Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Eur Radiol ; 2023 Nov 08.
Article in English | MEDLINE | ID: mdl-37935847

ABSTRACT

OBJECTIVES: Percutaneous image-guided tumor ablation of liver malignancies has become an indispensable therapeutic procedure. The aim of this evaluation of the prospectively managed multinational registry of the voluntary German Society for Interventional Radiology and Minimally Invasive Therapy (DeGIR) was to analyze its use, technical success, and complications in clinical practice. MATERIALS AND METHODS: All liver tumor ablations from 2018 to 2022 were included. Technical success was defined as complete ablation of the tumor with an ablative margin. RESULTS: A total of 7228 liver tumor ablations from 136 centers in Germany and Austria were analyzed. In total, 31.4% (2268/7228) of patients were female. Median age was 67 years (IQR 58-74 years). Microwave ablation (MWA) was performed in 65.1% (4703/7228), and radiofrequency ablation (RFA) in 32.7% (2361/7228). Of 5229 cases with reported tumor etiology, 60.3% (3152/5229) of ablations were performed for liver metastases and 37.3% (1950/5229) for hepatocellular carcinoma. The median lesion diameter was 19 mm (IQR 12-27 mm). In total, 91.8% (6636/7228) of ablations were technically successful. The rate of technically successful ablations was significantly higher in MWA (93.9%, 4417/4703) than in RFA (87.3%, 2061/2361) (p < 0.0001). The total complication rate was 3.0% (214/7228) and was significantly higher in MWA (4.0%, 189/4703) than in RFA (0.9%, 21/2361, p < 0.0001). Additional needle track ablation did not increase the rate of major complications significantly (24.8% (33/133) vs. 28.4% (23/81), p = 0.56)). CONCLUSION: MWA is the most frequent ablation method. Percutaneous image-guided liver tumor ablations have a high technical success rate, which is higher for MWA than RFA. The complication rate is generally low but is higher for MWA than RFA. CLINICAL RELEVANCE STATEMENT: Percutaneous image-guided liver ablation using microwave ablation and radiofrequency ablation are effective therapeutic procedures with low complication rates for the treatment of primary and secondary liver malignancies. KEY POINTS: • Percutaneous image-guided liver tumor ablations have a high technical success rate, which is higher for microwave ablation than radiofrequency ablation. • Microwave ablation is the most frequent ablation method ahead of radiofrequency ablation. • The complication rate is generally low but is higher for microwave ablation than radiofrequency ablation.

3.
Sci Rep ; 14(1): 1172, 2024 01 12.
Article in English | MEDLINE | ID: mdl-38216664

ABSTRACT

A novel software, DiffTool, was developed in-house to keep track of changes made by board-certified radiologists to preliminary reports created by residents and evaluate its impact on radiological hands-on training. Before (t0) and after (t2-4) the deployment of the software, 18 residents (median age: 29 years; 33% female) completed a standardized questionnaire on professional training. At t2-4 the participants were also requested to respond to three additional questions to evaluate the software. Responses were recorded via a six-point Likert scale ranging from 1 ("strongly agree") to 6 ("strongly disagree"). Prior to the release of the software, 39% (7/18) of the residents strongly agreed with the statement that they manually tracked changes made by board-certified radiologists to each of their radiological reports while 61% were less inclined to agree with that statement. At t2-4, 61% (11/18) stated that they used DiffTool to track differences. Furthermore, we observed an increase from 33% (6/18) to 44% (8/18) of residents who agreed to the statement "I profit from every corrected report". The DiffTool was well accepted among residents with a regular user base of 72% (13/18), while 78% (14/18) considered it a relevant improvement to their training. The results of this study demonstrate the importance of providing a time-efficient way to analyze changes made to preliminary reports as an additive for professional training.


Subject(s)
Internship and Residency , Radiology , Humans , Female , Adult , Male , Radiography , Software , Radiologists
4.
Eur Radiol Exp ; 8(1): 105, 2024 Sep 19.
Article in English | MEDLINE | ID: mdl-39298080

ABSTRACT

BACKGROUND: Regular disease monitoring with low-dose high-resolution (LD-HR) computed tomography (CT) scans is necessary for the clinical management of people with cystic fibrosis (pwCF). The aim of this study was to compare the image quality and radiation dose of LD-HR protocols between photon-counting CT (PCCT) and energy-integrating detector system CT (EID-CT) in pwCF. METHODS: This retrospective study included 23 pwCF undergoing LD-HR chest CT with PCCT who had previously undergone LD-HR chest CT with EID-CT. An intraindividual comparison of radiation dose and image quality was conducted. The study measured the dose-length product, volumetric CT dose index, effective dose and signal-to-noise ratio (SNR). Three blinded radiologists assessed the overall image quality, image sharpness, and image noise using a 5-point Likert scale ranging from 1 (deficient) to 5 (very good) for image quality and image sharpness and from 1 (very high) to 5 (very low) for image noise. RESULTS: PCCT used approximately 42% less radiation dose than EID-CT (median effective dose 0.54 versus 0.93 mSv, p < 0.001). PCCT was consistently rated higher than EID-CT for overall image quality and image sharpness. Additionally, image noise was lower with PCCT compared to EID-CT. The average SNR of the lung parenchyma was lower with PCCT compared to EID-CT (p < 0.001). CONCLUSION: In pwCF, LD-HR chest CT protocols using PCCT scans provided significantly better image quality and reduced radiation exposure compared to EID-CT. RELEVANCE STATEMENT: In pwCF, regular follow-up could be performed through photon-counting CT instead of EID-CT, with substantial advantages in terms of both lower radiation exposure and increased image quality. KEY POINTS: Photon-counting CT (PCCT) and energy-integrating detector system CT (EID-CT) were compared in 23 people with cystic fibrosis (pwCF). Image quality was rated higher for PCCT than for EID-CT. PCCT used approximately 42% less radiation dose and offered superior image quality than EID-CT.


