Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 132
Filter
Add more filters

Publication year range
1.
Eur Heart J ; 45(20): 1831-1839, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38740526

ABSTRACT

BACKGROUND AND AIMS: Arrhythmic mitral valve prolapse (AMVP) is linked to life-threatening ventricular arrhythmias (VAs), and young women are considered at high risk. Cases of AMVP in women with malignant VA during pregnancy have emerged, but the arrhythmic risk during pregnancy is unknown. The authors aimed to describe features of women with high-risk AMVP who developed malignant VA during the perinatal period and to assess if pregnancy and the postpartum period were associated with a higher risk of malignant VA. METHODS: This retrospective international multi-centre case series included high-risk women with AMVP who experienced malignant VA and at least one pregnancy. Malignant VA included ventricular fibrillation, sustained ventricular tachycardia, or appropriate shock from an implantable cardioverter defibrillator. The authors compared the incidence of malignant VA in non-pregnant periods and perinatal period; the latter defined as occurring during pregnancy and within 6 months after delivery. RESULTS: The authors included 18 women with AMVP from 11 centres. During 7.5 (interquartile range 5.8-16.6) years of follow-up, 37 malignant VAs occurred, of which 18 were pregnancy related occurring in 13 (72%) unique patients. Pregnancy and 6 months after delivery showed increased incidence rate of malignant VA compared to the non-pregnancy period (univariate incidence rate ratio 2.66, 95% confidence interval 1.23-5.76). CONCLUSIONS: The perinatal period could impose increased risk of malignant VA in women with high-risk AMVP. The data may provide general guidance for pre-conception counselling and for nuanced shared decision-making between patients and clinicians.


Subject(s)
Mitral Valve Prolapse , Pregnancy Complications, Cardiovascular , Humans , Female , Pregnancy , Mitral Valve Prolapse/complications , Mitral Valve Prolapse/epidemiology , Retrospective Studies , Adult , Pregnancy Complications, Cardiovascular/epidemiology , Risk Factors , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/etiology , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/etiology , Puerperal Disorders/epidemiology , Puerperal Disorders/etiology , Defibrillators, Implantable , Incidence , Ventricular Fibrillation/epidemiology , Ventricular Fibrillation/etiology , Postpartum Period
2.
Circulation ; 148(1): 35-46, 2023 07 04.
Article in English | MEDLINE | ID: mdl-37199171

ABSTRACT

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Catheter Ablation , Pulmonary Veins , Humans , Female , Middle Aged , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/drug therapy , Retrospective Studies , Stroke Volume , Ventricular Function, Left , Treatment Outcome , Atrial Flutter/etiology , Registries , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
3.
Europace ; 26(7)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-39028767

ABSTRACT

Catheter ablation (CA) has become an established treatment strategy for managing recurrent ventricular tachycardias (VTs) in patients with structural heart disease. In recent years, percutaneous mechanical circulatory support (PMCS) devices have been increasingly used intra-operatively to improve the ablation outcome. One indication would be rescue therapy for patients who develop haemodynamic deterioration during the ablation. However, more efforts are focused on identifying subjects who are at high risk of such deterioration and could benefit from the pre-emptive use of the PMCS. The third reason to use PMCS could be the inability to identify diffuse substrate, especially in non-ischaemic cardiomyopathy. This paper reviews available experiences using various types of PMCS in different clinical scenarios. Although PMCS allows mapping during VT, it does not significantly influence acute outcomes and not convincingly long-term outcomes. On the contrary, the complication rate appears to be higher in PMCS cohorts. Our data suggest that even in patients with severe left ventricular dysfunction, the substrate modification can be performed without the need for general anaesthesia and risk of haemodynamic decompensation. In end-stage heart failure associated with the electrical storm, implantation of a left ventricular assist device (or PMCS with a transition to the left ventricular assist device) might be the preferred strategy before CA. In high-risk patients who are not potential candidates for these treatment options, radiotherapy could be considered as a bail-out treatment of recurrent VTs. These approaches should be studied in prospective trials.


Subject(s)
Catheter Ablation , Heart-Assist Devices , Tachycardia, Ventricular , Humans , Catheter Ablation/methods , Catheter Ablation/adverse effects , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/physiopathology , Treatment Outcome , Heart Failure/physiopathology , Heart Failure/therapy , Risk Factors , Hemodynamics
4.
Europace ; 26(7)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38988256

ABSTRACT

AIMS: A pulsed electric field (PF) energy source is a novel potential option for catheter ablation of ventricular arrhythmias (VAs) as it can create deeper lesions, particularly in scarred tissue. However, very limited data exist on its efficacy and safety. This prospective observational study reports the initial experience with VA ablation using focal PF. METHODS AND RESULTS: The study population consisted of 44 patients (16 women, aged 61 ± 14years) with either frequent ventricular premature complexes (VPCs, 48%) or scar-related ventricular tachycardia (VT, 52%). Ablation was performed using an irrigated 4 mm tip catheter and a commercially available PF generator. On average, 16 ± 15 PF applications (25 A) were delivered per patient. Acute success was achieved in 84% of patients as assessed by elimination of VPC or reaching non-inducibility of VT. In three cases (7%), a transient conduction system block was observed during PF applications remotely from the septum. Root analysis revealed that this event was caused by current leakage from the proximal shaft electrodes in contact with the basal interventricular septum. Acute elimination of VPC was achieved in 81% patients and non-inducibility of VT in 83% patients. At the 3-month follow-up, persistent suppression of the VPC was confirmed on Holter monitoring in 81% patients. In the VT group, the mean follow-up was 116 ± 75 days and a total of 52% patients remained free of any VA. CONCLUSION: Pulsed electric field catheter ablation of a broad spectrum of VA is feasible with acute high efficacy; however, the short-term follow-up is less satisfactory for patients with scar-related VT.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Ventricular Premature Complexes , Humans , Female , Middle Aged , Male , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/physiopathology , Catheter Ablation/methods , Catheter Ablation/adverse effects , Treatment Outcome , Aged , Ventricular Premature Complexes/surgery , Ventricular Premature Complexes/physiopathology , Ventricular Premature Complexes/diagnosis , Prospective Studies , Cicatrix/etiology , Electrophysiologic Techniques, Cardiac
5.
Europace ; 26(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38864730

ABSTRACT

AIMS: Patients with structural heart disease (SHD) undergoing catheter ablation (CA) for ventricular tachycardia (VT) are at considerable risk of periprocedural complications, including acute haemodynamic decompensation (AHD). The PAINESD score was proposed to predict the risk of AHD. The goal of this study was to validate the PAINESD score using the retrospective analysis of data from a large-volume heart centre. METHODS AND RESULTS: Patients who had their first radiofrequency CA for SHD-related VT between August 2006 and December 2020 were included in the study. Procedures were mainly performed under conscious sedation. Substrate mapping/ablation was performed primarily during spontaneous rhythm or right ventricular pacing. A purposely established institutional registry for complications of invasive procedures was used to collect all periprocedural complications that were subsequently adjudicated using the source medical records. Acute haemodynamic decompensation triggered by CA procedure was defined as intraprocedural or early post-procedural (<12 h) development of acute pulmonary oedema or refractory hypotension requiring urgent intervention. The study cohort consisted of 1124 patients (age, 63 ± 13 years; males, 87%; ischaemic cardiomyopathy, 67%; electrical storm, 25%; New York Heart Association Class, 2.0 ± 1.0; left ventricular ejection fraction, 34 ± 12%; diabetes mellitus, 31%; chronic obstructive pulmonary disease, 12%). Their PAINESD score was 11.4 ± 6.6 (median, 12; interquartile range, 6-17). Acute haemodynamic decompensation complicated the CA procedure in 13/1124 = 1.2% patients and was not predicted by PAINESD score with AHD rates of 0.3, 1.8, and 1.1% in subgroups by previously published PAINESD terciles (<9, 9-14, and >14). However, the PAINESD score strongly predicted mortality during the follow-up. CONCLUSION: Primarily substrate-based CA of SHD-related VT performed under conscious sedation is associated with a substantially lower rate of AHD than previously reported. The PAINESD score did not predict these events. The application of the PAINESD score to the selection of patients for pre-emptive mechanical circulatory support should be reconsidered.


Subject(s)
Catheter Ablation , Hemodynamics , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/diagnosis , Male , Female , Middle Aged , Catheter Ablation/adverse effects , Retrospective Studies , Cicatrix/physiopathology , Aged , Hypotension/etiology , Hypotension/physiopathology , Hypotension/diagnosis , Pulmonary Edema/etiology , Pulmonary Edema/diagnosis , Pulmonary Edema/physiopathology , Postoperative Complications/etiology , Postoperative Complications/diagnosis , Risk Factors
6.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38584468

ABSTRACT

AIMS: Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. METHODS AND RESULTS: After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 s per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 ± 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 ± 21.6, 10.0 ± 6.0, 19.1 ± 9.3, and 5.7 ± 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort. CONCLUSION: Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.


Subject(s)
Atrial Fibrillation , Cardiac Catheters , Catheter Ablation , Pulmonary Veins , Recurrence , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Catheter Ablation/methods , Catheter Ablation/instrumentation , Male , Female , Middle Aged , Aged , Treatment Outcome , Equipment Design , Electrophysiologic Techniques, Cardiac , Time Factors , Heart Rate , Action Potentials
7.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38584423

ABSTRACT

Electrical storm (ES) is a state of electrical instability, manifesting as recurrent ventricular arrhythmias (VAs) over a short period of time (three or more episodes of sustained VA within 24 h, separated by at least 5 min, requiring termination by an intervention). The clinical presentation can vary, but ES is usually a cardiac emergency. Electrical storm mainly affects patients with structural or primary electrical heart disease, often with an implantable cardioverter-defibrillator (ICD). Management of ES requires a multi-faceted approach and the involvement of multi-disciplinary teams, but despite advanced treatment and often invasive procedures, it is associated with high morbidity and mortality. With an ageing population, longer survival of heart failure patients, and an increasing number of patients with ICD, the incidence of ES is expected to increase. This European Heart Rhythm Association clinical consensus statement focuses on pathophysiology, clinical presentation, diagnostic evaluation, and acute and long-term management of patients presenting with ES or clustered VA.


Subject(s)
Defibrillators, Implantable , Heart Failure , Tachycardia, Ventricular , Humans , Risk Factors , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Incidence , Heart Failure/complications , Asia/epidemiology , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/therapy , Tachycardia, Ventricular/complications
8.
J Cardiovasc Electrophysiol ; 34(9): 1885-1895, 2023 09.
Article in English | MEDLINE | ID: mdl-37529864

ABSTRACT

INTRODUCTION: Observational studies have shown low bleeding rates in patients with atrial fibrillation (AF) treated by left atrial appendage closure (LAAC); however, data from randomized studies are lacking. This study compared bleeding events among patients with AF treated by LAAC and nonvitamin K anticoagulants (NOAC). METHODS: The Prague-17 trial was a prospective, multicenter, randomized trial that compared LAAC to NOAC in high-risk AF patients. The primary endpoint was a composite of a cardioembolic event, cardiovascular death, and major and clinically relevant nonmajor bleeding (CRNMB) defined according to the International Society on Thrombosis and Hemostasis (ISTH). RESULTS: The trial enrolled 402 patients (201 per arm), and the median follow-up was 3.5 (IQR 2.6-4.2) years. Bleeding occurred in 24 patients (29 events) and 32 patients (40 events) in the LAAC and NOAC groups, respectively. Six of the LAAC bleeding events were procedure/device-related. In the primary intention-to-treat analysis, LAAC was associated with similar rates of ISTH major or CRNMB (sHR 0.75, 95% CI 0.44-1.27, p = 0.28), but with a reduction in nonprocedural major or CRNMB (sHR 0.55, 95% CI 0.31-0.97, p = 0.039). This reduction for nonprocedural bleeding with LAAC was mainly driven by a reduced rate of CRNMB (sHR for major bleeding 0.69, 95% CI 0.34-1.39, p = .30; sHR for CRNMB 0.43, 95% CI 0.18-1.03, p = 0.059). History of bleeding was a predictor of bleeding during follow-up. Gastrointestinal bleeding was the most common bleeding site in both groups. CONCLUSION: During the 4-year follow-up, LAAC was associated with less nonprocedural bleeding. The reduction is mainly driven by a decrease in CRNMB.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Humans , Anticoagulants/adverse effects , Stroke/diagnosis , Stroke/etiology , Stroke/prevention & control , Atrial Appendage/surgery , Prospective Studies , Treatment Outcome , Hemorrhage/chemically induced , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy
9.
Europace ; 25(4): 1284-1295, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36879464

ABSTRACT

The EU Horizon 2020 Framework-funded Standardized Treatment and Outcome Platform for Stereotactic Therapy Of Re-entrant tachycardia by a Multidisciplinary (STOPSTORM) consortium has been established as a large research network for investigating STereotactic Arrhythmia Radioablation (STAR) for ventricular tachycardia (VT). The aim is to provide a pooled treatment database to evaluate patterns of practice and outcomes of STAR and finally to harmonize STAR within Europe. The consortium comprises 31 clinical and research institutions. The project is divided into nine work packages (WPs): (i) observational cohort; (ii) standardization and harmonization of target delineation; (iii) harmonized prospective cohort; (iv) quality assurance (QA); (v) analysis and evaluation; (vi, ix) ethics and regulations; and (vii, viii) project coordination and dissemination. To provide a review of current clinical STAR practice in Europe, a comprehensive questionnaire was performed at project start. The STOPSTORM Institutions' experience in VT catheter ablation (83% ≥ 20 ann.) and stereotactic body radiotherapy (59% > 200 ann.) was adequate, and 84 STAR treatments were performed until project launch, while 8/22 centres already recruited VT patients in national clinical trials. The majority currently base their target definition on mapping during VT (96%) and/or pace mapping (75%), reduced voltage areas (63%), or late ventricular potentials (75%) during sinus rhythm. The majority currently apply a single-fraction dose of 25 Gy while planning techniques and dose prescription methods vary greatly. The current clinical STAR practice in the STOPSTORM consortium highlights potential areas of optimization and harmonization for substrate mapping, target delineation, motion management, dosimetry, and QA, which will be addressed in the various WPs.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Prospective Studies , Arrhythmias, Cardiac , Heart Ventricles , Catheter Ablation/adverse effects , Catheter Ablation/methods , Treatment Outcome
10.
Europace ; 25(3): 1025-1034, 2023 03 30.
Article in English | MEDLINE | ID: mdl-36635857

ABSTRACT

AIMS: Little is known about patients with right bundle branch block (RBBB)-ventricular tachycardia (VT) and arrhythmogenic cardiomyopathy (ACM). Our aims were: (i) to describe electrocardiogram (ECG) characteristics of sinus rhythm (SR) and VT; (ii) to correlate SR with RBBB-VT ECGs; and (iii) to compare VT ECGs with electro-anatomic mapping (EAM) data. METHODS AND RESULTS: From the European Survey on ACM, 70 patients with spontaneous RBBB-VT were included. Putative left ventricular (LV) sites of origin (SOOs) were estimated with a VT-axis-derived methodology and confirmed by EAM data when available. Overall, 49 (70%) patients met definite Task Force Criteria. Low QRS voltage predominated in lateral leads (n = 37, 55%), but QRS fragmentation was more frequent in inferior leads (n = 15, 23%). T-wave inversion (TWI) was equally frequent in inferior (n = 28, 42%) and lateral (n = 27, 40%) leads. TWI in inferior leads was associated with reduced LV ejection fraction (LVEF; 46 ± 10 vs. 53 ± 8, P = 0.02). Regarding SOOs, the inferior wall harboured 31 (46%) SOOs, followed by the lateral wall (n = 17, 25%), the anterior wall (n = 15, 22%), and the septum (n = 4, 6%). EAM data were available for 16 patients and showed good concordance with the putative SOOs. In all patients with superior-axis RBBB-VT who underwent endo-epicardial VT activation mapping, VT originated from the LV. CONCLUSIONS: In patients with ACM and RBBB-VT, RBBB-VTs originated mainly from the inferior and lateral LV walls. SR depolarization and repolarization abnormalities were frequent and associated with underlying variants.


Subject(s)
Cardiomyopathies , Tachycardia, Ventricular , Humans , Bundle-Branch Block , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/complications , Heart Ventricles , Electrocardiography , Cardiomyopathies/complications , Cardiomyopathies/diagnosis
11.
J Cardiovasc Electrophysiol ; 33(12): 2569-2577, 2022 12.
Article in English | MEDLINE | ID: mdl-36069129

ABSTRACT

INTRODUCTION: Atrial fibrillation (AF) is the most common sustained arrhythmia in humans. The onset of the arrhythmia can significantly impair cardiac function. This hemodynamic deterioration has been explained by several mechanisms such as the loss of atrial contraction, shortening of ventricular filling, or heart rhythm irregularity. This study sought to evaluate the relative hemodynamic contribution of each of these components during in vivo simulated human AF. METHODS: Twelve patients undergoing catheter ablation for paroxysmal AF were paced simultaneously from the proximal coronary sinus and the His bundle region according to prescribed sequences of irregular R-R intervals with the average rate of 90 and 130 bpm, which were extracted from the database of digital ECG recordings of AF from other patients. The simulated AF was compared to regular atrial pacing with spontaneous atrioventricular conduction and regular simultaneous atrioventricular pacing at the same heart rate. Beat-by-beat left atrial and left ventricular pressures, including LV dP/dT and Tau index were assessed by direct invasive measurement; beat-by-beat stroke volume and cardiac output (index) were assessed by simultaneous pulse-wave doppler intracardiac echocardiography. RESULTS: Simulated AF led to significant impairment of left ventricular systolic and diastolic function. Both loss of atrial contraction and heart rate irregularity significantly contributed to hemodynamic impairment. This effect was pronounced with increasing heart rate. CONCLUSION: Our findings strengthen the rationale for therapeutic strategies aiming at rhythm control and heart rate regularization in patients with AF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Ventricular Function, Left , Catheter Ablation/adverse effects , Hemodynamics , Heart Rate , Cardiac Pacing, Artificial
12.
Europace ; 24(4): 598-605, 2022 04 05.
Article in English | MEDLINE | ID: mdl-34791165

ABSTRACT

AIM: To describe clinical characteristics, procedural details, specific challenges, and outcomes in patients with HeartMate3™ (HM3), a left ventricular assist device system with a magnetically levitated pump, undergoing ventricular tachycardia ablation (VTA). METHODS AND RESULTS: Data were collected from patients with an HM3 system who underwent VTA in seven tertiary centres. Data included baseline patient characteristics, procedural data, mortality, and arrhythmia-free survival. The study cohort included 19 patients with cardiomyopathy presenting with ventricular tachycardia (VT) (53% with VT storm). Ventricular tachycardias were induced in 89% of patients and a total of 41 VTs were observed. Severe electromagnetic interference was present on the surface electrocardiogram. Hence, VT localization required analysis of intra-cardiac signals or the use of filter in the 40-20 Hz range. The large house pump HM3 design obscured the cannula inflow and therefore multi imaging modalities were necessary to avoid catheter entrapment in the cannula. A total of 32 VTs were mapped and were successfully ablated (31% to the anterior wall, 38% to the septum and only 9% to the inflow cannula region). Non-inducibility of any VT was reached in 11 patients (58%). Over a follow-up of 429 (interquartile range 101-692) days, 5 (26%) patients underwent a redo VT ablation due to recurrent VTA and 2 (11%) patients died. CONCLUSIONS: Ventricular tachycardia ablation in patients with HM3 is feasible and safe when done in the appropriate setup. Long-term arrhythmia-free survival is acceptable but not well predicted by non-inducibility at the end of the procedure.


Subject(s)
Cardiomyopathies , Catheter Ablation , Heart-Assist Devices , Tachycardia, Ventricular , Cardiomyopathies/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Humans , Recurrence , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Treatment Outcome
13.
Europace ; 24(8): 1256-1266, 2022 09 01.
Article in English | MEDLINE | ID: mdl-35647644

ABSTRACT

AIMS: Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS: This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65 min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION: In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Stroke , Adult , Aged , Aged, 80 and over , Atrial Fibrillation/diagnosis , Atrial Fibrillation/etiology , Atrial Fibrillation/surgery , Catheter Ablation/methods , Female , Humans , Middle Aged , Pulmonary Veins/surgery , Retrospective Studies , Stroke/etiology , Treatment Outcome , Young Adult
14.
Europace ; 24(2): 285-295, 2022 02 02.
Article in English | MEDLINE | ID: mdl-34491328

ABSTRACT

AIMS: In arrhythmogenic cardiomyopathy (ACM), sustained ventricular tachycardia (VT) typically displays a left bundle branch block (LBBB) morphology while a right bundle branch block (RBBB) morphology is rare. The present study assesses the VT morphology in ACM patients with sustained VT and their clinical and genetic characteristics. METHODS AND RESULTS: Twenty-six centres from 11 European countries provided information on 954 ACM patients who had ≥1 episode of sustained VT spontaneously documented during patients' clinical course. Arrhythmogenic cardiomyopathy was defined according to the 2010 Task Force Criteria, and VT morphology according to the QRS pattern in V1. Overall, 882 (92.5%) patients displayed LBBB-VT alone and 72 (7.5%) RBBB-VT [alone in 42 (4.4%) or in combination with LBBB-VT in 30 (3.1%)]. Male sex prevalence was 79.3%, 88.1%, and 56.7% in the LBBB-VT, RBBB-VT, and LBBB + RBBB-VT groups, respectively (P = 0.007). First RBBB-VT occurred 5 years after the first LBBB-VT (46.5 ± 14.4 vs 41.1 ± 15.8 years, P = 0.011). An implanted cardioverter-defibrillator was more frequently implanted in the RBBB-VT (92.9%) and the LBBB + RBBB-VT groups (90%) than in the LBBB-VT group (68.1%) (P < 0.001). Mutations in PKP2 predominated in the LBBB-VT (65.2%) and the LBBB + RBBB-VT (41.7%) groups while DSP mutations predominated in the RBBB-VT group (45.5%). By multivariable analysis, female sex was associated with LBBB + RBBB-VT (P = 0.011) while DSP mutations were associated with RBBB-VT (P < 0.001). After a median follow-up of 103 (51-185) months, death occurred in 106 (11.1%) patients with no intergroup difference (P = 0.176). CONCLUSION: RBBB-VT accounts for a significant proportion of sustained VTs in ACM. Sex and type of pathogenic mutations were associated with VT type, female sex with LBBB + RBBB-VT, and DSP mutation with RBBB-VT.


Subject(s)
Cardiomyopathies , Tachycardia, Ventricular , Bundle-Branch Block/diagnosis , Bundle-Branch Block/epidemiology , Bundle-Branch Block/therapy , Cardiomyopathies/complications , Cardiomyopathies/epidemiology , Cardiomyopathies/genetics , Electrocardiography , Female , Humans , Male , Prevalence , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/genetics
15.
J Cardiovasc Electrophysiol ; 32(3): 647-656, 2021 03.
Article in English | MEDLINE | ID: mdl-33428307

ABSTRACT

AIMS: Catheter ablation (CA) for atrial fibrillation (AF) has a considerable risk of procedural complications. Major vascular complications (MVCs) appear to be the most frequent. This study investigated gender differences in MVCs in patients undergoing CA for AF in a high-volume tertiary center. METHODS: A total of 4734 CAs for AF (65% paroxysmal, 26% repeated procedures) were performed at our center between January 2006 and August 2018. Patients (71% males) aged 60 ± 10 years and had a body mass index of 29 ± 4 kg/m2 at the time of the procedure. Radiofrequency point-by-point ablation was employed in 96.3% of procedures with the use of three-dimensional navigation systems and facilitated by intracardiac echocardiography. Pulmonary vein isolation was mandatory; cavotricuspid isthmus and left atrial substrate ablation were performed in 22% and 38% procedures, respectively. MVCs were defined as those that resulted in permanent injury, required intervention, or prolonged hospitalization. Their rates and risk factors were compared between genders. RESULTS: A total of 112 (2.4%) MVCs were detected: 54/1512 (3.5%) in females and 58/3222 (1.8%) in males (p < .0001). On multivariate analysis, lower body height was the only risk factor for MVCs in females (p = .0005). On the contrary, advanced age was associated with MVCs in males (p = .006). CONCLUSION: Females have a higher risk of MVCs following CA for AF compared to males. This difference is driven by lower body size in females. Low body height in females and advanced age in males are independent predictors of MVCs. Ultrasound-guided venipuncture lowered the MVC rate in males.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Female , Humans , Male , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Recurrence , Sex Factors , Treatment Outcome
16.
Europace ; 23(4): 610-615, 2021 04 06.
Article in English | MEDLINE | ID: mdl-33185243

ABSTRACT

AIMS: Catheter ablation of ventricular tachycardia (VT) is an effective treatment in patients with structural heart disease (SHD) and recurrent arrhythmias. However, the procedure is associated with the risk of complications, including both manifest and asymptomatic cerebral thromboembolic events. We hypothesized that periprocedural asymptomatic brain injury (ABI) can be reduced by using transseptal instead of the retrograde access route to the left ventricle (LV). METHODS AND RESULTS: Consecutive patients undergoing VT ablation for SHD were randomized 1:1 to either retrograde or transseptal LV access. All patients underwent radiofrequency ablation in conscious sedation with the use of an irrigated tip catheter. The degree of brain damage was evaluated by serum level of biomarker S100B. Significant ABI was defined as a post-ablation relative increase of S100B level >30%. A total of 144 patients (66 ± 9 years; 14 females; 90% coronary artery disease; LV ejection fraction: 30 ± 8%) were enrolled and 72 were allocated to each study groups. Symptomatic neurological complication of the procedure was not observed in any subject. A significant ABI was detected in 19.4% of patients. It was more commonly observed in subjects randomized to retrograde vs. transseptal LV access (26.4% vs. 12.5%, P = 0.04). In a multivariate analysis, only retrograde LV access and advanced age were independent determinants of significant ABI. CONCLUSION: Significant ABI after ablation of VT in patients with SHD can be detected in one-fifth of subjects. Retrograde access to LV is associated with a two-fold higher probability of significant ABI.


Subject(s)
Brain Injuries , Catheter Ablation , Heart Diseases , Tachycardia, Ventricular , Aged , Catheter Ablation/adverse effects , Female , Heart Ventricles , Humans , Male , Middle Aged , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Treatment Outcome
17.
Europace ; 23(12): 1989-1997, 2021 12 07.
Article in English | MEDLINE | ID: mdl-34524422

ABSTRACT

AIMS: To analyse and optimize the interobserver agreement for gross target volume (GTV) delineation on cardiac computed tomography (CCT) based on electroanatomical mapping (EAM) data acquired to guide radiotherapy for ventricular tachycardia (VT). METHODS AND RESULTS: Electroanatomical mapping data were exported and merged with the segmented CCT using manual registration by two observers. A GTV was created by both observers for predefined left ventricular (LV) areas based on preselected endocardial EAM points indicating a two-dimensional (2D) surface area of interest. The influence of (interobserver) registration accuracy and availability of EAM data on the final GTV and 2D surface location within each LV area was evaluated. The median distance between the CCT and EAM after registration was 2.7 mm, 95th percentile 6.2 mm for observer #1 and 3.0 mm, 95th percentile 7.6 mm for observer #2 (P = 0.9). Created GTVs were significantly different (8 vs. 19 mL) with lowest GTV overlap (35%) for lateral wall target areas. Similarly, the highest shift between 2D surfaces was observed for the septal LV (6.4 mm). The optimal surface registration accuracy (2.6 mm) and interobserver agreement (Δ interobserver EAM surface registration 1.3 mm) was achieved if at least three cardiac chambers were mapped, including high-quality endocardial LV EAM. CONCLUSION: Detailed EAM of at least three chambers allows for accurate co-registration of EAM data with CCT and high interobserver agreement to guide radiotherapy of VT. However, the substrate location should be taken in consideration when creating a treatment volume margin.


Subject(s)
Tachycardia, Ventricular , Heart Ventricles/diagnostic imaging , Humans , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/radiotherapy
18.
Circulation ; 139(20): 2315-2325, 2019 05 14.
Article in English | MEDLINE | ID: mdl-30929474

ABSTRACT

BACKGROUND: Ventricular fibrillation (VF) storm after myocardial infarction (MI) is a life-threatening condition that necessitates multiple defibrillations. Catheter ablation is a potentially effective treatment strategy for VF storm refractory to optimal medical treatment. However, its impact on patient survival has not been verified in a large population. METHODS: We conducted a multicenter, retrospective observational study involving consecutive patients who underwent catheter ablation of post-MI refractory VF storm without preceding monomorphic ventricular tachycardia. The target of ablation was the Purkinje-related ventricular extrasystoles triggering VF. The primary outcome was in-hospital and long-term mortalities. Univariate logistic regression and Cox proportional-hazards analysis were used to evaluate clinical characteristics associated with in-hospital and long-term mortalities, respectively. RESULTS: One hundred ten patients were enrolled (age, 65±11years; 92 men; left ventricular ejection fraction, 31±10%). VF storm occurred at the acute phase of MI (4.5±2.5 days after the onset of MI during the index hospitalization for MI) in 43 patients (39%), the subacute phase (>1 week) in 48 (44%), and the remote phase (>6 months) in 19 (17%). The focal triggers were found to originate from the scar border zone in 88 patients (80%). During in-hospital stay after ablation, VF storm subsided in 92 patients (84%). Overall, 30 (27%) in-hospital deaths occurred. The duration from the VF occurrence to the ablation procedure was associated with in-hospital mortality (odds ratio for each 1-day increase, 1.11 [95% CI, 1.03-1.20]; P=0.008). During follow-up after discharge from hospital, only 1 patient developed recurrent VF storm. However, 29 patients (36%) died, with a median survival time of 2.2 years (interquartile range, 1.2-5.5 years). Long-term mortality was associated with left ventricular ejection fraction <30% (hazard ratio, 2.54 [95% CI, 1.21-5.32]; P=0.014), New York Heart Association class ≥III (hazard ratio, 2.68 [95% CI, 1.16-6.19]; P=0.021), a history of atrial fibrillation (hazard ratio, 3.89 [95% CI, 1.42-10.67]; P=0.008), and chronic kidney disease (hazard ratio, 2.74 [95% CI, 1.15-6.49]; P=0.023). CONCLUSIONS: In patients with MI presenting with focally triggered VF storm, catheter ablation of culprit triggers is lifesaving and appears to be associated with short- and long-term freedom from recurrent VF storm. Mortality over the long-term follow-up is associated with the severity of underlying cardiovascular disease and comorbidities in this specific patient population.


Subject(s)
Catheter Ablation/methods , Myocardial Infarction/complications , Ventricular Fibrillation/therapy , Aged , Female , Follow-Up Studies , Hospital Mortality , Humans , Male , Middle Aged , Proportional Hazards Models , Purkinje Fibers/physiopathology , Recurrence , Retrospective Studies , Stroke Volume , Survival Analysis , Treatment Outcome , Ventricular Fibrillation/etiology , Ventricular Fibrillation/mortality , Ventricular Fibrillation/physiopathology , Ventricular Premature Complexes/complications , Ventricular Premature Complexes/physiopathology , Ventricular Premature Complexes/therapy
19.
Europace ; 22(3): 450-495, 2020 03 01.
Article in English | MEDLINE | ID: mdl-31995197

ABSTRACT

Ventricular arrhythmias are an important cause of morbidity and mortality and come in a variety of forms, from single premature ventricular complexes to sustained ventricular tachycardia and fibrillation. Rapid developments have taken place over the past decade in our understanding of these arrhythmias and in our ability to diagnose and treat them. The field of catheter ablation has progressed with the development of new methods and tools, and with the publication of large clinical trials. Therefore, global cardiac electrophysiology professional societies undertook to outline recommendations and best practices for these procedures in a document that will update and replace the 2009 EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias. An expert writing group, after reviewing and discussing the literature, including a systematic review and meta-analysis published in conjunction with this document, and drawing on their own experience, drafted and voted on recommendations and summarized current knowledge and practice in the field. Each recommendation is presented in knowledge byte format and is accompanied by supportive text and references. Further sections provide a practical synopsis of the various techniques and of the specific ventricular arrhythmia sites and substrates encountered in the electrophysiology lab. The purpose of this document is to help electrophysiologists around the world to appropriately select patients for catheter ablation, to perform procedures in a safe and efficacious manner, and to provide follow-up and adjunctive care in order to obtain the best possible outcomes for patients with ventricular arrhythmias.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Ventricular Premature Complexes , Cardiac Electrophysiology , Consensus , Humans , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery
20.
Europace ; 21(7): 1088-1095, 2019 Jul 01.
Article in English | MEDLINE | ID: mdl-31121018

ABSTRACT

AIMS: Stereotactic body radiotherapy (SBRT) for ventricular tachycardias (VTs) could be an option after failed catheter ablation. In this study, we analysed the long-term efficacy and toxicity of SBRT applied as a bail-out procedure. METHODS AND RESULTS: Patients with structural heart disease and unsuccessful catheter ablations for VTs underwent SBRT. The planning target volume (PTV) was accurately delineated using exported 3D electroanatomical maps with the delineated critical part of re-entry circuits. This was defined by detailed electroanatomic mapping and by pacing manoeuvres during the procedure. Using the implantable cardioverter-defibrillator lead as a surrogate contrast marker for respiratory movement compensation, 25 Gy was delivered to the PTV using CyberKnife. We evaluated occurrences of sustained VT, electrical storm, antitachycardia pacing, and shock; time to death; and radiation-induced events. From 2014 until March 2017, 10 patients underwent radiosurgical ablation (mean PTV, 22.15 mL; treatment duration, 68 min). After radiosurgery, four patients experienced nausea and one patient presented gradual progression of mitral regurgitation. During the follow-up (median 28 months), VT burden was reduced by 87.5% compared with baseline (P = 0.012) and three patients suffered non-arrhythmic deaths. After the blanking period, VT recurred in eight of 10 patients. The mean time to first antitachycardia pacing and shock were 6.5 and 21 months, respectively. CONCLUSION: Stereotactic body radiotherapy appears to show long-term safety and effectiveness for VT ablation in structural heart disease inaccessible to catheter ablation. We report one possible radiation-related toxicity and promising overall survival, warranting evaluation in a prospective multicentre clinical trial.


Subject(s)
Radiosurgery/methods , Tachycardia, Ventricular/radiotherapy , Aged , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Female , Follow-Up Studies , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL