Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Pediatr Res ; 93(6): 1701-1709, 2023 05.
Article in English | MEDLINE | ID: mdl-36075989

ABSTRACT

BACKGROUND: Are thermoregulation and golden hour practices in extremely preterm (EP) infants comparable across the world? This study aims to describe these practices for EP infants based on the neonatal intensive care unit's (NICUs) geographic region, country's income status and the lowest gestational age (GA) of infants resuscitated. METHODS: The Director of each NICU was requested to complete the e-questionnaire between February 2019 and August 2021. RESULTS: We received 848 responses, from all geographic regions and resource settings. Variations in most thermoregulation and golden hour practices were observed. Using a polyethylene plastic wrap, commencing humidity within 60 min of admission, and having local protocols were the most consistent practices (>75%). The odds for the following practices differed in NICUs resuscitating infants from 22 to 23 weeks GA compared to those resuscitating from 24 to 25 weeks: respiratory support during resuscitation and transport, use of polyethylene plastic wrap and servo-control mode, commencing ambient humidity >80% and presence of local protocols. CONCLUSION: Evidence-based practices on thermoregulation and golden hour stabilisation differed based on the unit's region, country's income status and the lowest GA of infants resuscitated. Future efforts should address reducing variation in practice and aligning practices with international guidelines. IMPACT: A wide variation in thermoregulation and golden hour practices exists depending on the income status, geographic region and lowest gestation age of infants resuscitated. Using a polyethylene plastic wrap, commencing humidity within 60 min of admission and having local protocols were the most consistent practices. This study provides a comprehensive description of thermoregulation and golden hour practices to allow a global comparison in the delivery of best evidence-based practice. The findings of this survey highlight a need for reducing variation in practice and aligning practices with international guidelines for a comparable health care delivery.


Subject(s)
Hypothermia , Infant, Extremely Premature , Female , Humans , Infant, Newborn , Male , Pregnancy , Body Temperature Regulation , Hypothermia/prevention & control , Intensive Care Units, Neonatal , Polyethylenes , Surveys and Questionnaires
2.
Pediatr Radiol ; 53(11): 2235-2244, 2023 10.
Article in English | MEDLINE | ID: mdl-37490126

ABSTRACT

BACKGROUND: Controversy exists regarding the use of a radiopaque agent to identify peripherally inserted central catheter (PICC) tip positions in newborn infants and of serial radiography to monitor PICC tip migration. OBJECTIVE: To investigate the roles of (1) the injection of a radiopaque agent to identify PICC tip position and (2) the performance of weekly radiography to monitor PICC migration. MATERIALS AND METHODS: This retrospective single-centre cohort study included newborn infants who received a PICC between 1 January 2016 and 31 December 2020. A radiopaque agent was injected to identify PICC tip position and radiographs were performed weekly to detect PICC migration. RESULTS: We identified 676 PICC episodes in 601 infants. A radiopaque agent was used for 590 of these episodes. There was no difference in the proportion of central PICC tip positions based on radiopaque agent use status (490/590, 83% for the radiopaque agent used group versus 73/85, 85.8% for the radiopaque agent not used group, P=0.51). Irrespective of the site of PICC insertion, outward migration was observed for most centrally placed PICCs over their entire in situ duration. Inward migration was identified in 23 out of 643 PICC episodes (3.6%) only on radiographs obtained on or before day 7. Based on serial radiographs, the odds for PICC tips remaining in a central position were lower the longer the PICC remained in situ (adjusted odds ratio-OR 0.93; 95% confidence interval 0.92-0.95). There was no difference in PICC migration between side and limb of insertion. CONCLUSION: PICC tips can be identified without injection of a radiopaque agent. Serial radiographs identified PICC migration over the in situ duration. This study has implications for reducing exposure to a radiopaque agent and ongoing migration surveillance practices.


Subject(s)
Catheterization, Central Venous , Catheterization, Peripheral , Central Venous Catheters , Infant, Newborn , Humans , Infant , Retrospective Studies , Cohort Studies , Radiography , Contrast Media , Catheters
3.
J Pediatr ; 235: 75-82.e1, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33857466

ABSTRACT

OBJECTIVES: To evaluate cerebral tissue oxygenation (cTOI) and cerebral perfusion in preterm infants in supine vs prone positions. STUDY DESIGN: Sixty preterm infants, born before 32 weeks of gestation, were enrolled; 30 had bronchopulmonary dysplasia (BPD, defined as the need for respiratory support and/or supplemental oxygen at 36 weeks of postmenstrual age). Cerebral perfusion, cTOI, and polysomnography were measured in both the supine and prone position with the initial position being randomized. Infants with a major intraventricular hemorrhage or major congenital abnormality were excluded. RESULTS: Cerebral perfusion was unaffected by position or BPD status. In the BPD group, the mean cTOI was higher in the prone position compared with the supine position by a difference of 3.27% (P = .03; 95% CI 6.28-0.25) with no difference seen in the no-BPD group. For the BPD group, the burden of cerebral hypoxemia (cumulative time spent with cTOI <55%) was significantly lower in the prone position (23%) compared with the supine position (29%) (P < .001). In those without BPD, position had no effect on cTOI. CONCLUSIONS: In preterm infants with BPD, the prone position improved cerebral oxygenation and reduced cerebral hypoxemia. These findings may have implications for positioning practices. Further research will establish the impact of position on short- and long-term developmental outcomes.


Subject(s)
Brain/metabolism , Cerebrovascular Circulation/physiology , Infant, Premature/physiology , Oxygen/metabolism , Prone Position/physiology , Supine Position/physiology , Bronchopulmonary Dysplasia/physiopathology , Bronchopulmonary Dysplasia/therapy , Continuous Positive Airway Pressure , Cross-Over Studies , Humans , Hypoxia, Brain/physiopathology , Hypoxia, Brain/prevention & control , Infant, Newborn , Intensive Care Units, Neonatal , Oxygen Inhalation Therapy , Prospective Studies
4.
J Paediatr Child Health ; 57(10): 1627-1633, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34145664

ABSTRACT

AIM: To investigate skincare practices in the first 2 weeks of life in extremely premature infants across tertiary neonatal intensive care units (NICUs). METHODS: A web-based secure survey invite was emailed to the medical directors of tertiary NICUs. The survey included questions on various aspects of skincare practices in the first 2 weeks of life in extremely premature infants (born before 28 weeks gestation). The person most familiar with local skincare practices was asked to complete the survey and only one response per unit was requested. We performed a descriptive analysis. RESULTS: We received responses from 30 out of 32 NICUs (response rate 93%). Twenty-five NICUs (89%) reported offering resuscitation and intensive care to infants born at ≥23 weeks gestation. All NICUs reported occurrences of skin breakdown, including medical adhesive-related skin injury (30%), abrasion/friction-associated skin injury (46%), perineal skin breakdown (55%), pressure site injury (47%) and diaper dermatitis (60%). A high level of consensus (≥75%) was observed for certain practices, such as the use of polyethylene occlusive plastic wraps at birth and aqueous chlorhexidine solution for sterile procedures, but a low level of consensus (<25%) was observed for many other practices, including the skin risk assessment tool used. CONCLUSIONS: Skin injuries in extremely premature infants are common and skincare practices vary considerably amongst NICUs. Clinical practice improvement projects and further clinical research will help improve consistency amongst NICUs. Further research is needed to assist the development of evidence-based guidelines and benchmarking for skincare practices in these vulnerable infants.


Subject(s)
Infant, Extremely Premature , Intensive Care Units, Neonatal , Australia , Humans , Infant, Newborn , New Zealand , Surveys and Questionnaires
5.
Vox Sang ; 115(8): 712-721, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32424842

ABSTRACT

BACKGROUND AND OBJECTIVES: In anaemic preterm infants who receive packed red blood cell (PRBC) transfusions, changes to mesenteric tissue oxygenation and perfusion have been reported using a restrictive haemoglobin (Hb)-based threshold. We aimed to investigate changes to hepatic tissue oxygenation and abdominal blood flow after PRBC transfusion and its association with enteral feeding using a liberal Hb threshold (as shown inTable1). [Table: see text] MATERIAL AND METHODS: We prospectively studied a cohort of preterm infants born at < 32 weeks' gestation who received at least one PRBC transfusion and monitored them immediately before (Time 1), immediately after (Time 2) and 24 hours after transfusion (Time 3). Data obtained included physiological parameters, the hepatic tissue oxygenation index and pulsed Doppler ultrasound measurements in the abdominal arterial circulation. Additionally, the effects of withholding enteral feeds were investigated. RESULTS: We monitored 50 PRBC transfusion episodes in 40 preterm infants, in whom the mean gestational age was 26.72 weeks (±1.6 weeks) and the mean birth weight was 855.25 g (±190.7 g). We observed significant changes to pulsed Doppler measurements in abdominal arterial circulation (coeliac artery mean peak systolic velocity Time 2 [75.08 cm/sec] versus Time 3 [71.13 cm/sec]; mean end-diastolic velocity Time 2 [15.71 cm/sec] versus Time 3 [13.76 cm/sec]; mean resistive index Time 2 0.78 versus Time 3 0.80, right renal artery mean peak systolic velocity Time 1 58.28 cm/sec versus Time 2 50.97 cm/sec, left renal artery mean peak systolic velocity Time 1 49.20 cm/sec versus Time 2 45.40 cm/sec), but not to hepatic tissue oxygenation after PRBC transfusion (Time 1 mean 53.66 [SD, 13.34]; Time 2 mean 54.93 [SD, 9.3]; Time 3 mean 55.64 [SD, 12.86]). There were no changes to hepatic tissue oxygenation or mesenteric blood flow from withholding enteral feeds during PRBC transfusion. There were no local adverse effects from hepatic tissue oxygenation monitoring. CONCLUSION: In mildly anaemic preterm infants, when allowing a liberal Hb threshold-based trigger for PRBC transfusion, changes in abdominal arterial circulation were present, but not in hepatic tissue oxygenation. Withholding enteral feeds during PRBC transfusion had no impact on hepatic tissue oxygenation or mesenteric flows.


Subject(s)
Abdomen , Anemia/therapy , Enteral Nutrition , Erythrocyte Transfusion/adverse effects , Liver/metabolism , Oxygen/analysis , Anemia/metabolism , Female , Humans , Infant, Newborn , Infant, Premature , Male , Perfusion , Prospective Studies
6.
Transfusion ; 59(10): 3093-3101, 2019 10.
Article in English | MEDLINE | ID: mdl-31313334

