Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 379
Filter
Add more filters

Publication year range
1.
Magn Reson Med ; 91(6): 2403-2416, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38263908

ABSTRACT

PURPOSE: The study aims to assess the potential of referenceless methods of EPI ghost correction to accelerate the acquisition of in vivo diffusion tensor cardiovascular magnetic resonance (DT-CMR) data using both computational simulations and data from in vivo experiments. METHODS: Three referenceless EPI ghost correction methods were evaluated on mid-ventricular short axis DT-CMR spin echo and STEAM datasets from 20 healthy subjects at 3T. The reduced field of view excitation technique was used to automatically quantify the Nyquist ghosts, and DT-CMR images were fit to a linear ghost model for correction. RESULTS: Numerical simulation showed the singular value decomposition (SVD) method is the least sensitive to noise, followed by Ghost/Object method and entropy-based method. In vivo experiments showed significant ghost reduction for all correction methods, with referenceless methods outperforming navigator methods for both spin echo and STEAM sequences at b = 32, 150, 450, and 600 smm - 2 $$ {\mathrm{smm}}^{-2} $$ . It is worth noting that as the strength of the diffusion encoding increases, the performance gap between the referenceless method and the navigator-based method diminishes. CONCLUSION: Referenceless ghost correction effectively reduces Nyquist ghost in DT-CMR data, showing promise for enhancing the accuracy and efficiency of measurements in clinical practice without the need for any additional reference scans.


Subject(s)
Echo-Planar Imaging , Image Processing, Computer-Assisted , Humans , Echo-Planar Imaging/methods , Image Processing, Computer-Assisted/methods , Signal-To-Noise Ratio , Phantoms, Imaging , Magnetic Resonance Spectroscopy , Artifacts , Brain , Algorithms
2.
J Cardiovasc Magn Reson ; : 101052, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38936803

ABSTRACT

BACKGROUND: In-vivo diffusion tensor CMR (DT-CMR) is an emerging technique for microstructural tissue characterisation in the myocardium. Most studies are performed at 3T, where higher signal to noise ratio (SNR) should benefit this signal starved method. However, a few studies have suggested that DT-CMR is possible at 1.5T, where EPI artefacts may be less severe and 1.5T hardware is more widely available. METHODS: We recruited 20 healthy volunteers and performed mid-ventricular short axis DT-CMR at 1.5 T and 3 T. Acquisitions were performed at peak systole and end-diastole using both stimulated echo acquisition mode (STEAM) and motion compensated spin-echo (MCSE) sequences at matched spatial resolutions. DT-CMR parameters were averaged over the LV and compared between 1.5 T and 3 T sequences using both datasets with and without the blow reference data included. RESULTS: Eleven (1.5T) and 12 (3T) diastolic MCSE acquisitions were rejected as the helix angle (HA) demonstrated <50% normal appearance circumferentially or the acquisition was abandoned due to poor image quality; a maximum of one acquisition was rejected for other datasets. Subjective HA map quality was significantly better at 3T than 1.5T for STEAM (p<0.05), but not for MCSE and other DT-CMR quality measures were consistent with improvements in STEAM at 3T over 1.5T. When blow data was excluded, no significant differences in mean diffusivity were observed between field strengths, but fractional anisotropy was significantly higher at 1.5T than 3T for STEAM systole (p<0.05). Absolute second eigenvector orientation (E2A, sheetlet angle) was significantly higher at 1.5T than 3T for MCSE systole and STEAM diastole, but significantly lower for STEAM systole (all p<0.05). Transmural HA distribution was less steep at 1.5T than 3T for STEAM diastole data (p<0.05). SNR in the blow images was higher at 3T than 1.5T for all acquisitions (p<0.05). CONCLUSION: While 3T provides benefits in terms of SNR, both STEAM and MCSE can be performed at 1.5T. However, MCSE is unreliable in diastole at both field strengths and STEAM benefits from the improved SNR at 3T over 1.5T. Future clinical research studies may be able to leverage the wider availability of 1.5T CMR hardware where MCSE acquisitions are desirable.

3.
AJR Am J Roentgenol ; 222(4): e2330357, 2024 04.
Article in English | MEDLINE | ID: mdl-38323782

ABSTRACT

BACKGROUND. MRI-based prognostic evaluation in patients with dilated cardiomyopathy (DCM) has historically used markers of late gadolinium enhancement (LGE) and feature tracking (FT)-derived left ventricular global longitudinal strain (LVGLS). Early data indicate that FT-derived left atrial strain (LAS) parameters, including reservoir, conduit, and booster, may also have prognostic roles in such patients. OBJECTIVE. The purpose of our study was to evaluate the prognostic utility of LAS parameters, derived from MRI FT, in patients with ischemic or nonischemic DCM, including in comparison with the traditional parameters of LGE and LVGLS. METHODS. This retrospective study included 811 patients with ischemic or nonischemic DCM (median age, 60 years; 640 men, 171 women) who underwent cardiac MRI at any of five centers. FT-derived LAS parameters and LVGLS were measured using two- and four-chamber cine images. LGE percentage was quantified. Patients were assessed for a composite outcome of all-cause mortality or heart failure hospitalization. Multivariable Cox regression analyses including demographic characteristics, cardiovascular risk factors, medications used, and a wide range of cardiac MRI parameters were performed. Kaplan-Meier analyses with log-rank tests were also performed. RESULTS. A total of 419 patients experienced the composite outcome. Patients who did, versus those who did not, experience the composite outcome had larger LVGLS (-6.7% vs -8.3%, respectively; p < .001) as well as a smaller LAS reservoir (13.3% vs 19.3%, p < .001), LAS conduit (4.7% vs 8.0%, p < .001), and LAS booster (8.1% vs 10.3%, p < .001) but no significant difference in LGE (10.1% vs 11.3%, p = .51). In multivariable Cox regression analyses, significant independent predictors of the composite outcome included LAS reservoir (HR = 0.96, p < .001) and LAS conduit (HR = 0.91, p < .001). LAS booster and LGE were not significant independent predictors in the models. LVGLS was a significant independent predictor only in a model that initially included LAS booster but not the other LAS parameters. In Kaplan-Meier analysis, all three LAS parameters were significantly associated with the composite outcome (p < .001). CONCLUSION. In this multicenter study, LAS reservoir and LAS conduit were significant independent prognostic markers in patients with ischemic or nonischemic DCM, showing greater prognostic utility than the currently applied markers of LVGLS and LGE. CLINICAL IMPACT. FT-derived LAS analysis provides incremental prognostic information in patients with DCM.


Subject(s)
Cardiomyopathy, Dilated , Magnetic Resonance Imaging, Cine , Humans , Female , Male , Cardiomyopathy, Dilated/diagnostic imaging , Middle Aged , Prognosis , Retrospective Studies , Magnetic Resonance Imaging, Cine/methods , Heart Atria/diagnostic imaging , Heart Atria/physiopathology , Aged , Myocardial Ischemia/diagnostic imaging , Contrast Media , Magnetic Resonance Imaging/methods
4.
MAGMA ; 37(2): 295-305, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38216813

ABSTRACT

OBJECTIVE: The excellent blood and fat suppression of stimulated echo acquisition mode (STEAM) can be combined with saturation recovery single-shot acquisition (SASHA) in a novel STEAM-SASHA sequence for right ventricular (RV) native T1 mapping. MATERIALS AND METHODS: STEAM-SASHA splits magnetization preparation over two cardiac cycles, nulling blood signal and allowing fat signal to decay. Breath-hold T1 mapping was performed in a T1 phantom and twice in 10 volunteers using STEAM-SASHA and a modified Look-Locker sequence at peak systole at 3T. T1 was measured in 3 RV regions, the septum and left ventricle (LV). RESULTS: In phantoms, MOLLI under-estimated while STEAM-SASHA over-estimated T1, on average by 3.0% and 7.0% respectively, although at typical 3T myocardial T1 (T1 > 1200 ms) STEAM-SASHA was more accurate. In volunteers, T1 was higher using STEAM-SASHA than MOLLI in the LV and septum (p = 0.03, p = 0.006, respectively), but lower in RV regions (p > 0.05). Inter-study, inter-observer and intra-observer coefficients of variation in all regions were < 15%. Blood suppression was excellent with STEAM-SASHA and noise floor effects were minimal. DISCUSSION: STEAM-SASHA provides accurate and reproducible T1 in the RV with excellent blood and fat suppression. STEAM-SASHA has potential to provide new insights into pathological changes in the RV in future studies.


Subject(s)
Heart Ventricles , Image Interpretation, Computer-Assisted , Humans , Heart Ventricles/diagnostic imaging , Myocardium/pathology , Heart/diagnostic imaging , Healthy Volunteers , Phantoms, Imaging , Reproducibility of Results , Magnetic Resonance Imaging
5.
Circulation ; 146(15): 1123-1134, 2022 10 11.
Article in English | MEDLINE | ID: mdl-36154167

ABSTRACT

BACKGROUND: Acute myocarditis is an inflammatory condition that may herald the onset of dilated cardiomyopathy (DCM) or arrhythmogenic cardiomyopathy (ACM). We investigated the frequency and clinical consequences of DCM and ACM genetic variants in a population-based cohort of patients with acute myocarditis. METHODS: This was a population-based cohort of 336 consecutive patients with acute myocarditis enrolled in London and Maastricht. All participants underwent targeted DNA sequencing for well-characterized cardiomyopathy-associated genes with comparison to healthy controls (n=1053) sequenced on the same platform. Case ascertainment in England was assessed against national hospital admission data. The primary outcome was all-cause mortality. RESULTS: Variants that would be considered pathogenic if found in a patient with DCM or ACM were identified in 8% of myocarditis cases compared with <1% of healthy controls (P=0.0097). In the London cohort (n=230; median age, 33 years; 84% men), patients were representative of national myocarditis admissions (median age, 32 years; 71% men; 66% case ascertainment), and there was enrichment of rare truncating variants (tv) in ACM-associated genes (3.1% of cases versus 0.4% of controls; odds ratio, 8.2; P=0.001). This was driven predominantly by DSP-tv in patients with normal LV ejection fraction and ventricular arrhythmia. In Maastricht (n=106; median age, 54 years; 61% men), there was enrichment of rare truncating variants in DCM-associated genes, particularly TTN-tv, found in 7% (all with left ventricular ejection fraction <50%) compared with 1% in controls (odds ratio, 3.6; P=0.0116). Across both cohorts over a median of 5.0 years (interquartile range, 3.9-7.8 years), all-cause mortality was 5.4%. Two-thirds of deaths were cardiovascular, attributable to worsening heart failure (92%) or sudden cardiac death (8%). The 5-year mortality risk was 3.3% in genotype-negative patients versus 11.1% for genotype-positive patients (Padjusted=0.08). CONCLUSIONS: We identified DCM- or ACM-associated genetic variants in 8% of patients with acute myocarditis. This was dominated by the identification of DSP-tv in those with normal left ventricular ejection fraction and TTN-tv in those with reduced left ventricular ejection fraction. Despite differences between cohorts, these variants have clinical implications for treatment, risk stratification, and family screening. Genetic counseling and testing should be considered in patients with acute myocarditis to help reassure the majority while improving the management of those with an underlying genetic variant.


Subject(s)
Cardiomyopathy, Dilated , Myocarditis , Adult , Cardiomyopathy, Dilated/genetics , Female , Heart , Humans , Male , Middle Aged , Myocarditis/diagnosis , Myocarditis/genetics , Stroke Volume , Ventricular Function, Left
6.
Magn Reson Med ; 90(4): 1641-1656, 2023 10.
Article in English | MEDLINE | ID: mdl-37415339

ABSTRACT

PURPOSE: To study the sensitivity of diffusion tensor cardiovascular magnetic resonance (DT-CMR) to microvascular perfusion and changes in cell permeability. METHODS: Monte Carlo (MC) random walk simulations in the myocardium have been performed to simulate self-diffusion of water molecules in histology-based media with varying extracellular volume fraction (ECV) and permeable membranes. The effect of microvascular perfusion on simulations of the DT-CMR signal has been incorporated by adding the contribution of particles traveling through an anisotropic capillary network to the diffusion signal. The simulations have been performed considering three pulse sequences with clinical gradient strengths: monopolar stimulated echo acquisition mode (STEAM), monopolar pulsed-gradient spin echo (PGSE), and second-order motion-compensated spin echo (MCSE). RESULTS: Reducing ECV intensifies the diffusion restriction and incorporating membrane permeability reduces the anisotropy of the diffusion tensor. Widening the intercapillary velocity distribution results in increased measured diffusion along the cardiomyocytes long axis when the capillary networks are anisotropic. Perfusion amplifies the mean diffusivity for STEAM while the opposite is observed for short diffusion encoding time sequences (PGSE and MCSE). CONCLUSION: The effect of perfusion on the measured diffusion tensor is reduced using an increased reference b-value. Our results pave the way for characterization of the response of DT-CMR to microstructural changes underlying cardiac pathology and highlight the higher sensitivity of STEAM to permeability and microvascular circulation due to its longer diffusion encoding time.


Subject(s)
Diffusion Tensor Imaging , Myocardium , Diffusion Tensor Imaging/methods , Myocardium/pathology , Myocytes, Cardiac , Diffusion Magnetic Resonance Imaging , Perfusion , Magnetic Resonance Spectroscopy
7.
J Magn Reson Imaging ; 57(3): 774-788, 2023 03.
Article in English | MEDLINE | ID: mdl-35713958

ABSTRACT

BACKGROUND: Measurement of ventricular volumes and function using MRI is an important tool in pediatric congenital heart disease. However, normal values for children are sparce and analysis methods are inconsistent. PURPOSE: To propose biventricular reference values in children for two MRI postprocessing (contouring) techniques. STUDY TYPE: Retrospective. SUBJECTS: A total of 154 children from two institutions (13.9 ± 2.8 years; 101 male) that were referred for a clinical MRI study. FIELD STRENGTH/SEQUENCE: 1.5 T; balanced steady-state free precession (bSSFP) sequence. ASSESSMENT: Left ventricular (LV) and right ventricular (RV) end-diastolic and end-systolic volumes (LVEDV, LVESV, RVEDV, RVESV) and end-diastolic and end-systolic myocardial mass (LVEDMM, LVESMM, RVEDMM, RVESMM) were measured from short-axis images using two contouring techniques: 1) papillary muscles, trabeculations and the moderator band were included in the ventricular blood volume and excluded from the myocardial mass, 2) papillary muscles, trabeculations and the moderator band were excluded from the ventricular volume and included in the ventricular mass. STATISTICAL TESTS: Univariable and multivariable linear regression models were used to evaluate relationships between sex, weight, height, body surface area (BSA) and age and volumetric results. Reference graphs and tables were created with the LMS-method. Contouring techniques were compared by intraclass correlation, regression analysis and Bland-Altman plots. A P value < 0.05 was considered statistically significant. RESULTS: Height and BSA were significantly associated with LVESV (method 1) and with LVEDV and RVEDV (method 2). LVESV (method 2), RVESV (both methods), RVEDV (method 1), and LVEDMM and RVEDMM (both methods), showed significant associations with height and weight. LVSV and RVSV (both methods) were significantly associated with BSA and weight. RVESV (method 1) was significantly associated with age. Gender showed significant associations for all parameters. DATA CONCLUSION: The proposed pediatric reference values can be used in the diagnosis and follow-up of congenital or acquired heart disease and for research purposes. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 2.


Subject(s)
Heart Defects, Congenital , Magnetic Resonance Imaging , Humans , Male , Child , Reference Values , Retrospective Studies , Stroke Volume , Magnetic Resonance Imaging/methods , Heart Ventricles/diagnostic imaging , Magnetic Resonance Spectroscopy , Magnetic Resonance Imaging, Cine/methods , Ventricular Function, Left , Reproducibility of Results
8.
J Magn Reson Imaging ; 57(2): 532-542, 2023 02.
Article in English | MEDLINE | ID: mdl-35535720

ABSTRACT

BACKGROUND: Measurement of atrial volumes by MRI is becoming increasingly important in pediatric cardiac disorders. However, MRI normal values for atrial volumes in children are lacking. PURPOSE: To establish pediatric reference values for atrial volumes. STUDY TYPE: Retrospective. SUBJECTS: A total of 155 healthy children from two large institutions (103 male, age 13.9 ± 2.8 years, range 4-18 years). FIELD STRENGTH/SEQUENCE: A 1.5 T; balanced steady-state free precession (bSSFP) sequence. ASSESSMENT: The monoplane and biplane area-length methods were used to measure minimal and maximal left and right atrial volumes (LAmin , LAmax , RAmin , and RAmax ) from four-chamber (4ch) and two-chamber (2ch) MR cine images. Centile charts and tables for atrial volumes were created. STATISTICAL TESTS: Descriptive statistics, lambda-mu-sigma (LMS)-method of Cole and Green, univariable and multivariable linear regression models. A P value < 0.05 was considered to be statistically significant. RESULTS: In the multivariable linear model, body surface area was significantly associated with all atrial volumes and sex was significantly associated with RA volumes, LA volumes measured in the 2ch-view as well as biplane LAmax. Average atrial volumes measured: monoplane 4ch: LAmin 13.1 ± 4.8 mL/m2 , LAmax 33.4 ± 8.8 mL/m2 , RAmin 18.5 ± 6.8 mL/m2 , RAmax 33.2 ± 9.6 mL/m2 ; monoplane 2ch: LAmin 12.7 ± 4.9 mL/m2 , LAmax 30.5 ± 9.5 mL/m2 ; biplane: LAmin 12.3 ± 4.5 mL/m2 , LAmax 30.9 ± 8.7 mL/m2 . DATA CONCLUSION: Pediatric MRI reference values for atrial volumes have been provided. TECHNICAL EFFICACY: 2 EVIDENCE LEVEL: 4.


Subject(s)
Heart Diseases , Magnetic Resonance Imaging , Humans , Child , Male , Child, Preschool , Adolescent , Reference Values , Retrospective Studies , Magnetic Resonance Imaging/methods , Heart Atria/diagnostic imaging , Magnetic Resonance Imaging, Cine/methods
9.
J Cardiovasc Magn Reson ; 25(1): 16, 2023 03 30.
Article in English | MEDLINE | ID: mdl-36991474

ABSTRACT

BACKGROUND: Cine Displacement Encoding with Stimulated Echoes (DENSE) facilitates the quantification of myocardial deformation, by encoding tissue displacements in the cardiovascular magnetic resonance (CMR) image phase, from which myocardial strain can be estimated with high accuracy and reproducibility. Current methods for analyzing DENSE images still heavily rely on user input, making this process time-consuming and subject to inter-observer variability. The present study sought to develop a spatio-temporal deep learning model for segmentation of the left-ventricular (LV) myocardium, as spatial networks often fail due to contrast-related properties of DENSE images. METHODS: 2D + time nnU-Net-based models have been trained to segment the LV myocardium from DENSE magnitude data in short- and long-axis images. A dataset of 360 short-axis and 124 long-axis slices was used to train the networks, from a combination of healthy subjects and patients with various conditions (hypertrophic and dilated cardiomyopathy, myocardial infarction, myocarditis). Segmentation performance was evaluated using ground-truth manual labels, and a strain analysis using conventional methods was performed to assess strain agreement with manual segmentation. Additional validation was performed using an externally acquired dataset to compare the inter- and intra-scanner reproducibility with respect to conventional methods. RESULTS: Spatio-temporal models gave consistent segmentation performance throughout the cine sequence, while 2D architectures often failed to segment end-diastolic frames due to the limited blood-to-myocardium contrast. Our models achieved a DICE score of 0.83 ± 0.05 and a Hausdorff distance of 4.0 ± 1.1 mm for short-axis segmentation, and 0.82 ± 0.03 and 7.9 ± 3.9 mm respectively for long-axis segmentations. Strain measurements obtained from automatically estimated myocardial contours showed good to excellent agreement with manual pipelines, and remained within the limits of inter-user variability estimated in previous studies. CONCLUSION: Spatio-temporal deep learning shows increased robustness for the segmentation of cine DENSE images. It provides excellent agreement with manual segmentation for strain extraction. Deep learning will facilitate the analysis of DENSE data, bringing it one step closer to clinical routine.


Subject(s)
Magnetic Resonance Imaging, Cine , Magnetic Resonance Imaging , Humans , Reproducibility of Results , Magnetic Resonance Imaging, Cine/methods , Predictive Value of Tests , Myocardium/pathology , Neural Networks, Computer , Magnetic Resonance Spectroscopy
10.
AJR Am J Roentgenol ; 220(4): 524-538, 2023 04.
Article in English | MEDLINE | ID: mdl-36321987

ABSTRACT

BACKGROUND. Prior small single-center studies have yielded conflicting results regarding the prognostic significance of myocardial strain parameters derived from feature tracking (FT) on cardiac MRI in patients with dilated cardiomyopathy (DCM). OBJECTIVE. The purpose of this study was to evaluate the prognostic utility of FT parameters on cardiac MRI in patients with ischemic and nonischemic DCM and to determine the optimal strain parameter for outcome prediction. METHODS. This retrospective study included 471 patients (median age, 61 years; 365 men, 106 women) with ischemic (n = 233) or nonischemic (n = 238) DCM and left ventricular (LV) ejection fraction (EF) less than 50% who underwent cardiac MRI at any of four centers from January 2011 to December 2019. Cardiac MRI parameters were determined by manual contouring. In addition, software-based FT was used to calculate six myocardial strain parameters (LV and right ventricular [RV] global radial strain, global circumferential strain, and global longitudinal strain [GLS]). Late gadolinium enhancement (LGE) was also evaluated. Patients were assessed for a composite outcome of all-cause mortality and/or heart-failure hospitalization. Cox regression models were used to determine associations between strain parameters and the composite outcome. RESULTS. Mean LV EF was 27.5% and mean LV GLS was -6.9%. The median follow-up period was 1328 days. The composite outcome occurred in 220 patients (125 deaths, 95 heart-failure hospitalizations). All six myocardial strain parameters were significant independent predictors of the composite outcome (hazard ratio [HR] = 0.92-1.16; all p < .05). In multivariable models that included age, corrected LV and RV end-diastolic volume, LV and RV EF, and presence of LGE, the only strain parameter that was a significant independent predictor of the composite outcome was LV GLS (HR = 1.13, p = .006); LV EF and presence of LGE were not independent predictors of the composite outcome in the models (p > .05). A LV GLS threshold of -6.8% had sensitivity of 62.6% and specificity of 62.6% in predicting the composite outcome rate at 4.0 years. CONCLUSION. LV GLS, derived from FT on cardiac MRI, is a significant independent predictor of adverse outcomes in patients with DCM. CLINICAL IMPACT. This study strengthens the body of evidence supporting the clinical implementation of FT when performing cardiac MRI in patients with DCM.


Subject(s)
Cardiomyopathy, Dilated , Heart Failure , Male , Humans , Female , Middle Aged , Cardiomyopathy, Dilated/diagnostic imaging , Cardiomyopathy, Dilated/complications , Prognosis , Retrospective Studies , Contrast Media , Gadolinium , Magnetic Resonance Imaging/adverse effects , Stroke Volume , Magnetic Resonance Imaging, Cine , Predictive Value of Tests
11.
MAGMA ; 36(6): 869-876, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37202654

ABSTRACT

OBJECTIVES: Two-dimensional (2D) through-plane phase-contrast (PC) cine flow imaging assesses shunts and valve regurgitations in paediatric CMR and is considered the reference standard for Clinical quantification of blood Flow (COF). However, longer breath-holds (BH) can reduce compliance with possibly large respiratory manoeuvres altering flow. We hypothesize that reduced BH time by application of CS (Short BH quantification of Flow) (SBOF) retains accuracy while enabling faster, potentially more reliable flows. We investigate the variance between COF and SBOF cine flows. METHODS: Main pulmonary artery (MPA) and sinotubular junction (STJ) planes were acquired at 1.5 T in paediatric patients by COF and SBOF. RESULTS: 21 patients (mean age 13.9, 10-17y) were enrolled. The BH times were COF mean 11.7 s (range 8.4-20.9 s) vs SBOF mean 6.5 s (min 3.6-9.1 s). The differences and 95% CI between the COF and SBOF flows were LVSV -1.43 ± 13.6(ml/beat), LVCO 0.16 ± 1.35(l/min) and RVSV 2.95 ± 12.3(ml/beat), RVCO 0.27 ± 0.96(l/min), QP/QS were SV 0.04 ± 0.19, CO 0.02 ± 0.23. Variability between COF and SBOF did not exceed intrasession variation of COF. CONCLUSION: SBOF reduces breath-hold duration to 56% of COF. RV flow by SBOF was biased compared to COF. The variation (95% CI) between COF and SBOF was similar to the COF intrasession test-retest 95% CI.


Subject(s)
Magnetic Resonance Imaging, Cine , Magnetic Resonance Imaging , Humans , Child , Magnetic Resonance Imaging, Cine/methods , Lung , Breath Holding , Magnetic Resonance Spectroscopy , Reproducibility of Results
12.
Pediatr Radiol ; 53(5): 892-899, 2023 05.
Article in English | MEDLINE | ID: mdl-36622403

ABSTRACT

BACKGROUND: Rare cases of cardiac inflammation following vaccination for severe acute respiratory coronavirus 2 (SARS-CoV-2) have been reported. OBJECTIVE: To study paediatric patients with clinical findings of acute inflammation post coronavirus disease 2019 (COVID-19) Pfizer/BioNTech vaccination using cardiovascular magnetic resonance imaging (MRI) in acute and subacute phases. MATERIALS AND METHODS: We enrolled adolescents younger than 18 years who presented at one of two institutions between July 2021 and August 2022 with clinical and laboratory findings of acute myocarditis shortly following COVID-19 Pfizer/BioNTech vaccination. They all underwent cardiovascular MRI using the institutional myocarditis protocol. RESULTS: Five adolescents (four boys) underwent eight scans between 3 days and 109 days (mean 49 days) after the onset of symptoms following COVID-19 vaccination. Myocardial oedema appeared on short tau inversion recovery (STIR) T2-weighted images in three adolescents at presentation (3-12 days after symptom onset). In these children, the myocardial oedema/acute inflammation had resolved at follow-up cardiovascular MRI (53-68 days after first MRI). However, in all three adolescents, a persistent area of late gadolinium enhancement was evident at follow-up, suggesting post-myocarditic fibrosis. One adolescent scanned only once, 66 days after being symptomatic, had no acute inflammation but persistent fibrotic changes. This last adolescent, who underwent the first scan 109 days after symptom onset, had findings compatible with an episode of previous myocarditis, with mild ongoing regional myocardial oedema/inflammation. CONCLUSION: This study on post-vaccine myocarditis demonstrates residual lesions with persistent areas of late gadolinium enhancement/myocardial fibrosis with ongoing myocardial oedema after resolution of the initial myocardial oedema a few weeks after Pfizer/BioNTech vaccination. There is an urgent need to recognise and fully investigate the outcome of post-vaccination myocarditis.


Subject(s)
COVID-19 , Myocarditis , Male , Humans , Adolescent , Child , Myocarditis/diagnostic imaging , Myocarditis/etiology , COVID-19 Vaccines/adverse effects , Gadolinium/adverse effects , Contrast Media/adverse effects , SARS-CoV-2 , Magnetic Resonance Imaging/methods , Edema , Inflammation
13.
Eur Heart J ; 43(26): 2469-2478, 2022 07 07.
Article in English | MEDLINE | ID: mdl-34435642

ABSTRACT

AIMS: Many cardiac pacemakers and defibrillators are not approved by regulators for magnetic resonance imaging (MRI). Even following generator exchange to an approved magnetic resonance (MR)-conditional model, many systems remain classified 'non-MR conditional' due to the leads. This classification makes patient access to MRI challenging, but there is no evidence of increased clinical risk. We compared the effect of MRI on non-MR conditional and MR-conditional pacemaker and defibrillator leads. METHODS AND RESULTS: Patients undergoing clinical 1.5T MRI with pacemakers and defibrillators in three centres over 5 years were included. Magnetic resonance imaging protocols were similar for MR-conditional and non-MR conditional systems. Devices were interrogated pre- and immediately post-scan, and at follow-up, and adverse clinical events recorded. Lead parameter changes peri-scan were stratified by MR-conditional labelling. A total of 1148 MRI examinations were performed in 970 patients (54% non-MR conditional systems, 39% defibrillators, 15% pacing-dependent) with 2268 leads. There were no lead-related adverse clinical events, and no clinically significant immediate or late lead parameter changes following MRI in either MR-conditional or non-MR conditional leads. Small reductions in atrial and right ventricular sensed amplitudes and impedances were similar between groups, with no difference in the proportion of leads with parameter changes greater than pre-defined thresholds (7.1%, 95% confidence interval: 6.1-8.3). CONCLUSIONS: There was no increased risk of MRI in patients with non-MR conditional pacemaker or defibrillator leads when following recommended protocols. Standardizing MR conditions for all leads would significantly improve access to MRI by enabling patients to be scanned in non-specialist centres, with no discernible incremental risk.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Electronics , Humans , Magnetic Resonance Imaging/adverse effects , Magnetic Resonance Spectroscopy
14.
J Card Fail ; 28(6): 924-934, 2022 06.
Article in English | MEDLINE | ID: mdl-35027315

ABSTRACT

BACKGROUND: Empirical evidence suggests a strong link between exposure to air pollution and heart failure incidence, hospitalizations, and mortality, but the biological basis of this remains unclear. We sought to determine the relationship between differential air pollution levels and changes in cardiac structure and function in patients with dilated cardiomyopathy. METHODS AND RESULTS: We undertook a prospective longitudinal observational cohort study of patients in England with dilated cardiomyopathy (enrollment 2009-2015, n = 716, 66% male, 85% Caucasian) and conducted cross sectional analysis at the time of study enrollment. Annual average air pollution exposure estimates for nitrogen dioxide (NO2) and particulate matter with diameter of 2.5 µm or less (PM2.5) at enrolment were assigned to each residential postcode (on average 12 households). The relationship between air pollution and cardiac morphology was assessed using linear regression modelling. Greater ambient exposure to NO2 was associated with higher indexed left ventricular (LV) mass (4.3 g/m2 increase per interquartile range increase in NO2, 95% confidence interval 1.9-7.0 g/m2) and lower LV ejection fraction (-1.5% decrease per interquartile range increase in NO2, 95% confidence interval -2.7% to -0.2%), independent of age, sex, socioeconomic status, and clinical covariates. The associations were robust to adjustment for smoking status and geographical clustering by postcode area. The effect of air pollution on LV mass was greatest in women. These effects were specific to NO2 exposure. CONCLUSIONS: Exposure to air pollution is associated with raised LV mass and lower LV ejection fraction, with the strongest effect in women. Although epidemiological associations between air pollution and heart failure have been established and supported by preclinical studies, our findings provide novel empirical evidence of cardiac remodeling and exposure to air pollution with important clinical and public health implications.


Subject(s)
Air Pollutants , Air Pollution , Cardiomyopathy, Dilated , Heart Failure , Air Pollutants/adverse effects , Air Pollutants/analysis , Air Pollution/adverse effects , Air Pollution/analysis , Cardiomyopathy, Dilated/epidemiology , Cross-Sectional Studies , Female , Heart Failure/epidemiology , Humans , Male , Nitrogen Dioxide/adverse effects , Nitrogen Dioxide/analysis , Prospective Studies , Ventricular Remodeling
15.
NMR Biomed ; 35(7): e4692, 2022 07.
Article in English | MEDLINE | ID: mdl-35040195

ABSTRACT

Cardiac motion results in image artefacts and quantification errors in many cardiovascular magnetic resonance (CMR) techniques, including microstructural assessment using diffusion tensor cardiovascular magnetic resonance (DT-CMR). Here, we develop a CMR-compatible isolated perfused porcine heart model that allows comparison of data obtained in beating and arrested states. Ten porcine hearts (8/10 for protocol optimisation) were harvested using a donor heart retrieval protocol and transported to the remote CMR facility. Langendorff perfusion in a 3D-printed chamber and perfusion circuit re-established contraction. Hearts were imaged using cine, parametric mapping and STEAM DT-CMR at cardiac phases with the minimum and maximum wall thickness. High potassium and lithium perfusates were then used to arrest the heart in a slack and contracted state, respectively. Imaging was repeated in both arrested states. After imaging, tissue was removed for subsequent histology in a location matched to the DT-CMR data using fiducial markers. Regular sustained contraction was successfully established in six out of 10 hearts, including the final five hearts. Imaging was performed in four hearts and one underwent the full protocol, including colocalised histology. The image quality was good and there was good agreement between DT-CMR data in equivalent beating and arrested states. Despite the use of autologous blood and dextran within the perfusate, T2 mapping results, DT-CMR measures and an increase in mass were consistent with development of myocardial oedema, resulting in failure to achieve a true diastolic-like state. A contiguous stack of 313 5-µm histological sections at and a 100-µm thick section showing cell morphology on 3D fluorescent confocal microscopy colocalised to DT-CMR data were obtained. A CMR-compatible isolated perfused beating heart setup for large animal hearts allows direct comparisons of beating and arrested heart data with subsequent colocalised histology, without the need for onsite preclinical facilities.


Subject(s)
Heart Transplantation , Animals , Heart/diagnostic imaging , Humans , Magnetic Resonance Imaging, Cine , Magnetic Resonance Spectroscopy , Myocardium/pathology , Swine , Tissue Donors
16.
J Magn Reson Imaging ; 56(5): 1382-1392, 2022 11.
Article in English | MEDLINE | ID: mdl-35072310

ABSTRACT

BACKGROUND: Myocardial deformation can be assessed from routine cardiac magnetic resonance (MR) images using two-dimensional feature tracking (2D-FT). Although reference values are essential for implementation of strain imaging in clinical practice, data for the healthy pediatric age group are limited. PURPOSE: To provide pediatric MR reference values for strain and strain rate for all four heart chambers. STUDY TYPE: Retrospective. SUBJECTS: One hundred and fifty-seven healthy children from two institutions (102 male, age 4.7-18 years). FIELD STRENGTH/SEQUENCE: 1.5 T; balanced steady-state free precession sequence. ASSESSMENT: Left ventricular (LV) global and regional longitudinal, circumferential, and radial strain and strain rate as well as right ventricular (RV) and atrial global and regional longitudinal strain and strain rate were measured in two-, three-, and four-chamber views and the short axis stack. The relationships between strain parameters and age, height, weight, and gender were investigated. Age- and height-specific centile curves and tables were created for LV strain and strain rate. For all other global strain parameters, the mean was calculated as a reference. STATISTICAL TESTS: Lambda-mu-sigma (LMS)-method of Cole and Green, univariable, and multivariable linear regression models. A P value <0.05 was considered to be statistically significant. RESULTS: Age, height and weight had a significant influence on LV global strain values. These parameters also showed an influence on RV strain but only in boys (girls P = 0.12) and none of the variables had a significant influence on atrial strain (P = 0.19-0.49). Gender differences were only found for RV strain values. DATA CONCLUSION: Pediatric potential reference values for myocardial deformation parameters of both ventricles and atria are provided. The values may serve as a reference in future studies and clinical practice. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 5.


Subject(s)
Heart Ventricles , Magnetic Resonance Imaging, Cine , Adolescent , Child , Child, Preschool , Female , Heart Ventricles/diagnostic imaging , Humans , Magnetic Resonance Imaging, Cine/methods , Magnetic Resonance Spectroscopy , Male , Reference Values , Reproducibility of Results , Retrospective Studies , Ventricular Function, Left
17.
J Magn Reson Imaging ; 56(6): 1691-1704, 2022 12.
Article in English | MEDLINE | ID: mdl-35460138

ABSTRACT

BACKGROUND: In vivo cardiac diffusion tensor imaging (cDTI) characterizes myocardial microstructure. Despite its potential clinical impact, considerable technical challenges exist due to the inherent low signal-to-noise ratio. PURPOSE: To reduce scan time toward one breath-hold by reconstructing diffusion tensors for in vivo cDTI with a fitting-free deep learning approach. STUDY TYPE: Retrospective. POPULATION: A total of 197 healthy controls, 547 cardiac patients. FIELD STRENGTH/SEQUENCE: A 3 T, diffusion-weighted stimulated echo acquisition mode single-shot echo-planar imaging sequence. ASSESSMENT: A U-Net was trained to reconstruct the diffusion tensor elements of the reference results from reduced datasets that could be acquired in 5, 3 or 1 breath-hold(s) (BH) per slice. Fractional anisotropy (FA), mean diffusivity (MD), helix angle (HA), and sheetlet angle (E2A) were calculated and compared to the same measures when using a conventional linear-least-square (LLS) tensor fit with the same reduced datasets. A conventional LLS tensor fit with all available data (12 ± 2.0 [mean ± sd] breath-holds) was used as the reference baseline. STATISTICAL TESTS: Wilcoxon signed rank/rank sum and Kruskal-Wallis tests. Statistical significance threshold was set at P = 0.05. Intersubject measures are quoted as median [interquartile range]. RESULTS: For global mean or median results, both the LLS and U-Net methods with reduced datasets present a bias for some of the results. For both LLS and U-Net, there is a small but significant difference from the reference results except for LLS: MD 5BH (P = 0.38) and MD 3BH (P = 0.09). When considering direct pixel-wise errors the U-Net model outperformed significantly the LLS tensor fit for reduced datasets that can be acquired in three or just one breath-hold for all parameters. DATA CONCLUSION: Diffusion tensor prediction with a trained U-Net is a promising approach to minimize the number of breath-holds needed in clinical cDTI studies. EVIDENCE LEVEL: 4 TECHNICAL EFFICACY: Stage 1.


Subject(s)
Diffusion Tensor Imaging , Heart , Humans , Diffusion Tensor Imaging/methods , Retrospective Studies , Heart/diagnostic imaging , Breath Holding , Anisotropy
18.
Eur Radiol ; 32(4): 2581-2593, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34713331

ABSTRACT

OBJECTIVES: Cardiovascular magnetic resonance (CMR) cine imaging by compressed sensing (CS) is promising for patients unable to tolerate long breath-holding. However, the need for a steady-state free-precession (SSFP) preparation cardiac cycle for each slice extends the breath-hold duration (e.g. for 10 slices, 20 cardiac cycles) to an impractical length. We investigated a method reducing breath-hold duration by half and assessed its reliability for biventricular volume analysis in a pediatric population. METHODS: Fifty-five consecutive pediatric patients (median age 12 years, range 7-17) referred for assessment of congenital heart disease or cardiomyopathy were included. Conventional multiple breath-hold SSFP short-axis (SAX) stack cines served as the reference. Real-time CS SSFP cines were applied without the steady-state preparation cycle preceding each SAX cine slice, accepting the limitation of omitting late diastole. The total acquisition time was 1 RR interval/slice. Volumetric analysis was performed for conventional and "single-cycle-stack-advance" (SCSA) cine stacks. RESULTS: Bland-Altman analyses [bias (limits of agreement)] showed good agreement in left ventricular (LV) end-diastolic volume (EDV) [3.6 mL (- 5.8, 12.9)], LV end-systolic volume (ESV) [1.3 mL (- 6.0, 8.6)], LV ejection fraction (EF) [0.1% (- 4.9, 5.1)], right ventricular (RV) EDV [3.5 mL (- 3.34, 10.0)], RV ESV [- 0.23 mL (- 7.4, 6.9)], and RV EF [1.70%, (- 3.7, 7.1)] with a trend toward underestimating LV and RV EDVs with the SCSA method. Image quality was comparable for both methods (p = 0.37). CONCLUSIONS: LV and RV volumetric parameters agreed well between the SCSA and the conventional sequences. The SCSA method halves the breath-hold duration of the commercially available CS sequence and is a reliable alternative for volumetric analysis in a pediatric population. KEY POINTS: • Compressed sensing is a promising accelerated cardiovascular magnetic resonance imaging technique. • We omitted the steady-state preparation cardiac cycle preceding each cine slice in compressed sensing and achieved an acquisition speed of 1 RR interval/slice. • This modification called "single-cycle-stack-advance" enabled the acquisition of an entire short-axis cine stack in a single short breath hold. • When tested in a pediatric patient group, the left and right ventricular volumetric parameters agreed well between the "single-cycle-stack-advance" and the conventional sequences.


Subject(s)
Breath Holding , Magnetic Resonance Imaging, Cine , Adolescent , Child , Humans , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/methods , Reproducibility of Results , Stroke Volume , Ventricular Function, Left
19.
Eur Heart J ; 42(7): 789-797, 2021 02 14.
Article in English | MEDLINE | ID: mdl-32974648

ABSTRACT

The measurement of left ventricular ejection fraction (LVEF) is a ubiquitous component of imaging studies used to evaluate patients with cardiac conditions and acts as an arbiter for many management decisions. This follows early trials investigating heart failure therapies which used a binary LVEF cut-off to select patients with the worst prognosis, who may gain the most benefit. Forty years on, the cardiac disease landscape has changed. Left ventricular ejection fraction is now a poor indicator of prognosis for many heart failure patients; specifically, for the half of patients with heart failure and truly preserved ejection fraction (HF-PEF). It is also recognized that LVEF may remain normal amongst patients with valvular heart disease who have significant myocardial dysfunction. This emphasizes the importance of the interaction between LVEF and left ventricular geometry. Guidelines based on LVEF may therefore miss a proportion of patients who would benefit from early intervention to prevent further myocardial decompensation and future adverse outcomes. The assessment of myocardial strain, or intrinsic deformation, holds promise to improve these issues. The measurement of global longitudinal strain (GLS) has consistently been shown to improve the risk stratification of patients with heart failure and identify patients with valvular heart disease who have myocardial decompensation despite preserved LVEF and an increased risk of adverse outcomes. To complete the integration of GLS into routine clinical practice, further studies are required to confirm that such approaches improve therapy selection and accordingly, the outcome for patients.


Subject(s)
Heart Failure , Ventricular Dysfunction, Left , Heart Ventricles , Humans , Prognosis , Stroke Volume , Systole , Ventricular Function, Left
20.
J Cardiovasc Magn Reson ; 23(1): 1, 2021 01 04.
Article in English | MEDLINE | ID: mdl-33390185

ABSTRACT

BACKGROUND: Pediatric patients are becoming increasingly referred for cardiovascular magnetic resonance (CMR). Measurement of ventricular wall thickness is typically part of the assessment and can be of diagnostic importance, e.g. in arterial hypertension. However, normal values for left ventricular (LV) and right ventricular (RV) wall thickness in pediatric patients are lacking. The aim of this study was to establish pediatric centile charts for segmental LV and RV myocardial thickness in a retrospective multicenter CMR study. METHODS: CMR was performed in 161 healthy children and adolescents with an age range between 6 and 18 years from two centers in the UK and Germany as well as from a previously published CMR project of the German Competence Network for Congenital Heart Defects. LV myocardial thickness of 16 segments was measured on the short axis stack using the American Heart Association segmentation model. In addition, the thickness of the RV inferior and anterior free wall as well as biventricular mass was measured. RESULTS: The mean age (standard deviation) of the subjects was 13.6 (2.9) years, 64 (39.7%) were female. Myocardial thickness of the basal septum (basal antero- and inferoseptal wall) was 5.2 (1.1) mm, and the basal lateral wall (basal antero- and inferolateral) measured 5.1 (1.2) mm. Mid-ventricular septum (antero- and inferoseptal wall) measured 5.5 (1.2) mm, and mid-ventricular lateral wall (antero- and inferolateral wall) was 4.7 (1.2) mm. Separate centile charts for boys and girls for all myocardial segments and myocardial mass were created because gender was significantly correlated with LV myocardial thickness (p < 0.001 at basal level, p = 0.001 at midventricular level and p = 0.005 at the apex) and biventricular mass (LV, p < 0.001; RV, p < 0.001). CONCLUSION: We established CMR normal values of segmental myocardial thickness and biventricular mass in children and adolescents. Our data are of use for the detection of abnormal myocardial properties and can serve as a reference in future studies and clinical practice.


Subject(s)
Heart Ventricles/diagnostic imaging , Magnetic Resonance Imaging, Cine , Adolescent , Age Factors , Child , Female , Germany , Humans , Male , Predictive Value of Tests , Reference Values , Retrospective Studies , United Kingdom , Ventricular Function, Left , Ventricular Function, Right , Ventricular Remodeling
SELECTION OF CITATIONS
SEARCH DETAIL