Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
Phys Rev Lett ; 131(22): 222501, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38101385

ABSTRACT

We report on the results obtained with the global CUPID-0 background model, which combines the data collected in the two measurement campaigns for a total exposure of 8.82 kg×yr of ^{82}Se. We identify with improved precision the background sources within the 3 MeV energy region, where neutrinoless double ß decay of ^{82}Se and ^{100}Mo is expected, making more solid the foundations for the background budget of the next-generation CUPID experiment. Relying on the excellent data reconstruction, we measure the two-neutrino double ß-decay half-life of ^{82}Se with unprecedented accuracy: T_{1/2}^{2ν}=[8.69±0.05(stat)_{-0.06}^{+0.09}(syst)]×10^{19} yr.

2.
Phys Rev Lett ; 129(11): 111801, 2022 Sep 09.
Article in English | MEDLINE | ID: mdl-36154394

ABSTRACT

CUPID-0, an array of Zn^{82}Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers' technology. The first project phase (March 2017-December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, ^{82}Se, to be set. After a six month long detector upgrade, CUPID-0 began its second and last phase (June 2019-February 2020). In this Letter, we describe the search for neutrinoless double beta decay of ^{82}Se with a total exposure (phase I+II) of 8.82 kg yr^{-1} of isotope. We set a limit on the half-life of ^{82}Se to the ground state of ^{82}Kr of T_{1/2}^{0ν}(^{82}Se)>4.6×10^{24} yr (90% credible interval), corresponding to an effective Majorana neutrino mass m_{ßß}<(263-545) meV. We also set the most stringent lower limits on the neutrinoless decays of ^{82}Se to the 0_{1}^{+}, 2_{1}^{+}, and 2_{2}^{+} excited states of ^{82}Kr, finding 1.8×10^{23} yr, 3.0×10^{23} yr, and 3.2×10^{23} yr (90% credible interval) respectively.

3.
BMC Gastroenterol ; 21(1): 293, 2021 Jul 14.
Article in English | MEDLINE | ID: mdl-34261434

ABSTRACT

BACKGROUND: The chronic and progressive evolution of Inflammatory Bowel Diseases (IBD), with its prototypical fluctuating trend, creates a condition of psycho-social discomfort, impacting the quality of life in terms of personal, working, and interpersonal. AIMS: In this article, we want to identify the nature and extent of the research evidence on the life experiences, the perceived engagement, the psychological, social care and welfare needs of people affected by IBD across the lifecycle. METHODS: Following the approach set out by Arksey and O'Malley and the PRISMA extension for scoping reviews, we conducted a scoping review in March 2019 and closed the review with an update in October 2019. It was performed using electronic databases covering Health and Life Sciences, Social Sciences and Medical Sciences, such as PubMed, Medline, Embase, Scopus, Cochrane, Web of Science, PsycInfo. RESULTS: We identified 95 peer-reviewed articles published from 2009 to 2019, that allowed to detection the main needs in children (psychological, need to be accepted, physical activity, feeding, parent style, support, social needs), adolescents (to understand, physical and psychological needs, protection, relational, gratitude, respect, and engagement) and adults (information, medical, psychological, social, work-related, practical, future-related, engagement). Although the literature confirms that the majority of the IBD units have planned provision for the different types of transitions, the quality and appropriateness of these services have not been assessed or audited for all the kinds of challenges across the life cycle. CONCLUSIONS: The literature shows the relevance of organizing a flexible, personalized health care process across all the critical phases of the life cycle, providing adequate benchmarks for comparison in a multidisciplinary perspective and ensuring continuity between hospital and territory.


Subject(s)
Inflammatory Bowel Diseases , Quality of Life , Adolescent , Adult , Animals , Child , Humans , Inflammatory Bowel Diseases/therapy , Life Cycle Stages , Parents , Social Support
4.
Phys Rev Lett ; 123(3): 032501, 2019 Jul 19.
Article in English | MEDLINE | ID: mdl-31386478

ABSTRACT

CUPID-0 is the first pilot experiment of CUPID, a next-generation project for the measurement of neutrinoless double beta decay (0νDBD) with scintillating bolometers. The detector, consisting of 24 enriched and 2 natural ZnSe crystals, has been taking data at Laboratori Nazionali del Gran Sasso from June 2017 to December 2018, collecting a ^{82}Se exposure of 5.29 kg×yr. In this Letter we present the phase-I results in the search for 0νDBD. We demonstrate that the technology implemented by CUPID-0 allows us to reach the lowest background for calorimetric experiments: (3.5_{-0.9}^{+1.0})×10^{-3} counts/(keV kg yr). Monitoring 3.88×10^{25} ^{82}Se nuclei×yr we reach a 90% credible interval median sensitivity of T_{1/2}^{0ν}>5.0×10^{24} yr and set the most stringent limit on the half-life of ^{82}Se 0νDBD: T_{1/2}^{0ν}>3.5×10^{24} yr (90% credible interval), corresponding to m_{ßß}<(311-638) meV depending on the nuclear matrix element calculations.

5.
Phys Rev Lett ; 123(26): 262501, 2019 Dec 31.
Article in English | MEDLINE | ID: mdl-31951429

ABSTRACT

We report on the measurement of the two-neutrino double-ß decay of ^{82}Se performed for the first time with cryogenic calorimeters, in the framework of the CUPID-0 experiment. With an exposure of 9.95 kg yr of Zn^{82}Se, we determine the two-neutrino double-ß decay half-life of ^{82}Se with an unprecedented precision level, T_{1/2}^{2ν}=[8.60±0.03(stat) _{-0.13}^{+0.19}(syst)]×10^{19} yr. The very high signal-to-background ratio, along with the detailed reconstruction of the background sources allowed us to identify the single state dominance as the underlying mechanism of such a process, demonstrating that the higher state dominance hypothesis is disfavored at the level of 5.5σ.

6.
Phys Rev Lett ; 120(23): 232502, 2018 Jun 08.
Article in English | MEDLINE | ID: mdl-29932707

ABSTRACT

We report the result of the search for neutrinoless double beta decay of ^{82}Se obtained with CUPID-0, the first large array of scintillating Zn^{82}Se cryogenic calorimeters implementing particle identification. We observe no signal in a 1.83 kg yr ^{82}Se exposure, and we set the most stringent lower limit on the 0νßß ^{82}Se half-life T_{1/2}^{0ν}>2.4×10^{24} yr (90% credible interval), which corresponds to an effective Majorana neutrino mass m_{ßß}<(376-770) meV depending on the nuclear matrix element calculations. The heat-light readout provides a powerful tool for the rejection of α particles and allows us to suppress the background in the region of interest down to (3.6_{-1.4}^{+1.9})×10^{-3} counts/(keV kg yr), an unprecedented level for this technique.

7.
Phys Rev Lett ; 108(6): 062501, 2012 Feb 10.
Article in English | MEDLINE | ID: mdl-22401058

ABSTRACT

209Bi alpha decay to the ground and to the first excited state have been recently observed for the first time with a large BGO scintillating bolometer. The half-life of 209Bi is determined to be τ(1/2)=(2.01±0.08)×10(19) yr while the branching ratio for the ground-state to ground-state transition is (98.8±0.3)%.

8.
Eur Phys J C Part Fields ; 81(8): 722, 2021.
Article in English | MEDLINE | ID: mdl-34720725

ABSTRACT

Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of α - α delayed coincidences in 232 Th and 238 U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the α decay position.

9.
Scand J Immunol ; 72(3): 198-204, 2010 Sep.
Article in English | MEDLINE | ID: mdl-20696016

ABSTRACT

Perfusion of human foetal heart with anti-Ro/SSA antibodies induces transient heart block. Anti-Ro/SSA antibodies may cross-react with T- and L-type calcium channels, and anti-p200 antibodies may cause calcium to accumulate in rat heart cells. These actions may explain a direct electrophysiological effect of these antibodies. Congenital complete heart block is the more severe manifestation of so-called "Neonatal Lupus". In clinical practice, it is important to distinguish in utero complete versus incomplete atrioventricular (AV) block, as complete AV block to date is irreversible, while incomplete AV block has been shown to be potentially reversible after fluorinated steroid therapy. Another issue is the definition of congenital AV block, as cardiologists have considered congenital blocks detected months or years after birth. We propose as congenital blocks detected in utero or within the neonatal period (0-27 days after birth). The possible detection of first degree AV block in utero, with different techniques, might be a promising tool to assess the effects of these antibodies. Other arrhythmias have been described in NL or have been linked to anti-Ro/SSA antibodies: first degree AV block, in utero and after birth, second degree (i.e. incomplete block), sinus bradycardia and QT prolongation, both in infants and in adults, ventricular arrhythmias (in adults). Overall, these arrhythmias have not a clinical relevance, but are important for research purposes.


Subject(s)
Arrhythmias, Cardiac/etiology , Infant, Newborn, Diseases/etiology , Lupus Erythematosus, Systemic/congenital , Lupus Erythematosus, Systemic/complications , Animals , Arrhythmias, Cardiac/congenital , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/immunology , Arrhythmias, Cardiac/physiopathology , Atrioventricular Block/congenital , Atrioventricular Block/diagnosis , Atrioventricular Block/etiology , Atrioventricular Block/immunology , Atrioventricular Block/physiopathology , Bradycardia/congenital , Bradycardia/etiology , Bradycardia/immunology , Bradycardia/physiopathology , Humans , Infant, Newborn , Infant, Newborn, Diseases/diagnosis , Infant, Newborn, Diseases/immunology , Infant, Newborn, Diseases/physiopathology , Long QT Syndrome/congenital , Long QT Syndrome/etiology , Long QT Syndrome/immunology , Long QT Syndrome/physiopathology , Lupus Erythematosus, Systemic/immunology
10.
Eur Phys J C Part Fields ; 78(11): 888, 2018.
Article in English | MEDLINE | ID: mdl-30881205

ABSTRACT

The CUPID-0 experiment searches for double beta decay using cryogenic calorimeters with double (heat and light) read-out. The detector, consisting of 24 ZnSe crystals 95 % enriched in 82 Se and two natural ZnSe crystals, started data-taking in 2017 at Laboratori Nazionali del Gran Sasso. We present the search for the neutrino-less double beta decay of 82 Se into the 0 1 + , 2 1 + and 2 2 + excited states of 82 Kr with an exposure of 5.74 kg · yr (2.24 × 10 25  emitters · yr). We found no evidence of the decays and set the most stringent limits on the widths of these processes: Γ ( 82 Se → 82 Kr 0 1 + )8.55 × 10 - 24  yr - 1 , Γ ( 82 Se → 82 Kr 2 1 + ) < 6.25 × 10 - 24  yr - 1 , Γ ( 82 Se → 82 Kr 2 2 + )8.25 × 10 - 24  yr - 1 (90 % credible interval).

11.
Eur Phys J C Part Fields ; 78(9): 734, 2018.
Article in English | MEDLINE | ID: mdl-30839752

ABSTRACT

The suppression of spurious events in the region of interest for neutrinoless double beta decay will play a major role in next generation experiments. The background of detectors based on the technology of cryogenic calorimeters is expected to be dominated by α particles, that could be disentangled from double beta decay signals by exploiting the difference in the emission of the scintillation light. CUPID-0, an array of enriched Zn 82 Se scintillating calorimeters, is the first large mass demonstrator of this technology. The detector started data-taking in 2017 at the Laboratori Nazionali del Gran Sasso with the aim of proving that dual read-out of light and heat allows for an efficient suppression of the α background. In this paper we describe the software tools we developed for the analysis of scintillating calorimeters and we demonstrate that this technology allows to reach an unprecedented background for cryogenic calorimeters.

12.
Eur Phys J C Part Fields ; 78(5): 428, 2018.
Article in English | MEDLINE | ID: mdl-30996670

ABSTRACT

The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of 82 Se neutrinoless double-beta decay ( 0 ν ß ß ). CUPID-0 aims at measuring a background index in the region of interest (RoI) for 0 ν ß ß at the level of 10 - 3  counts/(keV kg years), the lowest value ever measured using cryogenic detectors. CUPID-0 operates an array of Zn 82 Se scintillating bolometers coupled with bolometric light detectors, with a state of the art technology for background suppression and thorough protocols and procedures for the detector preparation and construction. In this paper, the different phases of the detector design and construction will be presented, from the material selection (for the absorber production) to the new and innovative detector structure. The successful construction of the detector lead to promising preliminary detector performance which is discussed here.

13.
Eur Phys J C Part Fields ; 76(7): 364, 2016.
Article in English | MEDLINE | ID: mdl-28280442

ABSTRACT

The R&D activity performed during the last years proved the potential of ZnSe scintillating bolometers to the search for neutrino-less double beta decay, motivating the realization of the first large-mass experiment based on this technology: CUPID-0. The isotopic enrichment in [Formula: see text]Se, the Zn[Formula: see text]Se crystals growth, as well as the light detectors production have been accomplished, and the experiment is now in construction at Laboratori Nazionali del Gran Sasso (Italy). In this paper we present the results obtained testing the first three Zn[Formula: see text]Se crystals operated as scintillating bolometers, and we prove that their performance in terms of energy resolution, background rejection capability and intrinsic radio-purity complies with the requirements of CUPID-0.

14.
Article in English | MEDLINE | ID: mdl-26705394

ABSTRACT

The LUCIFER project aims at deploying the first array of enriched scintillating bolometers for the investigation of neutrinoless double-beta decay of [Formula: see text]Se. The matrix which embeds the source is an array of ZnSe crystals, where enriched [Formula: see text]Se is used as decay isotope. The radiopurity of the initial components employed for manufacturing crystals, that can be operated as bolometers, is crucial for achieving a null background level in the region of interest for double-beta decay investigations. In this work, we evaluated the radioactive content in 2.5 kg of 96.3 % enriched [Formula: see text]Se metal, measured with a high-purity germanium detector at the Gran Sasso deep underground laboratory. The limits on internal contaminations of primordial decay chain elements of [Formula: see text]Th, [Formula: see text]U and [Formula: see text]U are respectively: [Formula: see text]61, [Formula: see text]110 and [Formula: see text]74 [Formula: see text]Bq/kg at 90 % C.L. The extremely low-background conditions in which the measurement was carried out and the high radiopurity of the [Formula: see text]Se allowed us to establish the most stringent lower limits on the half-lives of the double-beta decay of [Formula: see text]Se to 0[Formula: see text], 2[Formula: see text] and 2[Formula: see text] excited states of [Formula: see text]Kr of 3.4[Formula: see text]10[Formula: see text], 1.3[Formula: see text]10[Formula: see text] and 1.0[Formula: see text]10[Formula: see text] y, respectively, with a 90 % C.L.

15.
J Environ Radioact ; 114: 113-8, 2012 Dec.
Article in English | MEDLINE | ID: mdl-22209567

ABSTRACT

After the earthquake and the tsunami occurred in Japan on March 2011, four of the Fukushima reactors had released in air a large amount of radioactive isotopes that diffused all over the world. The presence of airborne (131)I, (134)Cs, and (137)Cs in air particulate due to this accident were detected and measured in the Low Radioactivity Laboratory operating in the Department of Environmental Sciences of the University of Milano-Bicocca. The sensitivity of the detecting apparatus is of 0.2 uBq/m(3) of air. Concentration and time distribution of these radiocontaminations ranging from a few to 400 uBq/m(3) for the (131)I and of a few tens of uBq/m(3) for the (137)Cs and (134)Cs.


Subject(s)
Air Pollutants, Radioactive/analysis , Cesium Radioisotopes/analysis , Iodine Radioisotopes/analysis , Fukushima Nuclear Accident , Italy , Japan , Radiation Monitoring
17.
Phys Rev Lett ; 96(4): 042503, 2006 Feb 03.
Article in English | MEDLINE | ID: mdl-16486813

ABSTRACT

The mixed occurrence of s-wave and p-wave contributions in a first forbidden unique Gamow-Teller beta decay has been investigated for the first time by measuring the beta environmental fine structure (BEFS) in a 187Re crystalline compound. The experiment has been carried out with an array of eight AgReO4 thermal detectors operating at a temperature of approximately 100 mK. A fit of the observed BEFS spectrum indicates the p-wave electron emission as the dominant channel. The complete understanding of the BEFS distortion of the 187Re beta decay spectrum is crucial for future experiments aiming at the precise calorimetric measurement of the antineutrino mass.

18.
Phys Rev Lett ; 95(14): 142501, 2005 Sep 30.
Article in English | MEDLINE | ID: mdl-16241648

ABSTRACT

We report the present results of CUORICINO, a search for neutrinoless double-beta (0nu betabeta) decay of 130Te. The detector is an array of 62 TeO2 bolometers with a total active mass of 40.7 kg. The array is cooled by a dilution refrigerator shielded from environmental radioactivity and energetic neutrons, operated at approximately 8 mK in the Gran Sasso Underground Laboratory. No evidence for (0nu betabeta) decay was found and a new lower limit, T(1/2)(0nu) > or = 1.8 x 10(24) yr (90% C.L.) is set, corresponding to [m(nu)] < or = 0.2 to 1.1 eV, depending on the theoretical nuclear matrix elements used in the analysis.

19.
Phys Rev Lett ; 91(16): 161802, 2003 Oct 17.
Article in English | MEDLINE | ID: mdl-14611391

ABSTRACT

High statistics calorimetric measurements of the beta spectrum of 187Re are being performed with arrays of silver perrhenate crystals operated at low temperature. After a substantial modification of the experimental setup, a new measurement with ten silver perrhenate microbolometers has been running since July 2002. The crystals have masses around 300 microg and their average FWHM energy resolution is of 28.3 eV at the beta end point. The Kurie plot collected during 4485 h x mg effective running time has an end-point energy of 2466.1+/-0.8(stat)+/-1.5(syst) eV, while the half lifetime of the decay is found to be 43.2+/-0.2(stat)+/-0.1(syst) Gy. These values are the most precise obtained so far for 187Re. The best fit value for m(2)(nu(e)) is 147+/-237(stat)+/-90(syst) eV(2), which corresponds to an upper limit for the electron antineutrino mass m(nu(e))< or =21.7 eV at 90% C.L.