1.
Biomed Phys Eng Express ; 9(5)2023 08 16.
Article in English | MEDLINE | ID: mdl-37536305

ABSTRACT

This research investigates the reduction in weight of hip implant by the application of parametric and non-parametric optimization techniques. Orthopaedic hip implants can be made from metals, ceramics, composites, or metallic alloys and are generally solid structures. The stiffness of orthopaedic hip implant is a pertaining problem when implanted in the human body as Hip implant are stiffer than bone material and causes stress shielding. This results in bone weakening which causes osteoporosis. Reduction in mass of femur stem results in stiffness reduction of femur stem. Non-Parametric topology optimization results in 34.9% mass reduction and parametric optimization based on Central Composite Design technique in Design of Experiments (DoE) uses hole diameters as parameters and performs structural optimization that results in 22% mass reduction.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Orthopedics , Humans , Arthroplasty, Replacement, Hip/methods , Prosthesis Design , Alloys
2.
Polymers (Basel) ; 13(20)2021 Oct 11.
Article in English | MEDLINE | ID: mdl-34685250

ABSTRACT

This paper proposes a multi-scale analysis technique based on the micromechanics of failure (MMF) to predict and investigate the damage progression and ultimate strength at failure of laminated composites. A lamina's representative volume element (RVE) is developed to predict and calculate constituent stresses. Damages that occurred in the constituents are calculated using separate failure criteria for both fiber and matrix. Subsequently, the volume-based damage homogenization technique is utilized to prevent the localization of damage throughout the total matrix zone. The proposed multiscale analysis procedure is then used to investigate the notched and unnotched behavior of three multi-directional composite layups, [30, 60, 90, -60, 30]2S, [0, 45, 90, -45]2S, and [60, 0, -60]3S, subjected to static tension and compression loading. The specimen is fabricated from unidirectionally reinforced composite (IM7/977-3). The prediction of ultimate strength at failure and equivalent stiffness are then benchmarked against the experimental test data. The comparative analysis with various failure models is also carried out to validate the proposed model. MMF demonstrated the capability to correctly predict the ultimate strength at failure for a range of multidirectional composites laminates under tensile and compressive load. The numerically predicted findings revealed a good agreement with the experimental test data. Out of the three investigated composite layups, the simulated results for the quasi-isotropic [0, 45, 90, -45]2S layup agreed extremely well with the experimental results with all the percentage errors within 10% of the measured failure loads.

SELECTION OF CITATIONS
SEARCH DETAIL