Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters

Database
Language
Publication year range
1.
J Am Coll Cardiol ; 70(5): 542-553, 2017 Aug 01.
Article in English | MEDLINE | ID: mdl-28750697

ABSTRACT

BACKGROUND: Saline irrigation improved the safety of radiofrequency (RF) ablation, but the thermal feedback for energy titration is absent. OBJECTIVES: To allow temperature-controlled irrigated ablation, a novel irrigated RF catheter was designed with a diamond-embedded tip (for rapid cooling) and 6 surface thermocouples to reflect tissue temperature. High-resolution electrograms (EGMs) from the split-tip electrode allowed rapid lesion assessment. The authors evaluated the preclinical and clinical performance of this catheter for pulmonary vein (PV) isolation. METHODS: Using the DiamondTemp (DT) catheter, pigs (n = 6) underwent discrete atrial ablation in a temperature control mode (60°C/50 W) until there was ∼80% EGM amplitude reduction. In a single-center clinical feasibility study, 35 patients underwent PV isolation with the DT catheter (study group); patients were planned for PV remapping after 3 months, regardless of symptomatology. A control group included 35 patients who underwent PV isolation with a standard force-sensing catheter. RESULTS: Porcine lesion histology revealed transmurality in 51 of 55 lesions (92.7%). In patients, all PVs were successfully isolated; no char or thrombus formation was observed. Compared with the control group, the study cohort had shorter mean RF application duration (26.3 ± 5.2 min vs. 89.2 ± 27.2 min; p < 0.001), shorter mean fluoroscopic time (11.2 ± 8.5 min vs. 19.5 ± 6.8 min; p < 0.001), and lower acute dormant PV reconduction (0 of 35 vs. 5 of 35; p = 0.024). At 3 months, 23 patients underwent remapping: 39 of 46 PV pairs (84.8%) remained durably isolated in 17 of these patients (73.9%). CONCLUSIONS: This first-in-human series demonstrated that temperature-controlled irrigated ablation produced rapid, efficient, and durable PV isolation. (ACT DiamondTemp Temperature-Controlled and Contact Sensing RF Ablation Clinical Trial for Atrial Fibrillation [TRAC-AF]; NCT02821351).


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/instrumentation , Heart Conduction System/surgery , Pulmonary Veins/surgery , Adolescent , Adult , Aged , Animals , Atrial Fibrillation/physiopathology , Electrocardiography , Equipment Design , Female , Follow-Up Studies , Heart Conduction System/physiopathology , Humans , Male , Middle Aged , Prospective Studies , Swine , Temperature , Time Factors , Treatment Outcome , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL