Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Magn Reson Med ; 92(2): 543-555, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38688865

ABSTRACT

PURPOSE: To determine whether intravoxel incoherent motion (IVIM) describes the blood perfusion in muscles better, assuming pseudo diffusion (Bihan Model 1) or ballistic motion (Bihan Model 2). METHODS: IVIM parameters were measured in 18 healthy subjects with three different diffusion gradient time profiles (bipolar with two diffusion times and one with velocity compensation) and 17 b-values (0-600 s/mm2) at rest and after muscle activation. The diffusion coefficient, perfusion fraction, and pseudo-diffusion coefficient were estimated with a segmented fit in the gastrocnemius medialis (GM) and tibialis anterior (TA) muscles. RESULTS: Velocity-compensated gradients resulted in a decreased perfusion fraction (6.9% ± 1.4% vs. 4.4% ± 1.3% in the GM after activation) and pseudo-diffusion coefficient (0.069 ± 0.046 mm2/s vs. 0.014 ± 0.006 in the GM after activation) compared to the bipolar gradients with the longer diffusion encoding time. Increased diffusion coefficients, perfusion fractions, and pseudo-diffusion coefficients were observed in the GM after activation for all gradient profiles. However, the increase was significantly smaller for the velocity-compensated gradients. A diffusion time dependence was found for the pseudo-diffusion coefficient in the activated muscle. CONCLUSION: Velocity-compensated diffusion gradients significantly suppress the IVIM effect in the calf muscle, indicating that the ballistic limit is mostly reached, which is supported by the time dependence of the pseudo-diffusion coefficient.


Subject(s)
Diffusion Magnetic Resonance Imaging , Muscle, Skeletal , Humans , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/physiology , Adult , Male , Female , Motion , Leg/diagnostic imaging , Leg/blood supply , Young Adult , Image Processing, Computer-Assisted/methods , Algorithms
2.
Magn Reson Med ; 90(1): 270-279, 2023 07.
Article in English | MEDLINE | ID: mdl-36861449

ABSTRACT

PURPOSE: Studies on intravoxel incoherent motion (IVIM) imaging in the liver have been carried out with different acquisition protocols. The number of acquired slices and the distances between slices can influence IVIM measurements due to saturation effects, but these effects have often been disregarded. This study investigated differences in biexponential IVIM parameters between two slice settings. METHODS: Fifteen healthy volunteers (21-30 years) were examined at a field strength of 3 T. Diffusion-weighted images of the abdomen were acquired with 16 b values (0-800 s/mm2 ), with four slices for the few slices setting and 24-27 slices for the many slices setting. Regions of interest were manually drawn in the liver. The data were fitted with a monoexponential signal curve and a biexponential IVIM curve, and biexponential IVIM parameters were determined. The dependence on the slice setting was assessed with Student's t test for paired samples (normally distributed IVIM parameters) and the Wilcoxon signed-rank test (non-normally distributed parameters). RESULTS: None of the parameters were significantly different between the settings. For few slices and many slices, respectively, the mean values (SDs) for D $$ D $$ were 1.21 µm 2 / ms $$ 1.21{\upmu \mathrm{m}}^2/\mathrm{ms} $$ ( 0.19 µm 2 / ms $$ 0.19\kern0.3em {\upmu \mathrm{m}}^2/\mathrm{ms} $$ ) and 1.20 µm 2 / ms $$ 1.20{\upmu \mathrm{m}}^2/\mathrm{ms} $$ ( 0.11 µm 2 / ms $$ 0.11\kern0.3em {\upmu \mathrm{m}}^2/\mathrm{ms} $$ ); for f $$ f $$ they were 29.7% (6.2%) and 27.7% (3.6%); and for D * $$ {D}^{\ast } $$ they were 8.76 ⋅ 10 - 2 mm 2 / s $$ 8.76\cdot {10}^{-2}{\mathrm{mm}}^2/\mathrm{s} $$ ( 4.54 ⋅ 10 - 2 mm 2 / s $$ 4.54\cdot {10}^{-2}\kern0.3em {\mathrm{mm}}^2/\mathrm{s} $$ ) and 8.71 ⋅ 10 - 2 mm 2 / s $$ 8.71\cdot {10}^{-2}{\mathrm{mm}}^2/\mathrm{s} $$ ( 4.06 ⋅ 10 - 2 mm 2 / s $$ 4.06\cdot {10}^{-2}\kern0.3em {\mathrm{mm}}^2/\mathrm{s} $$ ). CONCLUSION: Biexponential IVIM parameters in the liver are comparable among IVIM studies that use different slice settings, with mostly negligible saturation effects. However, this may not hold for studies that use much shorter TR.


Subject(s)
Abdomen , Liver , Humans , Liver/diagnostic imaging , Motion , Abdomen/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Diffusion Magnetic Resonance Imaging/methods
3.
Magn Reson Med ; 87(2): 859-871, 2022 02.
Article in English | MEDLINE | ID: mdl-34453445

ABSTRACT

PURPOSE: Intravoxel incoherent motion (IVIM) studies are performed with different acquisition protocols. Comparing them requires knowledge of echo time (TE) dependencies. The TE-dependence of the biexponential perfusion fraction f is well-documented, unlike that of its triexponential counterparts f1 and f2 and the biexponential and triexponential pseudodiffusion coefficients D* , D1∗ , and D2∗ . The purpose was to investigate the TE-dependence of these parameters and to check whether the triexponential pseudodiffusion compartments are associated with arterial and venous blood. METHODS: Fifteen healthy volunteers (19-58 y; mean: 24.7 y) underwent diffusion-weighted imaging of the abdomen with 24 b-values (0.2-800 s/mm2 ) at TEs of 45, 60, 75, and 90 ms. Regions of interest (ROIs) were manually drawn in the liver. One set of bi- and triexponential IVIM parameters per volunteer and TE was determined. The TE-dependence was assessed with the Kruskal-Wallis test. RESULTS: TE-dependence was observed for f (P < .001), f1 (P = .001), and f2 (P < .001). Their median values at the four measured TEs were: f: 0.198/0.240/0.274/0.359, f1 : 0.113/0.139/0.146/0.205, f2 : 0.115/0.155/0.182/0.194. D, D* , D1∗ , and D2∗ showed no significant TE-dependence. Their values were: diffusion coefficient D (10-4 mm2 /s): 9.45/9.63/9.75/9.41, biexponential D* (10-2 mm2 /s): 5.26/5.52/6.13/5.82, triexponential D1∗ (10-2 mm2 /s): 1.73/2.91/2.25/2.51, triexponential D2∗ (mm2 /s): 0.478/1.385/0.616/0.846. CONCLUSION: f1 and f2 show similar TE-dependence as f, ie, increase with rising TE; an effect that must be accounted for when comparing different studies. The diffusion and pseudodiffusion coefficients might be compared without TE correction. Because of the similar TE-dependence of f1 and f2 , the triexponential pseudodiffusion compartments are most probably not associated to venous and arterial blood.


Subject(s)
Algorithms , Diffusion Magnetic Resonance Imaging , Abdomen , Humans , Liver/diagnostic imaging , Motion , Reproducibility of Results
4.
PLoS One ; 19(8): e0306996, 2024.
Article in English | MEDLINE | ID: mdl-39121035

ABSTRACT

OBJECTIVES: This study aims to investigate the previously reported dependency of intravoxel incoherent motion (IVIM) parameters on simultaneous multislice (SMS) acquisition and repetition time (TR). This includes the influence of slice thickness, slice gaps, and slice order on measured IVIM parameters. MATERIALS AND METHODS: Diffusion-weighted imaging (DWI) of the liver was performed on 10 healthy volunteers (aged 20-30 years) at 3T with a slice thickness of 5 mm, a slice gap of 5 mm, and a linear slice order. Diffusion-weighted images were acquired with 19 b-values (0-800 s/mm2) using both conventional slice excitation with an acceleration factor of one (AF1) and SMS excitation with an acceleration factor of three (AF3). Each of these measurements were carried out with two repetition times (TRs)- 1,300 ms (prefix s) and 4,500 ms (prefix l)-resulting in four different combinations: sAF1, sAF3, lAF1, and lAF3. Five volunteers underwent additional measurements using a 10 mm slice thickness and with AF1. Median signal values in the liver were used to determine the biexponential IVIM parameters. Statistical significances were assessed using the Kruskal-Wallis test, Wilcoxon signed-rank test, and Student's t-test. In-silico investigations were also used to interpret the data. RESULTS: There were no significant differences between the biexponential IVIM parameters acquired from sAF1, sAF3, lAF1, and lAF3. Median values of the perfusion fraction f were as follows: 29.9% (sAF1), 26.9% (sAF3), 28.1% (lAF1), and 27.5% (lAF3). In the 10 mm-thick slices, f decreased from 31.3% (lAF1) to 27.4% (sAF1) (p = 0.141). CONCLUSION: The slice excitation mode did not appear to have any significant influence on the biexponential IVIM parameters. However, our simulations, as well as values reported from previous publications, show that slice thickness, slice gaps, and slice order are relevant and should thus be reported in IVIM studies.


Subject(s)
Diffusion Magnetic Resonance Imaging , Liver , Humans , Adult , Liver/diagnostic imaging , Male , Female , Young Adult , Diffusion Magnetic Resonance Imaging/methods , Motion , Image Processing, Computer-Assisted/methods , Healthy Volunteers
5.
Tomography ; 10(5): 773-788, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38787019

ABSTRACT

Background: The purpose of this study was to investigate the dependence of Intravoxel Incoherent Motion (IVIM) parameters measured in the human calf on B0. Methods: Diffusion-weighted image data of eight healthy volunteers were acquired using five b-values (0-600 s/mm2) at rest and after muscle activation at 0.55 and 7 T. The musculus gastrocnemius mediale (GM, activated) was assessed. The perfusion fraction f and diffusion coefficient D were determined using segmented fits. The dependence on field strength was assessed using Student's t-test for paired samples and the Wilcoxon signed-rank test. A biophysical model built on the three non-exchanging compartments of muscle, venous blood, and arterial blood was used to interpret the data using literature relaxation times. Results: The measured perfusion fraction of the GM was significantly lower at 7 T, both for the baseline measurement and after muscle activation. For 0.55 and 7 T, the mean f values were 7.59% and 3.63% at rest, and 14.03% and 6.92% after activation, respectively. The biophysical model estimations for the mean proton-density-weighted perfusion fraction were 3.37% and 6.50% for the non-activated and activated states, respectively. Conclusions: B0 may have a significant effect on the measured IVIM parameters. The blood relaxation times suggest that 7 T IVIM may be arterial-weighted whereas 0.55 T IVIM may exhibit an approximately equal weighting of arterial and venous blood.


Subject(s)
Diffusion Magnetic Resonance Imaging , Muscle, Skeletal , Humans , Diffusion Magnetic Resonance Imaging/methods , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/physiology , Male , Adult , Female , Leg/diagnostic imaging , Leg/blood supply , Magnetic Fields , Motion , Healthy Volunteers , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL