Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Journal subject
Affiliation country
Publication year range
1.
BMC Med Imaging ; 21(1): 135, 2021 09 25.
Article in English | MEDLINE | ID: mdl-34563164

ABSTRACT

BACKGROUND: Non-contrast FLAIR revealed increased signal within the inner ear in patients with vestibular schwannoma, which is generally assumed to occur in the perilymph; however, the majority of previous studies did not differentiate between the endolymph and perilymph. Therefore, endolymph signal changes have not yet been investigated in detail. The purpose of the present study was three-fold: (1) to assess perilymph signal changes in patients with vestibular schwannoma on heavily T2-weighted (T2W) 3D FLAIR, also termed positive perilymphatic images (PPI), (2) to evaluate signal and morphological changes in the endolymph on PPI, and (3) to establish whether vertigo correlates with the signal intensity ratios (SIR) of the vestibular perilymph or vestibular endolymphatic hydrops. METHODS: Forty-two patients with unilateral vestibular schwannoma were retrospectively recruited. We semi-quantitatively and qualitatively evaluated the perilymph signal intensity on the affected and unaffected sides. We also quantitatively examined the signal intensity of the vestibular perilymph and assessed the relationship between vertigo and the SIR of the vestibular perilymph on the affected side. We semi-quantitatively or qualitatively evaluated the endolymph, and investigated whether vestibular hydrops correlated with vertigo. RESULTS: The perilymph on the affected side showed abnormal signal more frequently (signal intensity grade: overall mean 1.45 vs. 0.02; comparison of signal intensity: overall mean 36 vs. 0 cases) and in more parts (the entire inner ear vs. the basal turn of the cochlea and vestibule) than that on the unaffected side. No significant difference was observed in the SIR of the vestibular perilymph with and without vertigo (5.54 vs. 5.51, p = 0.18). The endolymph of the vestibule and semicircular canals showed the following characteristic features: no visualization (n = 4), signal change (n = 1), or vestibular hydrops (n = 10). A correlation was not observed between vestibular hydrops and vertigo (p = 1.000). CONCLUSIONS: PPI may provide useful information on signal and morphological changes in the endolymph of patients with vestibular schwannoma. Further research is warranted to clarify the relationship between vertigo and the MR features of the inner ear.


Subject(s)
Endolymph/diagnostic imaging , Endolymphatic Hydrops/diagnostic imaging , Magnetic Resonance Imaging , Neuroma, Acoustic/diagnostic imaging , Perilymph/diagnostic imaging , Adult , Aged , Aged, 80 and over , Endolymph/physiology , Female , Humans , Male , Middle Aged , Neuroma, Acoustic/pathology , Neuroma, Acoustic/physiopathology , Perilymph/physiology , Retrospective Studies , Vertigo/etiology
2.
Magn Reson Med Sci ; 21(3): 469-476, 2022 Jul 01.
Article in English | MEDLINE | ID: mdl-33980787

ABSTRACT

PURPOSE: The purpose of the present study was to evaluate contrast enhancement of the infundibular recess in the normal state using heavily T2-weighted 3D fluid-attenuated inversion recovery (FLAIR) (HT2-FLAIR). METHODS: Twenty-six patients were retrospectively recruited. We subjectively assessed overall contrast enhancement of the infundibular recess between postcontrast, 4-hour (4-h) delayed postcontrast, and precontrast HT2-FLAIR images. We also objectively conducted chronological and spatial comparisons by measuring the signal intensity (SI) ratio (SIR). Chronological comparisons were performed by comparing SI of the infundibular recess/SI of the midbrain (SIRIR-MB). Spatial comparisons were conducted by comparing SI on postcontrast HT2-FLAIR/SI on precontrast HT2-FLAIR (SIRPost-Pre) of the infundibular recess with that of other cerebrospinal fluid (CSF) spaces, including the superior part of the third ventricle, lateral ventricles, fourth ventricle, and interpeduncular cistern. RESULTS: In the subjective analysis, all cases showed contrast enhancement of the infundibular recess on both postcontrast and 4-h delayed postcontrast HT2-FLAIR, and showed weaker contrast enhancement of the infundibular recess on 4-h delayed postcontrast HT2-FLAIR than on postcontrast HT2-FLAIR. In the objective analysis, SIRIR-MB was the highest on postcontrast images, followed by 4-h delayed postcontrast images. SIRPost-Pre was significantly higher in the infundibular recess than in the other CSF spaces. CONCLUSION: The present results demonstrated that the infundibular recess was enhanced on HT2-FLAIR after an intravenous gadolinium injection. The infundibular recess may be a potential source of the leakage of intravenously administered gadolinium into the CSF.


Subject(s)
Gadolinium , Third Ventricle , Contrast Media , Humans , Magnetic Resonance Imaging/methods , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL