ABSTRACT
AIMS: RECOVER AF evaluated the performance of whole-chamber non-contact charge-density mapping to guide the ablation of non-pulmonary vein (PV) targets in persistent atrial fibrillation (AF) patients following either a first or second failed procedure. METHODS AND RESULTS: RECOVER AF was a prospective, non-randomized trial that enrolled patients scheduled for a first or second ablation retreatment for recurrent AF. The PVs were assessed and re-isolated if necessary. The AF maps were used to guide the ablation of non-PV targets through elimination of pathologic conduction patterns (PCPs). Primary endpoint was freedom from AF on or off antiarrhythmic drugs (AADs) at 12 months. Patients undergoing retreatment with the AcQMap System (n = 103) were 76% AF-free at 12 months [67% after single procedure (SP)] on or off AADs (80% free from AF on AADs). Patients who had only received a pulmonary vein isolation (PVI) prior to study treatment of non-PV targets with the AcQMap System were 91% AF-free at 12 months (83% SP). No major adverse events were reported. CONCLUSION: Non-contact mapping can be used to target and guide the ablation of PCPs beyond the PVs in persistent AF patients returning for a first or second retreatment with 76% freedom from AF at 12 months. The AF freedom was particularly high, 91% (43/47), for patients enrolled having only a prior de novo PVI, and freedom from all atrial arrhythmias for this cohort was 74% (35/47). These early results are encouraging and suggest that guiding individualized targeted ablation of PCPs may therefore be advantageous to target at the earliest opportunity in patients with persistent AF.
Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Prospective Studies , Pulmonary Veins/surgery , Retreatment , Anti-Arrhythmia Agents , Catheter Ablation/adverse effects , Catheter Ablation/methods , Treatment Outcome , RecurrenceABSTRACT
PURPOSE OF REVIEW: Cardiac arrhythmias are known complications in patients with COVID-19 infection that may persist even after recovery from infection. A review of the spectrum of cardiac arrhythmias due to COVID-19 infection and current guidelines and assessment or risk and benefit of management considerations is necessary as the population of patients infected and covering from COVID-19 continues to grow. RECENT FINDINGS: Cardiac arrhythmias such as atrial fibrillation, supraventricular tachycardia, complete heart block, and ventricular tachycardia occur in patients infected, recovering and recovered from COVID-19. Personalized care while balancing risk/benefit of medical or invasive therapy is necessary to improve care of patients with arrhythmias. Providers must provide thorough follow-up care and use necessary precaution while caring for COVID-19 patients.
Subject(s)
Atrial Fibrillation , COVID-19 , Tachycardia, Supraventricular , Humans , Pandemics , SARS-CoV-2 , Tachycardia, Supraventricular/therapyABSTRACT
Computational models of cardiac electrophysiology have gradually matured during the past few decades and are now being personalised to provide patient-specific therapy guidance for improving suboptimal treatment outcomes. The predictive features of these personalised electrophysiology models hold the promise of providing optimal treatment planning, which is currently limited in the clinic owing to reliance on a population-based or average patient approach. The generation of a personalised electrophysiology model entails a sequence of steps for which a range of activation mapping, calibration methods and therapy simulation pipelines have been suggested. However, the optimal methods that can potentially constitute a clinically relevant in silico treatment are still being investigated and face limitations, such as uncertainty of electroanatomical data recordings, generation and calibration of models within clinical timelines and requirements to validate or benchmark the recovered tissue parameters. This paper is aimed at reporting techniques on the personalisation of cardiac computational models, with a focus on calibrating cardiac tissue conductivity based on electroanatomical mapping data.
ABSTRACT
Conventional biventricular (BiV) pacing cardiac resynchronization therapy (CRT) is an established treatment for heart failure patients. Recently, multiple novel CRT delivering technologies such as His-Bundle pacing have been investigated as alternative pacing strategies for optimal treatment benefit. Electromechanical Wave Imaging (EWI), a high frame-rate echocardiography-based modality, is capable of visualizing the change from dyssynchronous activation to resynchronized BiV-paced ventricles in 3D. This proof-of-concept study introduces a new EWI-based dispersion metric to further characterize ventricular activation. Patients with His-Bundle device implantation (n = 4), left-bundle branch block (n = 10), right-ventricular (RV) pacing (n = 10), or BiV pacing (n = 15) were imaged, as well as four volunteers in normal sinus rhythm (NSR). EWI successfully mapped the ventricular activation resulting from His-Bundle pacing. Additionally, very similar activation patterns were obtained in the NSR subjects, confirming recovery of physiological activation with His pacing. The dispersion metric was the most sensitive EWI-based metric that identified His pacing as the most efficient treatment (lowest activation time spread), followed by BiV and RV pacing. More specifically, the dispersion metric significantly (p < 0.005) distinguished His pacing from the other two pacing schemes as well as LBBB. The initial findings presented herein indicate that EWI and its new dispersion metric may provide a useful resynchronization evaluation clinical tool in CRT patients under both novel His-Bundle pacing and more conventional BiV pacing strategies.
Subject(s)
Cardiac Resynchronization Therapy , Humans , Cardiac Resynchronization Therapy/methods , Bundle-Branch Block/diagnostic imaging , Bundle-Branch Block/therapy , Heart Ventricles/diagnostic imaging , Echocardiography , Arrhythmias, CardiacABSTRACT
Standard Electromechanical Wave Imaging isochrone generation relies on manual selection of zero-crossing (ZC) locations on incremental strain curves for a number of pixels in the segmented myocardium for each echocardiographic view and patient. When considering large populations, this becomes a time-consuming process, that can be limited by inter-observer variability and operator bias. In this study, we developed and optimized an automated ZC selection algorithm, towards a faster more robust isochrone generation approach. The algorithm either relies on heuristic-based baselines or machine learning classifiers. Manually generated isochrones, previously validated against 3D intracardiac mapping, were considered as ground truth during training and performance evaluation steps. The machine learning models applied herein for the first time were: i) logistic regression; ii) support vector machine (SVM); and iii) Random Forest. The SVM and Random Forest classifiers successfully identified accessory pathways in Wolff-Parkinson-White patients, characterized sinus rhythm in humans, and localized the pacing electrode location in left ventricular paced canines on the resulting isochrones. Nevertheless, the best performing classifier was proven to be Random Forest with a precision rising from 89.5% to 97%, obtained with the voting approach that sets a probability threshold upon ZC candidate selection. Furthermore, the predictivity was not dependent on the type of testing dataset it was applied to, contrary to SVM that exhibited a 5% drop in precision on the canine testing dataset. Finally, these findings indicate that a machine learning approach can reduce user variability and considerably decrease the durations required for isochrone generation, while preserving accurate activation patterns.
Subject(s)
Algorithms , Machine Learning , Animals , Diagnostic Imaging , Dogs , Heart , Humans , Support Vector MachineABSTRACT
Reentrant cardiac arrhythmias such as atrial fibrillation (AF) and ventricular fibrillation (VF) are common cardiac arrhythmias that account for substantial morbidity and mortality throughout the world. However, the mechanisms and optimal ablation treatment strategies for such arrhythmias are still unclear. Using 2D optical mapping of a mouse model with AF and VF, we have identified regional heterogeneity of the action potential duration (APD) in the atria and ventricles of the heart as key drivers for the initiation and persistence of reentry. The purpose of this paper is to discuss theoretical patterns of dispersion, demonstrate patterns of dispersion seen in our mouse model and discuss the computational analysis of APD dispersion patterns. These analyses and discussions may lead to better understanding of dispersion patterns in patients with these arrhythmias, as well as help comprehend whether and how reducing dispersion can lead to arrhythmia risk stratification and treatment strategies for arrhythmias.
ABSTRACT
BACKGROUND: Cardiac resynchronization therapy (CRT) response assessment relies on the QRS complex narrowing criterion. Yet one third of patients do not improve despite narrowed QRS after implantation. Electromechanical wave imaging (EWI) is a quantitative echocardiography-based technique capable of noninvasively mapping cardiac electromechanical activation in three dimensions. The aim of this exploratory study was to investigate the EWI technique, sensitive to ventricular dyssynchrony, for informing CRT response on the day of implantation. METHODS: Forty-four patients with heart failure with left bundle branch block or right ventricular (RV) paced rhythm and decreased left ventricular ejection fraction (LVEF; mean, 25.3 ± 9.6%) underwent EWI without and with CRT within 24 hours of device implantation. Of those, 16 were also scanned while in left ventricular (LV) pacing. Improvement in LVEF at 3-, 6-, or 9-month follow-up defined (1) super-responders (ΔLVEF ≥ 20%), (2) responders (10% ≤ ΔLVEF < 20%), and (3) nonresponders (ΔLVEF ≤ 5%). Three-dimensionally rendered electromechanical maps were obtained under RV, LV, and biventricular CRT pacing conditions. Mean RV free wall and LV lateral wall activation times were computed. The percentage of resynchronized myocardium was measured by quantifying the percentage of the left ventricle activated within 120 msec of QRS onset. Correlations between percentage of resynchronized myocardium and type of CRT response were assessed. RESULTS: LV lateral wall activation time was significantly different (P ≤ .05) among all three pacing conditions in the 16 patients: LV lateral wall activation time with CRT in biventricular pacing (73.1 ± 17.6 msec) was lower compared with LV pacing (89.5 ± 21.5 msec) and RV pacing (120.3 ± 17.8 msec). Retrospective analysis showed that the percentage of resynchronized myocardium with CRT was a reliable response predictor within 24 hours of implantation for significantly (P ≤ .05) identifying super-responders (n = 7; 97.7 ± 1.9%) from nonresponders (n = 17; 89.9 ± 9.9%). CONCLUSION: Electromechanical activation mapping constitutes a valuable three-dimensional visualization tool within 24 hours of implantation and could potentially aid in the timely assessment of CRT response rates, including during implantation for adjustment of lead placement and pacing outcomes.
Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Heart Failure/diagnostic imaging , Heart Failure/therapy , Heart Ventricles , Humans , Pilot Projects , Retrospective Studies , Stroke Volume , Treatment Outcome , Ventricular Function, LeftABSTRACT
Cardiac arrhythmias are a major cause of morbidity and mortality worldwide. The 12-lead electrocardiogram (ECG) is the current noninvasive clinical tool used to diagnose and localize cardiac arrhythmias. However, it has limited accuracy and is subject to operator bias. Here, we present electromechanical wave imaging (EWI), a high-frame rate ultrasound technique that can noninvasively map with high accuracy the electromechanical activation of atrial and ventricular arrhythmias in adult patients. This study evaluates the accuracy of EWI for localization of various arrhythmias in all four chambers of the heart before catheter ablation. Fifty-five patients with an accessory pathway (AP) with Wolff-Parkinson-White (WPW) syndrome, premature ventricular complexes (PVCs), atrial tachycardia (AT), or atrial flutter (AFL) underwent transthoracic EWI and 12-lead ECG. Three-dimensional (3D) rendered EWI isochrones and 12-lead ECG predictions by six electrophysiologists were applied to a standardized segmented cardiac model and subsequently compared to the region of successful ablation on 3D electroanatomical maps generated by invasive catheter mapping. There was significant interobserver variability among 12-lead ECG reads by expert electrophysiologists. EWI correctly predicted 96% of arrhythmia locations as compared with 71% for 12-lead ECG analyses [unadjusted for arrhythmia type: odds ratio (OR), 11.8; 95% confidence interval (CI), 2.2 to 63.2; P = 0.004; adjusted for arrhythmia type: OR, 12.1; 95% CI, 2.3 to 63.2; P = 0.003]. This double-blinded clinical study demonstrates that EWI can localize atrial and ventricular arrhythmias including WPW, PVC, AT, and AFL. EWI when used with ECG may allow for improved treatment for patients with arrhythmias.
Subject(s)
Arrhythmias, Cardiac , Catheter Ablation , Adult , Arrhythmias, Cardiac/diagnostic imaging , Diagnostic Imaging , Electrocardiography , Humans , UltrasonographyABSTRACT
OBJECTIVES: This study sought to demonstrate the feasibility of electromechanical wave imaging (EWI) for localization of accessory pathways (AP) prior to catheter ablation in a pediatric population. BACKGROUND: Prediction of AP locations in patients with Wolff-Parkinson-White syndrome is currently based on analysis of 12-lead electrocardiography (ECG). In the pediatric population, specific algorithms have been developed to aid in localization, but these can be unreliable. EWI is a noninvasive imaging modality relying on a high frame rate ultrasound sequence capable of visualizing cardiac electromechanical activation. METHODS: Pediatric patients with ventricular pre-excitation presenting for catheter ablation were imaged with EWI immediately prior to the start of the procedure. Two clinical pediatric electrophysiologists predicted the location of the AP based on ECG. Both EWI and ECG predictions were blinded to the results of catheter ablation. EWI and ECG localizations were subsequently compared with the site of successful ablation. RESULTS: Fifteen patients were imaged with EWI. One patient was excluded for poor echocardiographic windows and the inability to image the entire ventricular myocardium. EWI correctly predicted the location of the AP in all 14 patients. ECG analysis correctly predicted 11 of 14 (78.6%) of the AP locations. CONCLUSIONS: EWI was shown to be capable of consistently localizing accessory pathways. EWI predicted the site of successful ablation more frequently than analysis of 12-lead ECG. EWI isochrones also provide anatomical visualization of ventricular pre-excitation. These findings suggest that EWI can predict AP locations, and EWI may have the potential to better inform clinical electrophysiologists prior to catheter ablation procedures.
Subject(s)
Accessory Atrioventricular Bundle/diagnostic imaging , Cardiac Imaging Techniques/methods , Imaging, Three-Dimensional/methods , Wolff-Parkinson-White Syndrome/diagnostic imaging , Accessory Atrioventricular Bundle/surgery , Adolescent , Algorithms , Catheter Ablation , Child , Electrocardiography , Electromagnetic Radiation , Feasibility Studies , Female , Humans , Male , Wolff-Parkinson-White Syndrome/surgeryABSTRACT
Arrhythmia localization prior to catheter ablation is critical for clinical decision making and treatment planning. The current standard lies in 12-lead electrocardiogram (ECG) interpretation, but this method is non-specific and anatomically limited. Accurate localization requires intracardiac catheter mapping prior to ablation. Electromechanical Wave Imaging (EWI) is a high frame-rate ultrasound modality capable of non-invasively mapping the electromechanical activation in all cardiac chambers in vivo. In this study, we evaluate 3D-rendered EWI as a technique for consistently localizing the accessory pathway (AP) in Wolff-Parkinson-White (WPW) pediatric patients. A 2000 Hz EWI diverging sequence was used to transthoracically image 13 patients with evidence of ECG pre-excitation, immediately prior to catheter ablation and after successful ablation whenever possible. 3D-rendered activation maps were generated by co-registering and interpolating the 4 resulting multi-2D isochrones. A blinded electrophysiologist predicted the AP location on 12-lead ECG prior to ablation. Double-blinded EWI isochrones and clinician assessments were compared to the successful ablation site as confirmed by intracardiac mapping using a segmented template of the heart with 19 ventricular regions. 3D-rendered EWI was shown capable of consistently localizing AP in all the WPW cases. Clinical ECG interpretation correctly predicted the origin with an accuracy of 53.8%, respectively 84.6% when considering predictions in immediately adjacent segments correct. Our method was also capable of assessing the difference in activation pattern from before to after successful ablation on the same patient. These findings indicate that EWI could inform current diagnosis and expedite treatment planning of WPW ablation procedures.
Subject(s)
Catheter Ablation , Electrocardiography , Heart/diagnostic imaging , Wolff-Parkinson-White Syndrome/diagnosis , Child , Humans , Imaging, Three-DimensionalABSTRACT
There is currently no established method for the non-invasive characterization of arrhythmia and differentiation between endocardial and epicardial triggers at the point of care. Electromechanical wave imaging (EWI) is a novel ultrasound-based imaging technique based on time-domain transient strain estimation that can map and characterize electromechanical activation in the heart in vivo. The objectives of this initial feasibility study were to determine that EWI is capable of differentiating between endocardial and epicardial sources of focal rhythm and, as a proof-of-concept, that EWI could characterize focal arrhythmia in one patient with premature ventricular contractions (PVCs) before radiofrequency (RF) ablation treatment. First, validation of EWI for differentiation of surface of origin was performed in seven (nâ¯=â¯7) adult dogs using four epicardial and four endocardial pacing protocols. Second, one (nâ¯=â¯1) adult patient diagnosed with PVC was imaged with EWI before the scheduled RF ablation procedure, and EWI results were compared with mapping procedure results. In dogs, EWI was capable of detecting whether pacing was of endocardial or epicardial origin in six of seven cases (86% success rate). In the PVC patient, EWI correctly identified both regions and surface of origin, as confirmed by results from the electrical mapping obtained from the RF ablation procedure. These results reveal that EWI can map the electromechanical activation across the myocardium and indicate that EWI could serve as a valuable pre-treatment planning tool in the clinic.
Subject(s)
Arrhythmias, Cardiac/diagnostic imaging , Arrhythmias, Cardiac/physiopathology , Aged , Animals , Arrhythmias, Cardiac/surgery , Catheter Ablation , Disease Models, Animal , Dogs , Feasibility Studies , Heart/diagnostic imaging , Heart/physiopathology , Humans , Reproducibility of Results , Ultrasonography/methodsABSTRACT
Electromechanical wave imaging (EWI) is an ultrasound-based technique that can non-invasively map the transmural electromechanical activation in all four cardiac chambers in vivo. The objective of this study was to determine the reproducibility and angle independence of EWI for the assessment of electromechanical activation during normal sinus rhythm (NSR) in healthy humans. Acquisitions were performed transthoracically at 2000 frames/s on seven healthy human hearts in parasternal long-axis, apical four- and two-chamber views. EWI data was collected twice successively in each view in all subjects, while four successive acquisitions were obtained in one case. Activation maps were generated and compared (i) within the same acquisition across consecutive cardiac cycles; (ii) within same view across successive acquisitions; and (iii) within equivalent left-ventricular regions across different views. EWI was capable of characterizing electromechanical activation during NSR and of reliably obtaining similar patterns of activation. For consecutive heart cycles, the average 2-D correlation coefficient between the two isochrones across the seven subjects was 0.9893, with a mean average activation time fluctuation in LV wall segments across acquisitions of 6.19%. A mean activation time variability of 12% was obtained across different views with a measurement bias of only 3.2 ms. These findings indicate that EWI can map the electromechanical activation during NSR in human hearts in transthoracic echocardiography in vivo and results in reproducible and angle-independent activation maps.
Subject(s)
Heart/physiology , Ultrasonography/methods , Adult , Heart/diagnostic imaging , Humans , Male , Reference Values , Reproducibility of Results , Young AdultABSTRACT
PURPOSE: Arrhythmias can be treated by ablating the heart tissue in the regions of abnormal contraction. The current clinical standard provides electroanatomic 3-D maps to visualize the electrical activation and locate the arrhythmogenic sources. However, the procedure is time-consuming and invasive. Electromechanical wave imaging is an ultrasound-based noninvasive technique that can provide 2-D maps of the electromechanical activation of the heart. In order to fully visualize the complex 3-D pattern of activation, several 2-D views are acquired and processed separately. They are then manually registered with a 3-D rendering software to generate a pseudo-3-D map. However, this last step is operator-dependent and time-consuming. METHODS: This paper presents a method to generate a full 3-D map of the electromechanical activation using multiple 2-D images. Two canine models were considered to illustrate the method: one in normal sinus rhythm and one paced from the lateral region of the heart. Four standard echographic views of each canine heart were acquired. Electromechanical wave imaging was applied to generate four 2-D activation maps of the left ventricle. The radial positions and activation timings of the walls were automatically extracted from those maps. In each slice, from apex to base, these values were interpolated around the circumference to generate a full 3-D map. RESULTS: In both cases, a 3-D activation map and a cine-loop of the propagation of the electromechanical wave were automatically generated. The 3-D map showing the electromechanical activation timings overlaid on realistic anatomy assists with the visualization of the sources of earlier activation (which are potential arrhythmogenic sources). The earliest sources of activation corresponded to the expected ones: septum for the normal rhythm and lateral for the pacing case. CONCLUSIONS: The proposed technique provides, automatically, a 3-D electromechanical activation map with a realistic anatomy. This represents a step towards a noninvasive tool to efficiently localize arrhythmias in 3-D.
Subject(s)
Algorithms , Heart Conduction System/diagnostic imaging , Ultrasonography , Animals , Arrhythmias, Cardiac/therapy , Dogs , Heart , Heart Ventricles , Humans , Models, AnimalABSTRACT
Echocardiography is often used in the clinic for detection and characterization of myocardial infarction. Electromechanical wave imaging (EWI) is a non-invasive ultrasound-based imaging technique based on time-domain incremental motion and strain estimation that can evaluate changes in contractility in the heart. In this study, electromechanical activation is assessed in infarcted heart to determine whether EWI is capable of detecting and monitoring infarct formation. Additionally, methods for estimating electromechanical wave (EW) velocity are presented, and changes in the EW propagation velocity after infarct formation are studied. Five (n = 5) adult mongrels were used in this study. Successful infarct formation was achieved in three animals by ligation of the left anterior descending (LAD) coronary artery. Dogs were survived for a few days after LAD ligation and monitored daily with EWI. At the end of the survival period, dogs were sacrificed and TTC (tetrazolium chloride) staining confirmed the formation and location of the infarct. In all three dogs, as soon as day 1 EWI was capable of detecting late-activated and non-activated regions, which grew over the next few days. On final day images, the extent of these regions corresponded to the location of infarct as confirmed by staining. EW velocities in border zones of infarct were significantly lower post-infarct formation when compared to baseline, whereas velocities in healthy tissues were not. These results indicate that EWI and EW velocity might help with the detection of infarcts and their border zones, which may be useful for characterizing arrhythmogenic substrate.