Subject(s)
Cystic Fibrosis , Photons , Radiation Dosage , Radiography, Thoracic , Tomography, X-Ray Computed , Cystic Fibrosis/diagnostic imaging , Humans , Retrospective Studies , Tomography, X-Ray Computed/methods , Male , Female , Adult , Radiography, Thoracic/methods , Signal-To-Noise Ratio , Young Adult
5.
Eur Radiol Exp ; 8(1): 114, 2024 Oct 14.
Article in English | MEDLINE | ID: mdl-39400764

ABSTRACT

BACKGROUND: Non-specific interstitial pneumonia (NSIP) is an interstitial lung disease that can result in end-stage fibrosis. We investigated the influence of body composition and pulmonary fat attenuation volume (CTpfav) on overall survival (OS) in NSIP patients. METHODS: In this retrospective single-center study, 71 NSIP patients with a median age of 65 years (interquartile range 21.5), 39 females (55%), who had a computed tomography from August 2009 to February 2018, were included, of whom 38 (54%) died during follow-up. Body composition analysis was performed using an open-source nnU-Net-based framework. Features were combined into: Sarcopenia (muscle/bone); Fat (total adipose tissue/bone); Myosteatosis (inter-/intra-muscular adipose tissue/total adipose tissue); Mediastinal (mediastinal adipose tissue/bone); and Pulmonary fat index (CTpfav/lung volume). Kaplan-Meier analysis with a log-rank test and multivariate Cox regression were used for survival analyses. RESULTS: Patients with a higher (> median) Sarcopenia and lower (< median) Mediastinal Fat index had a significantly better survival probability (2-year survival rate: 83% versus 71% for high versus low Sarcopenia index, p = 0.023; 83% versus 72% for low versus high Mediastinal fat index, p = 0.006). In univariate analysis, individuals with a higher Pulmonary fat index exhibited significantly worse survival probability (2-year survival rate: 61% versus 94% for high versus low, p = 0.003). Additionally, it was an independent risk predictor for death (hazard ratio 2.37, 95% confidence interval 1.03-5.48, p = 0.043). CONCLUSION: Fully automated body composition analysis offers interesting perspectives in patients with NSIP. Pulmonary fat index was an independent predictor of OS. RELEVANCE STATEMENT: The Pulmonary fat index is an independent predictor of OS in patients with NSIP and demonstrates the potential of fully automated, deep-learning-driven body composition analysis as a biomarker for prognosis estimation. KEY POINTS: This is the first study assessing the potential of CT-based body composition analysis in patients with non-specific interstitial pneumonia (NSIP). A single-center analysis of 71 patients with board-certified diagnosis of NSIP is presented Indices related to muscle, mediastinal fat, and pulmonary fat attenuation volume were significantly associated with survival at univariate analysis. CT pulmonary fat attenuation volume, normalized by lung volume, resulted as an independent predictor for death.


Subject(s)
Adipose Tissue , Body Composition , Lung Diseases, Interstitial , Tomography, X-Ray Computed , Humans , Female , Male , Tomography, X-Ray Computed/methods , Aged , Retrospective Studies , Lung Diseases, Interstitial/diagnostic imaging , Lung Diseases, Interstitial/mortality , Adipose Tissue/diagnostic imaging , Middle Aged , Biomarkers , Survival Rate , Lung/diagnostic imaging , Sarcopenia/diagnostic imaging , Sarcopenia/mortality
6.
J Thorac Imaging ; 2024 Aug 26.
Article in English | MEDLINE | ID: mdl-39183570

ABSTRACT

PURPOSE: Idiopathic pulmonary fibrosis (IPF) is the most common interstitial lung disease, with a median survival time of 2 to 5 years. The focus of this study is to establish a novel imaging biomarker. MATERIALS AND METHODS: In this study, 79 patients (19% female) with a median age of 70 years were studied retrospectively. Fully automated body composition analysis (BCA) features (bone, muscle, total adipose tissue, intermuscular, and intramuscular adipose tissue) were combined into Sarcopenia, Fat, and Myosteatosis indices and compared between patients with a survival of more or less than 2 years. In addition, we divided the cohort at the median (high=≥ median, low=

7.
Diagnostics (Basel) ; 14(6)2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38535017

ABSTRACT

Background: This study aimed to evaluate the impact of an AI-assisted fracture detection program on radiology residents' performance in pediatric and adult trauma patients and assess its implications for residency training. Methods: This study, conducted retrospectively, included 200 radiographs from participants aged 1 to 95 years (mean age: 40.7 ± 24.5 years), encompassing various body regions. Among these, 50% (100/200) displayed at least one fracture, totaling one hundred thirty-five fractures, assessed by four radiology residents with different experience levels. A machine learning algorithm was employed for fracture detection, and the ground truth was established by consensus among two experienced senior radiologists. Fracture detection accuracy, reporting time, and confidence were evaluated with and without AI support. Results: Radiology residents' sensitivity for fracture detection improved significantly with AI support (58% without AI vs. 77% with AI, p < 0.001), while specificity showed minor improvements (77% without AI vs. 79% with AI, p = 0.0653). AI stand-alone performance achieved a sensitivity of 93% with a specificity of 77%. AI support for fracture detection significantly reduced interpretation time for radiology residents by an average of approximately 2.6 s (p = 0.0156) and increased resident confidence in the findings (p = 0.0013). Conclusion: AI support significantly enhanced fracture detection sensitivity among radiology residents, particularly benefiting less experienced radiologists. It does not compromise specificity and reduces interpretation time, contributing to improved efficiency. This study underscores AI's potential in radiology, emphasizing its role in training and interpretation improvement.

8.
Neurooncol Adv ; 6(1): vdae022, 2024.
Article in English | MEDLINE | ID: mdl-38516329

ABSTRACT

Background: Primary central nervous system lymphomas (PCNSL) pose a challenge as they may mimic gliomas on magnetic resonance imaging (MRI) imaging, compelling precise differentiation for appropriate treatment. This study focuses on developing an automated MRI-based workflow to distinguish between PCNSL and gliomas. Methods: MRI examinations of 240 therapy-naive patients (141 males and 99 females, mean age: 55.16 years) with cerebral gliomas and PCNSLs (216 gliomas and 24 PCNSLs), each comprising a non-contrast T1-weighted, fluid-attenuated inversion recovery (FLAIR), and contrast-enhanced T1-weighted sequence were included in the study. HD-GLIO, a pre-trained segmentation network, was used to generate segmentations automatically. To validate the segmentation efficiency, 237 manual segmentations were prepared (213 gliomas and 24 PCNSLs). Subsequently, radiomics features were extracted following feature selection and training of an XGBoost algorithm for classification. Results: The segmentation models for gliomas and PCNSLs achieved a mean Sørensen-Dice coefficient of 0.82 and 0.80 for whole tumors, respectively. Three classification models were developed in this study to differentiate gliomas from PCNSLs. The first model differentiated PCNSLs from gliomas, with an area under the curve (AUC) of 0.99 (F1-score: 0.75). The second model discriminated between high-grade gliomas and PCNSLs with an AUC of 0.91 (F1-score: 0.6), and the third model differentiated between low-grade gliomas and PCNSLs with an AUC of 0.95 (F1-score: 0.89). Conclusions: This study serves as a pilot investigation presenting an automated virtual biopsy workflow that distinguishes PCNSLs from cerebral gliomas. Prior to clinical use, it is necessary to validate the results in a prospective multicenter setting with a larger number of PCNSL patients.

9.
Sci Rep ; 13(1): 4336, 2023 03 16.
Article in English | MEDLINE | ID: mdl-36928759

ABSTRACT

The aim of the study was to evaluate the impact of the newly developed Similar patient search (SPS) Web Service, which supports reading complex lung diseases in computed tomography (CT), on the diagnostic accuracy of residents. SPS is an image-based search engine for pre-diagnosed cases along with related clinical reference content ( https://eref.thieme.de ). The reference database was constructed using 13,658 annotated regions of interest (ROIs) from 621 patients, comprising 69 lung diseases. For validation, 50 CT scans were evaluated by five radiology residents without SPS, and three months later with SPS. The residents could give a maximum of three diagnoses per case. A maximum of 3 points was achieved if the correct diagnosis without any additional diagnoses was provided. The residents achieved an average score of 17.6 ± 5.0 points without SPS. By using SPS, the residents increased their score by 81.8% to 32.0 ± 9.5 points. The improvement of the score per case was highly significant (p = 0.0001). The residents required an average of 205.9 ± 350.6 s per case (21.9% increase) when SPS was used. However, in the second half of the cases, after the residents became more familiar with SPS, this increase dropped to 7%. Residents' average score in reading complex chest CT scans improved by 81.8% when the AI-driven SPS with integrated clinical reference content was used. The increase in time per case due to the use of the SPS was minimal.


Subject(s)
Lung Diseases , Pilots , Humans , Rare Diseases , Reading , Tomography, X-Ray Computed/methods , Lung Diseases/diagnostic imaging , Artificial Intelligence
SELECTION OF CITATIONS
SEARCH DETAIL