Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Osteoporos Int ; 35(6): 1049-1059, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38459138

ABSTRACT

PURPOSE: This study aimed to apply a newly developed semi-automatic phantom-less QCT (PL-QCT) to measure proximal humerus trabecular bone density based on chest CT and verify its accuracy and precision. METHODS: Subcutaneous fat of the shoulder joint and trapezius muscle were used as calibration references for PL-QCT BMD measurement. A self-developed algorithm based on a convolution map was utilized in PL-QCT for semi-automatic BMD measurements. CT values of ROIs used in PL-QCT measurements were directly used for phantom-based quantitative computed tomography (PB-QCT) BMD assessment. The study included 376 proximal humerus for comparison between PB-QCT and PL-QCT. Two sports medicine doctors measured the proximal humerus with PB-QCT and PL-QCT without knowing each other's results. Among them, 100 proximal humerus were included in the inter-operative and intra-operative BMD measurements for evaluating the repeatability and reproducibility of PL-QCT and PB-QCT. RESULTS: A total of 188 patients with 376 shoulders were involved in this study. The consistency analysis indicated that the average bias between proximal humerus BMDs measured by PB-QCT and PL-QCT was 1.0 mg/cc (agreement range - 9.4 to 11.4; P > 0.05, no significant difference). Regression analysis between PB-QCT and PL-QCT indicated a good correlation (R-square is 0.9723). Short-term repeatability and reproducibility of proximal humerus BMDs measured by PB-QCT (CV: 5.10% and 3.41%) were slightly better than those of PL-QCT (CV: 6.17% and 5.64%). CONCLUSIONS: We evaluated the bone quality of the proximal humeral using chest CT through the semi-automatic PL-QCT system for the first time. Comparison between it and PB-QCT indicated that it could be a reliable shoulder BMD assessment tool with acceptable accuracy and precision. This study developed and verify a semi-automatic PL-QCT for assessment of proximal humeral bone density based on CT to assist in the assessment of proximal humeral osteoporosis and development of individualized treatment plans for shoulders.


Subject(s)
Bone Density , Cancellous Bone , Humerus , Tomography, X-Ray Computed , Humans , Bone Density/physiology , Male , Female , Middle Aged , Tomography, X-Ray Computed/methods , Aged , Reproducibility of Results , Humerus/diagnostic imaging , Humerus/physiology , Cancellous Bone/diagnostic imaging , Cancellous Bone/physiopathology , Cancellous Bone/physiology , Algorithms , Phantoms, Imaging , Adult , Osteoporosis/physiopathology , Osteoporosis/diagnostic imaging , Aged, 80 and over
2.
Lipids Health Dis ; 19(1): 246, 2020 Nov 30.
Article in English | MEDLINE | ID: mdl-33256742

ABSTRACT

This article has been retracted. Please see the Retraction Notice for more detail: https://doi.org/10.1186/s12944-020-01416-2.

4.
Lipids Health Dis ; 14: 70, 2015 Jul 14.
Article in English | MEDLINE | ID: mdl-26170203

ABSTRACT

BACKGROUND: Osteosarcoma is the most common of all the bone malignancies and accounts for 30-80% of the primary skeletal sarcomas. The overall survival rate of patients with osteosarcoma is < 20% suggesting poor prognosis. METHODS: The present study demonstrates the effect of retinoic acid chlorochalcone (RACC) incorporated glycol chitosan (GC) nanoparticle transfection in osteosarcoma cells. MG-63 and Saos-2 osteosarcoma cells were transfected with various concentrations of RACC-incorporated GC nanoparticle for 24 h. The effect on cell proliferation, Ezh2 expression, apoptosis, cell cycle arrest, cell migration and invasiveness, Akt phosphorylation and local tumour growth and metastases were studied. RESULTS: MG-63 and Saos-2 osteosarcoma cells on RACC-incorporated GC nanoparticle transfection for 24 h showed a concentration-dependent inhibition of cell proliferation. Of the various concentrations of RACC tested, the effective concentration started from 5 µM with an IC50 of 20 µM. Wound healing assay also showed that RACC-incorporated GC nanoparticles inhibited migration of tumor cells more effectively compared to the parent RA. RACC transfection resulted in inhibition of cell proliferation, Ezh2 expression inhibition, apoptosis through mitochondrial pathway by decrease in membrane potential and release of cytochrome c and cell cycle arrest in the G0/G1 phase. The invasiveness of cells treated with 5 and 20 µM RACC was decreased by 49 and 76% respectively, compared to the control. RACC-treated mice showed significantly lower number of metastases compared to that in the control mice. CONCLUSIONS: Thus, RACC-incorporated glycol chitosan nanoparticle strategy can be promising for the treatment of osteosarcoma.


Subject(s)
Chitosan/chemistry , Cyclohexanones/therapeutic use , Nanoparticles/chemistry , Osteosarcoma/drug therapy , Tretinoin/analogs & derivatives , Tretinoin/therapeutic use , Animals , Apoptosis/drug effects , Cell Cycle Checkpoints/drug effects , Cell Line, Tumor , Cell Movement , Cell Proliferation , Cyclohexanones/chemistry , Enhancer of Zeste Homolog 2 Protein , Humans , Male , Mice , Mitochondria/drug effects , Mitochondria/metabolism , Neoplasm Invasiveness , Neoplasm Metastasis , Osteosarcoma/pathology , Phosphorylation/drug effects , Polycomb Repressive Complex 2/metabolism , Proto-Oncogene Proteins c-akt/metabolism , Time Factors , Transfection , Tretinoin/chemistry
5.
World J Clin Cases ; 10(5): 1645-1653, 2022 Feb 16.
Article in English | MEDLINE | ID: mdl-35211605

ABSTRACT

BACKGROUND: Synovial chondromatosis is a disease originating from the synovium and characterized by the presence of metaplastic cartilaginous nodules in synovial cavities. The exact prevalence of synovial chondromatosis remains unknown, and the involvement of the shoulder joint is very rare. Synovial chondromatosis accompanied by subluxation of the humeral head without a history of trauma is rarely encountered, and to our knowledge, no published reports describe this condition. CASE SUMMARY: We present two cases of synovial chondromatosis in the shoulder joint, accompanied by subluxation of the humeral head, in two arthroscopically managed adult patients. We performed arthroscopic labrum fixation and removal of the loose body from the shoulder joint. To identify primary and secondary categories, pathological analysis was arranged. Clinical and radiographic evaluations at the 1-mo follow-up were satisfactory. CONCLUSION: The biomechanical function of the shoulder joint requires attention, especially following the detection of loose bodies, as observed with synovial chondroma occurring in rare sites. Arthroscopic management is successful in patients with synovial chondromatosis combined with shoulder subluxation.

6.
World J Clin Cases ; 8(21): 5487-5493, 2020 Nov 06.
Article in English | MEDLINE | ID: mdl-33269288

ABSTRACT

BACKGROUND: Patellar instability is an uncommon complication after total knee arthroplasty (TKA). Partial lateral patella facetectomy (LPF) with lateral retinaculum release treatment of patellar instability is rarely reported. CASE SUMMARY: We present a case of patellar instability 8 mo after primary TKA. Treatment of this complication was adapted to address the cause of the dislocation. To eliminate patellar instability, we restored the vastus medialis and performed LPF with lateral retinaculum release. We achieved normal patellar tracking. Clinical and radiographic evaluations at the 1-year postoperative follow-up were satisfactory. CONCLUSION: LPF with lateral retinaculum release represents a promising option to restore central patellar tracking in patients with patellar instability after TKA in cases without component malposition.

7.
Chin Med J (Engl) ; 128(12): 1579-83, 2015 Jun 20.
Article in English | MEDLINE | ID: mdl-26063357

ABSTRACT

BACKGROUND: Many clinical studies have been published involving the use of a high hip center (HHC), achieved good follow-up. However, there is a little anatomic guidance in the literature regarding the amount of bone stock available for initial implant coverage in this area of the ilium. The purpose of this study was to evaluate the thickness and width of the human ilium and related acetabular cup coverage for guiding acetabular component placement in HHC. METHODS: A total of 120 normal hips in 60 cases of adult patients from lower extremities computer tomographic angiography Digital Imaging and Communications in Medicine data were chosen for the study. After importing the data to the mimics software, we chose the cross sections every 5-mm increments from the rotational center of the hip to the cephalic of the ilium according the body sagittal axis, then we measured the thickness and width of the ilium for each cross section in axial plane, calculated the cup coverage at each chosen section. RESULTS: At the acetabular dome, the mean thickness and width of the ilium were 49.71 ± 4.88 mm and 38.92 ± 3.67 mm, respectively, whereas at 1 cm above the dome, decreased to 41.35 ± 5.13 and 31.13 ± 3.37 respectively, and 2 cm above the dome, decreased to 31.25 ± 4.04 and 26.65 ± 3.43, respectively. Acetabular cup averaged coverage for 40-, 50-, and 60-mm hemispheric shells, was 100%, 89%, and 44% at the acetabular dome, 100%, 43.7%, and 27.5% for 1 cm above the dome, and 37.5%, 21.9%, and 14.2% for 2 cm above the dome. CONCLUSIONS: HHC reconstructions within 1 cm above the acetabular dome will be an acceptable and smaller diameter prosthesis would be better.


Subject(s)
Ilium/diagnostic imaging , Adult , Aged , Cross-Sectional Studies , Female , Hip Prosthesis , Humans , Ilium/anatomy & histology , Male , Middle Aged , Radiography
8.
J Zhejiang Univ Sci B ; 15(8): 720-6, 2014 Aug.
Article in English | MEDLINE | ID: mdl-25091990

ABSTRACT

The purpose of this study was to establish a method for measuring the knee valgus angle from the anatomical and mechanical axes on three-dimensional reconstruction imaging models, and to use this method for estimating an average knee valgus angle value for northern Chinese adults. Computed tomographic angiography data in DICOM format for 128 normal femurs from 64 adult subjects were chosen for analysis. After the femur images were subjected to three-dimensional reconstruction, the deepest point in the intercondylar notch (point A), the midpoint of the medullary cavity 20 cm above the knee-joint line (point B), and the landmark of the femoral head rotation center (point C) were identified on each three-dimensional model. The knee valgus angle was defined as the angle enclosed by the distal femoral anatomical axis (line AB) and the femoral mechanical axis (line AC). The average (mean±SD) of knee valgus angle for the 128 femurs was 6.20°±1.20° (range, 3.05° to 10.64°). Significant positive correlations were found between the knee valgus angles of the right and left sides and between the knee valgus angle and age. During total knee arthroplasty, choosing a valgus cut angle of approximately 6° may achieve a good result in reestablishing the natural mechanical alignment of the lower extremity for patients of northern Chinese ethnicity. Larger valgus cut angles should be chosen for older patients.


Subject(s)
Femur/anatomy & histology , Imaging, Three-Dimensional/methods , Models, Anatomic , Adult , Aged , Angiography , Arthroplasty, Replacement, Knee , Asian People , Biomechanical Phenomena , China , Female , Femur/diagnostic imaging , Femur/physiology , Humans , Male , Middle Aged , Radiographic Image Interpretation, Computer-Assisted , Reference Values , Retrospective Studies , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL