Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 214
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Clin Transplant ; 38(4): e15294, 2024 04.
Article in English | MEDLINE | ID: mdl-38545881

ABSTRACT

BACKGROUND: Recent studies suggest the transplantation of Hepatitis C (HCV) hearts from viremic donors is associated with comparable 1 year survival to nonviremic donors. Though HCV viremia is a known risk factor for accelerated atherosclerosis, data on cardiac allograft vasculopathy (CAV) outcomes are limited. We compared the incidence of CAV in heart transplant recipients from HCV viremic donors (nucleic acid amplification test positive; NAT+) compared to non-HCV infected donors (NAT-). METHODS: We retrospectively reviewed annual coronary angiograms with intravascular ultrasound from April 2017 to August 2020 at two large cardiac transplant centers. CAV was graded according to ISHLT guidelines. Maximal intimal thickness (MIT) ≥ 0.5 mm was considered significant for subclinical disease. RESULTS: Among 270 heart transplant recipients (mean age 54; 77% male), 62 patients were transplanted from NAT+ donors. CAV ≥ grade 1 was present in 8.8% of the NAT+ versus 16.8% of the NAT- group at 1 year, 20% versus 28.8% at 2 years, and 33.3% versus 41.5% at 3 years. After adjusting for donor age, donor smoking history, recipient BMI, recipient, hypertension, and recipient diabetes, NAT+ status did not confer increased risk of CAV (HR.80; 95% CI.45-1.40, p = 0.43) or subclinical IVUS disease (HR.87; 95% CI.58-1.30, p = 0.49). Additionally, there was no difference in the presence of rapidly progressive lesions on IVUS. CONCLUSION: Our data show that NAT+ donors conferred no increased risk for early CAV or subclinical IVUS disease following transplantation in a cohort of heart transplant patients who were treated for HCV, suggesting the short-term safety of this strategy to maximize the pool of available donor hearts.


Subject(s)
Heart Transplantation , Hepatitis C , Humans , Male , Middle Aged , Female , Tissue Donors , Retrospective Studies , Heart Transplantation/adverse effects , Viremia/epidemiology , Viremia/etiology , Follow-Up Studies , Hepatitis C/etiology , Hepacivirus , Allografts , Transplant Recipients
2.
Clin Transplant ; 38(3): e15269, 2024 03.
Article in English | MEDLINE | ID: mdl-38445531

ABSTRACT

INTRODUCTION: Thoracoabdominal normothermic regional perfusion (TA-NRP) following cardiac death is an emerging multivisceral organ procurement technique. Recent national studies on outcomes of presumptive TA-NRP-procured organs are limited by potential misclassification since TA-NRP is not differentiated from donation after cardiac death (DCD) in registry data. METHODS: We studied 22 donors whose designees consented to TA-NRP and organ procurement performed at our institution between January 20, 2020 and July 3, 2022. We identified these donors in SRTR to describe organ utilization and recipient outcomes and compared them to recipients of traditional DCD (tDCD) and donation after brain death (DBD) organs during the same timeframe. RESULTS: All 22 donors progressed to cardiac arrest and underwent TA-NRP followed by heart, lung, kidney, and/or liver procurement. Median donor age was 41 years, 55% had anoxic brain injury, 45% were hypertensive, 0% were diabetic, and median kidney donor profile index was 40%. TA-NRP utilization was high across all organ types (88%-100%), with a higher percentage of kidneys procured via TA-NRP compared to tDCD (88% vs. 72%, p = .02). Recipient and graft survival ranged from 89% to 100% and were comparable to tDCD and DBD recipients (p ≥ .2). Delayed graft function was lower for kidneys procured from TA-NRP compared to tDCD donors (27% vs. 44%, p = .045). CONCLUSION: Procurement from TA-NRP donors yielded high organ utilization, with outcomes comparable to tDCD and DBD recipients across organ types. Further large-scale study of TA-NRP donors, facilitated by its capture in the national registry, will be critical to fully understand its impact as an organ procurement technique.


Subject(s)
Benzidines , Heart , Tissue and Organ Procurement , Humans , Adult , Perfusion , Tissue Donors , Brain Death
3.
Crit Care ; 27(1): 243, 2023 06 19.
Article in English | MEDLINE | ID: mdl-37337243

ABSTRACT

OBJECTIVES: The CytoSorb therapy in COVID-19 (CTC) registry evaluated the clinical performance and treatment parameters of extracorporeal hemoadsorption integrated with veno-venous extracorporeal membrane oxygenation (VV ECMO) in critically ill COVID-19 patients with acute respiratory distress syndrome (ARDS) and respiratory failure under US FDA Emergency Use Authorization. DESIGN: Multicenter, observational, registry (NCT04391920). SETTING: Intensive care units (ICUs) in five major US academic centers between April 2020 and January 2022. PATIENTS: A total of 100 critically ill adults with COVID-19-related ARDS requiring VV ECMO support, who were treated with extracorporeal hemoadsorption. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Baseline demographics, clinical characteristics, laboratory values and outcomes were recorded following individual ethics committee approval at each center. Detailed data on organ support utilization parameters and hemoadsorption treatments were also collected. Biomarker data were collected according to the standard practice at each participating site, and available values were compared before and after hemoadsorption. The primary outcome of mortality was evaluated using a time-to-event analysis. A total of 100 patients (63% male; age 44 ± 11 years) were included. Survival rates were 86% at 30 days and 74% at 90 days. Median time from ICU admission to the initiation of hemoadsorption was 87 h and was used to define two post hoc groups: ≤ 87 h (group-early start, GE) and > 87 h (group-late start, GL). After the start of hemoadsorption, patients in the GE versus GL had significantly shorter median duration of mechanical ventilation (7 [2-26] vs. 17 [7-37] days, p = 0.02), ECMO support (13 [8-24] vs. 29 [14-38] days, p = 0.021) and ICU stay (17 [10-40] vs 36 [19-55] days, p = 0.002). Survival at 90 days in GE was 82% compared to 66% in GL (p = 0.14). No device-related adverse events were reported. CONCLUSIONS: In critically ill patients with severe COVID-19-related ARDS treated with the combination of VV-ECMO and hemoadsorption, 90-day survival was 74% and earlier intervention was associated with shorter need for organ support and ICU stay. These results lend support to the concept of "enhanced lung rest" with the combined use of VV-ECMO plus hemoadsorption in patients with ARDS.


Subject(s)
COVID-19 , Extracorporeal Membrane Oxygenation , Respiratory Distress Syndrome , Adult , Humans , Male , Middle Aged , Female , COVID-19/complications , COVID-19/therapy , Extracorporeal Membrane Oxygenation/methods , Critical Illness/therapy , Registries , Retrospective Studies
4.
Am J Transplant ; 22(5): 1307-1310, 2022 05.
Article in English | MEDLINE | ID: mdl-35072337

ABSTRACT

This paper responds to the position statement released by the American College of Physicians (ACP) entitled "Ethics, Determination of Death, and Organ Transplantation in Normothermic Regional Perfusion (NRP) with Controlled Donation after Circulatory Determination of Death (cDCD): American College of Physicians Statement of Concern." The ACP's statement engages with critical ethical issues surrounding cDCD NRP, but several of their conclusions are flawed. Contrary to the statement, the practice respects the dead donor rule and the legal definition of death while honoring the wishes of the deceased and their loved ones to help save the lives of those in need of organ transplants. cDCD NRP is well established in many countries, it can enhance trust in medical practice and organ donation, and will increase the availability of optimal organs for life-saving transplants.


Subject(s)
Physicians , Tissue and Organ Procurement , Death , Humans , Organ Preservation , Perfusion , Tissue Donors , United States
5.
Am J Transplant ; 22(12): 2951-2960, 2022 12.
Article in English | MEDLINE | ID: mdl-36053676

ABSTRACT

The long-term safety of heart transplants from hepatitis C viremic (NAT+) donors remains uncertain. We conducted a prospective study of all patients who underwent heart transplantation at our center from January 2018 through August 2020. Routine testing was performed to assess for donor-derived cell-free DNA, acute cellular rejection (ACR), antibody-mediated rejection (AMR), and cardiac allograft vasculopathy (CAV). Allograft dysfunction and mortality were also monitored. Seventy-five NAT- recipients and 32 NAT+ recipients were enrolled in the study. All NAT+ recipients developed viremia detected by PCR, were treated with glecaprevir/pibrentasvir at the time of viremia detection, and cleared the virus by 59 days post-transplant. Patients who underwent NAT testing starting on post-operative day 7 (NAT+ Group 1) had significantly higher viral loads and were viremic for a longer period compared with patients tested on post-operative day 1 (NAT+ Group 2). Through 3.5 years of follow-up, there were no statistically significant differences in timing, severity, or frequency of ACR in NAT+ recipients compared with the NAT- cohort, nor were there differences in noninvasive measures of graft injury, incidence or severity of CAV, graft dysfunction, or mortality. There were five episodes of AMR, all in the NAT- group. There were no statistically significant differences between Group 1 and Group 2 NAT+ cohorts. Overall, these findings underscore the safety of heart transplantation from NAT+ donors.


Subject(s)
Heart Transplantation , Hepatitis C , Humans , Follow-Up Studies , Heart Transplantation/adverse effects , Hepacivirus , Prospective Studies , Tissue Donors , Transplant Recipients , Viremia/etiology
6.
Clin Transplant ; 36(7): e14745, 2022 07.
Article in English | MEDLINE | ID: mdl-35678734

ABSTRACT

INTRODUCTION: ImmuKnow, an immune cell function assay that quantifies overall immune system activity can assist in post-transplant immunosuppression adjustment. However, the utility of pre-transplant ImmuKnow results representing a patient's baseline immune system activity is unknown. This study sought to assess if pre-transplant ImmuKnow results are predictive of rejection at the time of first biopsy in our cardiac transplant population. METHODS: This is a single center, retrospective observational study of consecutive patients from January 1, 2018 to October 1, 2020 who underwent orthotopic cardiac transplantation at NYU Langone Health. Patients were excluded if a pre-transplant ImmuKnow assay was not performed. ImmuKnow results were categorized according to clinical interpretation ranges (low, moderate, and high activity), and patients were divided into two groups: a low activity group versus a combined moderate-high activity group. Pre-transplant clinical characteristics, induction immunosuppression use, early postoperative tacrolimus levels, and first endomyocardial biopsy results were collected for all patients. Rates of clinically significant early rejection (defined as rejection ≥ 1R/1B) were compared between pre-transplant ImmuKnow groups. RESULTS: Of 110 patients who underwent cardiac transplant, 81 had pre-transplant ImmuKnow results. The low ImmuKnow activity group was comprised of 15 patients, and 66 patients were in the combined moderate-high group. Baseline characteristics were similar between groups. Early rejection occurred in 0 (0%) patients with low pre-transplant ImmuKnow levels. Among the moderate- high pre-transplant ImmuKnow group, 16 (24.2%) patients experienced early rejection (P = .033). The mean ImmuKnow level in the non-rejection group was the 364.9 ng/ml of ATP compared to 499.3 ng/ml of ATP for those with rejection (P = .020). CONCLUSION: Patients with low pre-transplant ImmuKnow levels had lower risk of early rejection when compared with patients with moderate or high levels. Our study suggests a possible utility in performing pre-transplant ImmuKnow to identify patients at-risk for early rejection who may benefit from intensified upfront immunosuppression as well as to recognize those where slower calcineurin inhibitor initiation may be appropriate.


Subject(s)
CD4-Positive T-Lymphocytes , Graft Rejection , Heart Transplantation , Adenosine Triphosphate/analysis , Adult , Aged , CD4-Positive T-Lymphocytes/immunology , Female , Graft Rejection/diagnosis , Graft Rejection/prevention & control , Humans , Immunoassay , Immunosuppressive Agents/therapeutic use , Male , Middle Aged , Preoperative Period , Retrospective Studies
7.
Artif Organs ; 46(4): 643-652, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34780074

ABSTRACT

BACKGROUND: The VentriFlo® True Pulse Pump (VentriFlo, Inc, Pelham, NH, USA) is a new pulsatile blood pump intended for use during short-term circulatory support. The purpose of this study was to evaluate the feasibility of the VentriFlo and compare it to a conventional centrifugal pump (ROTAFLOW, Getinge, Gothenberg, Sweden) in acute pig experiments. METHODS: Pigs (40-45 kg) were supported by cardiopulmonary bypass (CPB) with the VentriFlo (n = 9) or ROTAFLOW (n = 5) for 6 h. Both VentriFlo and ROTAFLOW circuits utilized standard CPB components. We evaluated hemodynamics, blood chemistry, gas analysis, plasma hemoglobin, and microcirculation at the groin skin with computer-assisted video microscopy (Optilia, Sollentuna, Sweden). RESULTS: Pigs were successfully supported by CPB for 6 h without any pump-related complications in either group. The VentriFlo delivered an average stroke volume of 29.2 ± 4.8 ml. VentriFlo delivered significantly higher pulse pressure (29.1 ± 7.2 mm Hg vs. 4.4 ± 7.0 mm Hg, p < 0.01) as measured in the carotid artery, with mean aortic pressure and pump flow comparable with those in ROTAFLOW. In blood gas analysis, arterial pH was significantly lower after five hours support in the VentriFlo group (7.30 ± 0.07 vs. 7.43 ± 0.03, p = 0.001). There was no significant difference in plasma hemoglobin level in both groups after six hours of CPB support. In microcirculatory assessment, VentriFlo tended to keep normal capillary flow, but it was not statistically significant. CONCLUSIONS: VentriFlo-supported pigs showed comparable hemodynamic parameters with significantly higher pulse pressure compared to ROTAFLOW without hemolysis.


Subject(s)
Cardiopulmonary Bypass , Heart-Assist Devices , Animals , Cardiopulmonary Bypass/adverse effects , Heart-Assist Devices/adverse effects , Hemodynamics , Microcirculation , Pulsatile Flow , Swine
8.
Heart Lung Circ ; 31(6): 815-821, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35165053

ABSTRACT

BACKGROUND: Specific aetiologies of cardiomyopathy can significantly impact treatment options as well as appropriateness and prioritisation for advanced heart failure therapies such as ventricular assist device (VAD) or orthotopic heart transplantation (OHT). We reviewed the tissue diagnoses of patients who underwent advanced therapies for heart failure (HF) to identify diagnostic discrepancies. METHODS: This study presents a retrospective cohort of the aetiology of cardiomyopathy in 118 patients receiving either durable VAD or OHT. Discrepancies between the preoperative aetiological diagnosis of cardiomyopathy with the pathological diagnosis were recorded. Echocardiographic and haemodynamic data were reviewed to examine differences in patients with differing aetiological diagnoses. RESULTS: Twelve (12) of 118 (12/118) (10.2%) had a pathological diagnosis that was discordant with pre-surgical diagnosis. The most common missed diagnoses were infiltrative cardiomyopathy (5) and hypertrophic cardiomyopathy (3). Patients with misidentified aetiology of cardiomyopathy had smaller left ventricular (LV) dimensions on echocardiography than patients with dilated cardiomyopathy (5.8±0.9 vs 6.7±1.1 respectively p=0.01). CONCLUSIONS: Most HF patients undergoing VAD and OHT had a correct diagnosis for their heart failure prior to treatment, but a missed diagnosis at time of intervention (VAD or OHT) was not uncommon. Smaller LV dimension on echocardiogram in a patient with a non-ischaemic cardiomyopathy warrants further workup for a more specific aetiology.


Subject(s)
Cardiomyopathies , Heart Failure , Heart Transplantation , Heart-Assist Devices , Anti-Arrhythmia Agents , Cardiomyopathies/diagnosis , Cardiomyopathies/etiology , Cardiomyopathies/therapy , Cardiotonic Agents , Diuretics , Heart Failure/diagnosis , Heart Failure/etiology , Heart Failure/therapy , Heart-Assist Devices/adverse effects , Humans , Retrospective Studies
9.
J Card Surg ; 36(11): 4256-4264, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34219277

ABSTRACT

BACKGROUND AND AIM: Patients with severe coronavirus disease 2019 (COVID-19) develop a profound cytokine-mediated pro-inflammatory response. This study reports outcomes in 10 patients with COVID-19 supported on veno-venous extracorporeal membrane oxygenation (VV-ECMO) who were selected for the emergency use of a hemoadsorption column integrated in the ECMO circuit. MATERIALS AND METHODS: Pre and posttreatment, clinical data, and inflammatory markers were assessed to determine the safety and feasibility of using this system and to evaluate the clinical effect. RESULTS: During hemoadsorption, median levels of interleukin (IL)-2R, IL-6, and IL-10 decreased by 54%, 86%, and 64%, respectively. Reductions in other markers were observed for lactate dehydrogenase (-49%), ferritin (-46%), d-dimer (-7%), C-reactive protein (-55%), procalcitonin (-76%), and lactate (-44%). Vasoactive-inotrope scores decreased significantly over the treatment interval (-80%). The median hospital length of stay was 53 days (36-85) and at 90-days post cannulation, survival was 90% which was similar to a group of patients without the use of hemoadsorption. CONCLUSIONS: Addition of hemoadsorption to VV-ECMO in patients with severe COVID-19 is feasible and reduces measured cytokine levels. However, in this small series, the precise impact on the overall clinical course and survival benefit still remains unknown.


Subject(s)
COVID-19 , Extracorporeal Membrane Oxygenation , Respiratory Distress Syndrome , Catheterization , Humans , Respiratory Distress Syndrome/therapy , SARS-CoV-2
10.
Am J Transplant ; 20(6): 1508-1512, 2020 06.
Article in English | MEDLINE | ID: mdl-31913567

ABSTRACT

Controlled heart donation after circulatory determination of death (cDCD) is well established internationally with good outcomes and could be adopted in the United States to increase heart supply if ethical and logistical challenges are comprehensively addressed. The most effective and resource-efficient method for mitigating warm ischemia after circulatory arrest is normothermic regional perfusion (NRP) in situ. This strategy requires restarting circulation after declaration of death according to circulatory criteria, which appears to challenge the legal circulatory death definition requiring irreversible cessation. Permanent cessation for life-saving efforts must be achieved to assuage this concern and ligating principal vessels maintains no blood flow to the brain, which ensures natural progression to cessation of brain function. This practice-standard in some countries-raises unique concerns about prioritizing life-saving efforts, informed authorization from decision-makers, and the clinician's role in the patient's death. To preserve public trust, medical integrity, and respect for the donor, the donation conversation must not take place until after an un-coerced decision to withdraw life-sustaining treatment made in accordance with the patient's treatment goals. The decision-maker(s) must understand cDCD procedure well enough to provide genuine authorization and the preservation/procurement teams must be kept separate from the clinical care team.


Subject(s)
Heart Arrest , Heart Transplantation , Tissue and Organ Procurement , Death , Humans , Organ Preservation , Perfusion , Tissue Donors , United States
11.
Clin Transplant ; 34(10): e14030, 2020 10.
Article in English | MEDLINE | ID: mdl-32632929

ABSTRACT

We conducted a retrospective review of thoracic transplant recipients (22 heart and 16 lung transplant recipients) prospectively enrolled in a single-center observational study of HCV NAT+ organ transplantation in HCV NAT- recipients. All recipients were treated with 8 weeks of glecaprevir-pibrentasvir (GP) for HCV viremia in addition to standard triple immunosuppression post-transplant. Thoracic transplant recipients of HCV NAT- organs were used as a control (24 heart and 22 lung transplant recipients). Our primary outcome was to assess the effect of GP on tacrolimus dose requirements. Secondary objectives included assessing drug interactions with common post-transplant medications, adverse effects, and the need to hold or discontinue GP therapy. The median tacrolimus concentration-to-dose ratio (CDR) in the cohort was 184 (99-260) during GP therapy and 154 (78-304) over the first month after GP (P = .79). Trends in median tacrolimus CDR were similar on a per-week basis and per-patient basis. In three instances, concomitant posaconazole and GP led to hyperbilirubinemia and interruption of posaconazole. GP therapy was held in one heart transplant recipient and discontinued in another due to unresolving hyperbilirubinemia. Utilization of GP to treat HCV viremia post-thoracic transplant is feasible and safe, but requires modifications to post-transplant pharmacotherapy and careful monitoring for adverse effects.


Subject(s)
Hepatitis C , Transplant Recipients , Aminoisobutyric Acids , Antiviral Agents/therapeutic use , Benzimidazoles , Cyclopropanes , Hepacivirus , Hepatitis C/drug therapy , Humans , Lactams, Macrocyclic , Leucine/analogs & derivatives , Lung , Proline/analogs & derivatives , Pyrrolidines , Quinoxalines , Retrospective Studies , Sulfonamides , Viremia
12.
Clin Transplant ; 34(9): e13989, 2020 09.
Article in English | MEDLINE | ID: mdl-32441413

ABSTRACT

BACKGROUND: The use of direct-acting antivirals (DAA) has expanded transplantation from hepatitis C viremic donors (HCV-VIR). Our team has conducted an open-label, prospective trial to assess outcomes transplanting HCV viremic hearts. Glecaprevir/pibrentasvir (GLE/PIB) was our sole DAA. METHODS: Serial quantitative hepatitis C virus (HCV) RNA PCR was obtained to assess HCV viral titers. Between January 2018 and June 2019, a total of 50 recipients were transplanted. Of these, 22/50 (44%) were from HCV-VIR, the remaining 28 from non-viremic (HCV NON-VIR) donors. An 8-week course of GLE/PIB was initiated at 1 week post-transplant. RESULTS: There was no difference in demographic or clinical parameters between groups. All 22 recipients of HCV-VIR transplants became viremic. GLE/PIB was effective in decreasing viremia to undetectable levels by 6 weeks post-transplant in all patients. The median time to first undetectable HCV quantitative PCR was (4.3 weeks, IQR: 4-5.7 weeks). All patients demonstrated sustained undetectable viral load through 1-year follow-up. There was no difference in survival at one year between HCV NON-VIR 28/28: (100%) vs HCV-VIR 21/22 (95%) recipients. CONCLUSIONS: Our center reports excellent outcomes in transplanting utilizing hearts from HCV-VIR donors. No effect on survival or co-morbidity was found. An 8-week GLE/PIB course was safe and effective when initiated approximately 1 week post-transplant.


Subject(s)
Heart Transplantation , Hepatitis C, Chronic , Hepatitis C , Aminoisobutyric Acids , Antiviral Agents/therapeutic use , Benzimidazoles , Cyclopropanes , Hepacivirus/genetics , Hepatitis C/drug therapy , Hepatitis C, Chronic/drug therapy , Humans , Lactams, Macrocyclic , Leucine/analogs & derivatives , Proline/analogs & derivatives , Prospective Studies , Pyrrolidines , Quinoxalines , Sulfonamides , Treatment Outcome , Viremia/drug therapy , Viremia/etiology
13.
J Cardiothorac Vasc Anesth ; 34(11): 3073-3077, 2020 11.
Article in English | MEDLINE | ID: mdl-32660929

ABSTRACT

Worldwide, the majority of heart transplant organs are from donation after brain death. However, the shortage of suitable donors places severe limitations on this route. One option to increase the donor pool is to use organs from donation after circulatory death (DCD). Transplant centers for solid organs have been using DCD organs for years. At this time, 40% of solid organ transplantation in the United Kingdom uses organs from DCD. Use of DCD for solid organ transplants in Canada is also rising. Recently, there has been interest in using DCD organs for heart transplantation. The authors will discuss their experience of 4 heart transplants with organs from DCD donors after normothermic regional perfusion (NRP). The authors' first heart transplant using a DCD organ was in January 2020, and the fourth was in March 2020, just before the coronavirus disease 2019 (COVID-19) pandemic. The authors' protocol using NRP allows adequate evaluation of the donor heart to confidently determine organ acceptance. The co-location of the donor and the recipient in neighboring operating rooms limits ischemic times. Avoidance of an expensive ex vivo organ perfusion machine is an additional benefit for programs that may not have the resources required to purchase and maintain the machine. Some hospitals may not have the resources and space to be able to co-locate both the donor and recipient. Use of cold storage may be an option to transport the procured organ, similar to donation after brain death organs. The authors hope that this technique of NRP in DCD donors can help further increase the donor pool for heart transplantation in the United States.


Subject(s)
Anesthesia/methods , Anesthetics/therapeutic use , Betacoronavirus , Coronavirus Infections/epidemiology , Heart Diseases/surgery , Heart Transplantation/methods , Pneumonia, Viral/epidemiology , Tissue Donors/supply & distribution , Adolescent , Adult , COVID-19 , Comorbidity , Female , Heart Diseases/epidemiology , Humans , Male , Middle Aged , Pandemics , SARS-CoV-2 , Young Adult
14.
J Card Surg ; 35(12): 3310-3316, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32939839

ABSTRACT

BACKGROUND: The Impella (Abiomed) ventricular support system is a family of temporary mechanical circulatory support (MCS) devices used to treat patients with cardiogenic shock, acute cardiogenic decompensation, and for high-risk percutaneous or surgical revascularization. These devices include the percutaneously implanted 2.5/cardiac power (CP) and the surgically implanted 5.0/left direct (LD). Despite the beneficial effects and increased usage of these devices, data to assess adverse outcomes and guide clinician decision-making between the Impella CP and 5.0/LD are limited. METHODS: This is a retrospective analysis of 91 consecutive patients who required at least 24 h of Impella support, from January 1, 2015 to December 31, 2019. Groups were stratified based on either initial Impella CP or 5.0/LD placement. Clinical outcomes and in-hospital complications were compared. RESULTS: Impella CP was implanted in 66 patients (mean age: 61 ± 15 years, male 71.2%) and Impella 5.0/LD was implanted in 25 patients (mean age: 62 ± 9 years, male 84.0%). There was greater stability of device position (p = .033), less incidence of hemolysis (p < .001), and less frequent need for additional MCS (p = .001) in patients implanted with the Impella 5.0/LD compared with Impella CP in this study cohort. Patients with Impella 5.0/LD were more likely to survive from Impella and survive to discharge. CONCLUSIONS: This study suggests that for patients who require temporary MCS for more than 24 h, the Impella 5.0/LD may have a more favorable device-specific adverse profile compared with the Impella CP.


Subject(s)
Heart-Assist Devices , Aged , Heart-Assist Devices/adverse effects , Hospital Mortality , Humans , Male , Middle Aged , Retrospective Studies , Shock, Cardiogenic/therapy , Treatment Outcome
15.
Neurocrit Care ; 31(1): 72-80, 2019 08.
Article in English | MEDLINE | ID: mdl-30644037

ABSTRACT

BACKGROUND: Infection has been associated with stroke in patients with left ventricular assist devices (LVAD); however, little data exist on the timing, type and mortality impact of infection-related stroke. METHODS: Prospectively collected data of HeartMate II (N = 332) and HeartWare (N = 70) LVAD patients from a single center were reviewed. Only strokes (ischemic or hemorrhagic) that occurred within 6 weeks following a LVAD infection were considered in analyses. The association between LVAD infections (wound, pump pocket, driveline and/or bloodstream infection [BSI]), specific pathogens and ischemic and hemorrhagic strokes was evaluated using multivariable logistic regression analysis. The impact of infection-related stroke on cumulative survival was assessed using Kaplan-Meier analysis. RESULTS: Of 402 patients, LVAD infection occurred in 158 (39%) including BSI in 107 (27%), driveline infection in 67 (17%), wound infection in 31 (8%) and pump pocket infection in 24 (6%). LVAD infection-related stroke occurred in 20/158 (13%) patients in a median of 4 days (0-36 days) from documented infection. In multivariable analysis, ischemic stroke was associated with wound infection (aOR 9.0, 95% CI 2.4-34.0, P = 0.001) and BSI (aOR 7.7, 95% CI 0.9-66.0, P = 0.064), and hemorrhagic stroke was associated with BSI in 100% of cases (P = 0.01). There was no association with driveline or pump pocket infection. The cumulative survival rate among patients with infection-related stroke was significantly lower compared to those with LVAD infection but no stroke (log-rank P < 0.001). There was a trend toward shorter stroke-free survival among patients with LVAD infection. CONCLUSIONS: LVAD infections, particularly BSI, are significantly associated with stroke, and infection-related stroke conferred significantly lower cumulative survival.


Subject(s)
Heart Failure/therapy , Heart-Assist Devices/adverse effects , Prosthesis-Related Infections/complications , Stroke/epidemiology , Surgical Wound Infection/complications , Adult , Aged , Female , Heart Failure/complications , Heart Failure/mortality , Humans , Logistic Models , Male , Middle Aged , Prosthesis-Related Infections/mortality , Retrospective Studies , Risk Factors , Surgical Wound Infection/mortality , Survival Rate
16.
J Card Surg ; 34(12): 1569-1572, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31654576

ABSTRACT

OBJECTIVES: Patients with low left ventricular ejection fraction (LVEF) undergoing high-risk coronary artery bypass grafting (CABG) are at increased risk for postcardiotomy cardiogenic shock. This report describes planned concomitant microaxial temporary mechanical support (MA-TMS) device placement as a viable bridge-to-recovery strategy for high-risk patients receiving surgical revascularization. METHODS: A retrospective review was performed for all patients from October 2017 to May 2019 with low LVEF (<30%), New York Heart Association Class III or IV symptoms, and myocardial viability who underwent CABG with prophylactic MA-TMS support at a single institution (n = 13). RESULTS: Mean patient age was 64.8 years, and 12 patients (92%) were male. Eight patients (62%) presented with acute coronary syndrome. Mean predicted risk of mortality was 4.6%, ranging from 0.6% to 15.6%. An average of 3.4 grafts were performed per patient. Greater than 60% of patients were extubated within 48 hours and out-of-bed within 72 hours, and the average duration of MA-TMS was 5.7 days. Mean postoperative length of stay was 16.7 days. There were no postoperative myocardial infarctions or deaths. CONCLUSIONS: Prophylactic MA-TMS may allow safe and effective surgical revascularization for patients with severe left ventricular dysfunction who may otherwise be offered a durable ventricular assist device.


Subject(s)
Acute Coronary Syndrome/surgery , Assisted Circulation , Coronary Artery Bypass/adverse effects , Heart Failure/surgery , Shock, Cardiogenic/prevention & control , Ventricular Dysfunction, Left/surgery , Acute Coronary Syndrome/complications , Acute Coronary Syndrome/mortality , Aged , Female , Heart Failure/complications , Heart Failure/mortality , Humans , Male , Middle Aged , Retrospective Studies , Stroke Volume/physiology , Survival Rate , Ventricular Dysfunction, Left/complications , Ventricular Dysfunction, Left/mortality
17.
Artif Organs ; 42(2): 231-235, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29076174

ABSTRACT

The VentriFlo True Pulse Pump (Design Mentor, Inc., Pelham, NH, USA) is the first blood pump designed to mimic human arterial waveforms in a standard oxygenation circuit. Our aim was to demonstrate the feasibility and safety of this pump in preparation for future studies to determine possible clinical advantages. We studied four piglets (41.4-46.2 kg): three with an implanted VentriFlo pulsatile pump and one with the nonpulsatile ROTAFLOW pump (MAQUET Holding B.V. & Co. KG, Rastatt, Germany) as a control. Hemodynamics was monitored during 6-h cardiopulmonary bypass (CPB) support and for 2 h after weaning off CPB. The VentriFlo demonstrated physiologic arterial waveforms with arterial pulse pressure of 24.6 ± 5.7 mm Hg. Pump flows (2.0 ± 0.1 L/min in ROTAFLOW; 1.9 ± 0.1 L/min in VentriFlo) and plasma free hemoglobin levels (27.9 ± 12.5 mg/dL in ROTAFLOW; 28.5 ± 14.2 mg/dL in VentriFlo) were also comparable, but systemic O2 extraction (as measured by arterial minus venous O2 saturation) registered slightly higher with the VentriFlo (63.2 ± 6.9%) than the ROTAFLOW (55.4 ± 6.5%). Histological findings showed no evidence of ischemic changes or thromboembolism. This pilot study demonstrated that the VentriFlo system generated pulsatile flow and maintained adequate perfusion of all organs during prolonged CPB.


Subject(s)
Cardiopulmonary Bypass/instrumentation , Animals , Equipment Design , Feasibility Studies , Heart-Assist Devices , Hemodynamics , Pulsatile Flow , Swine
19.
Prog Transplant ; 28(3): 220-225, 2018 09.
Article in English | MEDLINE | ID: mdl-29879864

ABSTRACT

PURPOSE: Psychosocial assessment of patients comprises an important element in the selection process of appropriate candidates for left ventricular assist device (LVAD) implantation. We sought to determine the association of the well-validated psychosocial assessment of candidates for transplantation (PACT) scale to clinical outcomes post-LVAD implantation. MATERIALS AND METHODS: The PACT scale was used retrospectively to reconstruct psychosocial profiles of all patients who underwent a continuous-flow LVAD implantation for all indications at our institution between March 2008 and August 2012 (N = 230). Psychosocial elements including social support, psychological health, lifestyle factors, comprehension of the operation, and follow-up were evaluated. The primary outcome was overall survival, and the secondary outcomes were hospital readmission, pump thrombosis, hemolysis, gastrointestinal (GI) bleeding, and LVAD driveline infections. RESULTS: The mean age of patients was 55.3 years, with 83% being male; 58% (N = 135) were bridge to transplant and 42% (N = 95) were destination therapy. Up to 1-year post-LVAD implant, there were no statistical differences among the 5 PACT candidate groups in terms of survival ( P = .79), hospital readmissions ( P = .55), suspected or confirmed pump thrombosis ( P = .31), hemolysis ( P = .43), GI bleeding ( P = .71), or driveline infections ( P = .06). CONCLUSIONS: In this single-center retrospective review, post hoc reconstruction of psychosocial profiles using the PACT scale and independent assessment of postimplant outcomes, including survival and adverse events, did not show any association. However, given the small number of patients in the low score PACT groups as well as limited duration of follow-up, further studies are required to elucidate the association.


Subject(s)
Heart Failure/psychology , Heart Failure/therapy , Heart Transplantation/psychology , Heart-Assist Devices/psychology , Patient Selection , Psychological Tests , Adult , Aged , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies , Risk Factors , Ventricular Function, Left
20.
Curr Opin Organ Transplant ; 23(3): 295-300, 2018 06.
Article in English | MEDLINE | ID: mdl-29629994

ABSTRACT

PURPOSE OF REVIEW: Many patients suffer from either persistent right ventricular failure (RVF) at the time of left ventricular assist device (LVAD) or have ongoing symptoms consistent with RVF during chronic mechanical circulatory support. The lack of long-term right ventricular assist devices (RVADs) has limited the impact that mechanical circulatory support can provide to patients with biventricular failure. We aim to review the entire spectrum of RVF in patients receiving LVADs and reflect on why this entity remains the Achilles' heel of LVAD therapy. RECENT FINDINGS: In the early postoperative period, LVAD implantation reduces right ventricle (RV) afterload, but RV dysfunction may be exacerbated secondary to increased venous return. With prolonged therapy, the decreased RV afterload leads to improved RV contractile function. Bayesian statistical models outperform previously published preoperative risk scores by considering inter-relationships and conditional probabilities amongst independent variables. Various echocardiographic parameters and the pulmonary artery pulsatility index have shown promise in predicting post-LVAD RVF. Recent publications have delineated the emergence of 'delayed' RVF. Several devices are currently being investigated for use as RVADs. SUMMARY: Post-LVAD RVF depends on the RV's ability to adapt to acute hemodynamic changes imposed by the LVAD. Management options are limited due to the lack of an easily implantable, chronic-use RVAD.


Subject(s)
Heart Failure/therapy , Heart Ventricles/surgery , Heart-Assist Devices/adverse effects , Ventricular Dysfunction, Right/etiology , Humans
SELECTION OF CITATIONS
SEARCH DETAIL