Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 425
Filter
Add more filters

Publication year range
1.
Pharm Res ; 41(5): 1007-1020, 2024 May.
Article in English | MEDLINE | ID: mdl-38561579

ABSTRACT

PURPOSE: Products formulated for intramammary (IMM) infusion are intended for the delivery of therapeutic moieties directly into the udder through the teat canal to maximize drug exposure at the targeted clinical site, the mammary gland, with little to no systemic drug exposure. Currently, to our knowledge, there has been no in-vitro matrix system available to differentiate between IMM formulations. Our goal is to develop A custom tailored in-vitro "Matrix of Chemistry, Manufacturing and Control" (MoCMC) System to be a promising future tool for identifying inequivalent IMM formulations. MoCMC can detect inter and intra batch variabilities, thereby identifying potential generics versus brand product similarities or differences with a single numeric value and a specific & distinctive fingerprint. METHODS: The FDA-approved IMM formulation, SPECTRAMASTⓇ LC, was selected as the reference product for the MoCMC. Twelve in-house test formulations containing ceftiofur hydrochloride were formulated and characterized. The MoCMC was developed to include six input parameters and three output parameters. The MoCMC system was used to evaluate and compare SPECTRAMASTⓇ LC with its in-house formulations. RESULTS: Based on the MoCMC generated parameters, the distinctive fingerprints of MoCMC for each IMM formulations, and the statistical analyses of MCI and PPI values, in-house formulations, F-01 and F-02 showed consistency while the rest of in-house formulations (F-03-F-12) were significantly different as compared to SPECTRAMASTⓇ LC. CONCLUSION: This research showed that the MoCMC approach can be used as a tool for intra batch variabilities, generics versus brand products comparisons, post-approval formulations changes, manufacturing changes, and formulation variabilities.


Subject(s)
Chemistry, Pharmaceutical , Animals , Chemistry, Pharmaceutical/methods , Drug Compounding/methods , Female , Mammary Glands, Animal/metabolism , Anti-Bacterial Agents/analysis , Anti-Bacterial Agents/administration & dosage , Drugs, Generic
2.
Pharm Res ; 41(1): 129-139, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37783927

ABSTRACT

PURPOSE: Intramammary (IMM) formulations are locally acting and delivered intracisternally into the udder. No pharmacopeial in-vitro release method is available to differentiate between the IMM formulations. Our research aim is to develop in-vitro release methods that discriminate different IMM formulations (SPECTRAMAST® LC and in-house formulations). METHODOLOGY: Different in-house formulations were developed to simulate SPECTRAMAST® LC generics. SPECTRAMAST® LC and the in-house formulations were characterized for physicochemical attributes, such as particle size, rheology, drug content, sedimentation rate, and flocculation rate. The in-vitro release method was optimized by evaluating drug release using USP apparatuses 1, 2 (with and without enhancer/customized cells), and 4. Various test parameters, including medium effect (whole homogenized bovine milk versus aqueous buffer), medium volume (200-900 mL), and rotational speed (50-200 rpm) were investigated. RESULTS: Two potential in-vitro systems can be used as discriminatory methods for IMM formulations: USP apparatus 2 with the IMM formulation loaded into two containers a) customized formulation container (83.1 cm in height and 56.4 cm in width) or b) enhancer cells with their top adapted with mesh #40 (rotation speed:125 rpm and 900 mL of whole homogenized bovine milk). The release profile of SPECTRAMAST® LC at 1 h (99.8%) was not significantly different from formulations with similar physicochemical characteristics F-01 (99.1%) and F-02 (100.5%). Formulation with different physicochemical characteristics F-03 (44.3%) and F-04 (57.2%) showed slower release (1 h) than SPECTRAMAST® LC (98.8%). CONCLUSION: The developed in-vitro release methods can be used as a potential tool for in-vitro comparability evaluations for IMM formulations.


Subject(s)
Chemistry, Pharmaceutical , Water , Animals , Chemistry, Pharmaceutical/methods , Drug Liberation
3.
J Oncol Pharm Pract ; : 10781552241246119, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38656201

ABSTRACT

INTRODUCTION: The incidence of invasive fungal diseases (IFDs) has risen in hematologic malignancy patients due to neutropenia. While posaconazole is recommended as the first-line antifungal prophylaxis in acute myeloid leukemia (AML) and myelodysplastic syndrome (MDS) patients and voriconazole is an alternative, there is currently no direct comparison data available to assess their relative effectiveness. METHOD: We retrospectively reviewed eligible patient charts from January 2017 to February 2019 to identify breakthrough IFD rates, drug adverse event frequency, and drug acquisition cost in AML/MDS patients. RESULTS: Forty-eight patients received 130 chemo cycles, with 50 (38%) cycles prescribed posaconazole and 80 (62%) prescribed voriconazole as primary IFD prophylaxis. The incidence rates of IFD in the posaconazole group were 8% (4 out of 50), of which two were probable and two were possible infections, while 6.26% (5 out of 80) of patients in the voriconazole group developed IFD, with four possible infections and one probable infection (p = 0.73). A higher percentage of patients in the voriconazole group discontinued prophylaxis due to adverse events, with six patients compared to two patients in the posaconazole group (p = 0.15). The drug acquisition cost of posaconazole is 5.62 times more expensive than voriconazole. CONCLUSION: The use of voriconazole instead of posaconazole for 130 chemo cycles would save $166,584.6. Posaconazole and voriconazole have comparable efficacy and safety in preventing IFD in AML and MDS patients receiving chemotherapy. However, posaconazole is more costly than voriconazole.

4.
Biomed Chromatogr ; 38(5): e5845, 2024 May.
Article in English | MEDLINE | ID: mdl-38412513

ABSTRACT

A brompheniramine taste-masked pediatric formulation was developed as part of the National Institutes of Health Pediatric Formulation Initiative to help address low patient compliance caused by the bitter taste of many adult formulations. To confirm that the taste-masked formulation can provide a similar pharmacological effect to the previous marketed adult formulations, a juvenile porcine model was used to screen the model pediatric formulation to compare the bioavailability between the marketed brompheniramine maleate and the taste-masked maleate/tannate formulation. Pigs were dosed orally with both formulations and blood samples were obtained from 0 to 48 h. Plasma samples were prepared and extracted using solid-phase extraction. The mass spectrometer was operated under selected ion monitoring mode. The selected ion monitoring channels were set to m/z 319.1 for brompheniramine and m/z 275.2 for the internal standard chlorpheniramine. Calibration curves were linear over the analytical range 0.2-20 ng/ml (r2 > 0.995) for brompheniramine in plasma. The intra- and inter-day accuracies were between 98.0 and 105% with 5.73% RSD precision. The bioanalytical method was successfully applied to a preclinical bioavailability study. The bioavailability profiles were not significantly different between the two formulations, which demonstrates that taste-masking with tannic acid is a promising approach for formulation modification for pediatric patients.


Subject(s)
Biological Availability , Brompheniramine , Animals , Swine , Brompheniramine/pharmacokinetics , Brompheniramine/chemistry , Brompheniramine/blood , Reproducibility of Results , Taste , Linear Models , Solid Phase Extraction/methods
5.
Surg Today ; 2024 Aug 10.
Article in English | MEDLINE | ID: mdl-39126494

ABSTRACT

PURPOSE: The study aims to present a specialized educational program using a 3D printed model for managing Grade IV and V liver injuries. Hepatic packing, a common technique, may not always achieve sufficient hemostasis in these cases, warranting alternative solutions such as mesh liver wrapping. However, mastering this procedure is challenging due to limited teaching resources and the need for repeated practice. METHODS: A computer-based model was created from an abdominal CT scan to produce a real-sized injured liver model using thermoplastic elastomer TPU-95. Trainees received systematic instruction from an instructor, allowing them to perform the procedure under supervision and independently. RESULTS: Eight surgical residents at Hillel Yaffe Medical Center participated in the program, with the majority successfully completing the procedure under supervision. Furthermore, trainees demonstrated reduced procedure times when performing independently, indicating improved proficiency. CONCLUSION: This educational approach offers a simple and repeatable method for continuous training in managing high-grade liver injuries, holding potential for enhanced patient outcomes.

6.
Surgeon ; 22(1): 37-42, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37652801

ABSTRACT

BACKGROUND: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a method for temporary hemorrhage control used in haemodynamically unwell patients with severe bleeding. In haemodynamically unwell abdominal trauma patients, laparotomy remains the initial procedure of choice. Using REBOA in patients as a bridge to laparotomy is a novel option whose feasibility and efficacy remain unclear. We aimed to assess the clinical outcome in patients with abdominal injury who underwent both REBOA placement and laparotomy. METHODS: This is a retrospective study, including trauma patients with an isolated abdominal injury who underwent both REBOA placement and laparotomy, during the period 2011-2019. All data were collected via the Aortic Balloon Occlusion Trauma Registry database. RESULTS: One hundred and three patients were included in this study. The main mechanism of trauma was blunt injury (62.1%) and the median injury severity score (ISS) was 33 (14-74). Renal failure and multi-organ dysfunction syndrome (MODS) occurred in 15.5% and 35% of patients, respectively. Overall, 30-day mortality was 50.5%. Post balloon inflation systolic blood pressure (SBP) >80 mmHg was associated with lower 24-h mortality (p = 0.007). No differences in mortality were found among patients who underwent partial occlusion vs. total occlusion of the aorta. CONCLUSIONS: Our results support the feasibility of REBOA use in patients with isolated abdominal injury, with survival rates similar to previous reports for haemodynamically unstable abdominal trauma patients. Post-balloon inflation SBP >80 mmHg was associated with a significant reduction in 24-h mortality rates, but not 30-day mortality. Total aortic occlusion was not associated with increased mortality, MODS, and complication rates compared with partial occlusion.


Subject(s)
Abdominal Injuries , Balloon Occlusion , Endovascular Procedures , Shock, Hemorrhagic , Humans , Retrospective Studies , Aorta/surgery , Hemorrhage/etiology , Hemorrhage/therapy , Abdominal Injuries/complications , Abdominal Injuries/surgery , Injury Severity Score , Resuscitation/adverse effects , Resuscitation/methods , Balloon Occlusion/adverse effects , Balloon Occlusion/methods , Registries , Endovascular Procedures/adverse effects , Shock, Hemorrhagic/complications , Shock, Hemorrhagic/therapy
7.
AAPS PharmSciTech ; 25(1): 19, 2024 Jan 24.
Article in English | MEDLINE | ID: mdl-38267707

ABSTRACT

Between February 2020 and January 2022, the Food and Drug Administration (FDA) recalled 281 metformin extended-release products due to the presence of N-nitrosodimethylamine (NDMA) above the acceptable daily intake (ADI, 96 ng/day). Our previous studies indicated presence of NDMA levels above ADI in both metformin immediate and extended-release products. When metformin products have NDMA impurities, it is indispensable to check for the same impurities in metformin combination products. Therefore, the objective of the present study was to evaluate in-use stability of commercial metformin combination products for NDMA. For this purpose, metformin products in combination with glyburide (GB1-GB12), glipizide (GP1-GP8), pioglitazone (P1-P3), alogliptin (A1, A2), and linagliptin (L1, L2) were repacked in pharmacy vials, stored at 30°C/75% RH for 3 months, and monitored for NDMA impurity. The NDMA level varied from 0 to 156.8 ± 32.8 ng/tablet initially and increased to 25.4 ± 5.1 to 455.0 ± 28.4 ng/tablet after 3 months of exposure to in-use condition. Initially, 18 products have NDMA level below ADI limit before exposure which decreased to 7 products (GB5, GP3, GP5, A1, A2, L1, and L2) meeting specification. In conclusion, in-use stability study provides quality and safety risk assessment of drug products where nitroso impurities are detected in the probable condition of use.


Subject(s)
Metformin , Nitrosamines , United States , Humans , United States Food and Drug Administration , Dimethylnitrosamine , Tablets
8.
AAPS PharmSciTech ; 25(7): 202, 2024 Sep 05.
Article in English | MEDLINE | ID: mdl-39237685

ABSTRACT

The focus of the present work was to develop amorphous solid dispersion (ASD) formulation of aprepitant (APT) using sucrose acetate isobutyrate (SAIB) excipient, evaluate for physicochemical attributes, stability, and bioavailability, and compared with hydroxypropyl methylcellulose (HPMC) based formulation. Various formulations of APT were prepared by solvent evaporation method and characterized for physiochemical and in-vivo performance attributes such as dissolution, drug phase, stability, and bioavailability. X-ray powder diffraction indicated crystalline drug conversion into amorphous phase. Dissolution varied as a function of drug:SAIB:excipient proportion. The dissolution was more than 80% in the optimized formulation (F10) and comparable to HPMC based formulation (F13). Stability of F10 and F13 formulations stored at 25 C/60% and 40°C/75% RH for three months were comparable. Both ASD formulations (F10 and F13) were bioequivalent as indicated by the pharmacokinetic parameters Cmax and AUC0-∞. Cmax and AUC0-∞ of F10 and F13 formulations were 2.52 ± 0.39, and 2.74 ± 0.32 µg/ml, and 26.59 ± 0.39, and 24.79 ± 6.02 µg/ml.h, respectively. Furthermore, the bioavailability of ASD formulation was more than twofold of the formulation containing crystalline phase of the drug. In conclusion, stability and oral bioavailability of SAIB based ASD formulation is comparable to HPMC-based formulation of poorly soluble drugs.


Subject(s)
Biological Availability , Excipients , Solubility , Sucrose , Sucrose/analogs & derivatives , Sucrose/chemistry , Administration, Oral , Animals , Excipients/chemistry , Male , Hypromellose Derivatives/chemistry , Chemistry, Pharmaceutical/methods , Drug Stability , X-Ray Diffraction/methods
9.
AAPS PharmSciTech ; 25(1): 20, 2024 Jan 24.
Article in English | MEDLINE | ID: mdl-38267637

ABSTRACT

The aim of this paper was to investigate the effects of formulation parameters on the physicochemical and pharmacokinetic (PK) behavior of amorphous printlets of lopinavir (LPV) manufactured by selective laser sintering 3D printing method (SLS). The formulation variables investigated were disintegrants (magnesium aluminum silicate at 5-10%, microcrystalline cellulose at 10-20%) and the polymer (Kollicoat® IR at 42-57%), while keeping printing parameters constant. Differential scanning calorimetry, X-ray powder diffraction, and Fourier-transform infrared analysis confirmed the transformation of the crystalline drug into an amorphous form. A direct correlation was found between the disintegrant concentration and dissolution. The dissolved drug ranged from 71.1 ± 5.7% to 99.3 ± 2.7% within 120 min. A comparative PK study in rabbits showed significant differences in the rate and extent of absorption between printlets and compressed tablets. The values for Tmax, Cmax, and AUC were 4 times faster, and 2.5 and 1.7 times higher in the printlets compared to the compressed tablets, respectively. In conclusion, the SLS printing method can be used to create an amorphous delivery system through a single continuous process.


Subject(s)
Excipients , Lasers , Animals , Rabbits , Pharmaceutical Preparations , Biological Availability , Lopinavir , Printing, Three-Dimensional
10.
Pak J Med Sci ; 40(1Part-I): 36-40, 2024.
Article in English | MEDLINE | ID: mdl-38196456

ABSTRACT

Background and Objective: A thorough insight into the management of hand injuries can shape the approach of a surgeon in order to achieve optimal outcomes for the patients. The aim of this study was to share our experience in reconstruction of the hand and establishing an algorithm for classification and treatment of hand injuries. Methods: This is a descriptive cross sectional study and was conducted from January 2020 to August 2022 at Burns and Plastic Surgery center, Peshawar. Data was collected from medical records about the patient demographics, mechanism of injury and type of procedures done. Defect size was classified into small (<5cm), medium (5cm to 10 cm) and large (>10cm). The defect site and size was cross tabulated against the method of soft tissue reconstruction in order to make the algorithm for reconstruction of hand injuries. Data was analyzed using SPSS. Results: The study population included 41 (75.9%) male and 13 (24.1%) female patients, mean age 31.56±14.1. Machine injuries (33.3%) and electric burns (24.1%) were the most common cause of hand soft tissue defects. The most commonly performed flap was Posterior introsseous artery (PIA) flap, followed by First dorsal metacarpal artery (FDMA) flap. Flap necrosis was observed in three cases (5.6%). Conclusion: This treatment algorithm for coverage of soft tissue defects in hand injuries will help with the decision making process of hand reconstruction and has didactic value for novice surgeons. It will also form the foundation for further work on this aspect of hand injuries.

SELECTION OF CITATIONS
SEARCH DETAIL