1.
Hell J Nucl Med ; 25(2): 143-147, 2022.
Article in English | MEDLINE | ID: mdl-35913861

ABSTRACT

OBJECTIVE: Dedicated multi-pinhole (MPH) collimators have been successfully tested in selected clinical investigations. The aim of our work was to report initial experiences with an MPH collimator set designed for brain perfusion single photon emission tomography (SPECT). SUBJECTS AND METHODS: Ten patients underwent sequential technetium-99m-hexamethylpropyleneamineoxime (99mTc-HMPAO) SPECT with a dual-head SPECT camera equipped with conventional low-energy parallel hole collimators (LEHR), and with a triple-head system equipped with MPH collimators. Low-energy parallel hole collimators data were reconstructed by filtered back projection (FBP), ordered subset expectation maximization (OSEM), software for tomographic image reconstruction (STIR). In addition, both the parallel hole data and MPH data were reconstructed by Tera-TomoTM 3D iterative reconstruction denoted LEHR_TT3D and MPH_TT3D, respectively. Five medical experts visually compared the reconstructed images of the five data sets and defined a ranking sequence from the lowest (1) to the highest (5) image quality. Results were compared using the Friedman test. P values below 0.05 were considered significant. RESULTS: Low-energy parallel hole collimators acquisition resulted in 5 million, while MPH acquisition in 13 million total counts with 30 and 34 minutes of acquisition time, respectively. Mean rank coefficients of the reconstruction methods were 1.96±0.52, 2.66±0.46, 2.86±0.60, 3.62±0.55, 3.9±0.68 for FBP, STIR, LEHR_TT3D, LEHR_OSEM, MPH_TT3D respectively. The differences between MPH_TT3D-FBP (P<0.01); MPH_TT3D-STIR (P<0.05); LEHR_OSEM-FBP (P<0.01) were significant. CONCLUSION: Image quality provided by MPH collimator is comparable to that provided by conventional LEHR imaging. Higher sensitivity has the potential to shorten acquisition time or to reduce the amount of administered activity.


Subject(s)
Radioisotopes , Tomography, Emission-Computed, Single-Photon , Brain , Humans , Image Processing, Computer-Assisted , Perfusion , Phantoms, Imaging , Technetium Tc 99m Exametazime
2.
Magy Onkol ; 59(1): 25-9, 2015 Mar.
Article in Hungarian | MEDLINE | ID: mdl-25763910

ABSTRACT

11C-choline has been used in the diagnosis and follow-up of patients with prostate cancer for years. Choline PET/CT has been available in human care since March, 2014 in our country. Unfortunately this examination has not been reimbursed by the National Health Insurance so far. We retrospectively analysed and assessed the results of 40 patients who underwent 11C-choline PET/CT on the basis of previous literature. As our study group was heterogeneous statistical analysis was not performed.


Subject(s)
Carbon Radioisotopes , Choline , Positron-Emission Tomography , Prostatic Neoplasms/diagnosis , Prostatic Neoplasms/metabolism , Tomography, X-Ray Computed , Aged , Carbon Radioisotopes/metabolism , Choline/metabolism , Diagnosis, Differential , Fluorodeoxyglucose F18 , Humans , Hungary , Male , Middle Aged , Positron-Emission Tomography/methods , Prostatic Neoplasms/pathology , Radiopharmaceuticals , Retrospective Studies , Tomography, X-Ray Computed/methods