Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 69
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Am Heart J ; 190: 86-93, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28760217

ABSTRACT

BACKGROUND: Combination of oral anticoagulation (OAC) and antiplatelets is used in atrial fibrillation (AF) patients undergoing percutaneous coronary intervention and stent (PCI-S) procedure but is associated with increased bleeding when triple antithrombotic therapy (TAT) is used. Our aim was to analyze the impact of time in therapeutic range (TTR) on outcomes, in patients prescribed with TAT. METHODS: Ancillary analysis from the AFCAS registry in patients assigned to TAT. TTR was calculated with Rosendaal method. Outcomes were analyzed according to TTR tertiles (T1 [≤56.8%] vs. T2 [56.9-93.8%] vs. T3 [≥93.9%]). Major bleeding was the primary outcome. RESULTS: Of 963 patients enrolled, 470(48.8%) were prescribed with TAT at discharge and qualified for this analysis. Median [IQR] TTR was 80.0% [45.3-100%]. After 359 [341-370] days, major bleeding rates were progressively lower with increasing TTR tertiles (T1 vs. T2 vs. T3: 10.3% vs. 4.7% vs. 2.3%, P=.006). Kaplan-Meier analysis demonstrated a progressively lower risk for major bleeding across tertiles (P=.006). Patients in the highest TTR tertile had a non-significant lower risk for major adverse coronary and cerebrovascular events (MACCE) (log-rank: 4.905, P=.086). Cox regression analysis showed that T2 and T3 were inversely associated with major bleeding (hazard ratio [HR]:0.39, P=.050 and HR: 0.21, P=.005). Continuous TTR was inversely associated with major bleeding (HR: 0.98, P<.001). For MACCE, adjusted Cox analysis found a non-significant lower risk for T3 (HR: 0.64, P=.128). CONCLUSIONS: In AF patients undergoing PCI-S prescribed TAT, good quality anticoagulation control (as reflected by TTR) was closely related to bleeding outcomes during follow-up. Despite some suggestive trends for an inverse relationship between TTR and MACCE, no definitive conclusions can be drawn, and further large studies are needed.


Subject(s)
Anticoagulants/therapeutic use , Atrial Fibrillation/complications , Coronary Artery Disease/surgery , Coronary Vessels/surgery , Percutaneous Coronary Intervention/methods , Registries , Thromboembolism/prevention & control , Coronary Artery Disease/complications , Europe/epidemiology , Female , Follow-Up Studies , Humans , Incidence , Male , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Prognosis , Prospective Studies , Stents , Survival Rate/trends , Thromboembolism/epidemiology , Thromboembolism/etiology , Time Factors
2.
J Interv Cardiol ; 30(2): 114-123, 2017 Apr.
Article in English | MEDLINE | ID: mdl-27925308

ABSTRACT

OBJECTIVES: We performed a post hoc analysis of outcome in patients with, versus those without, calcified target lesions from the BASE ACS trial. BACKGROUND: The outcome of contemporary stent implantation in patients with calcified lesions presenting with acute coronary syndrome is unknown. METHODS: The BASE ACS trial randomized 827 patients (1:1) presenting with acute coronary syndrome to receive either titanium-nitride-oxide-coated stents or everolimus-eluting stents. Calcified lesions were defined as moderate or severe calcification in the vessel wall by coronary angiography. The primary endpoint was major adverse cardiac events (MACE): a composite of cardiac death, non-fatal myocardial infarction or ischemia-driven target lesion revascularization. Follow-up was planned at 12 months, and yearly thereafter for up to 7 years. RESULTS: Of 827 patients enrolled in the trial, 352 (42.6%) had calcified target lesions. Median follow-up was 5.0 years. The incidence of MACE was higher in patients with, versus those without, calcified target lesions (19.6% vs. 12.2%, respectively, P = 0.004). This was driven by more frequent cardiac death and non-fatal myocardial infarction events (P < 0.05, both). The rates of ischemia-driven target lesion revascularization were comparable (P > 0.05). MACE and the other endpoints were comparable between the 2 propensity-score matched subgroups (P > 0.05 for all). Hypertension and smaller vessel size independently predicted MACE in patients treated for calcified lesions. CONCLUSIONS: Patients presenting with acute coronary syndrome who were treated for calcified lesions had worse long-term clinical outcome, compared with those treated for non-calcified lesions, mainly due to more frequent safety events. In the propensity score-matched analysis, the outcome was comparable.


Subject(s)
Acute Coronary Syndrome/surgery , Percutaneous Coronary Intervention , Stents , Vascular Calcification/surgery , Acute Coronary Syndrome/complications , Acute Coronary Syndrome/mortality , Aged , Coronary Angiography , Female , Follow-Up Studies , Humans , Male , Middle Aged , Myocardial Infarction/epidemiology , Propensity Score , Stents/adverse effects , Time Factors , Titanium , Treatment Outcome , Vascular Calcification/complications , Vascular Calcification/diagnostic imaging
3.
Scand Cardiovasc J ; 51(5): 248-254, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28666394

ABSTRACT

OBJECTIVES: We explored the predictors and outcome of poor, versus good, initial TIMI flow in patients with acute coronary syndrome (ACS). DESIGN: We performed post-hoc analysis of a randomized trial of patients presenting with ACS who received 2 comparative stents. Poor initial TIMI flow was defined as baseline TIMI flow grade 0/1 at the initial coronary angiography. The primary endpoint was major adverse cardiac events (MACE): a composite of cardiac death, non-fatal myocardial infarction or ischemia-driven target lesion revascularization. Stent thrombosis (ST) was adjudicated according to the criteria of definite ST described by the Academic Research Consortium. Propensity score-matched analysis was performed. We report data after 5-year follow-up. RESULTS: Of 827 patients enrolled, 279 (33.7%) had initial TIMI 0/1 flow. Median follow-up duration was 5.0 years. Presentation by ST-elevation myocardial infarction and target vessel other than left anterior descending artery predicted initial TIMI 0/1 flow. MACE rate was comparable between the 2 subgroups (14% versus 15.9%, in patients with poor versus good initial TIMI flow, respectively, p = .46). Individual endpoints were comparable (p > .05 for all). Definite ST was more frequent in patients with initial TIMI 0/1 flow (3.6% versus 1.5%, respectively, p = .048). This was driven by more frequent early events (30 days) (p = .036); late/very late events were comparable (p = 1.0). CONCLUSIONS: Predictors of poor initial TIMI flow included presentation by ST-elevation myocardial infarction, and target vessel other than left anterior descending artery. Definite ST occurred more in patients with poor, versus good, initial TIMI flow, mainly driven by difference in early events.


Subject(s)
Acute Coronary Syndrome/therapy , Coronary Circulation , Coronary Vessels/physiopathology , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction/therapy , Acute Coronary Syndrome/diagnostic imaging , Acute Coronary Syndrome/mortality , Acute Coronary Syndrome/physiopathology , Aged , Chi-Square Distribution , Coronary Angiography , Coronary Thrombosis/etiology , Coronary Vessels/diagnostic imaging , Drug-Eluting Stents , Female , Humans , Kaplan-Meier Estimate , Logistic Models , Male , Middle Aged , Multivariate Analysis , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Propensity Score , Prosthesis Design , Randomized Controlled Trials as Topic , Recurrence , Retrospective Studies , Risk Factors , ST Elevation Myocardial Infarction/diagnostic imaging , ST Elevation Myocardial Infarction/mortality , ST Elevation Myocardial Infarction/physiopathology , Time Factors , Treatment Outcome
4.
Catheter Cardiovasc Interv ; 87(4): E122-7, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26308878

ABSTRACT

OBJECTIVES: We explored the 12-month clinical outcome of the titanium-nitride-oxide-coated OPTIMAX stent based on cobalt-chromium platform. BACKGROUND: The OPTIMAX stent demonstrated a satisfactory 6-month clinical outcome in de novo coronary lesions. METHODS: We enrolled 224 consecutive symptomatic patients with significant (50%) stenosis in de novo coronary lesions, who were treated with OPTIMAX stent implantation. The primary endpoint was major adverse cardiac events at 12-month follow-up, defined as a composite of cardiac death, non-fatal myocardial infarction (MI), or ischemia-driven target lesion revascularization (TLR). Stent thrombosis was adjudicated according to the definition of the Academic Research Consortium. RESULTS: The mean age of the cohort was 67 ± 8 years (75% males). Patients presented with acute coronary syndrome in 62.1%. Radial access was used in 92%; complex (type B and C) lesions were treated in 79.9%. Both procedural and clinical success occurred in 100% of the cases. The mean follow-up period was 366 ± 22 days. At 12-month follow-up, the primary endpoint occurred in 14 (6.3%) patients. Cardiac death occurred in three (1.3%) patients, non-fatal MI in seven (3.1%) patients, and ischemia-driven TLR in seven (3.1%) patients. No definite stent thrombosis occurred. CONCLUSIONS: In the current prospective observational study, implantation of the OPTIMAX stent demonstrated an adequate 12-month clinical outcome, with a low rate of major adverse cardiac events, and no stent thrombosis.


Subject(s)
Chromium Alloys , Coated Materials, Biocompatible , Coronary Artery Disease/therapy , Coronary Stenosis/therapy , Oxides , Percutaneous Coronary Intervention/instrumentation , Stents , Titanium , Aged , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/mortality , Coronary Thrombosis/etiology , Coronary Thrombosis/mortality , Female , Humans , Male , Middle Aged , Myocardial Infarction/etiology , Myocardial Infarction/mortality , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prospective Studies , Prosthesis Design , Risk Factors , Time Factors , Treatment Outcome
5.
Scand Cardiovasc J ; 50(4): 218-23, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27102382

ABSTRACT

OBJECTIVES: The BASE-ACS trial demonstrated non-inferiority of titanium-nitride-oxide-coated bioactive stents (BAS), versus everolimus-eluting stents (EES), for major adverse cardiac events (MACE) at 1- and 2-year follow-up, in patients with acute coronary syndrome (ACS). We presented the 4-year outcome of the BASE-ACS trial. DESIGN: We randomized 827 patients with ACS to receive either BAS (417) or EES (410). MACE was a composite of cardiac death, non-fatal myocardial infarction (MI) or ischemia-driven target lesion revascularization (TLR) at 12-month follow-up. Analyses were performed by intention to treat. Follow-up was planned at 12 months, and yearly thereafter for 5 years. RESULTS: Four-year clinical follow-up was completed in 753 (91.1%) patients. At 4 years, BAS were non-inferior to EES for MACE (14.7% versus 17.8%, respectively; p = 0.24 for superiority; p = 0.001 for non-inferiority). Non-fatal MI was less frequent with BAS (5.0% versus 9.2%, respectively; p = 0.025). Cardiac death and ischemia-driven TLR were comparable (2.9% versus 3.5%, and 8.6% versus 9.2%; p = 0.62 and p = 0.80, respectively). Independent predictors of MACE were calcified lesions (HR 1.54, p = 0.021), the number of vessels treated (HR 1.53, p = 0.025), and reference vessel diameter (HR 0.54, p = 0.006). CONCLUSIONS: In patients presenting with ACS, BAS was associated with a clinical outcome non-inferior to EES at 4-year follow-up.


Subject(s)
Acute Coronary Syndrome , Coronary Restenosis , Everolimus/therapeutic use , Percutaneous Coronary Intervention , Titanium/therapeutic use , Acute Coronary Syndrome/diagnosis , Acute Coronary Syndrome/therapy , Aged , Antineoplastic Agents/therapeutic use , Coronary Angiography/methods , Coronary Restenosis/diagnosis , Coronary Restenosis/etiology , Coronary Restenosis/prevention & control , Drug-Eluting Stents , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Prosthesis Design , Treatment Outcome
6.
J Electrocardiol ; 49(4): 554-6, 2016.
Article in English | MEDLINE | ID: mdl-27323664

ABSTRACT

An 83-year-old lady had a DDDR pacemaker inserted in 1997 for symptomatic atrioventricular block. She underwent battery replacement in 2008. In 2010, she developed atrial fibrillation; the pacemaker was switched to VVIR mode. During the last 2years, ventricular lead threshold increased progressively. In December 2015, she presented for elective battery replacement. After successful battery replacement, the ventricular lead threshold remained high; therefore, we implanted a leadless transcatheter pacemaker, via femoral vein access, using a dedicated catheter delivery system. Electrical measurements at this stage revealed a pacing threshold of 0.28V at 0.24msec, and an impedance of 650Ω.


Subject(s)
Atrial Fibrillation/prevention & control , Atrioventricular Block/prevention & control , Cardiac Catheterization/methods , Pacemaker, Artificial , Prosthesis Implantation/methods , Adult , Atrial Fibrillation/complications , Atrioventricular Block/complications , Cardiac Catheterization/instrumentation , Combined Modality Therapy/instrumentation , Combined Modality Therapy/methods , Electrodes, Implanted , Female , Humans , Prosthesis Failure , Prosthesis Implantation/instrumentation , Treatment Outcome
7.
Circ J ; 79(2): 360-7, 2015.
Article in English | MEDLINE | ID: mdl-25502167

ABSTRACT

BACKGROUND: Patients at high bleeding risk would benefit from a shorter dual antiplatelet therapy after PCI. Compared to first-generation devices, the design of newer generation drug-eluting stents may facilitate more rapid anatomical and functional healing of stented vessel based on thinner stent platforms, biodegradable/biocompatible polymers and rapid drug elution. METHODS AND RESULTS: Forty-four non-diabetic patients with acute coronary syndrome (ACS) and culprit lesion in the LAD were randomized to receive either biodegradable polymer sirolimus-eluting stent (BP-SES) or durable polymer zotarolimus-eluting stent (DP-ZES). Neointimal strut coverage was examined using optical coherence tomography, and vasodilator response on invasive thermodilution-derived coronary flow reserve (CFR) at 3-month follow-up. The primary endpoints were percent uncovered struts and CFR. A total of 425 cross-sections (4,897 struts) were analyzed in the BP-SES group, and 425 cross-sections (5,467 struts) in the DP-ZES group. The percent uncovered struts was lower in the BP-SES group compared with the DP-ZES group, both at strut level (3.9% vs. 8.9%, respectively, P<0.001), and stent level (3.9 ± 3.2% vs. 8.9 ± 6.9%, respectively, P=0.019). No significant difference was found between the 2 groups regarding CFR (3.0 ± 1.3 vs. 3.2 ± 1.0, respectively, P>0.05). CONCLUSIONS: In non-diabetic patients with ACS, BP-SES provided slightly better stent strut coverage at 3 months compared with DP-ZES, but neither stent was fully covered. No difference in vasodilator response was seen.


Subject(s)
Absorbable Implants , Acute Coronary Syndrome , Biodegradable Plastics , Drug-Eluting Stents , Neointima , Sirolimus/analogs & derivatives , Vasodilation/drug effects , Acute Coronary Syndrome/physiopathology , Acute Coronary Syndrome/surgery , Aged , Double-Blind Method , Female , Humans , Male , Middle Aged , Prospective Studies
8.
Scand Cardiovasc J ; 49(5): 280-5, 2015.
Article in English | MEDLINE | ID: mdl-26156030

ABSTRACT

OBJECTIVES: In a prospective study, we explored the extent of neointimal coverage of stent struts by optical coherence tomography 14 days following the implantation of bioactive stents in an unselected cohort. DESIGN: We enrolled 15 consecutive patients who underwent bioactive stent implantation. Optical coherence tomography images were obtained at 14-day follow-up. Morphometric analysis, strut coverage, strut apposition, neointimal hyperplasia, and possible thrombosis were evaluated at 1-mm intervals. Binary stent strut coverage was defined as the percentage of covered struts of all analyzed struts. RESULTS: Patients underwent optical coherence tomography examination at an average of 14.5 ± 2.3 days following stent implantation. Mean age was 62 ± 11 years; 86.7% were males; 26.7% diabetic. Three-hundred eighteen cross-sections were analyzed, including 2935 struts, an average of 9.2 ± 3 struts per cross-section. Binary stent strut coverage was 96.3%; the prevalence of malapposed struts 1.8%. No thrombi were detected. Mean neointimal hyperplasia thickness was 71.5 ± 53.7 µm. CONCLUSIONS: In the current evaluation by optical coherence tomography at 14-day follow-up after bioactive stent implantation in an unselected cohort, binary stent strut coverage was fairly adequate, and the prevalence of malapposed struts was low.


Subject(s)
Neointima , Stents , Aged , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention , Prospective Studies , Tomography, Optical Coherence
9.
Circulation ; 127(11): 1219-28, e1-6, 2013 Mar 19.
Article in English | MEDLINE | ID: mdl-23418311

ABSTRACT

BACKGROUND: Infectious agents, especially bacteria and their components originating from the oral cavity or respiratory tract, have been suggested to contribute to inflammation in the coronary plaque, leading to rupture and the subsequent development of coronary thrombus. We aimed to measure bacterial DNA in thrombus aspirates of patients with ST-segment-elevation myocardial infarction and to check for a possible association between bacteria findings and oral pathology in the same cohort. METHODS AND RESULTS: Thrombus aspirates and arterial blood from patients with ST-segment-elevation myocardial infarction undergoing primary percutaneous coronary intervention (n=101; 76% male; mean age, 63.3 years) were analyzed with real-time quantitative polymerase chain reaction with specific primers and probes to detect bacterial DNA from several oral species and Chlamydia pneumoniae. The median value for the total amount of bacterial DNA in thrombi was 16 times higher than that found in their blood samples. Bacterial DNA typical for endodontic infection, mainly oral viridans streptococci, was measured in 78.2% of thrombi, and periodontal pathogens were measured in 34.7%. Bacteria-like structures were detected by transmission electron microscopy in all 9 thrombus samples analyzed; whole bacteria were detected in 3 of 9 cases. Monocyte/macrophage markers for bacteria recognition (CD14) and inflammation (CD68) were detected in thrombi (8 of 8) by immunohistochemistry. Among the subgroup of 30 patients with myocardial infarction examined by panoramic tomography, a significant association between the presence of periapical abscesses and oral viridans streptococci DNA-positive thrombi was found (odds ratio, 13.2; 95% confidence interval, 2.11-82.5; P=0.004). CONCLUSIONS: Dental infection and oral bacteria, especially viridans streptococci, may be associated with the development of acute coronary thrombosis.


Subject(s)
Mouth Diseases/complications , Myocardial Infarction/etiology , Stomatognathic Diseases/complications , Thrombosis/microbiology , Thrombosis/pathology , Viridans Streptococci/isolation & purification , Antigens, CD/metabolism , Antigens, Differentiation, Myelomonocytic/metabolism , Biomarkers/metabolism , Biopsy, Needle , DNA, Bacterial/metabolism , Female , Humans , Lipopolysaccharide Receptors/metabolism , Macrophages/metabolism , Male , Middle Aged , Mouth Diseases/microbiology , Retrospective Studies , Stomatognathic Diseases/microbiology , Thrombosis/complications , Viridans Streptococci/genetics
10.
Catheter Cardiovasc Interv ; 82(7): E864-70, 2013 Dec 01.
Article in English | MEDLINE | ID: mdl-23765437

ABSTRACT

Current recommendations on the management of patients with atrial fibrillation (AF) undergoing percutaneous coronary intervention with stent (PCI-S) essentially derive from small, single-center, retrospective datasets. To obtain larger and better quality data, we carried out the prospective, multicenter Atrial Fibrillation undergoing Coronary Artery Stenting (AFCAS) study. Therefore, consecutive patients with history of or ongoing AF undergoing PCI-S were enrolled, and occurrence of adverse ischemic and bleeding events recorded during 12 months follow-up. In this article, we report the in-hospital observations. Out of the 963 patients, in the majority of cases (49.1%) AF was permanent. The associated risk of stroke, as defined by a CHADS2 -score ≥2, was in 70% of patients moderate to high. Upon enrollment in the registry, 69.3% of patients were on VKA therapy. Overall occurrence of in-hospital major adverse cardiac events was 4.5% (cardiovascular death 1.9%, urgent revascularization in 1.5%, and stroke/arterial thromboembolism in 0.6%). Bleeding complications occurred in 7.1% of patients, being severe in 2.5%. In a logistic regression analysis, no risk factor was independently associated with bleeding events, whereas Clopidogrel treatment decreased and female gender/treatment with gpIIb/IIIa-antagonists, respectively increased the risk for the combined ischemic endpoint. The majority of AF patients undergoing PCI-S are at high stroke risk, and therefore VKA treatment should not be withdrawn and combined anticoagulant and antiplatelet treatment is warranted. Current management appears largely in accordance with current recommendations, whereby accounting for the limited occurrence of in-hospital adverse ischemic and bleeding events.


Subject(s)
Anticoagulants/therapeutic use , Atrial Fibrillation/drug therapy , Coronary Artery Disease/therapy , Percutaneous Coronary Intervention/instrumentation , Stents , Aged , Aged, 80 and over , Anticoagulants/adverse effects , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/mortality , Chi-Square Distribution , Coronary Artery Disease/complications , Coronary Artery Disease/diagnosis , Coronary Artery Disease/mortality , Europe , Female , Guideline Adherence , Hemorrhage/chemically induced , Hospital Mortality , Humans , Logistic Models , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Platelet Aggregation Inhibitors/therapeutic use , Practice Guidelines as Topic , Prospective Studies , Registries , Risk Factors , Sex Factors , Stroke/etiology , Stroke/prevention & control , Thromboembolism/etiology , Thromboembolism/prevention & control , Time Factors , Treatment Outcome
11.
Rev Esp Cardiol (Engl Ed) ; 76(3): 150-156, 2023 Mar.
Article in English, Spanish | MEDLINE | ID: mdl-35752571

ABSTRACT

INTRODUCTION AND OBJECTIVES: To evaluate by optical coherence tomography neointimal healing response after implantation of cobalt-chromium-based titanium-nitride-oxide-coated (TiNO) stents and platinum-chromium-based biodegradable-polymer-coated everolimus-eluting stents (EES) in patients with acute coronary syndrome. METHODS: Patients were randomized (1:1) to receive either a TiNO-stent or EES. Optical coherence tomography images were obtained at 30-day (cohort A, n = 52) and 6-month (cohort B, n = 30) follow-up. The primary endpoint was the percentage of uncovered struts per patient. RESULTS: In cohort A, the percentage of uncovered struts was lower with TiNO-stents vs EES (3.2% vs 19.6%, P <.001). The percentage of malapposed struts was 0.4% in the TiNO-group and 2.1% in the EES group (P <.001). In cohort B, the percentage of uncovered struts was also lower with TiNO-stents (0.0% vs 8.7%, (P <.001). The percentage of malapposed struts was 0% in the TiNO-stent group and 0.3% in the EES group, (P=.008). None of the patients had repeat revascularization during the 6 months of follow-up. CONCLUSIONS: Following percutaneous intervention for acute coronary syndrome, TiNO stent implantation was associated with a lower percentage of uncovered and malapposed struts per patient, compared with EES, at early and mid-term follow-up. This study is registered under ClinicalTrials.gov, with number NCT02464397.


Subject(s)
Acute Coronary Syndrome , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Everolimus , Sirolimus , Nitric Oxide , Titanium , Treatment Outcome , Coronary Vessels , Chromium , Tomography, Optical Coherence/methods
12.
J Clin Med ; 12(21)2023 Nov 06.
Article in English | MEDLINE | ID: mdl-37959416

ABSTRACT

(1) Background: Percutaneous coronary interventions (PCI) in patients with acute coronary syndrome (ACS) are performed with titanium-nitride-oxide-coated stents (TiNOSs) or drug-eluting stents (DESs). The initial completion of this prospective systematic literature review (SLR) of prospective randomized controlled trials (RCTs) showed that TiNOSs are non-inferior to DESs in major adverse cardiac event (MACE) rates and present a lower risk of recurrent myocardial infarction (MI) at 1-year follow-up. This iteration of the SLR protocol performs the critical assessment of 5-year follow-up outcomes with clinical validity and generalizability assessments. (2) Methods: The previously described SLR and meta-analysis protocol, per PRISMA, Cochrane methods, and GRADE, was applied to 5-year follow-up outcomes. (3) Results: Three RCTs were eligible, comprising 1620 patients with TiNOS vs. 1123 with DES. The pooled risk ratios (RRs) and 95% confidence intervals were MACE 0.82 [0.68, 0.99], MI 0.58 [0.44, 0.78], cardiac death (CD) 0.46 [0.28, 0.76], ischemia-driven target lesion revascularization (TLR) 1.03 [0.79, 1.33], probable or definite stent thrombosis (ST) 0.32 [0.21, 0.59], and all-cause mortality (TD) 0.84 [0.63, 1.12]. The evidence certainty was high in MACE, CD, MI, and ST, and moderate in TLR and TD. (4) Conclusions: TiNOSs in ACS at 5-year follow-up appear safer than DESs and equally efficacious. The pooled RRs stratified by clinical presentation and stent type will be required to test this meta-analysis's clinical validity and generalize its results to patient populations with varying proportions of clinical presentations and DES options.

13.
JAMA Cardiol ; 8(7): 703-708, 2023 07 01.
Article in English | MEDLINE | ID: mdl-37203243

ABSTRACT

Importance: Titanium-nitride-oxide (TiNO)-coated stents show faster strut coverage compared with drug-eluting stents without excessive intimal-hyperplasia observed in bare metal stents. It is important to study long-term clinical outcomes after treatment of patients with an acute coronary syndrome (ACS) by TiNO-coated stents, which are neither drug-eluting stents nor bare metal stents. Objective: To compare the rate of main composite outcome of cardiac death, myocardial infarction (MI), or ischemia-driven target lesion revascularization at 5 years in patients with ACS randomized to receive either a TiNO-coated stent or a third-generation everolimus-eluting stent (EES). Design, Setting, and Participants: This multicenter, randomized, controlled, open-label trial was conducted in 12 clinical sites in 5 European countries and enrolled patients from January 2014 to August 2016. Patients presenting with ACS (ST-segment elevation MI, non-ST-segment elevation MI, and unstable angina) with at least 1 de novo lesion were randomized to receive either a TiNO-coated stent or an EES. The present report analyzes the long-term follow-up for the main composite outcome and its individual components. Analysis took place between November 2022 to March 2023. Main outcome: The primary end point was a composite of cardiac death, MI, or target lesion revascularization at 12-month follow-up. Results: A total of 1491 patients with ACS were randomly assigned to receive either TiNO-coated stents (989 [66.3%]) or EES (502 [33.7%]). The mean (SD) age was 62.7 (10.8) years, and 363 (24.3%) were female. At 5 years, the main composite outcome events occurred in 111 patients (11.2%) in the TiNO group vs 60 patients (12%) in the EES group (hazard ratio [HR], 0.94; 95% CI, 0.69-1.28; P = .69). The rate of cardiac death was 0.9% (9 of 989) vs 3.0% (15 of 502) (HR, 0.30; 95% CI, 0.13-0.69; P = .005), the rate of MI was 4.6% (45 of 989) vs 7.0% (35 of 502) (HR, 0.64; 95% CI, 0.41-0.99; P = .049), the rate of stent thrombosis was 1.2% (12 of 989) vs 2.8% (14 of 502) (HR, 0.43; 95% CI, 0.20-0.93; P = .034), and the rate of target lesion revascularization was 7.4% (73 of 989) vs 6.4% (32 of 502) (HR, 1.16; 95% CI, 0.77-1.76; P = .47) in the TiNO-coated stent arm and in the EES arm, respectively. Conclusion and relevance: In this study, patients with ACS had a main composite outcome that was not different 5 years after TiNO-coated stent or EES. Trial Registration: ClinicalTrials.gov Identifier: NCT02049229.


Subject(s)
Acute Coronary Syndrome , Drug-Eluting Stents , Myocardial Infarction , Percutaneous Coronary Intervention , Humans , Female , Middle Aged , Male , Everolimus/pharmacology , Everolimus/therapeutic use , Acute Coronary Syndrome/surgery , Acute Coronary Syndrome/drug therapy , Treatment Outcome , Percutaneous Coronary Intervention/adverse effects , Stents , Myocardial Infarction/epidemiology , Myocardial Infarction/etiology , Death
14.
Circ J ; 76(6): 1363-8, 2012.
Article in English | MEDLINE | ID: mdl-22447005

ABSTRACT

BACKGROUND: The anti-thrombotic strategy during coronary stenting is challenging in patients on long-term oral anticoagulation (OAC) because of atrial fibrillation (AF). Uninterrupted OAC (UAC) is increasingly used, but bridging therapy (BT) is still in common use. METHODS AND RESULTS: Management of patients with Atrial Fibrillation undergoing Coronary Artery Stenting (AFCAS) is a prospective multicenter European registry that recruited 963 patients with AF undergoing coronary stenting. To compare the safety of UAC and BT, bleeding complications and major adverse cardiac and cerebrovascular events (MACCE; death, myocardial infarction, target vessel revascularization, stent thrombosis and stroke) were assessed in 290 patients treated with UAC and 161 patients with BT during a 30-day follow-up period. In the BT group, OAC was interrupted for a median of 5 days. Overall bleeding complications tended to be more common in the BT group (18.6% vs. 12.1%, P=0.07), with no significant difference in the rate of major bleeding (2.5% vs. 1.4%) or MACCE (6.2% vs. 3.8%). After adjustment for propensity score, BT was not associated with bleeding complications (odds ratio [OR], 1.38; 95% confidence interval [CI]: 0.77-2.48, P=0.28) or MACCE (OR, 1.16; 95%CI: 0.44-3.05, P=0.76). Periprocedural international normalized ratio was not associated with bleeding or MACCE. CONCLUSIONS: UAC does not increase perioperative complications during coronary stenting and is a simple and cost-effective alternative to conventional heparin bridging.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Anticoagulants/administration & dosage , Atrial Fibrillation/drug therapy , Coronary Artery Disease/therapy , Heparin/administration & dosage , Stents , Administration, Oral , Aged , Aged, 80 and over , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/mortality , Anticoagulants/adverse effects , Atrial Fibrillation/complications , Atrial Fibrillation/mortality , Coronary Artery Disease/complications , Coronary Artery Disease/mortality , Coronary Thrombosis/etiology , Drug Administration Schedule , Drug Substitution , Europe , Female , Hemorrhage/chemically induced , Heparin/adverse effects , Humans , Logistic Models , Male , Myocardial Infarction/etiology , Odds Ratio , Propensity Score , Prospective Studies , Registries , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
15.
Biomedicines ; 10(12)2022 Dec 07.
Article in English | MEDLINE | ID: mdl-36551915

ABSTRACT

(1) Background: Practice guidelines define drug-eluting stents (DES) as the standard of care in coronary percutaneous coronary intervention (PCI), including in acute coronary syndrome (ACS). This is based on comparisons with bare-metal stents (BMS). However, non-drug-eluting titanium-nitride-oxide-coated stents (TiNOS) have not been taken into account. The objective of this study is to determine whether TiNOS can be used as an alternative to DES in ACS. (2) Methods: A prospective systematic literature review (SLR), conducted according to the PRISMA guidelines, was performed, wherein multiple literature databases from 2018 and 2022 were searched. Prospective, randomised, controlled trials comparing outcomes after PCI with TiNOS vs. DES in any coronary artery disease (CAD) were searched. Clinical outcomes were meta-analytic pooled risk ratios (RR) of device-oriented Major Adverse Cardiac Events (MACE) and their components. The analysis stratified outcomes reported with ACS-only vs. ACS jointly with chronic coronary syndrome (CCS). (3) Results: Five RCTs were eligible, comprising 1855 patients with TiNOS vs. 1363 with DES at a 1-year follow-up. Three enrolled patients presented with ACS only and two with ACS or CCS. The latter accounted for most of the patients. The one-year pooled RRs in those three RCTs were as follows: MACE 0.93 [0.72, 1.20], recurrent myocardial infarction (MI) 0.48 [0.31, 0.73], cardiac death (CD) 0.66 [0.33, 1.31], clinically driven target lesion revascularization (TLR) 1.55 [1.10, 2.19], and stent thrombosis (ST) 0.35 [0.20, 0.64]. Those results were robust to a sensitivity analysis. The evidence certainty was high in MACE and moderate or low in the other endpoints. (4) Conclusions: TiNOS are a non-inferior and safe alternative to DES in patients with ACS.

16.
J Interv Cardiol ; 24(1): 1-8, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21039884

ABSTRACT

AIMS: We sought to present the 5-year clinical outcome of the titanium-nitride-oxide-coated bioactive stents (BAS), as compared to paclitaxel-eluting stents (PES), in a real-world patient population. METHODS: From May 2003 to November 2004, we enrolled 405 consecutive patients who underwent percutaneous coronary intervention with either BAS or PES implantation. Patients were prospectively followed up for 5 years. The primary end-point was major adverse cardiac events (MACE) at 5-year follow-up including cardiac death, nonfatal myocardial infarction (MI), or target lesion revascularization. RESULTS: A total of 201 patients received BAS (218 lesions/221 stents) while 204 patients received PES (244 lesions/247 stents). Clinical follow-up for 5 years was completed in all patients. Cumulative MACE at the end of 5-year follow-up occurred in 34 (16.9%) patients in the BAS group, as compared to 53 (26%) in the PES group (OR 1.7, 95% CI 1.1-2.8, P = 0.03). This difference was mainly driven by a lower incidence of MI in the BAS group as compared with the PES group (9.5% vs. 20.6%, OR 2.5, 95% CI 1.4-4.4, P = 0.002). Stent thrombosis occurred in 16 (7.8%) patients in the PES group, while no one suffered stent thrombosis in the BAS group. CONCLUSION: BAS implantation in a real-world patient population achieves an excellent clinical outcome over 5-year follow-up, with a significantly lower incidence of MI, MACE, and stent thrombosis as compared to PES.


Subject(s)
Angioplasty, Balloon, Coronary/statistics & numerical data , Antineoplastic Agents, Phytogenic/therapeutic use , Coronary Artery Disease/therapy , Drug-Eluting Stents , Paclitaxel/therapeutic use , Titanium/chemistry , Aged , Confidence Intervals , Coronary Artery Disease/mortality , Coronary Artery Disease/prevention & control , Coronary Restenosis/mortality , Coronary Restenosis/prevention & control , Coronary Restenosis/therapy , Female , Finland , Humans , Male , Middle Aged , Odds Ratio , Propensity Score , Prospective Studies , Registries , Time Factors , Treatment Outcome
17.
JACC Cardiovasc Interv ; 13(14): 1697-1705, 2020 07 27.
Article in English | MEDLINE | ID: mdl-32703593

ABSTRACT

OBJECTIVES: This study sought to compare next-generation cobalt-chromium-based titanium-nitride-oxide (TiNO)-coated stents with a platinum-chromium-based biodegradable polymer everolimus-eluting stent (EES) in patients with acute coronary syndrome (ACS). BACKGROUND: Previous generation TiNO-coated stents showed acceptable performance in patients with ACS. METHODS: In a multicenter, randomized trial, we randomly assigned 1,491 ACS patients (2:1) to receive either a TiNO-coated stent (n = 989) or EES (n = 502). The primary endpoint was the rate of a composite of cardiac death, myocardial infarction (MI), or ischemia-driven target lesion revascularization at 12-month follow-up. The co-primary endpoint was a composite of cardiac death, MI, or major bleeding at 18 months. RESULTS: A primary endpoint event occurred in 6.3% of patients in the TiNO-coated stent group versus in 7.0% in the EES group (hazard ratio: 0.93; 95% confidence interval: 0.71 to 1.22; p = 0.66 for superiority; p < 0.001 for noninferiority). A co-primary endpoint event occurred in 3.7% of the patients in the TiNO group and in 7.8% in the EES group (hazard ratio: 0.64; 95% confidence interval: 0.51 to 0.80; p = 0.001). TiNO-coated stents were associated with lower rates of cardiac death (0.6% vs. 2.6%; p = 0.002) and MI (2.2% vs. 5.0%; p = 0.007) at 18 months of follow-up. Rates of target lesion revascularization were not significantly different at 18 months (5.8% vs. 4.4%; p = 0.27). CONCLUSIONS: In patients with ACS, cobalt-chromium-based TiNO-coated stents were noninferior to platinum-chromium-based biodegradable polymer EES for major cardiac events at 12 months, and were superior for the co-primary endpoint of cardiac death, MI, and bleeding at 18 months. (Comparison of Titanium-Nitride-Oxide-Coated Bio-Active-Stent (Optimax™) to the Drug (Everolimus) -Eluting Stent (Synergy™) in Acute Coronary Syndrome [TIDES-ACS]; NCT02049229).


Subject(s)
Acute Coronary Syndrome/therapy , Cardiovascular Agents/administration & dosage , Drug-Eluting Stents , Everolimus/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Titanium , Acute Coronary Syndrome/diagnostic imaging , Acute Coronary Syndrome/mortality , Aged , Cardiovascular Agents/adverse effects , Europe , Everolimus/adverse effects , Female , Hemorrhage/etiology , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Time Factors , Treatment Outcome
19.
Cardiovasc Revasc Med ; 20(12): 1140-1145, 2019 Dec.
Article in English | MEDLINE | ID: mdl-30833209

ABSTRACT

BACKGROUND: The Magmaris bioresorbable magnesium scaffold was successfully tested in in-vitro and in clinical premarket studies. Subsequently the Magmaris postmarket program aimed to review intraprocedural data of at least 2000 patients to assess user preferences, guideline adherence and intraprocedural performance in clinical routine. METHODS: This international multicentre survey encompasses data from 356 hospitals across 45 countries. As part of the certification for Magmaris implantation, each hospital had to complete consecutive post-market evaluation forms of their first 10 commercial Magmaris patients. RESULTS: From June 2016 to May 2018, data on 2018 implantations were collected. Main reasons for selecting Magmaris was patients' life expectancy (67%, n = 1359) and low or not calcified lesions, (67%, n = 1357). Magmaris was successfully deployed in 99% of cases (n = 1995), predilatation was performed in 95% (n = 1922) and post-dilatation in 87% (n = 1756). Physicians rated the overall performance and the pushability as good or very good in 96% of cases (n = 1799). Guide wire friction, trackability, and conformability were rated as good or very good in 94% of cases, and crossability in 93%. The majority of patients were scheduled to receive dual antiplatelet therapy for up to 12 months. CONCLUSION: Generally, implantation guidelines were adhered to and theoretical advantages of the metal scaffold observed in in-vitro tests have translated into practice with good intraprocedural performance outcomes, confirming the controlled roll-out of this novel technology into clinical practice. SUMMARY FOR ANNOTATED TABLE OF CONTENT: The Magmaris 2000 program includes the first commercial cases at each hospital. Overall, data on 2018 implantations were collected. The high rate of pre- and post-dilatation as well as other parameters confirm that generally the implantation guidelines are adhered to and the good intraprocedural performance (rated as good or very good in 96%) confirm the theoretical advantages of a metallic scaffold in practice.


Subject(s)
Absorbable Implants/standards , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/standards , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible/standards , Coronary Artery Disease/therapy , Guideline Adherence/standards , Magnesium , Practice Guidelines as Topic/standards , Practice Patterns, Physicians'/standards , Sirolimus/administration & dosage , Angioplasty, Balloon, Coronary/adverse effects , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Humans , Life Expectancy , Platelet Aggregation Inhibitors/administration & dosage , Product Surveillance, Postmarketing , Prosthesis Design/standards , Sirolimus/adverse effects , Time Factors , Treatment Outcome
20.
Am J Cardiol ; 102(4): 386-90, 2008 Aug 15.
Article in English | MEDLINE | ID: mdl-18678292

ABSTRACT

Long-term warfarin therapy is assumed to increase bleeding and access site complications after coronary angiography and it is often recommended to postpone invasive procedures to reach international normalized ratio (INR) levels <1.8. To assess the safety and feasibility of diagnostic coronary angiography during uninterrupted warfarin therapy, we retrospectively analyzed all consecutive patients (n = 258) on warfarin therapy referred for diagnostic coronary angiography in 2 centers with long experience in uninterrupted warfarin therapy during coronary angiography and in 1 center with a policy of preprocedural warfarin pause. An age- and gender-matched control group (n = 258) with similar disease presentation (unstable or stable symptoms) was collected from each center. Radial access was used in 56% of patients in the warfarin group and in 60% of controls (p = 0.21). There was no difference in access site and bleeding complications (1.9% vs 1.6%) or major adverse cardiovascular and cerebrovascular events (0.4% vs 0.8%) between the warfarin group and their controls. Warfarin was interrupted in 80 patients (31%), and bridging therapy was used in 24 of these patients (30%). INR levels were higher in the uninterrupted warfarin group (2.3 vs 1.9, p <0.001), but the incidence of access site complications was not higher (1.7%) than in patients (n = 80) with a warfarin pause (2.5%) or in patients with pause and bridging therapy (8.3%). Need for blood transfusions (n = 2) occurred only in patients with bridging therapy. Access site complications were more common in the 22 patients with supratherapeutic anticoagulation (INR >3) than in patients with therapeutic periprocedural INR (9.1% vs 1.5%, p <0.05). In conclusion, a simple strategy of performing coronary angiography during uninterrupted therapeutic warfarin anticoagulation is a tempting alternative to bridging therapy and is likely to lead to considerable cost savings.


Subject(s)
Anticoagulants/administration & dosage , Anticoagulants/adverse effects , Coronary Angiography/adverse effects , Coronary Artery Disease/diagnostic imaging , Warfarin/administration & dosage , Warfarin/adverse effects , Aged , Case-Control Studies , Feasibility Studies , Female , Humans , International Normalized Ratio , Male , Retrospective Studies , Risk Factors , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL