.
Catheter Cardiovasc Interv ; 98(3): 470-480, 2021 09.
Article in English | MEDLINE | ID: mdl-32890452

ABSTRACT

OBJECTIVE: To examine rates and predictors repeat revascularization strategies (percutaneous coronary intervention [PCI] and coronary artery bypass grafting [CABG]) in patients with prior CABG. METHODS: Using the National Inpatient Sample, patients with a history of CABG hospitalized for revascularization by PCI or CABG from January 2004 to September 2015 were included. Regression analyses were performed to examine predictors of receipt of either revascularization strategy as well as in-hospital outcomes. RESULTS: The rate of redo CABG doubled between 2004 (5.3%) and 2015 (10.3%). Patients who underwent redo CABG were more comorbid and experienced significantly worse major adverse cardiovascular and cerebrovascular events (odds ratio [OR]: 5.36 95% CI 5.11-5.61), mortality (OR 2.84 95% CI 2.60,-3.11), bleeding (OR 5.97 95% CI 5.44-6.55) and stroke (OR 2.15 95% CI 1.92-2.41), but there was no difference in cardiac complications between groups. Thoracic complications were high in patients undergoing redo CABG (8%), especially in females. Factors favoring receipt of redo CABG compared to PCI included male sex, age < 80 years, and absence of diabetes and renal failure. CONCLUSION: Reoperation in patients with prior CABG has doubled in the United States over a 12-year period. Patients undergoing redo CABG are more complex and associated with worse clinical outcomes than those receiving PCI.


Subject(s)
Coronary Artery Disease , Diabetes Mellitus , Percutaneous Coronary Intervention , Stroke , Aged , Coronary Artery Bypass/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Female , Humans , Male , Percutaneous Coronary Intervention/adverse effects , Risk Factors , Stroke/etiology , Treatment Outcome , United States/epidemiology
4.
Cardiovasc Drugs Ther ; 35(2): 331-341, 2021 04.
Article in English | MEDLINE | ID: mdl-33085027

ABSTRACT

PURPOSE: This study was to analyze the incidence of definite stent thrombosis (ST) after the implantation of drug-eluting stents (DESs) and cutoff value of overlapping length for predicting definite ST. An overlapping stent is associated with a high rate of clinical events after DES implantation compared with a non-overlapping stent. However, the rates of definite ST and clinical outcomes from a large patient population remain underreported. METHODS: A total of 15,561 patients with 24,183 lesions who underwent DES implantation from January 2005 to February 2017 were retrospectively included in 5 tertiary hospitals in China. The main endpoint was the incidence of definite ST after procedures. RESULTS: With a median of 1932 (IQR = 1194-2929) days, clinical follow-up was available in 7484 patients in the overlap group and in 8077 patients in the non-overlap group. The rates of definite ST were 3.1% in the overlap group and 1.2% in the non-overlap group (HR: 2.67 (95% CI: 2.11-3.38), p < 0.001). Of the 24,183 treated lesions, the incidences of definite ST were 2.4% in the overlap group and 0.9% in the non-overlap group (HR: 2.96 (95% CI: 2.38-3.69), p < 0.001). Stent overlap was associated with a higher rate of target lesion revascularization (TLR) (9.4%) compared with stent non-overlap (6.4%, p < 0.001). The length of overlapping stent ≥ 2.93 mm strongly correlated with definite ST. CONCLUSION: The present study shows that overlapping DES increases definite ST and revascularization in patients during long-term follow-up. In addition, the longer overlapping zone was associated with worse clinical outcomes.


Subject(s)
Coronary Thrombosis/epidemiology , Drug-Eluting Stents/statistics & numerical data , Myocardial Revascularization/statistics & numerical data , Percutaneous Coronary Intervention/methods , Age Factors , Aged , Cardiovascular Agents/therapeutic use , China/epidemiology , Comorbidity , Dual Anti-Platelet Therapy/methods , Female , Humans , Hydroxymethylglutaryl-CoA Reductase Inhibitors/therapeutic use , Incidence , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Risk Factors , Sex Factors
5.
Catheter Cardiovasc Interv ; 92(4): 651-652, 2018 10 01.
Article in English | MEDLINE | ID: mdl-30341829

ABSTRACT

What the article teaches The article highlights the competency of high volume operators across institutions that despite moving to lower volume centers retain their good clinical outcomes. How it will impact practice Although current U.S. based guidelines suggest a volume of at least 50 PCIs annually for operators to retain clinical competency this estimate may be a poor index to guarantee optimal clinical outcomes. What new research/study would help answer the question New studies using a comprehensive definition to define an experienced operator from the Asia-Pacific-a geographic area that has pioneered in complex coronary interventions-need to elute on the threshold of adequate clinical competency stratified according to clinical complexity.


Subject(s)
Hospitals, High-Volume , Percutaneous Coronary Intervention , Asia , Clinical Competence
6.
BMC Cardiovasc Disord ; 15: 153, 2015 Nov 17.
Article in English | MEDLINE | ID: mdl-26577590

ABSTRACT

BACKGROUND: Intravascular ultrasound (IVUS) can be a useful tool during drug-eluting stents (DES) implantation as it allows accurate assessment of lesion severity and optimal treatment planning. However, numerous reports have shown that IVUS guided percutaneous coronary intervention is not associated with improved clinical outcomes, especially in non-complex patients and lesions. METHODS: We searched the literature in Medline, the Cochrane Library, and other internet sources to identify studies that compare clinical outcomes between IVUS-guided and angiography-guided DES implantation. Random-effects model was used to assess treatment effect. RESULTS: Twenty eligible studies with a total of 29,068 patients were included in this meta-analysis. The use of IVUS was associated with significant reductions in major adverse cardiovascular events (MACE, odds ratios [OR] 0.77, 95 % confidence intervals [CI] 0.71-0.83, P < 0.001), death (OR 0.62, 95 % CI 0.54-0.71, p < 0.001), and stent thrombosis (OR 0.59, 95 % CI: 0.47-0.73, P < 0.001). The benefit was also seen in the repeated analysis of matched and randomized studies. In stratified analysis, IVUS guidance appeared to be beneficial not only in patients with complex lesions or acute coronary syndromes (ACS) but also patients with mixed lesions or presentations (MACE: OR 0.69, 95 % CI: 0.60-0.79, p < 0.001, OR 0.81, 95 % CI 0.74-0.90, p < 0.001, respectively). By employing meta-regression analysis, the benefit of IVUS is significantly pronounced in patients with complex lesions or ACS with respect to death (p = 0.048). CONCLUSIONS: IVUS guidance was associated with improved clinical outcomes, especially in patients with complex lesions admitted with ACS. Large, randomized clinical trials are warranted to identify populations and lesion characteristics where IVUS guidance would be associated with better outcomes.


Subject(s)
Coronary Angiography , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Drug-Eluting Stents , Percutaneous Coronary Intervention/instrumentation , Ultrasonography, Interventional , Aged , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Female , Humans , Male , Middle Aged , Odds Ratio , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Predictive Value of Tests , Propensity Score , Risk Assessment , Risk Factors , Severity of Illness Index , Treatment Outcome
8.
Cardiovasc Ultrasound ; 11: 25, 2013 Jul 20.
Article in English | MEDLINE | ID: mdl-23870248

ABSTRACT

PURPOSE: To evaluate the atherosclerotic evolution in coronary bifurcations located proximally and distally to a bioresorbable scaffold. METHODS: Thirty bifurcations located >5 mm beyond the scaffolded segment, being investigated with serial intravascular ultrasound virtual histology (IVUS-VH) examinations, at baseline and 2-years, in patients enrolled in the ABSORB cohort B1 study were included in this analysis. In each bifurcation, the frames portraying the proximal rim, in-bifurcation, and distal rim of the ostium of the side branch were analyzed. The geometric parameters and plaque types were evaluated at baseline and 2-years follow-up. RESULTS: There were no significant differences in the geometrical parameters such as lumen, vessel and plaque areas as well as in the composition of the atheroma between baseline and 2-years follow-up.When we separately examined the bifurcations located proximally and distally to the scaffolded segment, no changes were found at the distal bifurcations, while at the proximal bifurcations there was a statistical significant decrease in the plaque burden (36.67 ± 13.33% at baseline vs. 35.06 ± 13.20% at 2 years follow-up, p = 0.04).Ten necrotic core rich plaques were found at baseline, of which 2 regressed to either fibrotic plaque or to intimal thickening at 2 years follow-up. The other 8 did not change. Disease progression was noted in 3 plaques (1 adaptive intimal thickening, 1 fibrotic and 1 fibrocalcific plaque) that evolved to necrotic rich plaques. CONCLUSIONS: Plaque regression was noted at the bifurcations located proximally to the bioresorbable scaffold but not at these located distally. Additional studies are required to confirm this finding and examine further the effect of drug elution on atherosclerotic evolution.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Drug-Eluting Stents , Echocardiography/methods , Sirolimus/analogs & derivatives , Ultrasonography, Interventional/methods , Aged , Coronary Stenosis , Everolimus , Female , Humans , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Immunosuppressive Agents/administration & dosage , Male , Reproducibility of Results , Sensitivity and Specificity , Sirolimus/administration & dosage , Subtraction Technique , Treatment Outcome , User-Computer Interface
9.
Catheter Cardiovasc Interv ; 79(6): 890-902, 2012 May 01.
Article in English | MEDLINE | ID: mdl-21523891

ABSTRACT

OBJECTIVE: To report the agreement between gray-scale intravascular ultrasound (GS-IVUS) and optical coherence tomography (OCT) in assessing the bioresorbable vascular scaffolds (BVS) structures and their respective reproducibility. BACKGROUND: BVS are composed of an erodible polymer. Ultrasound and light signals backscattered from polymeric material differs from metallic stents using GS-IVUS and OCT. METHODS: Forty-five patients included in the ABSORB trial were treated with a 3.0 × 18 mm BVS and imaged with GS-IVUS 20 MHz and OCT post-implantation. Qualitative (ISA, side-branch struts, protrusion, and dissections) and quantitative (number of struts, lumen, and scaffold area) measurements were assessed by two investigators. The agreement and the inter- and intraobserver reproducibility were investigated using the kappa (κ) and the interclass correlation coefficient (ICC). RESULTS: GS-IVUS and OCT agreement was predominantly poor at a lesion, frame, and strut level analysis (κ and ICC <0.4) for qualitative measurements. GS-IVUS demonstrated a reduced ability to detect cross-sections with ISA (4.5% vs. 20.6%), side-branch (SB) struts (6.3% vs. 7.8%), protrusions (3.2% vs. 9.6%), and dissections (0.2% vs. 9.0%) compared with OCT. GS-IVUS reproducibility was poor-moderate (κ and ICC <0.6) except for ISA and SB-struts (κ and ICC between 0.2 and 0.75). OCT showed an excellent reproducibility (κ and ICC > 0.75) except for the assessment of tissue protrusion (κ and ICC between 0.47 and 0.94). GS-IVUS reproducibility was poor-moderate (ICC ≤ 0.5) in assessing the number of struts but excellent with OCT (ICC > 0.85). The reproducibility to assess lumen and scaffold areas was excellent using both techniques (ICC > 0.85). CONCLUSIONS: GS-IVUS has a poor capacity to detect qualitative findings post-BVS implantation and its reproducibility is low compared with OCT. The use of GS-IVUS should be limited when assessing lumen and scaffold areas.


Subject(s)
Absorbable Implants , Angioplasty, Balloon, Coronary/instrumentation , Cardiovascular Agents/administration & dosage , Myocardial Ischemia/therapy , Sirolimus/analogs & derivatives , Tissue Scaffolds , Tomography, Optical Coherence , Ultrasonography, Interventional , Aged , Angioplasty, Balloon, Coronary/adverse effects , Drug Carriers , Everolimus , Female , Humans , Male , Middle Aged , Myocardial Ischemia/diagnostic imaging , Myocardial Ischemia/pathology , Observer Variation , Predictive Value of Tests , Prosthesis Design , Reproducibility of Results , Sirolimus/administration & dosage , Time Factors , Treatment Outcome
10.
Catheter Cardiovasc Interv ; 79(6): 880-8, 2012 May 01.
Article in English | MEDLINE | ID: mdl-22514149

ABSTRACT

OBJECTIVES: Due to the limited distensibility of the everolimus-eluting bioresorbable vascular scaffold (ABSORB) compared to metallic platform stents, quantitative coronary arteriography (QCA) is a mandatory requirement for ABSORB deployment in the on-going ABSORB EXTEND Single-Arm Study. Visual assessment of vessel size in the ABSORB Cohort B study often lead to under and over-sizing of the 3 mm ABSORB in coronary vessels (recommended range of the vessel diameter ≥ 2.5 mm and ≤ 3.3 mm), with an increased risk of spontaneous incomplete scaffold apposition post ABSORB deployment. We report whether mandatory QCA assessment of vessel size pre-implantation, utilizing the maximal luminal diameter (Dmax) and established interpolated reference vessel diameter (RVD) measurements, has improved device/vessel sizing. METHODS: Pre-implantation post-hoc QCA analyses of all 101 patients from ABSORB Cohort B (102 lesions) and first consecutive 101 patients (108 lesions) from ABSORB EXTEND were undertaken by an independent core-laboratory; all patients had a 3 mm ABSORB implanted. Comparative analyses were performed. RESULTS: Within ABSORB Cohort B, a greater number of over-sized vessels (> 3.3 mm) were identified utilizing the Dmax compared to the interpolated RVD (17 vessels, 16.7% vs. 3 vessels, 2.9%; P = 0.002). Comparative analyses demonstrated a greater number of appropriate vessel-size selection (75 vessels, 69.4% vs. 48 vessels, 47.1%; P = 0.001), a trend towards a reduction in implantation in small (< 2.5 mm) vessels (29 vessels, 26.9% vs. 40 vessels, 39.2%; P = 0.057) and a significant decrease in the implantation in large (> 3.3 mm) vessels (4 vessels, 3.7% vs. 17 vessels, 16.7%; P = 0.002) in ABSORB EXTEND. Bland-Altman plots suggested a good agreement between operator and core-laboratory calculated Dmax measurements. CONCLUSIONS: The introduction of mandatory Dmax measurements of vessel size prior to ABSORB implantation significantly reduced the under-sizing of the 3.0 mm scaffold in large vessels validating the use of this technique in vessel sizing prior to ABSORB implantation.


Subject(s)
Absorbable Implants , Angioplasty, Balloon, Coronary/instrumentation , Cardiovascular Agents/administration & dosage , Coronary Angiography , Myocardial Ischemia/therapy , Sirolimus/analogs & derivatives , Tissue Scaffolds , Angioplasty, Balloon, Coronary/adverse effects , Chi-Square Distribution , Drug Carriers , Everolimus , Humans , Myocardial Ischemia/diagnostic imaging , Predictive Value of Tests , Prospective Studies , Prosthesis Design , Sirolimus/administration & dosage , Time Factors , Treatment Outcome , Ultrasonography, Interventional
11.
Circ J ; 76(7): 1616-23, 2012.
Article in English | MEDLINE | ID: mdl-22531596

ABSTRACT

BACKGROUND: Implantation of a metallic prosthesis creates local stiffness with a subsequent mismatch in the compliance of the vessel wall, disturbances in flow and heterogeneous distribution of wall shear stress. Polymeric bioresorbable ABSORB scaffolds have less stiffness than metallic platform stents. We sought to analyze the mismatch in vascular compliance after ABSORB implantation and its long-term resolution with bioresorption. METHODS AND RESULTS: A total of 83 patients from the ABSORB trials underwent palpography investigations (30 and 53 patients from ABSORB Cohorts A and B, respectively) to measure the compliance of the scaffolded and adjacent segments at various time points (from pre-implantation up to 24 months). The mean of the maximum strain values was calculated per segment by utilizing the Rotterdam Classification (ROC) score and expressed as ROC/mm. Scaffold implantation lead to a significant decrease in vascular compliance (median [IQR]) at the scaffolded segment (from 0.37 [0.24-0.45] to 0.14 [0.09-0.23], P<0.001) with mismatch in compliance in a paired analysis between the scaffolded and adjacent segments (proximal: 0.23 [0.12-0.34], scaffold: 0.12 [0.07-0.19], distal: 0.15 [0.05-0.26], P=0.042). This reported compliance mismatch disappears at short- and mid-term follow-up. CONCLUSIONS: The ABSORB scaffold decreases vascular compliance at the site of scaffold implantation. A compliance mismatch is evident immediately post-implantation and in contrast to metallic stents disappears in the mid-term, likely leading to a normalization of the rheological behavior of the scaffolded segment.


Subject(s)
Absorbable Implants , Angioplasty, Balloon, Coronary/instrumentation , Coronary Artery Disease/therapy , Coronary Circulation , Coronary Vessels/physiopathology , Drug-Eluting Stents , Hemodynamics , Polyesters/chemistry , Aged , Angioplasty, Balloon, Coronary/adverse effects , Biomechanical Phenomena , Cardiovascular Agents/administration & dosage , Compliance , Coronary Angiography , Coronary Artery Disease/diagnosis , Coronary Artery Disease/physiopathology , Coronary Vessels/diagnostic imaging , Everolimus , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prosthesis Design , Sirolimus/administration & dosage , Sirolimus/analogs & derivatives , Time Factors , Treatment Outcome , Ultrasonography, Interventional
12.
Eur Heart J ; 32(3): 294-304, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21123276

ABSTRACT

AIMS: The first generation of the everolimus-eluting bioresorbable vascular scaffold (BVS 1.0) showed an angiographic late loss higher than the metallic everolimus-eluting stent Xience V due to scaffold shrinkage. The new generation (BVS 1.1) presents a different design and manufacturing process than the BVS 1.0. This study sought to evaluate the differences in late shrinkage, neointimal response, and bioresorption process between these two scaffold generations using optical coherence tomography (OCT). METHODS AND RESULTS: A total of 12 lesions treated with the BVS 1.0 and 12 selected lesions treated with the revised BVS 1.1 were imaged at baseline and 6-month follow-up with OCT. Late shrinkage and neointimal area (NIA) were derived from OCT area measurements. Neointimal thickness was measured in each strut. Strut appearance has been classified as previously described. Baseline clinical, angiographic, and OCT characteristics were mainly similar in the two groups. At 6 months, absolute and relative shrinkages were significantly larger for the BVS 1.0 than for the BVS 1.1 (0.98 vs. 0.07 mm² and 13.0 vs. 1.0%, respectively; P = 0.01). Neointimal area was significantly higher in the BVS 1.0 than in the BVS 1.1 (in-scaffold area obstruction of 23.6 vs. 12.3%; P < 0.01). Neointimal thickness was also larger in the BVS 1.0 than in the BVS 1.1 (166.0 vs. 76.4 µm; P < 0.01). Consequently, OCT, intravascular ultrasound, and angiographic luminal losses were higher with the BVS 1.0 than with the BVS 1.1. At 6 months, strut appearance was preserved in only 2.9% of the BVS 1.0 struts, but remained unchanged with the BVS 1.1 indicating different state of strut microstucture and/or their reflectivity. CONCLUSION: The BVS 1.1 has less late shrinkage and less neointimal growth at 6-month follow-up compared with the BVS 1.0. A difference in polymer degradation leading to changes in microstructure and reflectivity is the most plausible explanation for this finding.


Subject(s)
Drug-Eluting Stents/standards , Immunosuppressive Agents/administration & dosage , Myocardial Ischemia/diagnostic imaging , Sirolimus/analogs & derivatives , Tomography, Optical Coherence/methods , Aged , Biocompatible Materials/standards , Blood Vessel Prosthesis/standards , Coronary Angiography/methods , Everolimus , Female , Humans , Male , Middle Aged , Myocardial Ischemia/therapy , Prosthesis Design , Prosthesis Failure , Sirolimus/administration & dosage , Tissue Scaffolds , Ultrasonography, Interventional
13.
Catheter Cardiovasc Interv ; 77(3): 435-8, 2011 Feb 15.
Article in English | MEDLINE | ID: mdl-21328684

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has nowadays replaced open heart surgery as an alternative therapeutic tool in selected patients. Thirty-five percent of patients with severe degenerative aortic valve stenosis (AS) remain untreated because of the existing comorbidities that increase their perioperative risk. TAVI is a relatively new technique that has "come to stay" in the everyday clinical practice considering, that is the only alternative to surgery and appears to have excellent long term results. Herein, we describe a vascular complication immediately after the implantation of the Edwards SAPIEN (Edwards Lifesciences, Irvine, CA) prosthesis, followed by ad hoc percutaneous coronary intervention.


Subject(s)
Aortic Valve Stenosis/therapy , Cardiac Catheterization/adverse effects , Coronary Occlusion/etiology , Heart Valve Prosthesis Implantation/adverse effects , Acute Disease , Angioplasty, Balloon, Coronary/instrumentation , Cardiac Catheterization/instrumentation , Coronary Angiography , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/therapy , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/instrumentation , Humans , Middle Aged , Prosthesis Design , Stents , Treatment Outcome
14.
Coron Artery Dis ; 32(2): 105-111, 2021 Mar 01.
Article in English | MEDLINE | ID: mdl-33060524

ABSTRACT

OBJECTIVES: The purpose of this study was to evaluate the association of diabetes mellitus (DM) with neointimal formation after implantation of second-generation drug-eluting stent (DES) visualized by optical coherence tomography (OCT). METHODS: Patients with single de novo coronary artery disease treated with second-generation DES between June 2014 and June 2017 in our department underwent OCT examination at 1-year follow-up and were enrolled in this retrospective study. The primary end point was in-stent mean neointimal thickness (MNT), and secondary end points included uncovered stent strut, minimal lumen area (MLA), neointimal burden, neointimal hyperplasia (NIH) patterns and stent thrombosis (ST) after 1 year of OCT follow-up. RESULTS: A total of 68 patents with DM (DM group) and 216 patients without DM (non-DM group) were enrolled. At 1-year follow-up, the DM group compared with the non-DM group, showed: MNT [160 (85-245) µm vs. 120 (60-220) µm, P = 0.038] and neointimal burden [21.4 (8.3-30.1)% vs. 14.0 (5.7-26.1)%, P = 0.023] to be significantly increased. Concurrently, MLA [4.60 (3.53-6.06) mm vs. 5.76 (4.28-7.20) mm2, P = 0. 0.002] was significantly reduced. Interestingly, the degree of uncovered struts (7.3 ± 7.1% vs. 7.7 ± 6.7%, P = 0.704), NIH patterns (P = 0.984), and ST (7.9% vs. 7.4%, P = 0.88) were comparable between the two groups. After propensity score matching, the MNT [160 (90-240) µm vs. 110 (60-220) µm, P = 0.048] and neointimal burden [21.4 (8.3-30.1)% vs. 15.4 (5.6-26.3)%, P = 0.044] remained significantly different in the DM compared to the non-DM group. CONCLUSION: DM leads to significant increase in MNT and neointimal burden even with second-generation DES, nevertheless stent strut coverage, ST and NIH characteristics remained comparable among the cohorts at 1-year.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/drug therapy , Diabetes Mellitus , Drug-Eluting Stents , Neointima/pathology , Tomography, Optical Coherence , Aged , Female , Humans , Male , Middle Aged , Propensity Score , Retrospective Studies
15.
Cardiol J ; 28(2): 223-234, 2021.
Article in English | MEDLINE | ID: mdl-31702046

ABSTRACT

BACKGROUND: Current guidelines recommend newer generation drug-eluting stents (DES) over bare-metal stents (BMS) in patients with ischemic heart disease. However, there is no age-specific recommendation in elderly patients. METHODS: Meta-analysis was performed of 6 randomized studies enrolling 5,042 elderly patients who underwent percutaneous coronary intervention (PCI) with stent implantation (DES, n = 2,579; BMS, n = 2,463). RESULTS: Combined data indicated a significant reduction in major adverse cardiovascular events (MACEs) with use of DES (odds ratio [OR] 0.56, 95% confidence interval [CI] 0.44-0.71, p < 0.001). Moreover, use of DES was associated with a significantly lower incidence of myocardial infarction (OR 0.54, 95% CI 0.36-0.81, p = 0.003) and repeat revascularization (OR 0.44, 95% CI 0.31-0.62, p < 0.001), was compared to that with the use of BMS. Stent thrombosis and bleeding complication rates were not significantly different between groups. In a subgroup meta-analysis, short duration (1 or 6 months) dual antiplatelet therapy (DAPT) was associated with a significantly lower MACE rate (OR 0.49, 95% CI 0.34-0.80; p = 0.003) in elderly patients who underwent PCI with everolimuseluting stent implantation, compared with that using long duration DAPT. CONCLUSIONS: This meta-analysis provides clinically relevant evidence that DES rather than BMS should be selected for elderly patients.


Subject(s)
Drug-Eluting Stents , Percutaneous Coronary Intervention , Aged , Humans , Male , Prosthesis Design , Randomized Controlled Trials as Topic , Stents , Treatment Outcome
16.
Cardiovasc Revasc Med ; 21(12): 1596-1605, 2020 12.
Article in English | MEDLINE | ID: mdl-32546382

ABSTRACT

Coronary artery bypass surgery has been the accepted treatment for left main coronary artery disease for over 50 years. Balloon angioplasty was later used then abandoned because of deaths likely due to restenosis or thrombotic occlusion. However, rapid innovations in drug-eluting stent designs leading to more biocompatible thin strut platforms with optimal drug elution profiles and further advances in modern pharmacotherapy involving potent P2Y12 inhibitors combined with utilization of intracoronary imaging and physiologic assessment for procedural planning and optimization have transformed percutaneous interventions into successful alternatives to coronary artery bypass graft surgery (CABG) in selected LM anatomic territories. Herein, we provide an evidence-based practical guide on how to approach and perform LM percutaneous interventions (PCI).


Subject(s)
Coronary Artery Disease , Percutaneous Coronary Intervention , Coronary Artery Bypass , Drug-Eluting Stents , Humans , Treatment Outcome
17.
PLoS One ; 15(7): e0235673, 2020.
Article in English | MEDLINE | ID: mdl-32645029

ABSTRACT

BACKGROUND AND OBJECTIVES: This study sought to compare clinical outcomes between bioresorbable scaffolds (BRS) and durable polymer everolimus-eluting metallic stents (DP-EES) in patients with acute myocardial infarction (AMI) undergoing successful percutaneous coronary intervention (PCI). METHODS: From March 2016 to October 2017, 952 patients with AMI without cardiogenic shock undergoing successful PCI with BRS (n = 136) or DP-EES (n = 816) were enrolled from a multicenter, observational Korea Acute Myocardial Infarction Registry. RESULTS: In the crude population, there was no significant difference in the 1-year rate of device-oriented composite endpoint (DOCE) and device thrombosis between the BRS and DP-EES groups (2.2% vs. 4.8%, hazard ratio [HR] 0.43, 95% confidence interval [CI] 0.13-1.41, p = 0.163; 0.7% vs. 0.5%, HR 1.49, 95% CI 0.16-13.4, p = 0.719, respectively). BRS implantation was opted in younger patients (53.7 vs. 62.6 years, p < 0.001) with low-risk profiles, and intravascular image-guided PCI was more preferred in the BRS group (60.3% vs. 27.2%, p < 0.001). CONCLUSIONS: At 1-year follow-up, no differences in the rate of DOCE and device thrombosis were observed between patients with AMI treated with BRS and those treated with DP-EES. Our data suggest that imaging-guided BRS implantation in young patients with low risk profiles could be a reasonable strategy in the setting of AMI.


Subject(s)
Absorbable Implants/adverse effects , Drug-Eluting Stents/adverse effects , Myocardial Infarction/surgery , Percutaneous Coronary Intervention/adverse effects , Acute Disease/therapy , Adult , Aged , Cardiovascular Agents/therapeutic use , Endpoint Determination , Everolimus/therapeutic use , Female , Humans , Male , Middle Aged , Myocardial Infarction/therapy , Proportional Hazards Models , Republic of Korea , Thrombosis/etiology , Tissue Scaffolds/adverse effects , Treatment Outcome
18.
EuroIntervention ; 16(12): e989-e996, 2020 12 18.
Article in English | MEDLINE | ID: mdl-32091401

ABSTRACT

AIMS: The Absorb bioresorbable vascular scaffold (BVS) has high rates of target lesion failure (TLF) at three years. Low wall shear stress (WSS) promotes several mechanisms related to device TLF. We investigated the impact of BVS compared to XIENCE V (XV) on coronary WSS after device deployment. METHODS AND RESULTS: In the prospective, randomised, controlled ABSORB III Imaging study (BVS [n=77] or XV [n=36]), computational fluid dynamics were performed on fused angiographic and intravascular ultrasound (IVUS) images of post-implanted vessels. Low WSS was defined as <1 Pa. There were no differences in demographics, clinical risks, angiographic reference vessel diameter or IVUS minimal lumen diameter between BVS and XV patients. A greater proportion of vessels treated with BVS compared to XV demonstrated low WSS across the whole device (BVS: 17/77 [22%] vs XV: 2/36 [6%], p<0.029). Compared to XV, BVS demonstrated lower median circumferential WSS (1.73 vs 2.21 Pa; p=0.036), outer curvature WSS (p=0.026), and inner curvature WSS (p=0.038). Similarly, BVS had lower proximal third WSS (p=0.024), middle third WSS (p=0.047) and distal third WSS (p=0.028) when compared to XV. In a univariable logistic regression analysis, patients who received BVS were 4.8 times more likely to demonstrate low WSS across the scaffold/stent when compared to XV patients. Importantly, in a multivariable linear regression model, hypertension (beta: 0.186, p=0.023), lower contrast frame count velocity (beta: -0.411, p<0.001), lower post-stent residual plaque burden (beta: -0.338, p<0.001), lower % underexpanded frames (beta: -0.170, p=0.033) and BVS deployment (beta: 0.251, p=0.002) remained independently associated with a greater percentage of stented coronary vessel areas exposed to low WSS. CONCLUSIONS: In this randomised controlled study, the Absorb BVS was 4.8 times more likely than the XV metallic stent to demonstrate low WSS. BVS implantation, lower blood velocity and lower residual post-stent plaque burden were independently associated with greater area of low WSS.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Absorbable Implants , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Everolimus/therapeutic use , Humans , Prospective Studies , Prosthesis Design , Stents , Treatment Outcome
20.
EuroIntervention ; 13(16): 1904-1913, 2018 03 20.
Article in English | MEDLINE | ID: mdl-29278353

ABSTRACT

AIMS: The aim of this study was to investigate the long-term safety and efficacy of biodegradable scaffolds and metallic stents. METHODS AND RESULTS: We analysed a total of 91 randomised controlled trials with a mean follow-up of 3.7 years in 105,842 patients which compared two or more coronary metallic stents or biodegradable scaffolds and reported the long-term clinical outcomes (≥2 years). Network meta-analysis showed that patients treated with the Absorb bioresorbable vascular scaffold (BVS) had a significantly higher risk of definite or probable scaffold thrombosis (ScT) compared to those treated with metallic DES. The risk of very late ScT was highest with the Absorb BVS among comparators. Pairwise conventional meta-analysis demonstrated that the elevated risk of ScT with Absorb BVS compared to cobalt-chromium everolimus-eluting stents was consistent across the time points of ≤30 days (early), 31 days - 1 year (late) and >1 year (very late) ScT. In addition, target lesion failure rates were significantly higher in the Absorb BVS cohort, driven by both increased risk of target vessel myocardial infarction and ischaemia-driven target lesion revascularisation. CONCLUSIONS: Absorb BVS implantation was associated with increased risk of long-term and very late ScT compared to current-generation metallic DES. The risk of ScT occurred with a rising trend beyond one year.


Subject(s)
Absorbable Implants , Coronary Artery Disease/surgery , Metals , Percutaneous Coronary Intervention/instrumentation , Stents , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Thrombosis/etiology , Humans , Patient Safety , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Randomized Controlled Trials as Topic , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome