ABSTRACT
Background: Transcatheter aortic valve replacement (TAVR) is known to increase the incidence of conduction disturbances compared to surgical aortic valve replacement; however, there are limited data on the impact and duration of these conduction disturbances on longer term outcomes. Objective: To determine the differential impact of persistent versus nonpersistent new-onset conduction disturbances on TAVR-related complications and outcomes. Methods: This is a single-center retrospective analysis of 927 consecutive patients with aortic stenosis who underwent TAVR at Yale New Haven Hospital from July 2012 to August 2019. Patients with new-onset conduction disturbances within 7 days following TAVR were selected for this study. Persistent and nonpersistent disturbances were, respectively, defined as persisting or not persisting on all patient ECGs for up to 1.5 years after TAVR or until death. Results: Within 7 days after TAVR, conduction disturbances occurred in 42.3% (392/927) of the patients. Conduction disturbances persisted in 150 (38%) patients and did not persist in 187 (48%) patients, and 55 (14%) patients were excluded for having mixed (both persistent and nonpersistent) disturbances. Compared with nonpersistent disturbances, patients with persistent disturbances were more likely to receive a PPM within 7 days after the TAVR procedure (46.0% versus 4.3%, p < 0.001) and had a greater unadjusted 1-year cardiac-related and all-cause mortality risk (HR 2.54, p=0.044 and HR 1.90, p=0.046, respectively). Conclusion: Persistent conduction disturbances were associated with a greater cardiac and all-cause mortality rate at one year following TAVR. Future research should investigate periprocedural factors to reduce persistent conduction disturbances and outcomes beyond one year follow-up.
Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Retrospective Studies , Treatment Outcome , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Risk FactorsABSTRACT
Many novel percutaneous interventions are being developed for application in the tricuspid valve position. At the present time, there are no commercially available devices for this application. There has been mounting evidence supporting the safety and efficacy of using the MitraClip system on the tricuspid valve. This review summarizes the peer reviewed data available to date supporting this procedure, outlines the step-by-step maneuvers using the MitraClip system for this application, and imaging techniques used prior to and during the procedure.
Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Tricuspid Valve Insufficiency , Cardiac Catheterization/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Surgical Instruments , Treatment Outcome , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgeryABSTRACT
Transcatheter aortic valve replacement is an approved treatment for select patients with severe aortic stenosis. A rare complication of self-expanding transcatheter heart valves (THVs) is infolding of the valve stent frame, which results in a malopposed segment, perivalvular aortic insufficiency, and possibly leaflet dysfunction. We report here a successful case of balloon valvuloplasty treatment for severe infolding of a self-expandable THV in the aortic position, restoring stent frame geometry and leaflet function. © 2015 Wiley Periodicals, Inc.
Subject(s)
Aortic Valve Stenosis/therapy , Aortic Valve , Balloon Valvuloplasty , Cardiac Catheterization/instrumentation , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Prosthesis Failure , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Humans , Prosthesis Design , Radiography, Interventional , Severity of Illness Index , Treatment OutcomeABSTRACT
OBJECTIVES: We sought to examine whether baseline diastolic dysfunction (DD) is associated with increased mortality in patients who develop aortic insufficiency (AI) after transcatheter aortic valve replacement (TAVR). BACKGROUND: Significant post-TAVR AI is associated with increased mortality, likely secondary to adverse hemodynamics secondary to volume overload and decreased LV compliance from chronic pressure overload. However, the effect of baseline DD on outcomes of patients with post-TAVR AI has not been studied. METHODS: A total of 195 patients undergoing TAVR were included in the study. Patients with moderate-to-severe mitral stenosis, prior mitral valve replacement or atrial fibrillation were excluded. DD was classified at baseline by a 2-step approach as recommended by the American Society of Echocardiography while AI was evaluated 30 days post-TAVR. Follow up data up to 2 years post-TAVR was used in survival analysis. RESULTS: Patients with severe baseline DD who developed ≥mild post-TAVR AI had increased mortality compared to all other patients (HR = 3.89, CI: 1.76-8.6, P = 0.001), which remained significant after adjusting for post-TAVR AI, pre-TAVR AI, baseline mitral regurgitation, ejection fraction, pulmonary artery pressure, creatinine clearance and history of stroke. CONCLUSIONS: Even mild post-TAVR AI may have a negative impact on outcomes of patients with underlying severe DD. © 2016 Wiley Periodicals, Inc.
Subject(s)
Aortic Valve Insufficiency/etiology , Aortic Valve Stenosis/therapy , Aortic Valve , Cardiac Catheterization/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Ventricular Dysfunction, Left/complications , Ventricular Function, Left , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Cardiac Catheterization/instrumentation , Cardiac Catheterization/methods , Cardiac Catheterization/mortality , Diastole , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/mortality , Humans , Kaplan-Meier Estimate , Male , Proportional Hazards Models , Retrospective Studies , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Treatment Outcome , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/mortality , Ventricular Dysfunction, Left/physiopathologyABSTRACT
BACKGROUND: Paravalvular aortic regurgitation (PAR) remains a common complication following transcatheter aortic valve replacement (TAVR), and has been associated with increased mortality. Adverse left ventricular (LV) remodelling has been reported in patients with post-TAVR PAR, but the association between adverse LV remodeling and increased mortality remains unclear. The aim of the present study was to examine the association between PAR, LV remodeling and mortality following TAVR in a non-PARTNER (Placement of Aortic Transcatheter Valves) trial population. METHODS: A total of 195 patients that underwent TAVR was included in the study. The LV ejection fraction (LVEF), LV mass index (LVMI), LV internal dimension at systole (LVIDs) and diastole (LVIDd) were compared between patients with different degrees of PAR at baseline, and at one month and one year after TAVR. Survival analysis was performed for different degrees of PAR and LV remodeling. RESULTS: PAR ≥moderate was associated with increased mortality (HR 4.58 [1.80-11.63], p = 0.001), but PAR >mild was not. The LVIDd and LVIDs were persistently increased at one year after TAVR in patients with PAR >mild compared to those with PAR ≤mild (5.9 ± 0.8 cm versus 5.4 ± 0.7 cm, p = 0.02 and 4.4 ± 0.8 cm versus 3.9 ± 0.8, p = 0.03, respectively). The LVEF was improved similarly between the two groups at one year after TAVR (p = 0.1). Patients with PAR ≥moderate had significantly more adverse LV remodeling at one month after TAVR in terms of LVIDd, LVIDs, and LVMI. The degree of remodeling as expressed in terms of LVIDd, LVIDs, LVMI and LVEF changes from baseline did not have a direct impact on mortality. CONCLUSIONS: A worse PAR was associated with more adverse LV remodeling and a higher mortality after TAVR in a non-PARTNER patient population.
Subject(s)
Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/mortality , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Ventricular Function, Left , Ventricular Remodeling , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnosis , Aortic Valve Insufficiency/physiopathology , Databases, Factual , Female , Humans , Kaplan-Meier Estimate , Male , Proportional Hazards Models , Recovery of Function , Retrospective Studies , Risk Factors , Severity of Illness Index , Stroke Volume , Time Factors , Treatment OutcomeABSTRACT
BACKGROUND: Early studies on transcatheter aortic valve replacement (TAVR) outcomes showed that female sex was associated with better survival. With increased use of new-generation valves, the impact of sex on contemporary TAVR outcomes is less well known. METHODS: Retrospective analysis using institutional National Cardiovascular Data Registry STS/ACC TVT data was performed on all patients undergoing TAVR at Yale New Haven Hospital from July 2012 to August 2019. New-generation valves were Evolut PRO, Evolut R, and SAPIEN 3. Old-generation valves were CoreValve, SAPIEN, and SAPIEN XT. Log-rank test and Kaplan-Meier curves were used to compare sex differences in survival up to 1 year after TAVR. Cox modeling was used to adjust for baseline and procedural characteristic differences. RESULTS: 927 consecutive patients (41.4% women) underwent TAVR. Women were older (82.8 vs 80.6 years old; p < 0.001) with higher STS mortality scores compared with men (7.6% vs 6.4%; p < 0.001) despite lower prevalence of cardiovascular comorbidities including coronary artery disease, peripheral artery disease, and smoking. Most cases used transfemoral access (90.5%) and new-generation devices (72.3%). Women received smaller valves compared with men (20-26 mm: 78.0% vs 32.9%; 29-34 mm: 22.1% vs 67.1%; overall p < 0.0001). There were no statistically significant differences between sexes in both unadjusted and adjusted 1-year mortality. CONCLUSION: Our data show no significant difference in 1-year survival between sexes using primarily new generation valves. Further studies should reassess the impact of sex on TAVR outcomes and whether newer technologies like new valve design and sizes, and CT imaging may have eliminated sex-based disparities.
Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Female , Male , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Retrospective Studies , Treatment Outcome , Prosthesis Design , Risk FactorsABSTRACT
PURPOSE: To establish an ex vivo experimental setup for imaging coronary atherosclerosis with coronary computed tomographic (CT) angiography, intravascular ultrasonography (US), and optical frequency domain imaging (OFDI) and to investigate their ability to help differentiate early from advanced coronary plaques. MATERIALS AND METHODS: All procedures were performed in accordance with local and federal regulations and the Declaration of Helsinki. Approval of the local Ethics Committee was obtained. Overall, 379 histologic cuts from nine coronary arteries from three donor hearts were acquired, coregistered among modalities, and assessed for the presence and composition of atherosclerotic plaque. To assess the discriminatory capacity of the different modalities in the detection of advanced lesions, c statistic analysis was used. Interobserver agreement was assessed with the Cohen κ statistic. RESULTS: Cross sections without plaque at coronary CT angiography and with fibrous plaque at OFDI almost never showed advanced lesions at histopathologic examination (odds ratio [OR]: 0.02 and 0.06, respectively; both P<.0001), while mixed plaque at coronary CT angiography, calcified plaque at intravascular US, and lipid-rich plaque at OFDI were associated with advanced lesions (OR: 2.49, P=.0003; OR: 2.60, P=.002; and OR: 31.2, P<.0001, respectively). OFDI had higher accuracy for discriminating early from advanced lesions than intravascular US and coronary CT angiography (area under the receiver operating characteristic curve: 0.858 [95% confidence interval {CI}: 0.802, 0.913], 0.631 [95% CI: 0.554, 0.709], and 0.679 [95% CI: 0.618, 0.740]; respectively, P<.0001). Interobserver agreement was excellent for OFDI and coronary CT angiography (κ=0.87 and 0.85, respectively) and was good for intravascular US (κ=0.66). CONCLUSION: Systematic and standardized comparison between invasive and noninvasive modalities for coronary plaque characterization in ex vivo specimens demonstrated that coronary CT angiography and intravascular US are reasonably associated with plaque composition and lesion grading according to histopathologic findings, while OFDI was strongly associated. These data may help to develop initial concepts of sequential imaging strategies to identify patients with advanced coronary plaques.
Subject(s)
Coronary Angiography/methods , Coronary Artery Disease/diagnosis , Tomography, Optical Coherence/methods , Tomography, X-Ray Computed/methods , Ultrasonography, Interventional/methods , Cadaver , Diagnosis, Differential , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Severity of Illness IndexABSTRACT
OBJECTIVE: Implantation of a transcatheter valve-in-mitral annular calcification (ViMAC) has emerged as an alternative to traditional surgical mitral valve (MV) replacement. Previous studies evaluating ViMAC aggregated transseptal, transapical, and transatrial forms of the procedure, leaving uncertainty about each technique's advantages and disadvantages. Thus, we sought to evaluate clinical outcomes specifically for transatrial ViMAC from the largest multicenter registry to-date. METHODS: Patients with symptomatic MV dysfunction and severe MAC who underwent ViMAC were enrolled from 12 centers across the United States and Europe. Clinical characteristics, procedural details, and clinical outcomes were abstracted from the electronic record. The primary end point was all-cause mortality. RESULTS: We analyzed 126 patients who underwent ViMAC (median age 76 years [interquartile range {IQR}, 70-82 years], 28.6% female, median Society of Thoracic Surgeons score 6.8% [IQR, 4.0-11.4], and median follow-up 89 days [IQR, 16-383.5]). Sixty-one (48.4%) had isolated mitral stenosis, 25 (19.8%) had isolated mitral regurgitation (MR), and 40 (31.7%) had mixed MV disease. Technical success was achieved in 119 (94.4%) patients. Thirty (23.8%) patients underwent concurrent septal myectomy, and 8 (6.3%) patients experienced left ventricular outflow tract obstruction (7/8 did not undergo myectomy). Five (4.2%) patients of 118 with postprocedure echocardiograms had greater than mild paravalvular leak. Thirty-day and 1-year all-cause mortality occurred in 16 and 33 patients, respectively. In multivariable models, moderate or greater MR at baseline was associated with increased risk of 1-year mortality (hazard ratio, 2.31; 95% confidence interval, 1.07-4.99, P = .03). CONCLUSIONS: Transatrial ViMAC is safe and feasible in this selected, male-predominant cohort. Patients with significant MR may derive less benefit from ViMAC than patients with mitral stenosis only.
ABSTRACT
With heightened awareness of mitral valve disease and improvement in surgical techniques, the use of mitral valve bioprostheses has increased. There is a large aging population with prior surgical valvular interventions. Limited durability of the prosthesis due to valvular degeneration over time may necessitate the need for repair or replacement of the prior prosthesis in the future. This usually entails another surgical intervention in this population with elevated risk for a reoperation. There is an ongoing clinical need for newer, less invasive options that are feasible and carry a lower complication rate. The advent of transcatheter heart valve (THV) therapies has opened up a wide range of therapeutic options for treatment of a failed bioprosthesis. Their safety and feasibility are now well established. This article serves as a review of the currently available THVs for implantation in the mitral position, the pre-procedural assessment, the challenges associated with implantation, as well as outcomes associated with a mitral valve-in-valve (VIV) and a mitral valve-in-ring (VIR) procedure.
ABSTRACT
In 2013, the Food and Drug Administration approved the first transcatheter mitral valve repair (TMVr) device for degenerative mitral regurgitation for patients at prohibitive surgical risk. To better understand contemporary utilization trends and outcomes, we reviewed hospitalizations, identified using International Classification of Diseases, Ninth Revision and International Classification of Diseases, Tenth Revision codes, in which the patient underwent TMVr or mitral valve repair (MVr) with a diagnosis of mitral regurgitation, without stenosis, from the National (Nationwide) Inpatient Sample from 2014 to 2017. We included 10,020 hospitalizations in which the patient underwent TMVr and 5845 in which the patient underwent MVr and assessed trends in demographic characteristics, patient comorbidities, total hospital charges, and outcomes. Transcatheter mitral valve repair experienced exponential growth, increasing from 150 to 5115 over the study period (P<.001 for trend), whereas MVr grew to a lesser degree. The median length of stay for TMVr decreased from 4 to 2 days; mortality declined from 3.3% to 1.6% (P<.001 for both). Both TMVr and MVr rates of discharge home increased over the study period. Total charges for TMVr increased from $149,582 to $178,109, whereas those for MVr increased to a lesser degree, from $149,426 to $157,146 (P<.001 for both). Discharge disposition, length of stay, and in-hospital mortality all exhibited favorable trends for both procedures. Caution must be exercised in direct comparisons between procedures as they target somewhat different populations. With expanded indications for TMVr, we anticipate further increases in procedural volume, although the effect on MVr remains unclear.
Subject(s)
Heart Valve Prosthesis Implantation/methods , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Age Factors , Aged , Female , Health Care Costs , Heart Valve Prosthesis Implantation/economics , Humans , Length of Stay/statistics & numerical data , Male , Middle Aged , Retrospective StudiesABSTRACT
OBJECTIVES: The aim of this study was to assess the outcomes of severe prosthesis-patient mismatch (PPM) in the TVT (Transcatheter Valve Therapy) Registry in patients undergoing supra-annular transcatheter aortic valve replacement (TAVR) for de novo stenosis or failed surgical bioprostheses (transcatheter aortic valve [TAV]-in-surgical aortic valve [SAV]). BACKGROUND: Severe PPM has been associated with adverse outcomes following TAVR, yet the clinical outcome of severe PPM after supra-annular TAVR is largely unknown. METHODS: Supra-annular TAVR was performed in patients enrolled in the TVT Registry with de novo stenosis (n = 42,174) or TAV-in-SAV (n = 5,446). Valve Academic Research Consortium-3 criteria were used to define severe PPM. The clinical impact of severe PPM on 1-year mortality and valve-related readmission was assessed using multivariate regression. A generalized linear mixed model was used to evaluate predictors of severe PPM. RESULTS: Severe PPM was found in 5.3% of patients undergoing de novo TAVR and 27.0% of patients undergoing TAV-in-SAV. The presence of severe PPM was not significantly associated with 1-year mortality or valve-related readmissions in both groups. Mean aortic gradients were higher in patients with severe PPM than in those without severe PPM at 1 month (9.7 ± 5.7 mm Hg vs. 7.3 ± 4.0 mm Hg; p < 0.001) and 1 year (10.2 ± 6.4 mm Hg vs. 8.0 ± 4.3 mm Hg; p < 0.001). Pre-procedural factors, including a <20-mm aortic annulus, were positive predictors of severe PPM in patients undergoing de novo TAVR (area under the curve = 0.795) and TAV-in-SAV (area under the curve = 0.764). CONCLUSIONS: Severe PPM after supra-annular TAVR was not associated with increased 1-year mortality or valve-related readmissions. Longer-term follow-up is needed to determine if higher residual gradients in patients with severe PPM predict long-term outcomes. (STS/ACC Transcatheter Valve Therapy Registry [TVT Registry]; NCT01737528).
Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Prosthesis Design , Registries , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment OutcomeABSTRACT
OBJECTIVES: This study sought to compare outcomes in patients with bicuspid versus tricuspid anatomy undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR has shown excellent safety and efficacy in patients with tricuspid aortic valve stenosis, but limited data are available on the use of self-expanding valves in patients with bicuspid valves. METHODS: The Society of Thoracic Surgeons/American College of Cardiology TVT Registry was used to analyze patients who underwent TAVR with the Evolut R or Evolut PRO valves. Clinical and echocardiographic outcomes were analyzed through 1-year follow-up. RESULTS: Between July 2015 and September 2018 a total of 932 patients with bicuspid aortic valve stenosis underwent elective TAVR with the self-expanding Evolut R or Evolut PRO valve. These patients were compared with a group of 26,154 patients with tricuspid aortic stenosis who underwent TAVR during that same time period. At baseline, patients with bicuspid valves were younger, had fewer cardiac comorbidities, and had lower Society of Thoracic Surgeons Predicted Risk of Mortality scores (5.3 ± 4.2% vs. 6.9 ± 4.8%; p < 0.001). To account for these differences, propensity matching was performed, which resulted in 929 matched pairs. Within these match groups, the rates of all-cause mortality at 30 days (2.6% vs. 1.7%; p = 0.18) and 1 year (10.4% vs. 12.1%; p = 0.63), as well the rate of stroke at 30 days (3.4% vs. 2.7%; p = 0.41) and 1 year (3.9% vs. 4.4%; p = 0.93), were comparable. CONCLUSIONS: All-cause mortality, stroke, and valve hemodynamics did not differ at 30 days or 1 year between patient groups. In patients at increased surgical risk, TAVR for bicuspid aortic valve stenosis indicates acceptable safety outcomes with low complications rates.
Subject(s)
Aortic Valve Stenosis/surgery , Bicuspid Aortic Valve Disease/surgery , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/mortality , Bicuspid Aortic Valve Disease/physiopathology , Female , Heart Valve Prosthesis , Hemodynamics , Humans , Male , Middle Aged , Postoperative Complications/mortality , Prosthesis Design , Recovery of Function , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United StatesABSTRACT
OBJECTIVES: The aim of this study was to assess the evolution of early outcomes for 3 iterative self-expanding transcatheter aortic valves. BACKGROUND: Over the past decade there have been rapid advancements in transcatheter aortic valve replacement (TAVR) technologies, including 3 generations of supra-annular self-expanding transcatheter systems. METHODS: Data from the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry for patients undergoing TAVR with CoreValve, Evolut R, or Evolut PRO valves to treat tricuspid aortic stenosis between January 2014 and September 2017 were obtained. Patient risk and echocardiographic data are site reported. Valves analyzed included 23-, 26-, and 29-mm sizes to fit 18- to 26-mm annular diameters. Propensity score matching was performed using the Evolut PRO group as the common reference. RESULTS: Of 18,874 patients undergoing TAVR at 381 centers, 5,514 patients were implanted with CoreValve, 11,295 with Evolut R, and 2,065 with Evolut PRO valves. At 30 days, there were significantly fewer patients with more than mild aortic regurgitation for the unmatched (7.8% CoreValve, 5.2% Evolut R, and 2.8% Evolut PRO; p < 0.001) and matched populations (8.3% CoreValve, 5.4% Evolut R, and 3.4% Evolut PRO; p = 0.032). The mean aortic valve gradients at 30 days in the matched populations were <8 mm Hg for all 3 valves (7.3 mm Hg CoreValve, 7.5 mm Hg Evolut R, 7.2 mm Hg Evolut PRO). CONCLUSIONS: Advancements in transcatheter valve technologies and expanding indications for TAVR have resulted in improved outcomes for patients undergoing TAVR in the United States with self-expanding, supra-annular valves. In particular, the addition of an outer pericardial tissue wrap designed to enhance sealing at the level of the aortic annulus has resulted in very low rates of significant aortic regurgitation while maintaining excellent hemodynamic status.
Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Hemodynamics , Humans , Male , Prosthesis Design , Recovery of Function , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United StatesABSTRACT
OBJECTIVES: The aim of this study was to evaluate the impact of initial deployment orientation of SAPIEN 3, Evolut, and ACURATE-neo transcatheter heart valves on their final orientation and neocommissural overlap with coronary arteries. BACKGROUND: Coronary artery access and redo transcatheter aortic valve replacement (TAVR) following initial TAVR may be influenced by transcatheter heart valve orientation. In this study the impact of transcatheter heart valve deployment orientation on commissural alignment was evaluated. METHODS: Pre-TAVR computed tomography and procedural fluoroscopy were analyzed in 828 patients who underwent TAVR (483 SAPIEN 3, 245 Evolut, and 100 ACURATE-neo valves) from March 2016 to September 2019 at 5 centers. Coplanar fluoroscopic views were coregistered to pre-TAVR computed tomography to determine commissural alignment. Severe overlap between neocommissural posts and coronary arteries was defined as 0° to 20° apart. The SAPIEN 3 had 1 commissural post crimped at 3, 6, 9, and 12 o'clock. The Evolut "Hat" marker and ACURATE-neo commissural post at deployment were classified as center back (CB), inner curve (IC), outer curve (OC), or center front (CF) and matched with final orientation. RESULTS: Initial SAPIEN 3 crimped orientation had no impact on commissural alignment. Evolut "Hat" at OC or CF at initial deployment had less severe overlap than IC or CB (p < 0.001) against the left main (15.7% vs. 66.0%) and right coronary (7.1% vs. 51.1%) arteries. Tracking Evolut "Hat" at OC of the descending aorta (n = 107) improved OC at deployment from 70.2% to 91.6% (p = 0.002) and reduced coronary artery overlap by 36% to 60% (p < 0.05). ACURATE-neo commissural post at CB or IC during deployment had less coronary artery overlap compared to CF or OC (p < 0.001), with intentional alignment successful in 5 of 7 cases. CONCLUSIONS: This is the first systematic evaluation of commissural alignment in TAVR. More than 30% to 50% of cases had overlap with 1 or both coronary arteries. Initial SAPIEN 3 orientation had no impact on alignment, but specific initial orientations of Evolut and ACURATE improved alignment. Optimizing valve alignment to avoid coronary artery overlap will be important in coronary artery access and redo TAVR.
Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Coronary Vessels/diagnostic imaging , Heart Valve Prosthesis , Multidetector Computed Tomography , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Female , Fluoroscopy , Humans , Male , Pilot Projects , Predictive Value of Tests , Prosthesis Design , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , United StatesABSTRACT
Increased creatine kinase-MB levels and ST-segment depression are well-known prognostic factors in the setting of non-ST-elevation acute coronary syndrome (ACS). We hypothesized a relationship between virtual histology intravascular ultrasound (VH-IVUS) findings and these prognostic factors. We performed "whole vessel" VH-IVUS analysis in culprit arteries of 225 patients with ACS and measured the 4 basic VH-IVUS coronary plaque components--fibrous, fibrofatty, dense calcium (DC), and necrotic core (NC)--and calculated a NC/DC ratio. Patients' age was 62 +/- 11 years; 72% were men and 23% had diabetes. Only the NC/DC ratio had a positive association with creatine kinase-MB levels (r = 0.21, p = 0.03), and it was significantly higher for patients with ST-depression compared with those with non-ST-depression ACS (1.97 +/- 1.46 vs 1.58 +/- 1.10, p = 0.02). Sensitivity and specificity curves determined that a NC/DC value > or =2 (odds ratio 3.8, p = 0.01) and percentage of NC > or =6 (odds ratio 3.1, p = 0.04) were thresholds that best separated patients with high-risk non-ST-elevation ACS from those without abnormal creatine kinase-MB or ST depression. Patients with both predictors had significantly higher total cholesterol (204.7 +/- 60.5 vs 173.6 +/- 44.3 mg/dl, p = 0.01), higher low-density liprotein cholesterol (132.5 +/- 49.8 vs 101.3 +/- 33.2 mg/dl, p = 0.02), and more myocardial injury (creatine kinase-MB value of 42 +/- 38 vs 12 +/- 21, p = 0.01) than patients with no predictors. In conclusion, VH-IVUS analysis showed that the percentage of NC and its ratio to DC in diseased coronary segments are positively associated with a high-risk ACS presentation.
Subject(s)
Acute Coronary Syndrome/pathology , Calcinosis/pathology , Coronary Vessels/pathology , Biomarkers/blood , Cholesterol/blood , Coronary Artery Disease/pathology , Creatine Kinase/blood , Female , Fibrosis , Humans , Male , Middle Aged , Necrosis , Prognosis , Prospective Studies , Registries , Risk Assessment , Sensitivity and Specificity , Severity of Illness Index , Smoking/pathology , Tunica Media/pathology , Ultrasonography, InterventionalABSTRACT
With the rapid advance of transcatheter aortic valve implantation (TAVI), it is important to evaluate the relationship between TAVI volumes and outcomes. The aim of this study was to analyze in-hospital outcomes after TAVI stratified according to hospital volumes. Using the National Inpatient Sample files from 2012, hospitals performing transfemoral (TF)-TAVI and transapical (TA)-TAVI were divided into high-volume and low-volume centers. A total of 7,660 patients underwent TAVI in 256 hospitals in 2012. In the TF-TAVI cohort, multivariate logistic regression analyses demonstrated that low TF-TAVI volume status was an independent predictor of death and bleeding. In the TA-TAVI cohort, low volume status was a predictor of death, myocardial infarction, and need for permanent pacemaker. In addition, hospitals that performed low TA-TAVI volume were associated with significantly higher rate of death after surgical aortic valve replacement in comparison with the hospitals that perform high TA-TAVI volume (3.6% vs 2.3%, p <0.001). In conclusion, centers with lower volume of TAVI had more frequent adverse events compared with higher volume centers.
Subject(s)
Aortic Valve Stenosis/surgery , Postoperative Complications/epidemiology , Risk Assessment , Transcatheter Aortic Valve Replacement/statistics & numerical data , Aged , Aged, 80 and over , Female , Humans , Incidence , Male , Retrospective Studies , Risk Factors , Survival Rate/trends , Treatment Outcome , United States/epidemiologyABSTRACT
The aim of this study was to compare in-hospital cost and outcomes between transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR). TAVI is an effective treatment option in patients with symptomatic aortic stenosis who are at high risk for traditional SAVR. Several studies using trial data or outside United States registry data have addressed TAVI cost issues, although there is a paucity of cost data involving commercial cases in the United States. Using Agency for Healthcare Research and Quality Healthcare Cost and Utilization Project Nationwide Inpatient Sample files, a propensity score-matched analysis of all commercial TAVI and SAVR cases performed in 2011 was conducted. Overall hospital cost and length of stay, as well as procedural complications, were compared between the 2 matched cohorts: 595 TAVI patients were matched to 1,785 SAVR patients in a 1:3 ratio. There was no difference in mean ($181,912 vs $196,298) or median ($152,993 vs $155,974) hospital cost between TAVI and SAVR (p = 0.60). The TAVI group had significantly shorter lengths of hospital stay than the SAVR group (mean 9.76 vs 12.01 days, p <0.001). There was no difference in postprocedural in-hospital death or stroke, but TAVI patients were more likely to have bleeding complications, to have vascular complications, and to require pacemakers. In conclusion, when analyzing in-hospital cost of commercial TAVI and SAVR cases using the Nationwide Inpatient Sample data set, TAVI is an economically satisfactory alternative to SAVR and results in an approximately 2-day shorter length of stay during the index hospitalization.
Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis/economics , Hospital Costs/statistics & numerical data , Models, Statistical , Registries , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/economics , Female , Humans , Length of Stay/economics , Length of Stay/trends , Male , Propensity Score , Retrospective Studies , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/economics , United StatesABSTRACT
Although the benefit of percutaneous coronary interventions (PCIs) for patients presenting with acute coronary syndromes (ACS) has been established in numerous studies, the role of PCI in stable coronary artery disease (CAD) remains controversial. With the publication of the Clinical Outcomes Utilizing Revascularization and Aggressive Drug Evaluations trial and the appropriate use criteria for coronary artery revascularization, we sought to examine the impact of these treatment strategies and guidelines on the current practice of PCI in United States. We conducted a serial cross-sectional study with time trends of patients undergoing PCI for ACS and stable CAD from 2007 to 2011. The annual rate of all PCI decreased by 27.7% from 10,785 procedures per million adults per year in 2007 to 2008 to 7,801 procedures per million adults per year in 2010 to 2011 (p=0.03). Although there was no statistically significant decrease in the PCI utilization for ACS from 2007 to 2011, PCI utilization for stable CAD decreased by 51.7% (from 2,056 procedures per million adults per year in 2008 to 992 procedures per million adults per year in 2011, p=0.02). Hospitals with a higher volume of PCI experienced a more significant decrease. Decrease in PCI utilization for stable CAD was statistically significant for patients with Medicare and private insurance/health maintenance organization (44.5%, p=0.03 and 59.5%, p=0.007, respectively). In conclusion, the rate of PCI decreased substantially starting from 2009 in the United States. Most of the decrease was attributed to the reduction in PCI utilization for stable CAD.