ABSTRACT
Biosensors for sensitive and specific detection of foodborne and waterborne pathogens are particularly valued for their portability, usability, relatively low cost, and real-time or near real-time response. Their application is widespread in several domains, including environmental monitoring. The main limitation of currently developed biosensors is a lack of sensitivity and specificity in complex matrices. Due to increased interest in biosensor development, we conducted a systematic review, complying with the PRISMA guidelines, covering the period from January 2010 to December 2019. The review is focused on biosensor applications in the identification of foodborne and waterborne microorganisms based on research articles identified in the Pubmed, ScienceDirect, and Scopus search engines. Efforts are still in progress to overcome detection limitations and to provide a rapid detection system which will safeguard water and food quality. The use of biosensors is an essential tool with applicability in the evaluation and monitoring of the environment and food, with great impact in public health.
Subject(s)
Biosensing Techniques , Water , Bacteria , Environmental Monitoring , FoodABSTRACT
Wastewater-based epidemiology, during the COVID-19 pandemic years, has been applied as a complementary approach, worldwide, for tracking SARS-CoV-2 virus into the community and used as an early warning of the prevalence of COVID-19 infection. The present study presents the results of the 2-year surveillance project, in the city of Patras, Greece. The purpose of the study was to monitor SARS-CoV-2 and implement WBE as an early warning method of monitoring Public Health impact. The presence of SARS-CoV-2 was determined and quantified in 310 samples using RT-qPCR assays. For the years 2022 and 2023, 93.5% and 78.7% of samples were found positive, respectively. Comparison of detection methods have been conducted to select the method with the highest recovery of the viral load. A seasonal variation of the virus was recorded, showing a recession in summer months confirming the country's epidemiological data as indicated by positive correlation of wastewater viral load with registered cases of COVID-19 infections during these years (p < 0.05) and moreover sealed with a significant negative correlation observed with Daily Average (p < 0.01) and Daily Maximum Temperature (p < 0.01). More research was carried out to elucidate a possible association of physicochemical characteristics of wastewater with viral load showing positive correlation with Chlorides (p < 0.01) advocating possible increased use of chlorine-based disinfectants and Electrical Conductivity (p < 0.01) indicates that wastewater during periods of increased infections is more heavily loaded with ions from chemical and biological pollutants. No correlation found with rainfall and physicochemical indicators, such as COD, BOD5, Total Phosphorus, Total Nitrogen, and Total Suspended Solids. According to the findings, WBE represents a useful tool in the management of epidemics based on an environmental approach and it can also shed light on the interacting parameters that capture Public Health since any infections that may lead to epidemics lead to a parallel change in the use of pharmaceuticals, antimicrobials, disinfectants, and microbial load in urban wastewater.
Subject(s)
COVID-19 , Cities , SARS-CoV-2 , Wastewater , Greece/epidemiology , Wastewater/virology , Humans , COVID-19/epidemiology , COVID-19/virology , COVID-19/transmission , SARS-CoV-2/isolation & purification , SARS-CoV-2/genetics , SARS-CoV-2/drug effects , Viral Load , Seasons , Wastewater-Based Epidemiological MonitoringABSTRACT
Hepatitis E virus (HEV) poses significant health concerns worldwide, particularly among people living with HIV (PLWHIV), due to an increased risk of chronic infection and progression to cirrhosis in individuals with low CD4 cell counts. This study aimed to investigate the prevalence, chronicity potential, and risk factors of HEV infection among PLWHIV in Greece, where data are currently absent. A synchronic multicentric study encompassing five major Greek university hospitals was executed over 24 months, recruiting 696 PLWHIV participants. The prevalence of HEV IgG antibodies was 16.5%, with 8.6% showing evidence of acute HEV infection (HEV IgM). Active viral replication (HEV RNA) was present in 2.3% of the study population. Longitudinal analysis revealed that of the 25 initially anti-HEV IgM-positive individuals, only 3 seroconverted to IgG positivity, and among those with prior HEV RNA positivity (16), none showed evidence of active replication in subsequent tests. Comparative subgroup analysis highlighted the lack of significant differences in HIV-related parameters between HEV seropositive and seronegative individuals. Laboratory evaluations generally showed no significant disparities across most parameters; however, a higher seropositivity for Hepatitis A was observed in the HEV-positive subgroup. Our findings highlight a considerable prevalence of HEV among PLWHIV in Greece, with no observed cases of chronicity.