Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
J Environ Monit ; 7(5): 514-8, 2005 May.
Article in English | MEDLINE | ID: mdl-15877175

ABSTRACT

An analytical procedure has been proposed for the determination of (226)Ra at the low femtogram per ml concentration level in mineral water samples using double focusing sector field ICP-MS (ICP-SFMS). For the pre-concentration and separation of radium from the matrix elements in water a tandem of a laboratory-prepared filter, based on MnO(2), and Eichrom "Sr-specific" resin was used. The recovery of the method was determined to be 70.5%. The limit of detection for (226)Ra determination was 0.02 fg ml(-1), including a pre-concentration factor of 10. In addition, uranium concentration and uranium isotope ratios were measured by ICP-SFMS. In several mineral water samples with a relatively high uranium content, (226)Ra concentrations were found between 0.7-15 fg ml(-1). The effective dose of the contribution was calculated using the radionuclide concentration and dose conversion factors from the World Health Organization, WHO (1993). Assuming a mineral water consumption of 2 l d(-1), a slightly higher calculated dose than the suggested limit for drinking water (0.1 mSv y(-1)) was found in some samples.


Subject(s)
Radon/analysis , Uranium/analysis , Water Pollutants, Radioactive/analysis , Water Supply , Environmental Monitoring/methods , Reference Values , Sensitivity and Specificity , Spectrophotometry, Atomic
2.
Anal Chem ; 77(18): 5851-60, 2005 Sep 15.
Article in English | MEDLINE | ID: mdl-16159114

ABSTRACT

Human brain proteins containing phosphorus, copper, and zinc were detected directly in protein spots in gels of a human brain sample after separation by two-dimensional gel electrophoresis using laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS). A powerful laser ablation system with cooled laser ablation chamber was coupled to a double-focusing sector field ICPMS. The separated protein spots in 2D gels were fast screened using the optimized microanalytical LA-ICPMS technique measured at medium mass resolution with a focused laser beam (wavelength, 213 nm; diameter of laser crater, 50 mum; and laser power density, 3 x 10(9) W cm(-2)) with respect to selected three essential elements. Of 176 protein spots in 2D gel from a human brain sample, phosphorus, copper, and zinc were detected in 31, 43, and 49 protein spots, respectively. For the first time, uranium as a naturally occurring radioactive element was found in 20 selected protein spots. The detection limits for P, S, Cu, Zn and U were determined in singular protein spots with 0.0013, 1.29, 0.029, 0.063, and 0.000 01 mg g(-1), respectively. A combination of LA-ICPMS with matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry (MALDI-FTICR-MS) was applied for the identification of selected protein spots from human brain protein separated by 2D gel electrophoresis. Combining MALDI-FTICR-MS for the structure analysis of metal- and phosphorus-containing human brain proteins with LA-ICPMS, the direct analysis of heteroelements on separated proteins in 2D gels can be performed. For quantification of analytical LA-ICPMS data, the number of sulfur atoms per protein (and following the sulfur concentration) determined by MALDI-FTICR-MS was used for internal standardization. From the known sulfur concentration in protein, the concentration of other heteroelements was calculated. In addition, the number of phosphorylation and the phosphorylation sites of phosphorylated proteins in the human brain sample detected by LA-ICPMS were determined by MALDI-FTICR-MS. This technique allows the study of posttranslational modifications in human brain proteins.


Subject(s)
Brain/metabolism , Copper/analysis , Mass Spectrometry/methods , Phosphorus/analysis , Proteins/analysis , Proteins/chemistry , Zinc/analysis , Copper/chemistry , Electrophoresis, Gel, Two-Dimensional , Humans , Phosphorus/chemistry , Proteins/metabolism , Zinc/chemistry
3.
Anal Bioanal Chem ; 375(4): 561-6, 2003 Feb.
Article in English | MEDLINE | ID: mdl-12610711

ABSTRACT

Inductively coupled plasma mass spectrometry (ICP-MS) is used for phosphorus determination in protein samples. A small amount of solid protein sample (down to 1 micro g) or digest (1-10 micro L) protein solution was denatured in nitric acid and hydrogen peroxide by closed-microvessel microwave digestion. Phosphorus determination was performed with an optimized analytical method using a double-focusing sector field inductively coupled plasma mass spectrometer (ICP-SFMS) and quadrupole-based ICP-MS (ICP-QMS). For quality control of phosphorus determination a certified reference material (CRM), single cell proteins (BCR 273) with a high phosphorus content of 26.8+/-0.4 mg g(-1), was analyzed. For studies on phosphorus determination in proteins while reducing the sample amount as low as possible the homogeneity of CRM BCR 273 was investigated. Relative standard deviation and measurement accuracy in ICP-QMS was within 2%, 3.5%, 11% and 12% when using CRM BCR 273 sample weights of 40 mg, 5 mg, 1 mg and 0.3 mg, respectively. The lowest possible sample weight for an accurate phosphorus analysis in protein samples by ICP-MS is discussed. The analytical method developed was applied for the analysis of homogeneous protein samples in very low amounts [1-100 micro g of solid protein sample, e.g. beta-casein or down to 1 micro L of protein or digest in solution (e.g., tau protein)]. A further reduction of the diluted protein solution volume was achieved by the application of flow injection in ICP-SFMS, which is discussed with reference to real protein digests after protein separation using 2D gel electrophoresis.The detection limits for phosphorus in biological samples were determined by ICP-SFMS down to the ng g(-1) level. The present work discusses the figure of merit for the determination of phosphorus in a small amount of protein sample with ICP-SFMS in comparison to ICP-QMS.


Subject(s)
Mass Spectrometry/methods , Phosphorus/analysis , Proteins/chemistry , Animals , Caseins/chemistry , Humans , Microchemistry/instrumentation , Microchemistry/methods , Peptide Fragments/analysis , Reproducibility of Results , Trypsin/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL