Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
J Infect Dis ; 223(10): 1671-1676, 2021 05 28.
Article in English | MEDLINE | ID: mdl-33675366

ABSTRACT

It is currently unknown how post-COVID-19 syndrome (PCS) may affect those infected with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). This longitudinal study includes healthcare staff who tested positive for SARS-CoV-2 between March and April 2020, with follow-up of their antibody titers and symptoms. More than half (21 of 38) had PCS after 7-8 months. There was no statistically significant difference between initial reverse-transcription polymerase chain reaction titers or serial antibody levels between those who did and those who did not develop PCS. This study highlights the relative commonality of PCS in healthcare workers and this should be considered in vaccination scheduling and workforce planning to allow adequate frontline staffing numbers.


Subject(s)
Antibodies, Viral/biosynthesis , COVID-19/complications , Health Personnel , SARS-CoV-2/immunology , Adult , Aged , Anosmia , COVID-19/immunology , Cohort Studies , Fatigue , Female , Headache , Humans , Longitudinal Studies , Male , Middle Aged , Nasopharynx/virology , Respiratory Tract Diseases , Surveys and Questionnaires , Syndrome , United Kingdom , Young Adult
2.
Kidney Int ; 99(6): 1470-1477, 2021 06.
Article in English | MEDLINE | ID: mdl-33774082

ABSTRACT

Patients with end stage kidney disease receiving in-center hemodialysis (ICHD) have had high rates of SARS-CoV-2 infection. Following infection, patients receiving ICHD frequently develop circulating antibodies to SARS-CoV-2, even with asymptomatic infection. Here, we investigated the durability and functionality of the immune responses to SARS-CoV-2 infection in patients receiving ICHD. Three hundred and fifty-six such patients were longitudinally screened for SARS-CoV-2 antibodies and underwent routine PCR-testing for symptomatic and asymptomatic infection. Patients were regularly screened for nucleocapsid protein (anti-NP) and receptor binding domain (anti-RBD) antibodies, and those who became seronegative at six months were screened for SARS-CoV-2 specific T-cell responses. One hundred and twenty-nine (36.2%) patients had detectable antibody to anti-NP at time zero, of whom 127 also had detectable anti-RBD. Significantly, at six months, 71/111 (64.0%) and 99/116 (85.3%) remained anti-NP and anti-RBD seropositive, respectively. For patients who retained antibody, both anti-NP and anti-RBD levels were reduced significantly after six months. Eleven patients who were anti-NP seropositive at time zero, had no detectable antibody at six months; of whom eight were found to have SARS-CoV-2 antigen specific T cell responses. Independent of antibody status at six months, patients with baseline positive SARS-CoV-2 serology were significantly less likely to have PCR confirmed infection over the following six months. Thus, patients receiving ICHD mount durable immune responses six months post SARS-CoV-2 infection, with fewer than 3% of patients showing no evidence of humoral or cellular immunity.


Subject(s)
Antibodies, Viral/analysis , COVID-19/immunology , Kidney Failure, Chronic/therapy , Renal Dialysis/adverse effects , SARS-CoV-2/immunology , COVID-19 Testing , Female , Humans , Immunity , Male , Pandemics , Polymerase Chain Reaction , Reinfection , SARS-CoV-2/isolation & purification , Serologic Tests/methods
4.
Front Immunol ; 14: 1146702, 2023.
Article in English | MEDLINE | ID: mdl-37056776

ABSTRACT

The SARS-CoV-2 pandemic enables the analysis of immune responses induced against a novel coronavirus infecting immunologically naïve individuals. This provides an opportunity for analysis of immune responses and associations with age, sex and disease severity. Here we measured an array of solid-phase binding antibody and viral neutralising Ab (nAb) responses in participants (n=337) of the ISARIC4C cohort and characterised their correlation with peak disease severity during acute infection and early convalescence. Overall, the responses in a Double Antigen Binding Assay (DABA) for antibody to the receptor binding domain (anti-RBD) correlated well with IgM as well as IgG responses against viral spike, S1 and nucleocapsid protein (NP) antigens. DABA reactivity also correlated with nAb. As we and others reported previously, there is greater risk of severe disease and death in older men, whilst the sex ratio was found to be equal within each severity grouping in younger people. In older males with severe disease (mean age 68 years), peak antibody levels were found to be delayed by one to two weeks compared with women, and nAb responses were delayed further. Additionally, we demonstrated that solid-phase binding antibody responses reached higher levels in males as measured via DABA and IgM binding against Spike, NP and S1 antigens. In contrast, this was not observed for nAb responses. When measuring SARS-CoV-2 RNA transcripts (as a surrogate for viral shedding) in nasal swabs at recruitment, we saw no significant differences by sex or disease severity status. However, we have shown higher antibody levels associated with low nasal viral RNA indicating a role of antibody responses in controlling viral replication and shedding in the upper airway. In this study, we have shown discernible differences in the humoral immune responses between males and females and these differences associate with age as well as with resultant disease severity.


Subject(s)
COVID-19 , Male , Humans , Female , Aged , SARS-CoV-2 , Prospective Studies , Antibody Formation , RNA, Viral , Antibodies, Viral , Nucleocapsid Proteins , Hospitals , Patient Acuity , Immunoglobulin M
5.
Sci Rep ; 12(1): 1885, 2022 02 03.
Article in English | MEDLINE | ID: mdl-35115570

ABSTRACT

At-home sampling is key to large scale seroprevalence studies. Dried blood spot (DBS) self-sampling removes the need for medical personnel for specimen collection but facilitates specimen referral to an appropriately accredited laboratory for accurate sample analysis. To establish a highly sensitive and specific antibody assay that would facilitate self-sampling for prevalence and vaccine-response studies. Paired sera and DBS eluates collected from 439 sero-positive, 382 sero-negative individuals and DBS from 34 vaccine recipients were assayed by capture ELISAs for IgG and IgM antibody to SARS-CoV-2. IgG and IgM combined on DBS eluates achieved a diagnostic sensitivity of 97.9% (95%CI 96.6 to 99.3) and a specificity of 99.2% (95% CI 98.4 to 100) compared to serum, displaying limits of detection equivalent to 23 and 10 WHO IU/ml, respectively. A strong correlation (r = 0.81) was observed between serum and DBS reactivities. Reactivity remained stable with samples deliberately rendered inadequate, (p = 0.234) and when samples were accidentally damaged or 'invalid'. All vaccine recipients were sero-positive. This assay provides a secure method for self-sampling by DBS with a sensitivity comparable to serum. The feasibility of DBS testing in sero-prevalence studies and in monitoring post-vaccine responses was confirmed, offering a robust and reliable tool for serological monitoring at a population level.


Subject(s)
Antibodies, Viral/blood , COVID-19 Testing/methods , COVID-19/diagnosis , COVID-19/epidemiology , Dried Blood Spot Testing/methods , Immunoglobulin G/blood , Immunoglobulin M/blood , SARS-CoV-2/immunology , Specimen Handling/methods , Biomarkers/blood , COVID-19/immunology , COVID-19/virology , COVID-19 Vaccines/immunology , Feasibility Studies , Female , Humans , Male , Sensitivity and Specificity , Seroepidemiologic Studies
6.
J Virol Methods ; 302: 114475, 2022 04.
Article in English | MEDLINE | ID: mdl-35077719

ABSTRACT

Accurate and sensitive detection of antibody to SARS-CoV-2 remains an essential component of the pandemic response. Measuring antibody that predicts neutralising activity and the vaccine response is an absolute requirement for laboratory-based confirmatory and reference activity. The viral receptor binding domain (RBD) constitutes the prime target antigen for neutralising antibody. A double antigen binding assay (DABA), providing the most sensitive format has been exploited in a novel hybrid manner employing a solid-phase S1 preferentially presenting RBD, coupled with a labelled RBD conjugate, used in a two-step sequential assay for detection and measurement of antibody to RBD (anti-RBD). This class and species neutral assay showed a specificity of 100 % on 825 pre COVID-19 samples and a potential sensitivity of 99.6 % on 276 recovery samples, predicting quantitatively the presence of neutralising antibody determined by pseudo-type neutralization and by plaque reduction. Anti-RBD is also measurable in ferrets immunised with ChadOx1 nCoV-19 vaccine and in humans immunised with both AstraZeneca and Pfizer vaccines. This assay detects anti-RBD at presentation with illness, demonstrates its elevation with disease severity, its sequel to asymptomatic infection and its persistence after the loss of antibody to the nucleoprotein (anti-NP). It also provides serological confirmation of prior infection and offers a secure measure for seroprevalence and studies of vaccine immunisation in human and animal populations. The hybrid DABA also displays the attributes necessary for the detection and quantification of anti-RBD to be used in clinical practice. An absence of detectable anti-RBD by this assay predicates the need for passive immune prophylaxis in at-risk patients.


Subject(s)
Antibodies, Viral/isolation & purification , COVID-19 , SARS-CoV-2 , Spike Glycoprotein, Coronavirus/immunology , Animals , Antibodies, Neutralizing/isolation & purification , COVID-19/diagnosis , ChAdOx1 nCoV-19 , Ferrets , Humans , RNA, Viral , Seroepidemiologic Studies
7.
BMJ ; 372: n423, 2021 03 02.
Article in English | MEDLINE | ID: mdl-33653694

ABSTRACT

OBJECTIVE: To evaluate the performance of new lateral flow immunoassays (LFIAs) suitable for use in a national coronavirus disease 2019 (covid-19) seroprevalence programme (real time assessment of community transmission 2-React 2). DESIGN: Diagnostic accuracy study. SETTING: Laboratory analyses were performed in the United Kingdom at Imperial College, London and university facilities in London. Research clinics for finger prick sampling were run in two affiliated NHS trusts. PARTICIPANTS: Sensitivity analyses were performed on sera stored from 320 previous participants in the React 2 programme with confirmed previous severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. Specificity analyses were performed on 1000 prepandemic serum samples. 100 new participants with confirmed previous SARS-CoV-2 infection attended study clinics for finger prick testing. INTERVENTIONS: Laboratory sensitivity and specificity analyses were performed for seven LFIAs on a minimum of 200 serum samples from participants with confirmed SARS-CoV-2 infection and 500 prepandemic serum samples, respectively. Three LFIAs were found to have a laboratory sensitivity superior to the finger prick sensitivity of the LFIA currently used in React 2 seroprevalence studies (84%). These LFIAs were then further evaluated through finger prick testing on participants with confirmed previous SARS-CoV-2 infection: two LFIAs (Surescreen, Panbio) were evaluated in clinics in June-July 2020 and the third LFIA (AbC-19) in September 2020. A spike protein enzyme linked immunoassay and hybrid double antigen binding assay were used as laboratory reference standards. MAIN OUTCOME MEASURES: The accuracy of LFIAs in detecting immunoglobulin G (IgG) antibodies to SARS-CoV-2 compared with two reference standards. RESULTS: The sensitivity and specificity of seven new LFIAs that were analysed using sera varied from 69% to 100%, and from 98.6% to 100%, respectively (compared with the two reference standards). Sensitivity on finger prick testing was 77% (95% confidence interval 61.4% to 88.2%) for Panbio, 86% (72.7% to 94.8%) for Surescreen, and 69% (53.8% to 81.3%) for AbC-19 compared with the reference standards. Sensitivity for sera from matched clinical samples performed on AbC-19 was significantly higher with serum than finger prick at 92% (80.0% to 97.7%, P=0.01). Antibody titres varied considerably among cohorts. The numbers of positive samples identified by finger prick in the lowest antibody titre quarter varied among LFIAs. CONCLUSIONS: One new LFIA was identified with clinical performance suitable for potential inclusion in seroprevalence studies. However, none of the LFIAs tested had clearly superior performance to the LFIA currently used in React 2 seroprevalence surveys, and none showed sufficient sensitivity and specificity to be considered for routine clinical use.


Subject(s)
COVID-19 Serological Testing , COVID-19/diagnosis , Immunoassay , SARS-CoV-2/isolation & purification , Adult , Antibodies, Viral/blood , COVID-19/blood , COVID-19/epidemiology , Female , Humans , Male , Middle Aged , SARS-CoV-2/immunology , Sensitivity and Specificity , Seroepidemiologic Studies , United Kingdom
SELECTION OF CITATIONS
SEARCH DETAIL