ABSTRACT

BACKGROUND: Red blood cell (RBC) transfusion is a standard treatment for anemia of prematurity. Cerebral tissue oxygenation and blood flow velocities improve when a restrictive transfusion threshold is followed, but little is known about the effect of practicing a liberal transfusion threshold on cerebral tissue oxygenation, cerebral blood flow velocities, and cardiac output measurements. STUDY DESIGN AND METHODS: A prospective observational study of preterm infants under 32 weeks' gestation who received RBC transfusion. Monitoring was performed immediately before, immediately after, and 24 hours after transfusion. Data obtained included physiologic parameters, cerebral tissue oxygenation index (TOI), anterior and middle cerebral artery pulsed Doppler ultrasound measurements, and cardiac output measurements. Data were analyzed using analysis of variance for repeated measures. RESULTS: Fifty RBC transfusion episodes in 40 preterm infants were monitored. The mean gestational age was 26.72 weeks (±1.6 weeks), and the mean birth weight was 855.25 g (±190.7 g). We did not observe significant changes in cerebral TOI (pretransfusion mean TOI = 70.5 [11.54], immediately after transfusion = 71.38 [12.51], [p = 0.924; 95% confidence interval (CI), -4.64 to 6.39], and 24 hours after transfusion = 75.64 [14.4]; [p = 0.07; 95% CI, -0.37 to 10.65]), cerebral fractional tissue oxygen extraction (pretransfusion = 0.25 [0.12], immediately after transfusion = 0.24 [0.13], and 24 hours after transfusion = 0.20 [0.15]), cerebral resistive index, cerebral pulsatility index, or right ventricular output. Statistically significant changes were observed immediately after transfusion in peak systolic velocity, end-diastolic velocity and time-averaged maximum velocity in the cerebral arterial circulation. Left ventricular output (pretransfusion = 374.32 mL/kg/min, immediately after transfusion = 346.67 mL/kg/min [p = 0.000; 95% CI, -39.61 to -15.68], and 24 hours after transfusion = 361.17 mL/kg/min [p = 0.027; 95% CI, -25.11 to -1.18]) and heart rate (pretransfusion = 163.37 [9.49], immediately after transfusion = 157.29 [10.2] [p = 0.000; 95% CI, -8.96 to -3.20], and 24 hours after transfusion = 160.40 [10.4] [p = 0.041; 95% CI, -5.85 to -0.09]) showed statistically significant changes throughout the monitoring period. CONCLUSION: Our findings show that practicing liberal transfusion thresholds did not improve cerebral TOI in preterm infants who have mild anemia, but it did improve the compensatory response in cerebral arterial blood flow and cardiac output.


Subject(s)
Cardiac Output , Cerebral Arteries , Cerebrovascular Circulation , Erythrocyte Transfusion , Hemoglobins/metabolism , Ultrasonography, Doppler, Pulsed , Cerebral Arteries/diagnostic imaging , Cerebral Arteries/metabolism , Cerebral Arteries/physiopathology , Female , Humans , Infant, Newborn , Infant, Premature , Male , Prospective Studies
7.
Article in English | MEDLINE | ID: mdl-38336472

ABSTRACT

BACKGROUND: Respiratory function monitors (RFMs) have been used extensively in manikin and infant studies yet have not become the standard of training. We report the outcomes of a new portable, lightweight RFM, the Juno, designed to show mask leak and deflation tidal volume to assist in positive pressure ventilation (PPV) competency training using manikins. METHODS: Two leak-free manikins (preterm and term) were used. Participants provided PPV to manikins using two randomised devices, self-inflating bag (SIB) and T-piece resuscitator (TPR), with Juno display initially blinded then unblinded in four 90 s paired sequences, aiming for adequate chest wall rise and target minimal mask leak with appropriate target delivered volume when using the monitor. RESULTS: 49 experienced neonatal staff delivered 15 569 inflations to the term manikin and 14 580 inflations to the preterm. Comparing blinded to unblinded RFM display, there were significant reductions in all groups in the number of inflations out of target range volumes (preterm: SIB 22.6-6.6%, TPR 7.1-4.2% and term: SIB 54.8-37.8%, TPR 67.2-63.8%). The percentage of mask leak inflations >60% was reduced in preterm: SIB 20.7-7.2%, TPR 23.4-7.4% and in term: SIB 8.7-3.6%, TPR 23.5-6.2%). CONCLUSIONS: Using the Juno monitor during simulated resuscitation significantly improved mask leak and delivered ventilation among otherwise experienced staff using preterm and term manikins. The Juno is a novel RFM that may assist in teaching and self-assessment of resuscitation PPV technique.

8.
World J Pediatr ; 19(2): 139-157, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36372868

ABSTRACT

BACKGROUND: Globally, are skincare practices and skin injuries in extremely preterm infants comparable? This study describes skin injuries, variation in skincare practices and investigates any association between them. METHODS: A web-based survey was conducted between February 2019 and August 2021. Quantifying skin injuries and describing skincare practices in extremely preterm infants were the main outcomes. The association between skin injuries and skincare practices was established using binary multivariable logistic regression adjusted for regions. RESULTS: Responses from 848 neonatal intensive care units, representing all geographic regions and income status groups were received. Diaper dermatitis (331/840, 39%) and medical adhesive-related skin injuries (319/838, 38%) were the most common injuries. Following a local skincare guideline reduced skin injuries [medical adhesive-related injuries: adjusted odds ratios (aOR) = 0.63, 95% confidence interval (CI) = 0.45-0.88; perineal injuries: aOR = 0.66, 95% CI = 0.45-0.96; local skin infections: OR = 0.41, 95% CI = 0.26-0.65; chemical burns: OR = 0.46, 95% CI = 0.26-0.83; thermal burns: OR = 0.51, 95% CI = 0.27-0.96]. Performing skin assessments at least every four hours reduced skin injuries (abrasion: aOR = 0.48, 95% CI = 0.33-0.67; pressure: aOR = 0.51, 95% CI = 0.34-0.78; diaper dermatitis: aOR = 0.71, 95% CI = 0.51-0.99; perineal: aOR = 0.52, 95% CI = 0.36-0.75). Regional and resource settings-based variations in skin injuries and skincare practices were observed. CONCLUSIONS: Skin injuries were common in extremely preterm infants. Consistency in practice and improved surveillance appears to reduce the occurrence of these injuries. Better evidence regarding optimal practices is needed to reduce skin injuries and minimize practice variations.


Subject(s)
Dermatitis , Infant, Extremely Premature , Infant , Infant, Newborn , Humans , Intensive Care Units, Neonatal , Skin Care , Logistic Models
9.
Arch Dis Child Fetal Neonatal Ed ; 103(3): F271-F276, 2018 May.
Article in English | MEDLINE | ID: mdl-28802261

ABSTRACT

BACKGROUND: International neonatal resuscitation guidelines recommend the use of laryngeal mask airway (LMA) with newborn infants (≥34 weeks' gestation or >2 kg weight) when bag-mask ventilation (BMV) or tracheal intubation is unsuccessful. Previous publications do not allow broad LMA device comparison. OBJECTIVE: To compare delivered ventilation of seven brands of size 1 LMA devices with two brands of face mask using self-inflating bag (SIB). DESIGN: 40 experienced neonatal staff provided inflation cycles using SIB with positive end expiratory pressure (PEEP) (5 cmH2O) to a specialised newborn/infant training manikin randomised for each LMA and face mask. All subjects received prior education in LMA insertion and BMV. RESULTS: 12 415 recorded inflations for LMAs and face masks were analysed. Leak detected was lowest with i-gel brand, with a mean of 5.7% compared with face mask (triangular 42.7, round 35.7) and other LMAs (45.5-65.4) (p<0.001). Peak inspiratory pressure was higher with i-gel, with a mean of 28.9 cmH2O compared with face mask (triangular 22.8, round 25.8) and other LMAs (14.3-22.0) (p<0.001). PEEP was higher with i-gel, with a mean of 5.1 cmH2O compared with face mask (triangular 3.0, round 3.6) and other LMAs (0.6-2.6) (p<0.001). In contrast to other LMAs examined, i-gel had no insertion failures and all users found i-gel easy to use. CONCLUSION: This study has shown dramatic performance differences in delivered ventilation, mask leak and ease of use among seven different brands of LMA tested in a manikin model. This coupled with no partial or complete insertion failures and ease of use suggests i-gel LMA may have an expanded role with newborn resuscitation as a primary resuscitation device.


Subject(s)
Cardiopulmonary Resuscitation/instrumentation , Intubation, Intratracheal/instrumentation , Laryngeal Masks , Positive-Pressure Respiration/instrumentation , Cross-Over Studies , Humans , Infant , Infant, Newborn , Intubation, Intratracheal/adverse effects , Manikins , Positive-Pressure Respiration/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL