Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters

Database
Country/Region as subject
Publication year range
1.
Phys Rev Lett ; 126(13): 131103, 2021 Apr 02.
Article in English | MEDLINE | ID: mdl-33861094

ABSTRACT

We report on the first subpicometer interferometer flown in space. It was part of ESA's Laser Interferometer Space Antenna (LISA) Pathfinder mission and performed the fundamental measurement of the positional and angular motion of two free-falling test masses. The interferometer worked immediately, stably, and reliably from switch on until the end of the mission with exceptionally low residual noise of 32.0_{-1.7}^{+2.4} fm/sqrt[Hz], significantly better than required. We present an upper limit for the sensor performance at millihertz frequencies and a model for the measured sensitivity above 200 mHz.

2.
Phys Rev Lett ; 123(11): 111101, 2019 Sep 13.
Article in English | MEDLINE | ID: mdl-31573236

ABSTRACT

We report on the results of the LISA Pathfinder (LPF) free-fall mode experiment, in which the control force needed to compensate the quasistatic differential force acting on two test masses is applied intermittently as a series of "impulse" forces lasting a few seconds and separated by roughly 350 s periods of true free fall. This represents an alternative to the normal LPF mode of operation in which this balancing force is applied continuously, with the advantage that the acceleration noise during free fall is measured in the absence of the actuation force, thus eliminating associated noise and force calibration errors. The differential acceleration noise measurement presented here with the free-fall mode agrees with noise measured with the continuous actuation scheme, representing an important and independent confirmation of the LPF result. An additional measurement with larger actuation forces also shows that the technique can be used to eliminate actuation noise when this is a dominant factor.

3.
Phys Rev Lett ; 120(6): 061101, 2018 Feb 09.
Article in English | MEDLINE | ID: mdl-29481269

ABSTRACT

In the months since the publication of the first results, the noise performance of LISA Pathfinder has improved because of reduced Brownian noise due to the continued decrease in pressure around the test masses, from a better correction of noninertial effects, and from a better calibration of the electrostatic force actuation. In addition, the availability of numerous long noise measurement runs, during which no perturbation is purposely applied to the test masses, has allowed the measurement of noise with good statistics down to 20 µHz. The Letter presents the measured differential acceleration noise figure, which is at (1.74±0.05) fm s^{-2}/sqrt[Hz] above 2 mHz and (6±1)×10 fm s^{-2}/sqrt[Hz] at 20 µHz, and discusses the physical sources for the measured noise. This performance provides an experimental benchmark demonstrating the ability to realize the low-frequency science potential of the LISA mission, recently selected by the European Space Agency.

4.
Ann N Y Acad Sci ; 927: 110-26, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11411149

ABSTRACT

We reconsider the problem of nonlinear structure formation inside and outside General Relativity (GR), both in the weakly and strongly nonlinear regime. We show how these regimes can be explored observationally through clustering of high-order cumulants and through the epoch of formation, abundance and clustering of collapse structures, using Press and Schechter (1974, Astrophys. J. 187: 425-438) formalism and its extensions.

7.
Am J Bot ; 88(11): 2113-8, 2001 Nov.
Article in English | MEDLINE | ID: mdl-21669642

ABSTRACT

Several studies have demonstrated, using controlled pollinations, that the number and identity of pollen grains deposited onto a flower's stigma affect the reproductive success of plants. However, few studies have shown this relationship under conditions of natural pollination. Using the tropical dry forest tree Pachira quinata, we evaluated the relationship between the number of microgametophytes per pistil and the number of sires with respect to the production of fruits and seeds in a natural population of Pachira quinata. Our study demonstrates that fruit and seed production are directly related to the number of microgametophytes per pistil in natural populations of P. quinata. Only 6% of the marked flowers developed into mature fruits and 10% of the marked flowers initiated fruits but later aborted them. A mean of 23 pollen grains were required to produce a seed. Flowers with >400 pollen grains on the stigma always developed into mature fruits, whereas flowers that received <200 grains never matured fruits. Half of the pollen grains transferred to a flower stigma germinated and developed pollen tubes to the base of the style. The number of pollen grains on a stigma explained 34% of the variation in seed number per fruit, and the number of seeds produced per fruit is positively correlated with the size of the seeds. The population of P. quinata studied is predominantly outcrossing, and seeds within fruits are sired by one or a few donors. The total seed crop within trees was sired by three to five donors. Our study examined the implications of the variation in size of microgametophyte loads per pistil with respect to the breeding system and the paternity of progeny under natural conditions. The competitive ability of pollen and pollen tube attrition are important factors regulating fruit production in P. quinata.

8.
Phys Rev Lett ; 87(3): 031101, 2001 Jul 16.
Article in English | MEDLINE | ID: mdl-11461547

ABSTRACT

We present the concept of a sensitive and broadband resonant mass gravitational wave detector. A massive sphere is suspended inside a second hollow one. Short, high-finesse Fabry-Perot optical cavities read out the differential displacements of the two spheres as their quadrupole modes are excited. At cryogenic temperatures, one approaches the standard quantum limit for broadband operation with reasonable choices for the cavity finesses and the intracavity light power. A molybdenum detector, of overall size of 2 m, would reach spectral strain sensitivities of 2x10(-23) Hz(-1/2) between 1000 and 3000 Hz.

SELECTION OF CITATIONS
SEARCH DETAIL