Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Clin Exp Dermatol ; 42(8): 881-886, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28748571

ABSTRACT

Porokeratosis, a disorder of keratinisation, is clinically characterized by the presence of annular plaques with a surrounding keratotic ridge. Clinical variants include linear, disseminated superficial actinic, verrucous/hypertrophic, disseminated eruptive, palmoplantar and porokeratosis of Mibelli (one or two typical plaques with atrophic centre and guttered keratotic rim). All of these subtypes share the histological feature of a cornoid lamella, characterized by a column of 'stacked' parakeratosis with focal absence of the granular layer, and dysmaturation (prematurely keratinised cells in the upper spinous layer). In recent years, a proposed new subtype, follicular porokeratosis (FP_, has been described, in which the cornoid lamella are exclusively located in the follicular ostia. We present four new cases that showed typical histological features of FP.


Subject(s)
Hair Follicle/pathology , Porokeratosis/pathology , Skin/pathology , Aged , Aged, 80 and over , Female , Humans , Lentigo/complications , Lentigo/pathology , Male , Middle Aged , Porokeratosis/classification , Porokeratosis/complications
2.
Lasers Med Sci ; 23(1): 59-64, 2008 Jan.
Article in English | MEDLINE | ID: mdl-17468898

ABSTRACT

Intense pulsed light systems are currently in widespread use in clinical applications. Verification of spectral content and associated pulse waveforms is, however, not featured in product support and calibration. A measurement system was developed to determine the spectral output of such sources within a series of discrete wavelength intervals. Such a system utilised a series of 11 broadband optical filters with centre wavelengths within the range 450-950 nm in circuit with silicon photodiodes as optical detectors. Signals were captured using a low cost 8-channel 16-bit universal serial bus data capture module interfaced to a laptop computer. This allowed the pulse profile of selected filter components to be separately captured and analysed. Calibration of individual filter channels was undertaken using a Bentham dmc150 spectroradiometer and reference tungsten light source. Initial measurements undertaken of the intense pulsed light output of a Lumenis One system using the system are described.


Subject(s)
Optics and Photonics/instrumentation , Phototherapy/instrumentation , Spectrum Analysis/instrumentation , Calibration , Equipment Design , Filtration/instrumentation , Signal Processing, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL