Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Int Ophthalmol ; 43(12): 4921-4931, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37837486

ABSTRACT

OBJECTIVES: To investigate the current surgery strategies for bilateral proliferative diabetic retinopathy (PDR), as well as the surgical outcomes of patients with bilateral PDR who underwent pars plana vitrectomy (PPV). MATERIALS: Patients undergoing bilateral vitrectomy for PDR from January 2019 to December 2020 at The Eye Hospital of Wenzhou Medical University were enrolled. Clinical data were collected from the electronic medical records. Factors associated with the time interval between the surgeries on two eyes and postoperative visual outcomes were analyzed. RESULTS: In total, 152 patients with bilateral PDR who underwent bilateral PPV were included in this analysis. Mean age was 53.7 ± 11.4 years. Compared with second-surgery eyes, 60.5% of first-surgery eyes had worse preoperative best-corrected visual acuity (BCVA). The overall PPV time (median, quartile range) between first and second surgeries eye was 1.40 (0.70, 3.15) months. Multivariate analysis showed that the preoperative BCVA of the second-surgery eye had a significant effect on the inter-surgery time interval (P = 0.048). First-surgery eyes had greater vision improvement than second-surgery eyes (Difference of the logarithm of the minimum angle of resolution [LogMAR] BCVA: - 1.00 [- 1.48, - 0.12] versus 0.00 [- 1.30, 0.00], respectively, P < 0.001), especially when eyes with poorer BCVA underwent PPV first (- 1.15 [- 1.87, - 0.54] versus 0.00 [- 0.70, 0.00], respectively, P < 0.001). CONCLUSIONS: Visual acuity is a significant factor that influences surgical strategies, including both surgery order and interval, for patients with bilateral PDR. The eyes operated upon first show more vision improvement due to prompt surgery.


Subject(s)
Diabetes Mellitus , Diabetic Retinopathy , Vitreoretinopathy, Proliferative , Humans , Adult , Middle Aged , Aged , Diabetic Retinopathy/diagnosis , Diabetic Retinopathy/surgery , Diabetic Retinopathy/complications , Vitrectomy , Eye , Visual Acuity , Retrospective Studies
2.
Int Ophthalmol ; 41(12): 3903-3910, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34291401

ABSTRACT

PURPOSE: To compare safety and effectiveness among methods to remove sticky silicone oil bubbles adhered to the retinal surface. METHODS: This retrospective nonrandomised case series included 14 eyes of 14 patients who had sticky silicone oil residue during silicone oil removal surgery. For small sticky silicone oil bubbles (< 2-disc diameter), aspiration was performed with a 23-gauge vitreous cutter. Residual tiny oil bubbles were then removed with a silicone-tipped flute needle or internal limiting membrane (ILM) peeling. For large sticky silicone oil bubbles (≥ 2-disc diameter) that could not be removed with a 23-gauge vitreous cutter, we devised a more efficient active removal method involving a modified 22-gauge venous indwelling cannula device. RESULTS: The mean preoperative best-corrected visual acuity (BCVA; logarithm of the minimum angle of resolution [logMAR]) significantly improved from 1.28 ± 0.63 logMAR to 0.77 ± 0.58 logMAR (p = 0.014). The postoperative BCVA and improvement in BCVA were significantly better in the ILM peeling group than in the non-ILM peeling group (p = 0.004 and p = 0.045, respectively). Postoperative complications included residual sticky silicone oil bubbles in seven eyes without ILM peeling (50.0%), retinal neuroepithelial layer damage in two eyes (14.3%), and temporary hypotony in five eyes (35.7%). CONCLUSION: Various methods can safely and efficiently remove sticky silicone oil bubbles adhered to the retinal surface. A 22-gauge venous indwelling cannula enabled simple and safe removal of large sticky silicone oil bubbles, while small residual sticky silicone oil bubbles could be completely removed by ILM peeling.


Subject(s)
Retinal Detachment , Retinal Perforations , Basement Membrane , Endotamponade , Humans , Retinal Detachment/surgery , Retinal Perforations/surgery , Retrospective Studies , Silicone Oils , Tomography, Optical Coherence , Visual Acuity , Vitrectomy
3.
Acta Ophthalmol ; 2023 Oct 11.
Article in English | MEDLINE | ID: mdl-37818952

ABSTRACT

PURPOSE: To identify prognostic factors for complete anatomical success (CAS) under different axial length (AL) conditions after vitrectomy plus internal limiting membrane (ILM) peeling for retinal detachment associated with macular hole (MHRD). METHODS: This retrospective study included 243 patients (251 eyes) with MHRD who underwent primary vitrectomy plus ILM peeling. Multivariate logistic regression explored prognostic factors for CAS in AL <30 mm and ≥ 30 mm groups. RESULTS: Overall, 113 eyes (45.0% of 251) exhibited complete CAS after initial surgery. Eyes with CAS had greater best-corrected visual acuity improvement than eyes without CAS (p < 0.001). CAS was more common in eyes with AL < 30 mm (50.3% of 155) than in eyes with AL ≥ 30 mm (36.5%, 35/96; p = 0.032). In the AL < 30 mm group, CAS was associated with ILM insertion (odds ratio [OR], 2.824, 95% confidence interval [CI], 1.189-6.710; p = 0.019), silicone oil (SO)/perfluoropropane (C3F8) tamponade (SO: OR, 0.408, 95% CI, 0.191-0.873; C3F8: OR, 2.448, 95% CI, 1.145-5.234; p = 0.021) and staphyloma (OR, 0.318, 95% CI, 0.143-0.707; p = 0.005). In the AL ≥30 mm group, CAS was associated with ILM insertion (OR, 11.621, 95% CI, 2.557-52.813; p = 0.001), SO /C3F8 tamponade (SO: OR, 5.305, 95% CI, 1.206-23.334; C3F8: OR, 0.188, 95% CI, 0.043-0.829; p = 0.027) and age (OR, 0.928, 95% CI, 0.876-0.983; p = 0.011). CONCLUSION: Vitrectomy plus ILM peeling can effectively treat MHRD but has limited efficacy in eyes with AL ≥ 30 mm. ILM insertion was associated with more frequent CAS at any AL. C3F8 tamponade yielded better outcomes with AL < 30 mm; SO tamponade yielded better outcomes with AL ≥ 30 mm.

4.
Int J Ophthalmol ; 16(2): 215-223, 2023.
Article in English | MEDLINE | ID: mdl-36816206

ABSTRACT

AIM: To identify the risk factors for postoperative proliferative vitreoretinopathy (PVR) in patients with primary rhegmatogenous retinal detachment (RRD) and develop a nomogram for predicting postoperative PVR-free probability. METHODS: A total of 741 patients (741 eyes) diagnosed with primary RRD who underwent first surgery in the same hospital were retrospectively reviewed and randomly assigned with 521 to the training set and 220 to the validation set. Univariate and multivariate logistic regression analyses were performed in the training cohort to determine risk factors to construct a nomogram for predicting the 3-, 4-, 5-, and 6-month postoperative PVR-free probabilities. Nomogram performance was estimated by the concordance index (C-index), calibration plot, and the area receiver operating characteristic (ROC) curve. RESULTS: A nomogram was constructed based on the preoperative PVR, silicone oil tamponade time (SOTT), photocoagulation energy (PE), retinal tear size (RTS), and hypertension. In the training set, the C-index of the nomogram was 0.896, 0.936, 0.961, and 0.972 at 3, 4, 5, and 6mo, respectively. The C-index values in the validation set were 0.860, 0.936, 0.951, and 0.965 at 3, 4, 5, and 6mo, respectively. Decision-curve analysis indicated that only the 4-, 5-, and 6-month nomograms had significant net benefits over a large threshold probabilities interval. CONCLUSION: Preoperative PVR, SOTT, PE, RTS, and hypertension are significant risk factors for postoperative PVR formation in patients with primary RRD. The proposed nomogram can effectively predict the 4-, 5-, and 6-month PVR-free probabilities after surgery and assist in making clinical decisions during follow-up.

5.
Acta Ophthalmol ; 100(4): e1024-e1030, 2022 Jun.
Article in English | MEDLINE | ID: mdl-34403213

ABSTRACT

PURPOSE: To report the clinical outcomes and evaluate the efficacy of a novel bubble ultra-wide field viewing system for vitreoretinal surgery. DESIGN: Prospective, noncomparative, interventional case series. PARTICIPANTS: One hundred and fifty-one eyes of 146 consecutive patients with proliferative diabetic retinopathy (PDR), vitreous haemorrhage originating from retinal vein occlusion (VH-RVO), epiretinal membrane (EM), macular hole (MH) or retinal detachment (RD) who underwent vitreoretinal surgery using the bubble ultra-wide field viewing system were included. METHODS: A standard phacoemulsification was performed on each patient. Core humour and mid-peripheral vitreous humour were removed using a planoconcave lens. A suitably sized bubble was infused to attach to the posterior capsule or the anterior chamber depending on the integrity of the posterior capsule. The planoconcave lens and the air bubble formed the wide-angle viewing system, through which peripheral vitrectomy was performed. MAIN OUTCOME MEASURES: Range of applications, field of view, model validation and complications were recorded. RESULTS: The new ultra-wide field viewing system was successfully applied in all eyes, including 34 with PDR, 28 VH-RVO, 28 EM, 25 MH and 36 RD. Peripheral vitrectomy, local or panretinal laser photocoagulation, and removal of the peripheral proliferative membrane were successfully performed while viewing through this system. Maximum peripheral retinal area observable during the procedure was positively correlated with pupil diameter. Model analysis results showed that when the pupil diameter was 6 mm, the maximum field of view was approximately 128.1- 148.0 degrees with this system. Of 142 eyes, the main intraoperative complication was iatrogenic retinal breaks (IRBs) in 8 eyes (5.3%) and posterior capsule injury by vitreous cutter during bubble removal in 6 eyes (4.2%). The postsurgery mean best-corrected visual acuity (BCVA) (0.48 ± 0.39 logMAR) was significantly improved compared with the preoperative mean BCVA (1.60 ± 1.08 logMAR, p < 0.001). No incidents of postoperative choroidal detachment, secondary glaucoma or endophthalmitis were recorded. CONCLUSIONS: For patients with lens excision or absence, vitreoretinal surgery can be successfully performed using the novel viewing system described here. The system is a safe, convenient and economical ultra-wide field viewing system with a wide range of applications.


Subject(s)
Diabetic Retinopathy , Epiretinal Membrane , Retinal Detachment , Vitreoretinal Surgery , Diabetic Retinopathy/complications , Epiretinal Membrane/complications , Epiretinal Membrane/diagnosis , Epiretinal Membrane/surgery , Humans , Postoperative Complications/surgery , Prospective Studies , Retinal Detachment/diagnosis , Retinal Detachment/etiology , Retinal Detachment/surgery , Retrospective Studies , Treatment Outcome , Visual Acuity , Vitrectomy/methods , Vitreoretinal Surgery/adverse effects
6.
Br J Ophthalmol ; 103(10): 1495-1502, 2019 10.
Article in English | MEDLINE | ID: mdl-30470714

ABSTRACT

PURPOSE: The aim of this study was to determine the effect of the inverted internal limiting membrane (ILM) flap technique on the macular hole (MH) closure and foveal microstructure recovery of patients with highly myopic MH. METHODS: Pars plana vitrectomy and gas tamponade with the inverted ILM flap technique (19 eyes) or with the ILM peeling technique (21 eyes) were performed in patients with highly myopic MH with or without retinal detachment. The rate of MH closure and retinal reattachment, the reconstructive anatomical change of the foveal microstructure and the best-corrected visual acuities (BCVA) of the two groups were compared. RESULTS: The anatomic closure rate was statistically significantly higher in the inverted group (100%) than in the peeling group (66.7%; p=0.009). All eyes with MH retinal detachment had successful retinal reattachment in these two groups. However, the rate of the external limiting membrane (ELM) and ellipsoid zone (EZ) (p=0.020), as well as gliosis (p=0.049) in macular area, detected by OCT, was significantly greater in the inverted group than in the peeling group. The postoperative BCVA was significantly better in the eyes with ELM, EZ (p=0.031) and gliosis (p=0.008), but without hyperreflective foci (p=0.001). CONCLUSIONS: These findings demonstrate that the inverted ILM flap technique has better efficacy than the ILM peeling technique for patients with myopic MH in closure rate, foveal microstructure and postoperative BCVA.


Subject(s)
Basement Membrane/surgery , Fovea Centralis/physiopathology , Myopia, Degenerative/complications , Retinal Perforations/surgery , Surgical Flaps , Visual Acuity/physiology , Adolescent , Adult , Aged , Coloring Agents/administration & dosage , Endotamponade/methods , Female , Fluorocarbons/administration & dosage , Humans , Indocyanine Green/administration & dosage , Male , Middle Aged , Myopia, Degenerative/physiopathology , Retinal Perforations/etiology , Retinal Perforations/physiopathology , Retrospective Studies , Treatment Outcome , Vitrectomy/methods , Young Adult
7.
Int J Ophthalmol ; 9(9): 1294-8, 2016.
Article in English | MEDLINE | ID: mdl-27672594

ABSTRACT

AIM: To report a simple approach to actively remove high viscosity silicone oil through a 23-gauge cannula via pars plana. METHODS: Forty-eight eyes of 48 patients underwent silicone oil (5700 centistokes) removal (SOR) were enrolled. A section of blood transfusion set was prepared to connect a standard 23-gauge cannula and vitrectomy machine. Silicone oil was removed with suction of 500-mm Hg vacuum through the cannula. Main outcome measures were SOR duration, number of sutured sites, intraocular pressure (IOP), best-corrected visual acuity (BCVA), and complications. RESULTS: Silicone oil was successfully removed in all cases. The mean SOR time was 5.70±0.85min. Nine eyes (18.75%) needed suture partial sclerotomies. No intraoperative complications were noted. Transient hypotony (≤8 mm Hg) was seen in 3 eyes (6.25%) on postoperative day 1, but all resolved within 1wk. Retinal reattachment was achieved in all cases and no other postoperative complications were noted during 3-month following-up. BCVA at the final visit improved or stabilized in all patients comparing to the preoperative level. CONCLUSION: Active removal of high viscosity silicone oil through a 23-gauge instrument cannula jointed with blood transfusion set is a practical and reliable technique when considering two sides of efficacy and safety.

8.
Int J Ophthalmol ; 6(6): 892-4, 2013.
Article in English | MEDLINE | ID: mdl-24392344

ABSTRACT

Transscleral suturing is a commonly applied technique to fix intraocular implants in the sulcus. A major problem after transscleral implantation is suture erosion that normally happens in the late post-surgery period and may result in an increased incidence of endophthalmitis. Here we describe an original cauterization method by using a glass rod to melt the exposed suture end without damaging the suture knot in the sclera to avoid suture exposure in sclera-fixed IOL implantation. This is a simple, quick and effective technique that can be performed without conjunctiva incisions and will help to reduce suture erosion related complications.

SELECTION OF CITATIONS
SEARCH DETAIL