Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 48
Filter
1.
Anal Chem ; 95(33): 12223-12231, 2023 Aug 22.
Article in English | MEDLINE | ID: mdl-37566555

ABSTRACT

The rational design and increasing industrial use of nanomaterials require a reliable characterization of their physicochemical key properties like size, size distribution, shape, and surface chemistry. This calls for nanoscale reference materials (nanoRMs) for the validation and standardization of commonly used characterization methods closely matching real-world nonspherical nano-objects. This encouraged us to develop a nonspherical nanoRM of very small size consisting of 8 nm iron oxide nanocubes (BAM-N012) to complement spherical gold, silica, and polymer nanoRMs. In the following, the development and production of this nanoRM are highlighted including the characterization by transmission electron microscopy (TEM) and small-angle X-ray scattering (SAXS) as complementary methods for size and shape parameters, homogeneity and stability studies, and calculation of a complete uncertainty budget of the size features. The determination of the nanocubes' edge length by TEM and SAXS allows a method comparison. In addition, SAXS measurements can also provide the mean particle number density and the mass concentration. The certified size parameters, area equivalent circular diameter and square edge length, determined by TEM with a relative expanded uncertainty below 9%, are metrologically traceable to a natural constant for length, the very precisely known (111) lattice spacing of silicon. Cubic BAM-N012 qualifies as a certified nanoRM for estimating the precision and trueness, validation, and quality assurance of particle size and shape measurements with electron microscopy and SAXS as well as other sizing methods suitable for nanomaterials. The production of this new iron oxide nanocube RM presents an important achievement for the nanomaterial community, nanomaterial manufacturers, and regulators.

2.
Small ; 19(8): e2205932, 2023 02.
Article in English | MEDLINE | ID: mdl-36507556

ABSTRACT

Protein adsorption at the air-water interface is a serious problem in cryogenic electron microscopy (cryoEM) as it restricts particle orientations in the vitrified ice-film and promotes protein denaturation. To address this issue, the preparation of a graphene-based modified support film for coverage of conventional holey carbon transmission electron microscopy (TEM) grids is presented. The chemical modification of graphene sheets enables the universal covalent anchoring of unmodified proteins via inherent surface-exposed lysine or cysteine residues in a one-step reaction. Langmuir-Blodgett (LB) trough approach is applied for deposition of functionalized graphene sheets onto commercially available holey carbon TEM grids. The application of the modified TEM grids in single particle analysis (SPA) shows high protein binding to the surface of the graphene-based support film. Suitability for high resolution structure determination is confirmed by SPA of apoferritin. Prevention of protein denaturation at the air-water interface and improvement of particle orientations is shown using human 20S proteasome, demonstrating the potential of the support film for structural biology.


Subject(s)
Graphite , Humans , Cryoelectron Microscopy , Graphite/chemistry , Microscopy, Electron , Proteins , Carbon/chemistry , Water/chemistry
3.
Small ; 19(15): e2206154, 2023 04.
Article in English | MEDLINE | ID: mdl-36651127

ABSTRACT

As virus outbreaks continue to pose a challenge, a nonspecific viral inhibitor can provide significant benefits, especially against respiratory viruses. Polyglycerol sulfates recently emerge as promising agents that mediate interactions between cells and viruses through electrostatics, leading to virus inhibition. Similarly, hydrophobic C60 fullerene can prevent virus infection via interactions with hydrophobic cavities of surface proteins. Here, two strategies are combined to inhibit infection of SARS-CoV-2 variants in vitro. Effective inhibitory concentrations in the millimolar range highlight the significance of bare fullerene's hydrophobic moiety and electrostatic interactions of polysulfates with surface proteins of SARS-CoV-2. Furthermore, microscale thermophoresis measurements support that fullerene linear polyglycerol sulfates interact with the SARS-CoV-2 virus via its spike protein, and highlight importance of electrostatic interactions within it. All-atom molecular dynamics simulations reveal that the fullerene binding site is situated close to the receptor binding domain, within 4 nm of polyglycerol sulfate binding sites, feasibly allowing both portions of the material to interact simultaneously.


Subject(s)
COVID-19 , Fullerenes , Humans , SARS-CoV-2 , Fullerenes/pharmacology , Protein Binding
4.
Anal Bioanal Chem ; 415(3): 371-377, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36447098

ABSTRACT

Gold films coated with a graphene sheet are being widely used as sensors for the detection of label-free binding interactions using surface plasmon resonance (SPR). During the preparation of such sensors, it is often essential to subject the sensor chips to a high-temperature treatment in order to ensure a clean graphene surface. However, sensor chips used currently, which often use chromium as an adhesion promoter, cannot be subjected to temperatures above 250 °C, because under such conditions, chromium is found to reorganize and diffuse to the surface, where it is easily oxidized, impairing the quality of SPR spectra. Here we present an optimized preparation strategy involving a three-cycle tempering coupled with chromium (oxide) etching, which allows the graphene-coated SPR chips to be annealed up to 500 °C with little deterioration of the surface morphology. In addition, the treatment delivers a surface that shows a clear enhancement in spectral response together with a good refractive index sensitivity. We demonstrate the applicability of our sensors by studying the kinetics of avidin-biotin binding at different pH repeatedly on the same chip. The possibility to anneal can be exploited to recover the original surface after sensing trials, which allowed us to reuse the sensor for at least six cycles of biomolecule adsorption.


Subject(s)
Graphite , Surface Plasmon Resonance , Graphite/chemistry , Temperature , Gold/chemistry , Adsorption
5.
Anal Bioanal Chem ; 414(15): 4331-4345, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35471249

ABSTRACT

Core-shell nanoparticles have attracted much attention in recent years due to their unique properties and their increasing importance in many technological and consumer products. However, the chemistry of nanoparticles is still rarely investigated in comparison to their size and morphology. In this review, the possibilities, limits, and challenges of X-ray photoelectron spectroscopy (XPS) for obtaining more insights into the composition, thickness, and homogeneity of nanoparticle coatings are discussed with four examples: CdSe/CdS quantum dots with a thick coating and a small core; NaYF4-based upconverting nanoparticles with a large Yb-doped core and a thin Er-doped coating; and two types of polymer nanoparticles with a poly(tetrafluoroethylene) core with either a poly(methyl methacrylate) or polystyrene coating. Different approaches for calculating the thickness of the coating are presented, like a simple numerical modelling or a more complex simulation of the photoelectron peaks. Additionally, modelling of the XPS background for the investigation of coating is discussed. Furthermore, the new possibilities to measure with varying excitation energies or with hard-energy X-ray sources (hard-energy X-ray photoelectron spectroscopy) are described. A discussion about the sources of uncertainty for the determination of the thickness of the coating completes this review. Graphical abstract.


Subject(s)
Nanoparticles , Quantum Dots , Nanoparticles/chemistry , Photoelectron Spectroscopy , Polymers , Polystyrenes
6.
Molecules ; 27(3)2022 Feb 01.
Article in English | MEDLINE | ID: mdl-35164246

ABSTRACT

Whereas the characterization of nanomaterials using different analytical techniques is often highly automated and standardized, the sample preparation that precedes it causes a bottleneck in nanomaterial analysis as it is performed manually. Usually, this pretreatment depends on the skills and experience of the analysts. Furthermore, adequate reporting of the sample preparation is often missing. In this overview, some solutions for techniques widely used in nano-analytics to overcome this problem are discussed. Two examples of sample preparation optimization by automation are presented, which demonstrate that this approach is leading to increased analytical confidence. Our first example is motivated by the need to exclude human bias and focuses on the development of automation in sample introduction. To this end, a robotic system has been developed, which can prepare stable and homogeneous nanomaterial suspensions amenable to a variety of well-established analytical methods, such as dynamic light scattering (DLS), small-angle X-ray scattering (SAXS), field-flow fractionation (FFF) or single-particle inductively coupled mass spectrometry (sp-ICP-MS). Our second example addresses biological samples, such as cells exposed to nanomaterials, which are still challenging for reliable analysis. An air-liquid interface has been developed for the exposure of biological samples to nanomaterial-containing aerosols. The system exposes transmission electron microscopy (TEM) grids under reproducible conditions, whilst also allowing characterization of aerosol composition with mass spectrometry. Such an approach enables correlative measurements combining biological with physicochemical analysis. These case studies demonstrate that standardization and automation of sample preparation setups, combined with appropriate measurement processes and data reduction are crucial steps towards more reliable and reproducible data.

8.
Adv Funct Mater ; 31(22): 2009003, 2021 May 26.
Article in English | MEDLINE | ID: mdl-34230823

ABSTRACT

2D nanomaterials have garnered widespread attention in biomedicine and bioengineering due to their unique physicochemical properties. However, poor functionality, low solubility, intrinsic toxicity, and nonspecific interactions at biointerfaces have hampered their application in vivo. Here, biocompatible polyglycerol units are crosslinked in two dimensions using a graphene-assisted strategy leading to highly functional and water-soluble polyglycerols nanosheets with 263 ± 53 nm and 2.7 ± 0.2 nm average lateral size and thickness, respectively. A single-layer hyperbranched polyglycerol containing azide functional groups is covalently conjugated to the surface of a functional graphene template through pH-sensitive linkers. Then, lateral crosslinking of polyglycerol units is carried out by loading tripropargylamine on the surface of graphene followed by lifting off this reagent for an on-face click reaction. Subsequently, the polyglycerol nanosheets are detached from the surface of graphene by slight acidification and centrifugation and is sulfated to mimic heparin sulfate proteoglycans. To highlight the impact of the two-dimensionality of the synthesized polyglycerol sulfate nanosheets at nanobiointerfaces, their efficiency with respect to herpes simplex virus type 1 and severe acute respiratory syndrome corona virus 2 inhibition is compared to their 3D nanogel analogs. Four times stronger in virus inhibition suggests that 2D polyglycerols are superior to their current 3D counterparts.

9.
Small ; 17(11): e2007091, 2021 03.
Article in English | MEDLINE | ID: mdl-33533178

ABSTRACT

Search of new strategies for the inhibition of respiratory viruses is one of the urgent health challenges worldwide, as most of the current therapeutic agents and treatments are inefficient. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused a pandemic and has taken lives of approximately two million people to date. Even though various vaccines are currently under development, virus, and especially its spike glycoprotein can mutate, which highlights a need for a broad-spectrum inhibitor. In this work, inhibition of SARS-CoV-2 by graphene platforms with precise dual sulfate/alkyl functionalities is investigated. A series of graphene derivatives with different lengths of aliphatic chains is synthesized and is investigated for their ability to inhibit SARS-CoV-2 and feline coronavirus. Graphene derivatives with long alkyl chains (>C9) inhibit coronavirus replication by virtue of disrupting viral envelope. The ability of these graphene platforms to rupture viruses is visualized by atomic force microscopy and cryogenic electron microscopy. A large concentration window (10 to 100-fold) where graphene platforms display strongly antiviral activity against native SARS-CoV-2 without significant toxicity against human cells is found. In this concentration range, the synthesized graphene platforms inhibit the infection of enveloped viruses efficiently, opening new therapeutic and metaphylactic avenues against SARS-CoV-2.


