Artif Organs ; 46(1): 71-82, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34287976

ABSTRACT

The objective of this study is to identify the preload and afterload sensitivity of the ReinHeart TAH 2.0. For adequate left-right flow balance, the concept of a reduced right stroke volume (by about 10%) and active adaption of the right diastole duration are evaluated concerning the controllability of the flow balance. This study used an active mock circulation loop to test a wide range of preload and afterload conditions. Preload sensitivity was tested at atrial pressures (APs) between 4 and 20 mm Hg. Left afterload was varied in a range of 60-140 mm Hg mean aortic pressure (MAP), right afterload was simulated between 15 and 40 mm Hg. Four scenarios were developed to verify that the flow difference fully covers the defined target range of 0-1.5 L/min. Although a positive correlation between inlet pressure and flow is identified for the right pump chamber, the left pump chamber already fills completely at an inlet pressure of 8-10 mm Hg. With increasing afterload, both the left and right flow decrease. A positive flow balance (left flow exceeds right flow) is achieved over the full range of tested afterloads. At high APs, the flow difference is limited to a maximum of 0.7 L/min. The controllability of flow balance was successfully evaluated in four scenarios, revealing that a positive flow difference can be achieved over the full range of MAPs. Under physiological test conditions, the linear relationship between flow and heart rate was confirmed, ensuring good controllability of the TAH.


Subject(s)
Blood Circulation , Heart, Artificial , Prosthesis Design , Blood Pressure , Heart Rate , Hydrodynamics , Models, Cardiovascular
2.
Artif Organs ; 46(3): 412-426, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34606117

ABSTRACT

BACKGROUND: Membranes based on triply periodic minimal surfaces (TPMS) have proven a superior gas transfer compared to the contemporary hollow fiber membrane (HFM) design in artificial lungs. The improved oxygen transfer is attributed to disrupting the laminar boundary layer adjacent to the membrane surface known as main limiting factor to mass transport. However, it requires experimental proof that this improvement is not at the expense of greater damage to the blood. Hence, the aim of this work is a valid statement regarding the structure-dependent hemolytic behavior of TPMS structures compared to the current HFM design. METHODS: Hemolysis tests were performed on structure samples of three different kind of TPMS-based designs (Schwarz-P, Schwarz-D and Schoen's Gyroid) in direct comparison to a hollow fiber structure as reference. RESULTS: The results of this study suggest that the difference in hemolysis between TPMS membranes compared to HFMs is small although slightly increased for the TPMS membranes. There is no significant difference between the TPMS structures and the hollow fiber design. Nevertheless, the ratio between the achieved additional oxygen transfer and the additional hemolysis favors the TPMS-based membrane shapes. CONCLUSION: TPMS-shaped membranes offer a safe way to improve gas transfer in artificial lungs.


Subject(s)
Artificial Organs , Hemolysis , Lung , Membranes, Artificial , Equipment Design , Humans , Printing, Three-Dimensional
3.
J Artif Organs ; 25(1): 1-8, 2022 Mar.
Article in English | MEDLINE | ID: mdl-33956261

ABSTRACT

An in-vitro study was conducted to investigate the general feasibility of using only one pumping chamber of the SynCardia total artificial heart (TAH) as a replacement of the single ventricle palliated by Fontan circulation. A mock circulation loop was used to mimic a Fontan circulation. The combination of both ventricle sizes (50 and 70 cc) and driver (Freedom Driver and Companion C2 Driver) was investigated. Two clinical relevant scenarios (early Fontan; late Fontan) as derived from literature data were set up in the mock loop. The impact of increased transpulmonary pressure gradient, low atrial pressure, and raised central venous pressure on cardiac output was studied. From a hemodynamic point, the single-chambered TAH performed sufficiently in the setting of the Fontan circulation. Increased transpulmonary pressure gradient, from ideal to pulmonary hypertension, decreased the blood flow in combinations by almost 2 L/min. In the early Fontan scenario, a cardiac output of 3-3.5 L/min was achieved using the 50 cc ventricle, driven by the Companion C2 Driver. Even under pulmonary hypertension, cardiac outputs greater than 4 L/min could be obtained with the 70 cc pump chamber in the late Fontan scenario. In the clinically relevant Fontan scenarios, implementation of the single chambered TAH performed successfully from a hemodynamic point of view. The replacement of the failing univentricular heart by a single chamber of the SynCardia TAH may provide an alternative to a complex biventricular repair procedure or ventricular support in Fontan patients.


Subject(s)
Fontan Procedure , Heart Defects, Congenital , Heart, Artificial , Cardiac Output , Fontan Procedure/methods , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/surgery , Heart Ventricles/surgery , Hemodynamics/physiology , Humans
4.
Artif Organs ; 45(1): 68-78, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32750157

ABSTRACT

Transcatheter aortic valve replacement (TAVR) has emerged as a widely used therapy for aortic valve diseases. With TAVR, flow hemodynamics may change leading to areas of flow stagnation prone to thrombosis risk. The neo-sinus, created by introducing a prosthesis inside the diseased native valve, may prompt leaflet thrombosis due to areas of flow stasis. This study attempted to understand the effect of different prosthesis implant depths on the flow field within the neo- and native sinus and on the coronary perfusion. Experiments were performed inside an in vitro pulse duplicator producing physiological conditions according to ISO 5840-1:2015 standard. Flow fields were obtained for two cardiac outputs (CO) using particle image velocimetry (PIV). Washout was calculated as a measure of flow stasis. The two main results are: a lower implant position and a lower CO/frequency led to better native sinus washout, but worsened neo-sinus washout. In contrast, a higher implant position led to higher coronary flow (for higher CO/frequency). No significant effect of implant depth on coronary flow was observed for lower CO/frequency. In summary, a higher implant position using this self-expanding prosthesis is associated with reduced neo-sinus flow stasis. Hereby, washout of the native sinus, as well as coronary flow, are dependent on cardiac output.


Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis/adverse effects , Models, Cardiovascular , Prosthesis Design , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/physiopathology , Aortic Valve/surgery , Aortic Valve Stenosis/physiopathology , Blood Flow Velocity , Cardiac Output , Coronary Circulation , Humans , Rheology , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
5.
ASAIO J ; 70(7): 579-585, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38386997

ABSTRACT

Rotary blood pumps in Extracorporeal Life Support (ECLS) applications are optimized for a specific design point. However, in clinical practice, these pumps are usually applied over a wide range of operation points. Studies have shown that a deviation from the design point in a rotary blood pump leads to an unexpected rise of hemolysis with corresponding clinical complications. Adjustable pumps that can adapt geometric parameters to the respective operation point are commonly used in other industrial branches, but yet not applied in blood pumps. We present a novel mechanism to adjust the impeller geometry of a centrifugal blood pump during operation together with in-vitro data of its hydraulic performance and efficiency. Three-dimensionalprinted prototypes of the adjustable impeller and a rigid impeller were manufactured and hydraulic performance and efficiency measured (n = 3). In a flow range of 1.5-9.5 L/min, the adjustable pump increased pump performance up to 47% and hydraulic efficiency by an average of 7.3 percentage points compared with a fixed setting. The adjustable pump allows customization of the pump's behavior (steepness of performance curve) according to individual needs. Furthermore, the hydraulic efficiency of the pump could be maintained at a high level throughout the complete flow range.


Subject(s)
Heart-Assist Devices , Humans , Equipment Design , Hemolysis
6.
Sci Rep ; 12(1): 7160, 2022 05 03.
Article in English | MEDLINE | ID: mdl-35504939

ABSTRACT

Membrane lungs consist of thousands of hollow fiber membranes packed together as a bundle. The devices often suffer from complications because of non-uniform flow through the membrane bundle, including regions of both excessively high flow and stagnant flow. Here, we present a proof-of-concept design for a membrane lung containing a membrane module based on triply periodic minimal surfaces (TPMS). By warping the original TPMS geometries, the local permeability within any region of the module could be raised or lowered, allowing for the tailoring of the blood flow distribution through the device. By creating an iterative optimization scheme for determining the distribution of streamwise permeability inside a computational porous domain, the desired form of a lattice of TPMS elements was determined via simulation. This desired form was translated into a computer-aided design (CAD) model for a prototype device. The device was then produced via additive manufacturing in order to test the novel design against an industry-standard predicate device. Flow distribution was verifiably homogenized and residence time reduced, promising a more efficient performance and increased resistance to thrombosis. This work shows the promising extent to which TPMS can serve as a new building block for exchange processes in medical devices.


Subject(s)
Lung , Computer Simulation , Membranes , Permeability , Porosity