Europace ; 20(FI_3): f321-f328, 2018 11 01.
Article in English | MEDLINE | ID: mdl-29036652

ABSTRACT

Aims: Intermittent change in p-wave discernibility during periods of ectopy and sinus arrhythmia is a cause of inappropriate atrial fibrillation (AF) detection in insertable cardiac monitors (ICM). To address this, we developed and validated an enhanced AF detection algorithm. Methods and results: Atrial fibrillation detection in Reveal LINQ ICM uses patterns of incoherence in RR intervals and absence of P-wave evidence over a 2-min period. The enhanced algorithm includes P-wave evidence during RR irregularity as evidence of sinus arrhythmia or ectopy to adaptively optimize sensitivity for AF detection. The algorithm was developed and validated using Holter data from the XPECT and LINQ Usability studies which collected surface electrocardiogram (ECG) and continuous ICM ECG over a 24-48 h period. The algorithm detections were compared with Holter annotations, performed by multiple reviewers, to compute episode and duration detection performance. The validation dataset comprised of 3187 h of valid Holter and LINQ recordings from 138 patients, with true AF in 37 patients yielding 108 true AF episodes ≥2-min and 449 h of AF. The enhanced algorithm reduced inappropriately detected episodes by 49% and duration by 66% with <1% loss in true episodes or duration. The algorithm correctly identified 98.9% of total AF duration and 99.8% of total sinus or non-AF rhythm duration. The algorithm detected 97.2% (99.7% per-patient average) of all AF episodes ≥2-min, and 84.9% (95.3% per-patient average) of detected episodes involved AF. Conclusion: An enhancement that adapts sensitivity for AF detection reduced inappropriately detected episodes and duration with minimal reduction in sensitivity.


Subject(s)
Algorithms , Arrhythmia, Sinus/diagnosis , Atrial Fibrillation/diagnosis , Electrocardiography, Ambulatory/methods , Heart Rate , Signal Processing, Computer-Assisted , Telemedicine/methods , Telemetry/methods , Aged , Arrhythmia, Sinus/physiopathology , Atrial Fibrillation/physiopathology , Diagnostic Equipment , Electrocardiography, Ambulatory/instrumentation , Equipment Design , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Reproducibility of Results , Telemedicine/instrumentation , Telemetry/instrumentation , Time Factors
2.
Heart Rhythm ; 14(7): 1016-1023, 2017 07.
Article in English | MEDLINE | ID: mdl-28373132

ABSTRACT

BACKGROUND: Undersensing of premature ventricular beats and low-amplitude R waves are primary causes for inappropriate bradycardia and pause detections in insertable cardiac monitors (ICMs). OBJECTIVE: The purpose of this study was to develop and validate an enhanced algorithm to reduce inappropriately detected bradycardia and pause episodes. METHODS: Independent data sets to develop and validate the enhanced algorithm were derived from a database of ICM-detected bradycardia and pause episodes in de-identified patients monitored for unexplained syncope. The original algorithm uses an auto-adjusting sensitivity threshold for R-wave sensing to detect tachycardia and avoid T-wave oversensing. In the enhanced algorithm, a second sensing threshold is used with a long blanking and fixed lower sensitivity threshold, looking for evidence of undersensed signals. Data reported includes percent change in appropriate and inappropriate bradycardia and pause detections as well as changes in episode detection sensitivity and positive predictive value with the enhanced algorithm. RESULTS: The validation data set, from 663 consecutive patients, consisted of 4904 (161 patients) bradycardia and 2582 (133 patients) pause episodes, of which 2976 (61%) and 996 (39%) were appropriately detected bradycardia and pause episodes. The enhanced algorithm reduced inappropriate bradycardia and pause episodes by 95% and 47%, respectively, with 1.7% and 0.6% reduction in appropriate episodes, respectively. The average episode positive predictive value improved by 62% (P < .001) for bradycardia detection and by 26% (P < .001) for pause detection, with an average relative sensitivity of 95% (P < .001) and 99% (P = .5), respectively. CONCLUSION: The enhanced dual sense algorithm for bradycardia and pause detection in ICMs substantially reduced inappropriate episode detection with a minimal reduction in true episode detection.


Subject(s)
Bradycardia/diagnosis , Electrocardiography, Ambulatory , Electrodes, Implanted , Syncope , Aged , Algorithms , Bradycardia/complications , Diagnostic Errors/prevention & control , Dimensional Measurement Accuracy , Electrocardiography, Ambulatory/adverse effects , Electrocardiography, Ambulatory/instrumentation , Electrocardiography, Ambulatory/methods , Electrodes, Implanted/adverse effects , Equipment Design , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Syncope/diagnosis , Syncope/etiology , United States