Subject(s)
Graphite/chemistry , SARS-CoV-2/chemistry , Antiviral Agents/pharmacology , COVID-19/epidemiology , COVID-19/virology , Cryoelectron Microscopy , Humans , Microscopy, Atomic Force , Pandemics , SARS-CoV-2/drug effects
10.
Langmuir ; 37(29): 8876-8885, 2021 Jul 27.
Article in English | MEDLINE | ID: mdl-34255529

ABSTRACT

Surface self-assembly of spherical nanoparticles of sizes below 10 nm into hierarchical heterostructures is under arising development despite the inherent difficulties of obtaining complex ordering patterns on a larger scale. Due to template-mediated interactions between oil-dispersible superparamagnetic nanoparticles (MNPs) and polyethylenimine-stabilized gold nanoparticles (Au(PEI)NPs) at the water-oil interface of microemulsions, complex nanostructured films can be formed. Characterization of the reverse microemulsion phase by UV-vis absorption revealed the formation of heteroclusters from Winsor type II phases (WPII) using Aerosol-OT (AOT) as the surfactant. SAXS measurements verify the mechanism of initial nanoparticle clustering in defined dimensions. XPS suggested an influence of AOT at the MNP surface. Further, cryo-SEM and TEM visualization demonstrated the elongation of the reverse microemulsions into cylindrical, wormlike structures, which subsequently build up larger nanoparticle superstructure arrangements. Such WPII phases are thus proven to be a new form of soft template, mediating the self-assembly of different nanoparticles in hierarchical network-like filaments over a substrate during solvent evaporation.

11.
Soft Matter ; 17(29): 6985-6994, 2021 Jul 28.
Article in English | MEDLINE | ID: mdl-34236377

ABSTRACT

The composition of the surface layer in dependence from the distance of the polymer/air interface in thin films with thicknesses below 100 nm of miscible polymer blends in a spatial region of a few nanometers is not investigated completely. Here, thin films of the blend poly(vinyl methyl ether) (PVME)/polystyrene (PS) with a composition of 25/75 wt% are investigated by Energy Resolved X-ray Photoelectron Spectroscopy (ER-XPS) at a synchrotron storage ring using excitation energies lower than 1 keV. By changing the energy of the photons the information depth is varied in the range from ca. 1 nm to 10 nm. Therefore, the PVME concentration could be estimated in dependence from the distance of the polymer/air interface for film thicknesses below 100 nm. Firstly, as expected for increasing information depth the PVME concentration decreases. Secondly, it was found that the PVME concentration at the surface has a complicated dependence on the film thickness. It increases with decreasing film thickness until 30 nm where a maximum is reached. For smaller film thicknesses the PVME concentration decreases. A simplified layer model is used to calculate the effective PVME concentration in the different spatial regions of the surface layer.

12.
Molecules ; 26(17)2021 09 01.
Article in English | MEDLINE | ID: mdl-34500752

ABSTRACT

ACEnano is an EU-funded project which aims at developing, optimising and validating methods for the detection and characterisation of nanomaterials (NMs) in increasingly complex matrices to improve confidence in the results and support their use in regulation. Within this project, several interlaboratory comparisons (ILCs) for the determination of particle size and concentration have been organised to benchmark existing analytical methods. In this paper the results of a number of these ILCs for the characterisation of NMs are presented and discussed. The results of the analyses of pristine well-defined particles such as 60 nm Au NMs in a simple aqueous suspension showed that laboratories are well capable of determining the sizes of these particles. The analysis of particles in complex matrices or formulations such as consumer products resulted in larger variations in particle sizes within technologies and clear differences in capability between techniques. Sunscreen lotion sample analysis by laboratories using spICP-MS and TEM/SEM identified and confirmed the TiO2 particles as being nanoscale and compliant with the EU definition of an NM for regulatory purposes. In a toothpaste sample orthogonal results by PTA, spICP-MS and TEM/SEM agreed and stated the TiO2 particles as not fitting the EU definition of an NM. In general, from the results of these ILCs we conclude that laboratories are well capable of determining particle sizes of NM, even in fairly complex formulations.

13.
J Vac Sci Technol A ; 38(6): 063208, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33281279

ABSTRACT

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ∼3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ∼5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ∼4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. We also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

14.
Angew Chem Int Ed Engl ; 56(37): 11242-11247, 2017 09 04.
Article in English | MEDLINE | ID: mdl-28517035

ABSTRACT

Hydrodehalogenation is a straightforward approach for detoxifications of harmful anthropogenic organohalide-based pollutants, as well as removal of halide protecting groups used in multistep syntheses. A novel sustainable catalytic material was prepared from biowaste (chitosan) in combination with an earth-abundant cobalt salt. The heterogeneous catalyst was fully characterized by transmission electron microscope, X-ray diffraction, and X-ray photoelectron spectroscopy measurements, and successfully applied to hydrodehalogenation of alkyl and (hetero)aryl halides with broad scope (>40 examples) and excellent chemoselectivity using molecular hydrogen as a reductant. The general usefulness of this method is demonstrated by successful detoxification of non-degradable pesticides and fire retardants. Moreover, the potential of the catalyst as a deprotection tool is demonstrated in a multistep synthesis of (±)-peronatin B (alkaloid).

15.
J Am Chem Soc ; 138(28): 8781-8, 2016 07 20.
Article in English | MEDLINE | ID: mdl-27320777

ABSTRACT

Novel heterogeneous cobalt-based catalysts have been prepared by pyrolysis of cobalt complexes with nitrogen ligands on different inorganic supports. The activity and selectivity of the resulting materials in the hydrogenation of nitriles and carbonyl compounds is strongly influenced by the modification of the support and the nitrogen-containing ligand. The optimal catalyst system ([Co(OAc)2/Phen@α-Al2O3]-800 = Cat. E) allows for efficient reduction of both aromatic and aliphatic nitriles including industrially relevant dinitriles to primary amines under mild conditions. The generality and practicability of this system is further demonstrated in the hydrogenation of diverse aliphatic, aromatic, and heterocyclic ketones as well as aldehydes, which are readily reduced to the corresponding alcohols.

16.
J Am Chem Soc ; 137(36): 11718-24, 2015 Sep 16.
Article in English | MEDLINE | ID: mdl-26293483

ABSTRACT

Cobalt oxide/cobalt-based nanoparticles featuring a core-shell structure and nitrogen-doped graphene layers on alumina are obtained by pyrolysis of Co(OAc)2/phenanthroline. The resulting core-shell material (Co3O4-Co/NGr@α-Al2O3) was successfully applied in the catalytic hydrogenation of a variety of N-heteroarenes including quinolines, acridines, benzo[h], and 1,5-naphthyridine as well as unprotected indoles. The peculiar structure of the novel heterogeneous catalyst enables activation of molecular hydrogen at comparably low temperature. Both high activity and selectivity were achieved in these hydrogenation processes, to give important building blocks for bioactive compounds as well as the pharmaceutical industry.

17.
Chemistry ; 21(43): 15280-9, 2015 Oct 19.
Article in English | MEDLINE | ID: mdl-26471442

ABSTRACT

Co-components are a powerful tool to tune the performance of catalysts, but their nature and their impact on the catalysts is often controversially discussed. In this study X-ray absorption spectroscopy (XAS) was employed to elucidate the nature of co-components and their impact on the catalytic reaction. In anatase-supported Pd-based catalysts for the gas-phase acetoxylation of toluene, less noble co-components (e.g., Mn, Co, and Sb) spread over the support in their oxidic form and changed their valence state on stream. Incorporated atoms such as C or a small part of the Sb affect the electronic structure of Pd. For the noble Au, only a weak interaction with the support and Pd was observed during time on stream. Only XAS at the K-edges together with investigations of the Pd L-edge for a better understanding of the electronic structure, supplemented by STEM for elemental mapping, allow such detailed insights.

18.
J Nanosci Nanotechnol ; 15(9): 7275-9, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26716323

ABSTRACT

The synthesis of nano silver coated ZSM-5 zeolite (Ag/ZSM-5) by ion exchange method combined with anaerobic thermal treatment and its bacterial elimination performance were studied. The various Ag content of different samples was analysed by atomic absorption spectroscopy method. The Ag/ZSM-5 sample with 0.251 wt% Ag (denoted as ZAg3) was characterized by using atomic absorption spectroscopy, transmission electron microscopy, X-ray photoelectron spectroscopy and pulsed CO chemisorption methods. The results showed that silver nanoparticles with a small nano-size of 2-3 nm were formed and distributed on the surface of ZSM-5 zeolite with a dispersion value of 59%. The samples denoted as ZAg1, ZAg2, ZAg3, ZAg4 correspond to a Ag content of 0.064; 0.128; 0.251; 0.253 wt% Ag. In the evaluation series, after 10 min of contact time between bacterial and Ag/ZSM-5, over 99% of E.coli (initial concentration was 10(6) cfu/ml) could be eliminated by Ag/ZSM-5 with the Ag content of at least 0.251 wt% (ZAg3). In addition, over 99% of Coliform (initial concentration was 10(5) cfu/ml) could be eliminated by Ag/ZSM-5 with Ag content of at least 0.128 wt% (ZAg2). In a further evaluation series varying the contact time, ZAg3 sample could eliminate over 99% and 100% of Ecoli after 10 min and 60 min, respectively (initial concentrations of both E.coli and Coliform were 10(5) cfu/ml). In addition, it could eliminate 100% of Coliform in only 10 min of contact time.


Subject(s)
Anti-Bacterial Agents/chemistry , Anti-Bacterial Agents/chemical synthesis , Metal Nanoparticles/chemistry , Silver/chemistry , Zeolites/chemistry , Anti-Bacterial Agents/pharmacology , Escherichia coli/drug effects , Silver/pharmacology
19.
Phys Chem Chem Phys ; 16(10): 4789-96, 2014 Mar 14.
Article in English | MEDLINE | ID: mdl-24469267

ABSTRACT

The photoreduction of the bis(2-phenylpyridinato-)(2,2'-bipyridine)iridium(III) ion ([Ir(ppy)2(bpy)](+)), used as a photosensitizer in photocatalytic water splitting, by triethylamine was studied by means of UV/VIS, XANES, and EPR spectroscopies, supported by theoretical calculations at density functional theory (DFT) and complete active space self-consistent field (CASSCF/CASPT2) levels. The combination of these methods suggests a predominant bpy localization of the spin-density of the unpaired electron with notable delocalization to the Ir center. This is particularly evident from EPR and theoretical results and leads to broad EPR lines and a large anisotropy of the g-factor.

20.
Angew Chem Int Ed Engl ; 53(17): 4359-63, 2014 Apr 22.
Article in English | MEDLINE | ID: mdl-24644140

ABSTRACT

A general epoxidation of aromatic and aliphatic olefins has been developed under mild conditions using heterogeneous Cox Oy -N/C (x=1,3; y=1,4) catalysts and tert-butyl hydroperoxide as the terminal oxidant. Various stilbenes and aliphatic alkenes, including renewable olefins, and vitamin and cholesterol derivatives, were successfully transformed into the corresponding epoxides with high selectivity and often good yields. The cobalt oxide catalyst can be recycled up to five times without significant loss of activity or change in structure. Characterization of the catalyst by XRD, TEM, XPS, and EPR analysis revealed the formation of cobalt oxide nanoparticles with varying size (Co3 O4 with some CoO) and very few large particles with a metallic Co core and an oxidic shell. During the pyrolysis process the nitrogen ligand forms graphene-type layers, in which selected carbon atoms are substituted by nitrogen.

SELECTION OF CITATIONS
SEARCH DETAIL