Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 43
Filter
Add more filters

Affiliation country
Publication year range
1.
Europace ; 2023 May 08.
Article in English | MEDLINE | ID: mdl-37155360

ABSTRACT

AIMS: To investigate the exact prevalence of glucose metabolism disorders, and their impact on left atrial (LA) remodelling and reversibility in patients with atrial fibrillation (AF). METHODS AND RESULTS: We examined 204 consecutive patients with AF who underwent their first catheter ablation (CA). Oral glucose tolerance test was used to evaluate glucose metabolism disorders in 157 patients without known diabetes mellitus (DM). Echocardiography was performed before and 6 months after CA. Oral glucose tolerance test identified abnormal glucose metabolism in 86 patients [11 with newly diagnosed DM, 74 with impaired glucose tolerance (IGT) and 1 with impaired fasting glucose (IFG)]. Ultimately, 65.2% of patients had abnormal glucose metabolism. Diabetes mellitus group had the worst LA reservoir strain and LA stiffness (both P < 0.05), while there was no significant difference in baseline LA parameters between normal glucose tolerance (NGT) group and IGT/IFG group. The prevalence of LA reverse remodelling (≥15% decrease in the LA volume index at 6 months after CA) was significantly higher in NGT group compared with IGT/IFG and DM group (64.1 vs. 38.6 vs. 41.5%, P = 0.006). Both DM and IFG/IGT carry a significant risk of lack of LA reverse remodelling independent of baseline LA size and AF recurrence. CONCLUSION: Approximately 65% of patients with AF who underwent their first CA had abnormal glucose metabolism. Patients with DM had significantly impaired LA function compared with non-DM patients. Impaired glucose tolerance/IFG as well as DM carries significant risk of unfavourable LA reverse remodelling. Our observations may provide valuable information regarding the mechanisms and therapeutic strategies of glucose metabolism-related AF.

2.
Int Heart J ; 63(3): 486-491, 2022.
Article in English | MEDLINE | ID: mdl-35650150

ABSTRACT

Asymptomatic or silent atrial fibrillation (AF) has long been a clinical problem due to the incidence of ischemic stroke. A method is needed to predict the development of silent AF before the occurrence of ischemic stroke. This study was focused on the symptoms of AF, especially palpitation, in pacemaker patients. We assessed the hypothesis that absence of palpitation during rapid ventricular pacing could be a predictor of future onset AF being asymptomatic.In this study, we assessed the presence of symptoms during RV pacing and AF symptoms on 145 pacemaker patients at the outpatient clinic by VVI pacing at 120 ppm. The relationship between symptoms during RV pacing and symptom during AF was assessed. The predictive value of absence of symptom during RV pacing on AF being asymptomatic was assessed.Of 145 patients, 74 had previous AF episode. Among the AF patients, absence of symptom during VVI pacing was associated with AF being asymptomatic.Of 145 patients, 71 had no previous AF events. There were 14 patients who had new-onset AF or atrial flutter (AFL) after the device implantation. Four of the 14 patients (28.6%) were symptomatic during first AF/AFL episode, and 10 (71.4%) were asymptomatic during first-onset AF. All ten patients who were asymptomatic during cardiac pacing test were asymptomatic during their initial episodes of AF as well.This study showed that absence of symptoms during rapid ventricular pacing was associated with first-onset AF being asymptomatic.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Ischemic Stroke , Pacemaker, Artificial , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/etiology , Atrial Flutter/complications , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods , Humans , Pacemaker, Artificial/adverse effects
3.
J Cardiovasc Electrophysiol ; 32(8): 2329-2332, 2021 08.
Article in English | MEDLINE | ID: mdl-34164865

ABSTRACT

Parallel connection of an electrophysiology recording system (EP system) to equipment for conduction system pacing (CSP) has been widely used for fine monitoring of intracardiac electrograms and pacing evaluation. We experienced a case showing unexpected pacing threshold exacerbation under specific conditions when the EP system was connected in parallel. We evaluated the underlying mechanism using an ex vivo model. An ex vivo pacing and intracardiac electrogram monitoring model was generated using an oscilloscope, pacing system analyzer (PSA), EP system, and simulated heart. The discrepancy between expected output at the PSA and the actual measured output value at the simulated heart was measured under various conditions and using various combinations of pacing equipment. Parallel connection of the EP system was associated with reduced electrical output from the PSA as recorded at the simulated heart. The unexpected adverse effects were particularly noticeable when using an RMC-5000 EP system with the pacing function on. The trouble is completely resolved by simply turning off the pacing function of the system. There is a possibility that the EP system might increase the pacing threshold in CSP when the PSA and EP system is are deployed in parallel. The issue may provoke pseudo failure of CSP due to the high pacing threshold. When the RMC-5000 is used for conduction system pacing in parallel with a PSA for the pacing test, the pacing function of RMC-5000 should be turned off.


Subject(s)
Bundle of His , Electrophysiologic Techniques, Cardiac , Cardiac Pacing, Artificial , Electrocardiography , Heart Conduction System , Humans
4.
BMC Cardiovasc Disord ; 19(1): 151, 2019 06 21.
Article in English | MEDLINE | ID: mdl-31226943

ABSTRACT

BACKGROUND: Continuous-flow left ventricular assist devices (LVADs) improve survival and morbidity in patients with stage D heart failure. Management of LVADs for longer durations is necessary in some clinical settings, and a better understanding of the hemodynamics of patients using LVADs is warranted. Arrhythmia, including atrial (AA) and ventricular (VAs) arrhythmias, is a modifying factor of hemodynamics that is highly prevalent among patients with LVADs. However, the clinical impact of arrhythmias in various clinical settings in patients with LVAD, in which the hemodynamic load is likely to present as worsening of right heart failure, remains to be completely elucidated. CASE PRESENTATION: We describe the case of a patient under sustained ventricular fibrillation for extraordinarily long duration who was stabilized using LVAD support and in whom newly developed atrial fibrillation led to a significant worsening of right heart failure while using an LVAD. CONCLUSION: This case demonstrates the substantial clinical impact of AAs in the management of right heart failure using an LVAD.


Subject(s)
Atrial Fibrillation/etiology , Heart Failure/therapy , Heart Rate , Heart-Assist Devices , Prosthesis Implantation/instrumentation , Ventricular Fibrillation/complications , Ventricular Function, Left , Ventricular Function, Right , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Disease Progression , Heart Failure/complications , Heart Failure/diagnosis , Heart Failure/physiopathology , Humans , Male , Middle Aged , Prosthesis Implantation/adverse effects , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/physiopathology
5.
Int Heart J ; 60(2): 470-473, 2019 Mar 20.
Article in English | MEDLINE | ID: mdl-30745545

ABSTRACT

A 41-year-old man developed cardiac arrest. A resting 12-lead electrocardiogram showed a delta wave, suggestive of preexcitation syndrome. An electrophysiological test revealed the existence of inducible atrial fibrillation and a fasciculoventricular accessory pathway (FVAP). After these examinations, idiopathic ventricular arrhythmia was suspected. For evaluating concealed Brugada syndrome, pilsicainide was administered, which diminished the delta wave and no Brugada-like electrocardiogram was observed. Ventricular double extra-stimulation from the RV apex easily induced VF, which could not be defibrillated by an external defibrillator, and later stopped spontaneously. These results established the diagnosis of FVAP and idiopathic VF, and not pre-excited atrial fibrillation or Brugada syndrome.


Subject(s)
Accessory Atrioventricular Bundle , Brugada Syndrome/diagnosis , Electric Countershock/methods , Electrocardiography/methods , Pre-Excitation Syndromes , Ventricular Fibrillation/therapy , Accessory Atrioventricular Bundle/diagnosis , Accessory Atrioventricular Bundle/physiopathology , Accessory Atrioventricular Bundle/therapy , Adult , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators , Diagnosis, Differential , Electrophysiologic Techniques, Cardiac/methods , Humans , Male , Pre-Excitation Syndromes/diagnosis , Pre-Excitation Syndromes/physiopathology , Pre-Excitation Syndromes/therapy , Remission, Spontaneous , Treatment Failure
6.
Circ J ; 82(6): 1552-1557, 2018 05 25.
Article in English | MEDLINE | ID: mdl-29657252

ABSTRACT

BACKGROUND: Periprocedural anticoagulation is important in catheter ablation (CA) of atrial fibrillation (AF) and there is increasing evidence that uninterrupted vitamin K antagonist (VKA) therapy is superior to interrupted anticoagulation strategies. Since the emergence of direct oral anticoagulants (DOACs), numerous studies have shown promising results for their use in uninterrupted strategies. However, further studies are needed to further define the efficacy and safety of performing AF ablation with uninterrupted factor XA inhibitors or direct thrombin inhibitors.Methods and Results:We have performed CA of AF without discontinuation of either VKA or DOAC therapy since April 2014. A total of 376 patients with AF underwent CA including pulmonary vein isolation. All of the patients were divided into 2 groups (uninterrupted VKA or uninterrupted DOACs). Anticoagulation with DOACs was associated with fewer complications than uninterrupted VKA therapy (P=0.04). There were significant differences between groups in the rates of congestive heart failure, left ventricular ejection fraction, body weight, and estimated glomerular filtration rate and of the CHADS2, CHA2DS2-VASc and HAS-BLED scores. Therefore, we also analyzed the results using the propensity score-matching method. We found no significant difference in periprocedural complications between uninterrupted VKA or DOACs therapy (P=0.65). CONCLUSIONS: CA of AF without discontinuation of DOACs is not inferior to CA without discontinuation of a VKA, with regard to ischemic or hemorrhagic complications.


Subject(s)
Anticoagulants/therapeutic use , Atrial Fibrillation/therapy , Catheter Ablation/adverse effects , Vitamin K/antagonists & inhibitors , Aged , Cardiac Tamponade/etiology , Catheter Ablation/methods , Female , Hemorrhage/etiology , Humans , Male , Middle Aged , Retrospective Studies , Stroke/etiology
7.
Int Heart J ; 59(6): 1352-1358, 2018 Nov 28.
Article in English | MEDLINE | ID: mdl-30369564

ABSTRACT

Although beta-blockade itself is not a first choice for chronic kidney disease (CKD) patients, alpha-beta-blockers (ABB) do improve their prognoses. This study's aim was to evaluate the effect of beta-selective-blockers (BSB) and ABB on circadian cardiac autonomic activity in CKD patients.The study consisted of 496 non-diabetic individuals who underwent 24-hour Holter monitoring (149 CKD patients and 347 controls without CKD). Using heart rate variability analysis, we evaluated the proportion of NN50 and the high-frequency component (reflecting parasympathetic activity), and low- to high-frequency ratio (reflecting sympathovagal balance). These indices were evaluated by regression analysis incorporating gender, age, related comorbidities, and medications. BSB increased vagal activity only in the day-time and not the night-time in controls. In CKD patients, BSB was significantly related to higher vagal activity throughout the day and with lower sympathovagal balance at night. The night sympathovagal balance of CKD patients taking ABB was significantly higher than that of CKD patients taking BSB, which was the only significant difference between the effects of BSB and ABB.The sympatholytic therapy effect is different depending on CKD presence and whether patients are treated with BSB or ABB. In CKD patients without severe heart failure, BSB could be associated with higher parasympathetic activity and lower sympathovagal balance compared to ABB.


Subject(s)
Adrenergic alpha-Antagonists/pharmacology , Adrenergic beta-Antagonists/pharmacology , Autonomic Nervous System/drug effects , Heart Rate/drug effects , Renal Insufficiency, Chronic/drug therapy , Sympatholytics/pharmacology , Vagus Nerve/drug effects , Adrenergic alpha-Antagonists/therapeutic use , Adrenergic beta-Antagonists/therapeutic use , Adult , Aged , Case-Control Studies , Female , Humans , Male , Middle Aged , Multivariate Analysis , Renal Insufficiency, Chronic/physiopathology , Retrospective Studies , Sympatholytics/therapeutic use
8.
Int Heart J ; 59(3): 626-629, 2018 May 30.
Article in English | MEDLINE | ID: mdl-29628471

ABSTRACT

A cardiac resynchronization therapy defibrillator (CRT-D) (Medtronic Inc. Protecta XT) was implanted in a 67-year-old man who had cardiac sarcoidosis with extremely low cardiac function. He had ventricular tachycardia which was controlled by catheter ablation, medication and pacing. The programmed mode was DDI, lower rate was 90 beats/minute, paced AV delay was 150 ms, and the noncompetitive atrial pacing (NCAP) function was programmed as 300 ms.After his admission for pneumonia and heart failure, we changed his DDI mode to a DDD mode because he had atrial tachycardia, which led to inadequate bi-ventricular pacing. After a while, there were cycle lengths which were longer than his device setting and alternately varied. We were able to avoid this phenomenon with AV delay of 120 ms and NCAP of 200 ms.NCAP is an algorithm which creates a gap above a certain period after the detection of an atrial signal during the postventricular atrial refractory period of the pacemaker. This is to prevent atrial tachycardia and repetitive non-reentrant ventriculoatrial (VA) synchrony in the presence of retrograde VA conduction. But in this case, NCAP algorithm induced much lower rate than the programmed basic lower rate. This situation produced some arrhythmias and exacerbated symptoms of heart failure. This had to be paid attention to, especially when the device was programmed at high basic heart rate.


Subject(s)
Arrhythmias, Cardiac/etiology , Cardiac Resynchronization Therapy/adverse effects , Defibrillators, Implantable/adverse effects , Aged , Algorithms , Arrhythmias, Cardiac/therapy , Cardiac Resynchronization Therapy/methods , Electrocardiography , Heart Failure/complications , Heart Failure/therapy , Heart Rate/physiology , Humans , Male
9.
Int Heart J ; 58(5): 816-819, 2017 Oct 21.
Article in English | MEDLINE | ID: mdl-28966329

ABSTRACT

Ebstein's anomaly is a rare congenital heart disease characterized by apical displacement of the septal and posterior tricuspid valve leaflets. It is often complicated with left ventricular (LV) dysfunction as well as right-sided abnormalities. On the other hand, in the presence of LV dysfunction, right ventricular pacing is likely to aggravate the diseased LV function, which is termed pacemaker-induced cardiomyopathy. Thus, deteriorating effects of RV pacing on cardiac function might be enhanced and result in pacemaker-induced cardiomyopathy in patients with Ebstein's anomaly, even if they have preserved LVEF. Cardiac resynchronization therapy (CRT) is effective for the treatment of pacemaker-induced cardiomyopathy, and we present the first case of effect of CRT on pacemaker-induced cardiomyopathy associated with Ebstein's anomaly.


Subject(s)
Cardiac Pacing, Artificial/adverse effects , Defibrillators, Implantable , Ebstein Anomaly/therapy , Heart Ventricles/physiopathology , Ventricular Dysfunction, Left/therapy , Ventricular Function, Left/physiology , Aged , Cardiac Pacing, Artificial/methods , Cephalosporins , Echocardiography , Electrocardiography , Female , Heart Ventricles/diagnostic imaging , Humans , Stroke Volume/physiology , Ventricular Dysfunction, Left/diagnosis , Ventricular Dysfunction, Left/etiology
10.
Int Heart J ; 58(1): 140-143, 2017 Feb 07.
Article in English | MEDLINE | ID: mdl-28123162

ABSTRACT

Cardiac involvement in systemic sarcoidosis sometimes provokes life-threatening ventricular tachyarrhythmia. Steroid administration is one of the fundamental anti-arrhythmia therapies. For an indication of steroid therapy, a definitive diagnosis of sarcoidosis is required.1) However, cases that are clearly suspected of cardiac sarcoidosis based on their clinical courses sometimes do not meet the current diagnostic criteria and result in the loss of an appropriate opportunity to perform steroid therapy.Here we report a case that was diagnosed as sarcoidosis by incidental biopsy of an inguinal lymph node during cardiac resuscitation for cardiac tamponade.2) While the inguinal lymph node was not swollen on computed tomography, a specimen obtained from an incidental biopsy during the exposure of a femoral vessel for the establishment of extracorporeal cardio-pulmonary resuscitation showed a non-caseating granuloma.This findings suggest a non-swelling lymph node biopsy might be an alternative strategy for the diagnosis for sarcoidosis if other standard strategies do not result in a diagnosis of sarcoidosis.


Subject(s)
Heart Diseases/diagnosis , Incidental Findings , Lymph Nodes/pathology , Sarcoidosis/diagnosis , Female , Humans , Lymph Nodes/diagnostic imaging , Magnetic Resonance Imaging , Middle Aged , Sarcoidosis/pathology , Tomography, X-Ray Computed
12.
Sci Rep ; 14(1): 6916, 2024 03 22.
Article in English | MEDLINE | ID: mdl-38519537

ABSTRACT

Risk factors for pacemaker-induced cardiomyopathy (PICM) have been previously reported, including a high burden of right ventricular pacing, lower left ventricular ejection fraction, a wide QRS duration, and left bundle branch block before pacemaker implantation (PMI). However, predicting the development of PICM remains challenging. This study aimed to use a convolutional neural network (CNN) model, based on clinical findings before PMI, to predict the development of PICM. Out of a total of 561 patients with dual-chamber PMI, 165 (mean age 71.6 years, 89 men [53.9%]) who underwent echocardiography both before and after dual-chamber PMI were enrolled. During a mean follow-up period of 1.7 years, 47 patients developed PICM. A CNN algorithm for prediction of the development of PICM was constructed based on a dataset prior to PMI that included 31 variables such as age, sex, body mass index, left ventricular ejection fraction, left ventricular end-diastolic diameter, left ventricular end-systolic diameter, left atrial diameter, severity of mitral regurgitation, severity of tricuspid regurgitation, ischemic heart disease, diabetes mellitus, hypertension, heart failure, New York Heart Association class, atrial fibrillation, the etiology of bradycardia (sick sinus syndrome or atrioventricular block) , right ventricular (RV) lead tip position (apex, septum, left bundle, His bundle, RV outflow tract), left bundle branch block, QRS duration, white blood cell count, haemoglobin, platelet count, serum total protein, albumin, aspartate transaminase, alanine transaminase, estimated glomerular filtration rate, sodium, potassium, C-reactive protein, and brain natriuretic peptide. The accuracy, sensitivity, specificity, and area under the curve of the CNN model were 75.8%, 55.6%, 83.3% and 0.78 respectively. The CNN model could accurately predict the development of PICM using clinical findings before PMI. This model could be useful for screening patients at risk of developing PICM, ensuring timely upgrades to physiological pacing to avoid missing the optimal intervention window.


Subject(s)
Cardiomyopathies , Pacemaker, Artificial , Male , Humans , Aged , Stroke Volume , Bundle-Branch Block/therapy , Bundle-Branch Block/complications , Ventricular Function, Left , Cardiac Pacing, Artificial/adverse effects , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/etiology , Pacemaker, Artificial/adverse effects , Arrhythmias, Cardiac/etiology , Neural Networks, Computer
13.
J Cardiol Cases ; 29(6): 244-247, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38826767

ABSTRACT

Patients with congenitally corrected transposition of the great arteries (ccTGA) often develop complete atrioventricular block and heart failure due to the abnormal disposition of atrioventricular node and disadvantage of systemic right ventricle. These issues are managed with a pacing system and a ventricular assist device (VAD), respectively. While technological advances offer new treatment strategies, the simultaneous deployment of a leadless pacemaker and a VAD in cases of ccTGA remains unexplored. Here, we present a case of leadless pacemaker implantation for a VAD-supported ccTGA patient. The safety of a leadless pacemaker for a subpulmonary left ventricle and electromagnetic interference between devices are major concerns when implanting a leadless pacemaker; however, the current case overcomes these obstacles. There were no perioperative complications, and both devices were functioning without problems during a one-year follow up. We expect that, even in patients with cardiac complexity such as systemic right ventricle under VAD support, a leadless pacemaker could become the treatment of choice if the indication is appropriate, although careful and close follow up is needed. Learning objective: Technological advances expand treatment strategies and provide significant benefits to patients with adult congenital heart disease (ACHD). However, discussion of the combination of a leadless pacemaker and a ventricular assist device (VAD) is rare. We demonstrated the efficacy of a leadless pacemaker for a subpulmonary left ventricle in a patient with systemic right ventricle on VAD. This approach could be an option even for ACHD patients.

14.
J Am Heart Assoc ; 13(1): e032215, 2024 Jan 02.
Article in English | MEDLINE | ID: mdl-38156556

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) progression is closely related to heart failure occurrence, and catheter ablation carries a beneficial effect for heart failure prevention. Recently, particular attention has been given to left atrial (LA) function and functional reserve in the pathogenesis linking AF and heart failure, although its significance and reversibility is not well studied. METHODS AND RESULTS: We prospectively investigated 164 patients with AF with normal left ventricular systolic function and free from heart failure who underwent first catheter ablation and pre-/postprocedural echocardiography. Conventional and speckle-tracking echocardiography were performed at rest and during passive leg lifting to assess LA size, LA reservoir strain (LARS), and functional reserve calculated as passive leg lifting-LARS - rest-LARS. Patients were categorized into 3 AF subtypes: paroxysmal AF (N=95), persistent AF (PeAF; N=50), and long-standing persistent AF (LS-PeAF; N=19). The PeAF and LS-PeAF groups had larger LA size and reduced LARS compared with the paroxysmal AF group (all P<0.05). LA functional reserve was significantly impaired in the LS-PeAF group (P=0.003). In multivariable analysis, LS-PeAF and advanced age were significantly associated with impaired LA functional reserve. Among 149 patients with sinus rhythm 1 to 2 days after catheter ablation, LARS was significantly improved in both PeAF and LS-PeAF groups but was still lower than that in the paroxysmal AF group. Sinus rhythm restoration also led to amelioration of LA functional reserve in patients with LS-PeAF. CONCLUSIONS: AF progression was related to impaired LARS and LA functional reserve, and restoration of sinus rhythm might contribute to early LA reverse remodeling.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Atrial Remodeling , Catheter Ablation , Heart Failure , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/etiology , Atrial Fibrillation/surgery , Heart Atria , Atrial Appendage/surgery , Echocardiography/methods , Catheter Ablation/methods , Treatment Outcome
15.
Sci Rep ; 14(1): 21882, 2024 09 19.
Article in English | MEDLINE | ID: mdl-39300151

ABSTRACT

Hypertension is a significant contributor to premature mortality, and the regular monitoring of blood pressure (BP) enables the early detection of hypertension and cardiovascular disease. There is an urgent need for the development of highly accurate cuffless BP devices. We examined BP measurements based on a target spectral camera's recordings and evaluated their accuracy. Images of 215 adults' palms and faces were recorded, and BP was measured. The camera captured RGB wavelength data at 640 × 480 pixels and 150 frames per second (fps). These recordings were analyzed to extract pulse transit time (PTT) values between the face and palm, a key parameter for estimating BP. Continuous BP measurements were taken using a CNAPmonitor500 for validation. Three frequency wavelengths were measured from video images. A machine learning model was constructed to determine hypertension, defined as a systolic BP of 130 mmHg or higher or a diastolic BP of 80 mmHg or higher, using the visualized data. The discrimination between hypertension and normal BP was 95.0% accurate within 30 s and 90.3% within 5 s, based on the captured images. The results of heartbeat-by-heartbeat analyses can be used to determine hypertension based on only one second of camera footage or one heartbeat. The data extracted from a video recorded by a target spectral camera enabled accurate hypertension diagnoses, suggesting the potential for simplified BP monitoring.


Subject(s)
Blood Pressure Determination , Hypertension , Humans , Hypertension/diagnosis , Hypertension/physiopathology , Male , Female , Middle Aged , Adult , Prospective Studies , Blood Pressure Determination/methods , Blood Pressure Determination/instrumentation , Blood Pressure , Aged , Pulse Wave Analysis/methods , Machine Learning , Heart Rate , Young Adult
16.
JACC Adv ; 3(6): 100973, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38938865

ABSTRACT

Background: Emerging evidence suggests a pathophysiological link between obesity and atrial fibrillation (AF). However, the contribution of body fat distribution to left atrial (LA) remodeling and its reversibility remain unclear in nonobese AF patients. Objectives: The purpose of this study was to investigate the association of body fat distribution with LA size and reverse remodeling (LARR). Methods: In total, 116 nonobese patients with AF (88 men, age 63 ± 11 years) who underwent first catheter ablation (CA) were included. Body fat distribution was assessed with bioelectrical impedance, and body fat percentage (BF%) and central fat percentage (CF%) were calculated. Patients were categorized by body size metrics (body mass index [BMI] and waist-to-hip [W/H] ratio) and fat parameters (BF% and CF%). Echocardiography was performed before and 6 months after CA. Multivariable logistic regression was used to examine the association between the 4 metrics (ie, BMI, W/H ratio, BF%, and CF%) and a lack of LARR (<15% reduction or increase in the LA volume index). Results: Body size metrics and adiposity measures were not independently associated with baseline LA size. Six months after CA, the higher W/H ratio and CF% groups exhibited persistent LA enlargement compared to their counterparts (both P < 0.01). In the multivariable analysis, W/H ratio and CF% were associated with a lack of LARR (adjusted ORs of 3.86 and 2.81 per 0.10 and 10% increase, respectively, both P < 0.01). The combined assessment of CF% with W/H ratio provided complementary risk stratification for persistent LA enlargement. Conclusions: Central adiposity was associated with a lack of LARR after CA, highlighting the importance of assessing body fat distribution even in nonobese patients.

17.
Sci Immunol ; 9(95): eade3814, 2024 May 24.
Article in English | MEDLINE | ID: mdl-38787963

ABSTRACT

Patients with heart failure (HF) often experience repeated acute decompensation and develop comorbidities such as chronic kidney disease and frailty syndrome. Although this suggests pathological interaction among comorbidities, the mechanisms linking them are poorly understood. Here, we identified alterations in hematopoietic stem cells (HSCs) as a critical driver of recurrent HF and associated comorbidities. Bone marrow transplantation from HF-experienced mice resulted in spontaneous cardiac dysfunction and fibrosis in recipient mice, as well as increased vulnerability to kidney and skeletal muscle insults. HF enhanced the capacity of HSCs to generate proinflammatory macrophages. In HF mice, global chromatin accessibility analysis and single-cell RNA-seq showed that transforming growth factor-ß (TGF-ß) signaling was suppressed in HSCs, which corresponded with repressed sympathetic nervous activity in bone marrow. Transplantation of bone marrow from mice in which TGF-ß signaling was inhibited similarly exacerbated cardiac dysfunction. Collectively, these results suggest that cardiac stress modulates the epigenome of HSCs, which in turn alters their capacity to generate cardiac macrophage subpopulations. This change in HSCs may be a common driver of repeated HF events and comorbidity by serving as a key carrier of "stress memory."


Subject(s)
Heart Failure , Immunity, Innate , Immunologic Memory , Mice, Inbred C57BL , Animals , Heart Failure/immunology , Mice , Male , Multimorbidity , Transforming Growth Factor beta/metabolism , Hematopoietic Stem Cells/immunology , Signal Transduction/immunology , Macrophages/immunology , Trained Immunity
19.
Int Heart J ; 54(2): 111-4, 2013.
Article in English | MEDLINE | ID: mdl-23676372

ABSTRACT

Although hypertrophic cardiomyopathy (HCM) with an accessory pathway is encountered in clinical practice, there is little evidence of a coherent strategy for ablation of the accessory pathway in patients with HCM. We present the case of a 61-year-old man who had type B Wolff-Parkinson-White (WPW) syndrome with hypertrophic obstructive cardiomyopathy (HOCM). Due to paroxysmal atrial fibrillation, he underwent radiofrequency catheter ablation of the accessory pathway located in the right postero-lateral wall to prevent secondary symptomatic events. His LV dyssynchrony improved after the procedure, but the degree of the LV outflow tract (LVOT) pressure gradient was increased. To stabilize the LVOT pressure gradient, he needed additional medications. This case shows that patients with HOCM should be carefully evaluated before making a decision concerning ablation of the accessory pathway.


Subject(s)
Atrial Fibrillation/complications , Cardiomyopathy, Hypertrophic/complications , Catheter Ablation/adverse effects , Ventricular Outflow Obstruction/complications , Wolff-Parkinson-White Syndrome/complications , Atrial Fibrillation/surgery , Humans , Male , Middle Aged , Pressure
20.
J Environ Sci (China) ; 25(12): 2507-15, 2013 Dec 01.
Article in English | MEDLINE | ID: mdl-24649684

ABSTRACT

The amount of carbon dioxide (CO2) absorption and calcium ion (Ca2+) concentration besides the pH of aqueous solution were observed during the CO2 absorption to precipitate calcium carbonate (CaCO3) from calcium hydroxide (Ca(OH)2). A reaction rate-limiting effect of an amount of CO2 absorption without any organic additives in the early stage of the precipitation was observed, which was attributed to an interruption effect of bicarbonate ion (HCO3(-)) on the precipitation of CaCO3. The improvement for the reaction rate was achieved not only by amine additives but also by neutral additives such as epsilon-caprolactam or amine salt. When the hexamethylene diamine was dissolved in the solution, successive change of crystal forms of CaCO3 aragonite to calcite in aqueous suspensions, confirmed by Ca2+ concentration change and X-ray diffraction, was concluded that a local environment around the amine group in aqueous solution and an interaction of the diamine with precipitated CaCO3 particles were important factors for these reactions.


Subject(s)
Amides/chemistry , Amines/chemistry , Calcium Carbonate/chemical synthesis , Calcium Hydroxide/chemistry , Carbon Dioxide/chemistry , Adsorption , Chemical Precipitation , Hydrogen-Ion Concentration
SELECTION OF CITATIONS
SEARCH DETAIL