Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 36
Filter
1.
Skin Pharmacol Physiol ; 26(4-6): 227-33, 2013.
Article in English | MEDLINE | ID: mdl-23921109

ABSTRACT

The efficacy of topically applied drugs is determined by their action mechanism and their potential capacity of passing the skin barrier. Nanoparticles are assumed to be efficient carrier systems for drug delivery through the skin barrier. For flexible nanoparticles like liposomes, this effect has been well demonstrated. The penetration properties of solid nanoparticles are currently under intensive investigation. The crucial advantage of nanoparticles over non-particulate substances is their capability to penetrate deeply into the hair follicles where they can be stored for several days. There is no evidence, yet, that solid particles ≥40 nm are capable of passing through the healthy skin barrier. Therefore and in spite of the long-standing research efforts in this field, commercially available solid nanoparticle-based products for drug delivery through the healthy skin are still missing. Nevertheless, the prospects for the clinical use of nanoparticles in drug delivery are tremendous. They can be designed as transport systems delivering drugs efficiently into the hair follicles in the vicinity of specific target structures. Once deposited at these structures, specific signals might trigger the release of the drugs and exert their effects on the target cells. In this article, examples of such triggered drug release are presented.


Subject(s)
Drug Delivery Systems , Nanoparticles , Skin Absorption , Administration, Cutaneous , Animals , Biological Transport , Drug Design , Hair Follicle/metabolism , Humans , Liposomes , Particle Size , Skin/metabolism
2.
Zhonghua Xin Xue Guan Bing Za Zhi ; 38(6): 514-7, 2010 Jun.
Article in Zh | MEDLINE | ID: mdl-21033132

ABSTRACT

OBJECTIVE: To evaluate the value of human fatty acid binding protein (h-FABP) in predicting myocardial ischemia and injury in the perioperative period of cardiac surgery, we observed the dynamic changes of h-FABP in perioperative period of patients underwent coronary artery bypass grafting and ventricular septal defects repairing surgery, and evaluated the relationship of h-FABP and ischemia modified albumin (IMA), CK-MB, cTnI. METHODS: Patients underwent coronary artery bypass grafting (n=30) and ventricular septal defect repairing (n=30) surgery between February 2008 and December 2008 were included in this study. Venous blood sample was obtained at preoperative, aortic clamping, aortic unclamping of 10 min, 2 h, 6 h, 12 h, 24 h for the measurements of h-FABP, IMA, cTnI and CK-MB. RESULTS: h-FABP and IMA changed in the same way at various examined time points, h-FABP changes also paralleled cTnI and CK-MB changes, h-FABP peaked early during myocardial ischemia and injury and returned to baseline level at 2 h post myocardial ischemia and injury. Linear correlation analysis showed that the peak value of h-FABP was positively correlated with IMA, CK-MB and cTnI in both CABG group (r = 0.948, 0.964 and 0.961, P < 0.05) and in the VSD group (r = 0.986, 0.978 and 0.957). CONCLUSIONS: h-FABP is an early diagnostic parameter reflecting perioperative myocardial ischemia and injury in cardiac surgery. Quantitative h-FABP monitoring could predict the severity of myocardial ischemia and injury early during cardiac surgery.


Subject(s)
Fatty Acid-Binding Proteins/blood , Myocardial Ischemia/diagnosis , Myocardium/metabolism , Aged , Albumins/analysis , Biomarkers/blood , Creatine Kinase, MB Form/blood , Humans , Middle Aged , Myocardial Ischemia/surgery , Perioperative Period , Predictive Value of Tests , Thoracic Surgery , Troponin I/blood
3.
Skin Pharmacol Physiol ; 22(1): 31-44, 2009.
Article in English | MEDLINE | ID: mdl-19122479

ABSTRACT

The recent European recommendation on the efficacy of sunscreen products requests now a minimum ratio of UVA/UVB protection. However, the visible and the infrared (IR) parts of the sun spectrum have received little attention concerning their possible contribution to skin damage. A common biophysical answer for the different wavelengths of the sun spectrum can be found in the creation of excess free radicals - mainly reactive oxygen species (ROS). Thanks to electron spin resonance spectroscopy applied to skin biopsies, we determined for the first time the free radical action spectrum covering UV and visible light (280-700 nm). Convolution of the action spectrum with sunlight spectral irradiance showed that 50% of the total skin oxidative burden was generated by visible light. Creation of ROS by visible light was experimentally confirmed by varying the illuminance of a spotlight. We also evidenced the creation of excess free radicals by near-IR radiation. In that case, free radical generation does not depend exclusively on the dose, but also on the skin temperature increase initiated by near-IR light. Some phenomena which are still unclear, such as the question about the deleterious or beneficial role of sunlight, are reviewed, implying the research on new protection strategies for the prevention of skin cancer.


Subject(s)
Free Radicals/metabolism , Light , Oxidative Stress/radiation effects , Skin/radiation effects , Biopsy , Dose-Response Relationship, Radiation , Electron Spin Resonance Spectroscopy , Humans , In Vitro Techniques , Skin/metabolism , Skin Temperature , Ultraviolet Rays
4.
Acta Biomater ; 30: 388-396, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26621698

ABSTRACT

Recent advances in the field of dermatotherapy have resulted in research efforts focusing on the use of particle-based drug delivery systems for the stimuli-responsive release of drugs in the skin and skin appendages, i.e. hair follicles and sebaceous glands. However, effective and innocuous trigger mechanisms which result in the release of the drugs from the nanocarriers upon reaching the target structures are still lacking. For the first time, the present study demonstrated the photo-activated release of the model drug fluorescein isothiocyanate (FITC) from topically applied gold nanoparticle-doped bovine serum albumin (AuNPs-doped BSA) particles (approx. 545nm) using water-filtered infrared A (IRA) radiation in the hair follicles of an ex vivo porcine skin model. The IRA radiation-induced plasmonic heating of the AuNPs results in the partial decomposition or opening of the albumin particles and release the model drug, while control particles without AuNPs show insignificant release. The results demonstrate the feasibility of using IRA radiation to induce release of encapsulated drugs from plasmonic nanocarriers for the targeting of follicular structures. However, the risk of radiation-induced skin damage subsequent to repeated applications of high infrared dosages may be significant. Future studies should aim at determining the suitability of lower infrared A dosages, such as for medical treatment regimens which may necessitate repeated exposure to therapeutics. STATEMENT OF SIGNIFICANCE: Follicular targeting using nanocarriers is of increasing importance in the prophylaxis and treatment of dermatological or other diseases. For the first time, the present study demonstrated the photo-activated release of the model drug fluorescein isothiocyanate (FITC) from topically applied gold nanoparticle-doped bovine serum albumin (AuNPs-doped BSA) particles using water-filtered infrared A (IRA) radiation in the hair follicles of an ex vivo porcine skin model. The results demonstrate the feasibility of using wIRA radiation to induce release of encapsulated drugs for the targeting of follicular structures, and provide a new vision on the development of optically addressable delivery systems for controlled release of drugs in the skin and skin appendages, i.e. hair follicles and sebaceous glands.


Subject(s)
Drug Carriers , Gold , Hair Follicle/metabolism , Infrared Rays , Metal Nanoparticles/chemistry , Serum Albumin, Bovine , Administration, Topical , Animals , Cattle , Drug Carriers/chemistry , Drug Carriers/pharmacokinetics , Drug Carriers/pharmacology , Fluorescein-5-isothiocyanate/chemistry , Fluorescein-5-isothiocyanate/pharmacokinetics , Fluorescein-5-isothiocyanate/pharmacology , Gold/chemistry , Gold/pharmacokinetics , Gold/pharmacology , Hair Follicle/pathology , Serum Albumin, Bovine/chemistry , Serum Albumin, Bovine/pharmacokinetics , Serum Albumin, Bovine/pharmacology , Swine
5.
J Immunol Methods ; 215(1-2): 17-26, 1998 Jun 01.
Article in English | MEDLINE | ID: mdl-9744744

ABSTRACT

Application of a grating coupler sensor (GCS) to the real time investigation of the interaction kinetics of covalently immobilized recombinant bovine heart-type fatty acid-binding protein (H-FABP) and corresponding antibody is described. The immobilization of the antigen is performed by activating the matrix hydroxyl groups with p-toluenesulfonyl chloride (TSC) and afterwards coupling the protein by reaction with its nucleophilic aminogroups. Covalent coupling via TSC permits reproducible measurements of immunointeractions on the same grating coupler sensor chip and complete regeneration after each binding cycle with glycine-hydrochloride. We demonstrate the analysis of binding data obtained on a GCS by linearization as well as direct curve fitting using the integrated rate equation for the determination of apparent rate and affinity constants. With both analysis methods we studied H-FABP/monoclonal anti-H-FABP-antibody interactions and obtained an average apparent association rate constant ka = 4.2 X 10(3) M(-1) s(-1) a dissociation rate constant of kd=1.3 X 10(-4) s(-1) and an equilibrium constant of KD=3 X 10(-8) M.


Subject(s)
Antibodies, Monoclonal/metabolism , Antigen-Antibody Reactions , Biosensing Techniques , Carrier Proteins/metabolism , Myelin P2 Protein/metabolism , Neoplasm Proteins , Animals , Antibodies, Monoclonal/immunology , Carrier Proteins/immunology , Cattle , Fatty Acid-Binding Proteins , Kinetics , Myelin P2 Protein/immunology
6.
J Immunol Methods ; 217(1-2): 103-11, 1998 Aug 01.
Article in English | MEDLINE | ID: mdl-9776580

ABSTRACT

In standard displacement flow immunoassays the analyte in the sample creates an active dissociation of labelled antigens (or antigen homologues) from an antigen binding site of an immobilized antibody, after which the labelled substance is measured downstream. Such systems have been described for molecules up to 1 kDa. In this study, we demonstrate displacement in a flow system for the detection of a small protein, cytoplasmic heart-type fatty acid-binding protein (15 kDa), a plasma marker for myocardial injury. The displacement system uses an inverse set-up: enzyme labelled monoclonal antibodies are associated to immobilized antigen, and are displaced by analyte in the sample. The system permits detection of both physiological (2-12 microg l(-1)) and pathological concentrations (12-2000 microg l(-1)) of fatty acid-binding protein in an on-line flow system.


Subject(s)
Carrier Proteins/analysis , Immunoassay/methods , Myelin P2 Protein/analysis , Neoplasm Proteins , Nerve Tissue Proteins , Animals , Biomarkers , Enzyme-Linked Immunosorbent Assay , Fatty Acid-Binding Protein 7 , Fatty Acid-Binding Proteins , Immunosorbent Techniques , Molecular Weight , Myocardial Infarction/blood , Myocardial Infarction/diagnosis , Myocardium/chemistry , Rats , Recombinant Proteins/analysis , Rheology , Species Specificity
7.
Biosens Bioelectron ; 19(8): 805-12, 2004 Mar 15.
Article in English | MEDLINE | ID: mdl-15128099

ABSTRACT

A bench scale reactor using a sequencing batch reactor process was used to evaluate the applicability of biosensors for the process optimization of biological carbon and nitrogen removal. A commercial biochemical oxygen demand (BOD) biosensor with a novel microbial membrane was used to determine the duration of each phase by measuring samples in real time in an SBR cycle with filling/anoxic-anaerobic/aerobic/sludge wasting/settling/withdrawal periods. Possible strategies to increase the efficiency for the biological removal of carbon and nitrogen from synthetic wastewater have been developed. The results show that application of a BOD biosensor enables estimation of organic carbon, in real time, allowing the optimization or reduction the SBR cycle time. Some typical consumption patterns for organic carbon in the non-aeration phase of a typical SBR operation were identified. The rate of decrease of BOD measured using a sensor BOD, was the highest in the initial glucose breakdown period and during denitrification. It then slowed down until a 'quiescent period' was observed, which may be considered as the commencement of the aeration period. Monitoring the BOD curve with a BOD biosensor allowed the reduction of the SBR cycle time, which leads to an increase in the removal efficiency. By reducing the cycle time from 8 to 4 h cycle, the removal efficiencies of nitrate, glucose, and phosphorus in a given time interval, were increased to nearly double, while the removal of nitrogen ammonium was increased by one-third.


Subject(s)
Bioreactors/microbiology , Biosensing Techniques/instrumentation , Carbon/metabolism , Nitrogen/metabolism , Oxygen Consumption/physiology , Oxygen/analysis , Water Purification/methods , Bacteria, Aerobic/metabolism , Biosensing Techniques/methods , Cell Culture Techniques/instrumentation , Cell Culture Techniques/methods , Feedback/physiology , Industrial Waste/prevention & control , Oxygen/metabolism , Quality Control , Reproducibility of Results , Sensitivity and Specificity , Waste Disposal, Fluid/methods , Water Pollutants, Chemical/metabolism
8.
Biosens Bioelectron ; 10(6-7): 577-86, 1995.
Article in English | MEDLINE | ID: mdl-7612209

ABSTRACT

Apolipoprotein (apo) E is a constituent of serum lipoproteins and can serve as a diagnostic parameter for the assessment of disorders of lipid metabolism. For the determination of apo E in serum a sandwich-type amperometric immunosensor using disposable membranes was developed. The best results were obtained by using a site-directed attachment of a monoclonal capture antibody to a hydrazide-functionalized membrane surface. Bound antigen was then determined with the aid of a polyclonal antibody labelled with alkaline phosphatase in conjunction with p-aminophenyl phosphate as substrate. In this approach a carbon working electrode (vs. Hg/HgCl2) was used, and enzymatically generated p-aminophenol could be monitored with a detection limit of 40 pmol and a linear range of 26-20000 nM. The sensor displayed a linear response from 50 to 1000 ng ml-1 apo E. In contrast, antibody coupling through primary amino groups led to a total loss of antigen binding capacity in this assay configuration. The approach with site-directed immobilization however, not only allowed the determination of apo E in serum, but also the determination of antibody cross-reactivity against the apolipoproteins AI, AII and B.


Subject(s)
Apolipoproteins E/blood , Biosensing Techniques , Aminophenols/analysis , Cross Reactions , Electrochemistry , Humans , Reproducibility of Results
9.
Biosens Bioelectron ; 12(1): 43-52, 1997.
Article in English | MEDLINE | ID: mdl-8976051

ABSTRACT

Redox mediators enable an efficient electron transfer between redox enzymes and the electrochemical surface of amperometric sensors. A stable and highly sensitive signal was obtained using a tetrathiafulvalene (TTF)-modified graphite electrode. In the presence of horseradish peroxidase (HRP), hydrogen peroxide (H2O2) was monitored with a detection limit of 7 nM at a potential of +20 mV versus a saturated calomel electrode (SCE). With a constant concentration of H2O2, the detection limit for HRP was found to be 150 pM. The accuracy of consecutive measurement of HRP in flow-through systems was improved by short-time polarizing the TTF-modified graphite electrode at +100 mV versus Ag/AgCl/3 M KCl. Using the TTF-modified graphite electrode in an immuno-sandwich approach, rabbit-immunoglobulin G was monitored in the range 5-100 ng/ml.


Subject(s)
Biosensing Techniques , Horseradish Peroxidase/analysis , Hydrogen Peroxide/analysis , Animals , Hydrogen-Ion Concentration , Rabbits , Temperature
10.
Biosens Bioelectron ; 13(10): 1141-7, 1998 Nov 01.
Article in English | MEDLINE | ID: mdl-9842709

ABSTRACT

In the present paper surface studies for the development of a direct optical immunosensor for fast diagnosis of a myocardial infarction are presented. A fatty acid binding protein was detected by monoclonal antibodies. The applied measuring system was the grating coupler BIOS-1. Based on commercially available transducer materials protein immobilisation techniques have been developed and characterised by TOF-SIMS, AFM and EM. Three different label-free assay types were investigated. Only one assay leads to a sensitive and regenerable sensor set-up. It was possible to detect concentrations of the fatty acid binding protein down to 330 ng/ml. The general applicability of a direct optical immunosensor in the field of myocardial infarction diagnosis was demonstrated by this.


Subject(s)
Immunoassay/methods , Myocardial Infarction/diagnosis , Neoplasm Proteins , Optics and Photonics , Tumor Suppressor Proteins , Antibodies, Monoclonal , Carrier Proteins/analysis , Fatty Acid-Binding Protein 7 , Fatty Acid-Binding Proteins , Fatty Acids/chemistry , Humans , Microscopy, Atomic Force , Myelin P2 Protein/analysis , Myocardial Infarction/metabolism , Transducers
11.
Biosens Bioelectron ; 15(7-8): 343-53, 2000 Oct.
Article in English | MEDLINE | ID: mdl-11219747

ABSTRACT

Thick film oxygen electrodes manufactured by screen print method have been used as a transducer for a biochemical oxygen demand (BOD) sensor. The kinetics of the immobilized yeast, Arxula adeninivorans (Arxula) has been studied. The apparent KM of immobilized Arxula (> 100 microM) is higher than free cells of Arxula (70 microM). The increase in KM caused by the effect of immobilization extends the linear range of the sensor. End-point measurement and quasi-kinetic measurement have been studied comparatively as measurement procedures with a good correlation. The Vmax for end-point measurement is 790.7 microM/s and that for quasi-kinetic measurement is 537.3 microM/s. The limit of detection is calculated 1.24 mg/l BOD. Using the quasi-kinetic measurement, instead of end-point measurements, the measuring time can be reduced from 5-30 min to 100 s. The sensor layer thickness or increase in the layer of covering gel can increase the KM that is accompanied with the extension of the linear range of the sensor. Nevertheless, increase in the layer of covering gel will not increase the saturation signal. Domestic wastewater was checked by the thick film BOD sensor and the results are satisfactory.


Subject(s)
Bacteria/metabolism , Biosensing Techniques , Oxygen Consumption , Water Pollutants, Chemical/analysis , Biodegradation, Environmental , Gels , Sensitivity and Specificity , Sewage , Time Factors , Yeasts/metabolism
12.
Biosens Bioelectron ; 14(2): 131-8, 1999 Feb.
Article in English | MEDLINE | ID: mdl-10101835

ABSTRACT

A microbial biosensor based on the yeast Arxula adeninivorans LS3 has been developed for measurement of biodegradable substances. Arxula is immobilized in the hydrogel poly(carbamoyl) sulfonate (PCS). The immobilized yeast membrane is placed in front of an oxygen electrode with -600 mV versus Ag/AgCl. Arxula is salt tolerant; it can give a stable signal up to 2.5 M NaCl in sample (120 mM in measuring cell). The sensor's measurements are highly correlated to BOD5 measurements. It has a very high stability which can last for 40 day without any decrease in signal. The linear range of the sensor is up to a corresponding BOD value of 550 mg/l.


Subject(s)
Biosensing Techniques , Yeasts/metabolism , Biodegradation, Environmental , Hydrogels
13.
Biosens Bioelectron ; 15(9-10): 541-7, 2000.
Article in English | MEDLINE | ID: mdl-11419651

ABSTRACT

An electrochemical method for the investigation and comparison of anti-Alzheimer medications that is based on the inhibition of the acetylcholinesterase is presented. The developed amperometric biosensor determines the in-vitro inhibition of the acetylcholinesterase that is co-immobilized with choline oxidase on the working electrode surface of a three-electrode system using gel entrapment. The sensor has been applied to determine the IC50 values of two known and one newly developed Alzheimer remedy. A simultaneous measurement with the photometric standard method shows the applicability of our method for fast drug screening.


Subject(s)
Alzheimer Disease/drug therapy , Biosensing Techniques/methods , Acetylcholinesterase , Alcohol Oxidoreductases , Animals , Cattle , Cholinesterase Inhibitors/pharmacology , Drug Evaluation, Preclinical/methods , Enzymes, Immobilized , Humans , In Vitro Techniques , Rats
14.
Biosens Bioelectron ; 14(3): 295-302, 1999 Mar 15.
Article in English | MEDLINE | ID: mdl-10230029

ABSTRACT

A microbial sensor for rapid measurement of the amount of biodegradable substances based on the salt-tolerant yeast Arxula adeninivorans LS3 has been developed especially for coastal and island regions. Our parameter, the so-called sensorBOD, that is available after only a few minutes, agrees with the 5-day value for the biochemical oxygen demand (BOD5) very well. We have employed the Arxula sensor in the short-time estimation and supervision of the BOD of both domestic and industrial wastewater with high salinity. The novel sensor makes it possible to monitor the different types of wastewater rapidly without pretreatment, and it can be used for an active process control of sewage treatment works. Compared to a commercially available sensor, the novel sensor achieves better agreement between sensorBOD and BOD5 measurements with salt containing samples.


Subject(s)
Ascomycota , Biosensing Techniques , Carbamates/chemistry , Environmental Monitoring/methods , Polyesters/chemistry , Seawater , Sodium Chloride/pharmacology , Waste Disposal, Fluid , Biodegradation, Environmental , Linear Models
15.
Biosens Bioelectron ; 6(3): 245-53, 1991.
Article in English | MEDLINE | ID: mdl-1652986

ABSTRACT

Enzyme-membrane electrodes using glucose oxidase in combination with peroxide detection dominate in the field of laboratory analyzers for diluted samples. Using the same indication principle, extremely fast responding glucose sensors have been fabricated by covering thin metal electrodes with a porous enzyme layer. In the second generation auxiliary enzymes and/or co-reactants are coimmobilized with the analyte converting enzyme in order to improve the analytical quality and to simplify the performance. Following this line oxidizable interferences are suppressed by using a glucose oxidase/peroxidase complex which communicates with the electrode at a low working potential. Furthermore, fluctuations of pH or buffer capacity are ineffective when using a glucose oxidase/peroxidase layer covered fluoride FET in the potentiometric glucose determination. Enzymatic recycling of the analyte and/or accumulation of intermediates increase the sensitivity by several orders of magnitude. Inclusion of NAD bound to PEG in the glucose dehydrogenase layer allows a reagentless glucose measurement.


Subject(s)
Biosensing Techniques , Biotechnology , Glucose/analysis , Glucose Oxidase , NAD , Oxidation-Reduction , Peroxidase
16.
J Biotechnol ; 21(1-2): 173-85, 1991 Nov.
Article in English | MEDLINE | ID: mdl-1367688

ABSTRACT

Enzyme sensors for glucose, lactate and glutamine were connected via flow-injection analysis (FIA) devices to two different bioprocesses. They were used for on-line process control of perfused bioreactor systems containing mammalian cell lines producing a monoclonal antibody and recombinant interleukin-2. The biosensor system gives direct access to important process data which can be used as control parameters for long term cell cultivation systems.


Subject(s)
Biosensing Techniques , Glucose/analysis , Glutamine/analysis , Lactates/analysis , Animals , Calibration , Cells, Cultured , Interleukin-2/biosynthesis , Lactic Acid , Mice , Online Systems , Rats
17.
Pharmazie ; 33(7): 415-8, 1978 Jul.
Article in English | MEDLINE | ID: mdl-31630

ABSTRACT

Extrapolating the recent progress in the near future the extensive utilization of cofactor-dependent enzymes (enzymes of the 3rd generation) for solving economic or medical problems will be restricted by the difficulties of cofactor regeneration. Real possibilities exist in analytical systems, for instance enzyme electrodes. In the present paper a special case of overcoming the cofactor regeneration in P-450 catalyzed substrate hydroxylation is demonstrated: The peroxide-dependent reaction gives the same products as obtained under physiological conditions; that is why in an electro-enzyme-reactor producing hydrogen peroxide by cathodic oxygen reduction a considerable simplification of the multi-enzyme complex is possible by omitting electron transfer proteins. At present the main problem is the instability of the terminal oxidase. Attempts are being made to solve these problems by immobilizing the protein or substituting P-450 by other hemoproteins or iron porphyrin derivatives.


Subject(s)
Cytochrome P-450 Enzyme System/metabolism , Animals , Hemeproteins/metabolism , Hemin/metabolism , Humans , Hydroxylation , NAD/metabolism , NADP/metabolism , Oxidoreductases/metabolism , Peroxides/metabolism
18.
Biosens Bioelectron ; 26(7): 3148-53, 2011 Mar 15.
Article in English | MEDLINE | ID: mdl-21236657

ABSTRACT

A novel class of organic nanoparticles as biolabels that can generate an instant visible signal was applied to immunodipsticks. A new principle for signal generation based on hydrolysis of colourless signal precursor molecules to produce coloured signal molecules followed by signal precipitation and localization was demonstrated. The nanoparticle biolabels were applied to sandwich immunoassays for the detection of mouse immunoglobulin G (M IgG). In the presence of M IgG, a nanoparticle-immunocomplex was formed and bound on the test zone immobilized with goat anti M IgG (Gt α M IgG). A blue line was developed on the test zone upon the addition of a signal developing reagent. An optical signal could be simply assessed using naked eyes or quantified using a reading device. The lowest visible signal that could be observed using naked eyes was found to be 1.25 µg L(-1) M IgG. The nanoparticle biolabel also showed a better sensitivity (signal-to-noise ratio) compared with the conventional colloidal gold biolabel. This novel class of organic nanoparticles offers an alternative biolabel system for the development of point-of-care immunodipsticks.


Subject(s)
Coloring Agents/chemistry , Immunoassay/instrumentation , Immunoglobulin G/analysis , Indoles/chemistry , Nanoparticles/chemistry , Animals , Chromatography , Indigo Carmine , Mice , Nanoparticles/ultrastructure , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL