Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 66
Filter
Add more filters

Country/Region as subject
Publication year range
1.
J Cardiovasc Electrophysiol ; 35(5): 994-1004, 2024 May.
Article in English | MEDLINE | ID: mdl-38501333

ABSTRACT

INTRODUCTION: When ventricular tachycardia (VT) recurs after standard RF ablation (sRFA) some patients benefit from repeat sRFA, whereas others warrant advanced methods such as intramural needle ablation (INA). Our objectives are to assess the utility of repeat sRFA and to clarify the benefit of INA when repeat sRFA fails in patients with VT due to structural heart disease. METHODS: In consecutive patients who were prospectively enrolled in a study for INA for recurrent sustained monomorphic VT despite sRFA, repeat sRFA was considered first. INA was performed during the same procedure if repeat sRFA failed or no targets for sRFA were identified. RESULTS: Of 85 patients enrolled, acute success with repeat sRFA was achieved in 30 patients (35%), and during the 6-month follow-up, 87% (20/23) were free of VT hospitalization, 78% were free of any VT, and 7 were lost to follow-up. INA was performed in 55 patients (65%) after sRFA failed, or no endocardial targets were found abolished or modified inducible VT in 35/55 patients (64%). During follow-up, 72% (39/54) were free of VT hospitalization, 41% were free of any VT, and 1 was lost to follow-up. Overall, 59 out of 77 (77%) patients were free of hospitalization and 52% were free of any VT. Septal-origin VTs were more likely to need INA, whereas RV and papillary muscle VTs were less likely to require INA. CONCLUSIONS: Repeat sRFA was beneficial in 23% (18/77) of patients with recurrent sustained VT who were referred for INA. The availability of INA increased favorable outcomes to 52%.


Subject(s)
Catheter Ablation , Cicatrix , Recurrence , Reoperation , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Male , Female , Middle Aged , Aged , Prospective Studies , Catheter Ablation/adverse effects , Cicatrix/physiopathology , Cicatrix/diagnosis , Cicatrix/surgery , Cicatrix/etiology , Time Factors , Action Potentials , Needles , Heart Rate , Risk Factors , Treatment Outcome
2.
Europace ; 26(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38367008

ABSTRACT

AIMS: Failure of radiofrequency (RF) ablation of ventricular arrhythmias is often due to inadequate lesion size. Irrigated RF ablation with half-normal saline (HNS) has the potential to increase lesion size and reduce sodium delivery to the patient if the same volume of RF irrigant were used for normal saline (NS) and HNS but could increase risks related to steam pops and lesion size. This study aims to assess periprocedural complications and acute ablation outcome of ventricular arrhythmias ablation with HNS. METHODS AND RESULTS: Prospective assessment of outcomes was performed in 1024 endocardial and/or epicardial RF ablation procedures in 935 consecutive patients (median age 64 years, 71.2% men, 73.4% cardiomyopathy, 47.2% sustained ventricular tachycardia). Half-normal saline was selected at the discretion of the treating physician. Radiofrequency ablation power was generally titrated to a ≤15â€…Ω impedance fall with intracardiac echocardiography monitoring. Half-normal saline was used in 900 (87.9%) and NS in 124 (12.1%) procedures. Any adverse event within 30 days occurred in 13.0% of patients treated with HNS RF ablation including 4 (0.4%) strokes/transient ischaemic attacks and 34 (3.8%) pericardial effusions requiring treatment (mostly related to epicardial access). Two steam pops with perforation required surgical repair (0.2%). Patients who received NS irrigation had less severe disease and arrhythmias. In multivariable models, adverse events and acute success of the procedure were not related to the type of irrigation. CONCLUSION: Half-normal saline irrigation RF ablation with power guided by impedance fall and intracardiac echocardiography has an acceptable rate of complications and acute ablation success while administering half of the saline load expected for NS irrigation.


Subject(s)
Catheter Ablation , Radiofrequency Ablation , Tachycardia, Ventricular , Male , Humans , Middle Aged , Female , Saline Solution/adverse effects , Steam , Prospective Studies , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Tachycardia, Ventricular/surgery , Therapeutic Irrigation/adverse effects
3.
J Cardiovasc Electrophysiol ; 34(3): 769-774, 2023 03.
Article in English | MEDLINE | ID: mdl-36682066

ABSTRACT

Most currently available pacing and defibrillation leads utilize a stylet-based design that facilitates implantation. This has advantages, but also increases the lead diameter and adds the potential for metal fatigued-based conductor failure. A systematic literature search was conducted, and the authors add their twenty-year experience with this lead design. The global experience with lumenless leads was reviewed both for "standard" positioning and with conduction system pacing. Methods for both placement and system modification are reviewed. Lumenless leads have the potential to improve the durability of endocardial pacing and facilitate conduction system pacing.


Subject(s)
Pacemaker, Artificial , Humans , Equipment Design , Cardiac Pacing, Artificial/methods , Prosthesis Implantation/methods , Cardiac Conduction System Disease
4.
J Cardiovasc Electrophysiol ; 34(11): 2403-2405, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37787011

ABSTRACT

INTRODUCTION: Intracardiac echocardiography (ICE) reveals mobile thrombus on implantable electronic device leads in some patients undergoing electrophysiologic procedures. METHODS: ICE was performed in a patient undergoing ventricular tachycardia (VT) ablation. RESULTS: ICE showed extensive mobile thrombi on the implantable cardioverter defibrillator lead. Radiofrequency catheter ablation of VT from perimitral scar was safely performed via a retrograde aortic approach. After the procedure, chronic anticoagulation was initiated. CT-angiography of the chest 2 months later showed no pulmonary emboli. CONCLUSIONS: The significance of these thrombi, as related to chronic pulmonary embolization, warrants further study.


Subject(s)
Catheter Ablation , Heart Diseases , Tachycardia, Ventricular , Thrombosis , Humans , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery , Wind , Heart Diseases/surgery , Thrombosis/diagnostic imaging , Thrombosis/etiology , Catheter Ablation/methods , Hair , Treatment Outcome
5.
J Cardiovasc Electrophysiol ; 33(12): 2658-2662, 2022 12.
Article in English | MEDLINE | ID: mdl-36125446

ABSTRACT

INTRODUCTION: Leadless pacemakers represent an increasingly utilized alternative to traditional pacing methods in those with prior bacteremia or at high risk for infection. The acknowledged resistance to infection is illustrated by the exceedingly rare documentation of it. METHODS: We present a case of methicillin-sensitive Staphylococcus aureus endocarditis with associated leadless pacemaker infection necessitating percutaneous aspiration of the device-associated vegetation followed by extraction of the leadless pacemaker. RESULTS: Large vegetation associated with a leadless pacemaker was percutaneously aspirated with a vacuum-assisted aspiration device, followed by successful extraction of the leadless pacemaker. CONCLUSION: While leadless pacemakers are seldom involved in infective endocarditis, ultrasound evaluation in high-risk patients with an undetermined source is reasonable. Before extraction, it is practical to consider aspiration of large associated vegetations with a vacuum-assisted device.


Subject(s)
Endocarditis, Bacterial , Endocarditis , Pacemaker, Artificial , Humans , Treatment Outcome , Pacemaker, Artificial/adverse effects , Device Removal/methods , Endocarditis, Bacterial/diagnosis , Endocarditis, Bacterial/therapy , Postoperative Complications/etiology , Equipment Design
6.
J Cardiovasc Electrophysiol ; 33(8): 1655-1664, 2022 08.
Article in English | MEDLINE | ID: mdl-35598280

ABSTRACT

INTRODUCTION: To target posterior wall isolation (PWI) in atrial fibrillation (AF) ablation, diffuse ablation theoretically confers a lower risk of conduction recovery compared to box set. We sought to assess the safety and efficacy of diffuse PWI with low-flow, medium-power, and short-duration (LF-MPSD) ablation, and evaluate the durability of pulmonary vein isolation (PVI) and PWI among patients undergoing repeat ablations. METHODS: We retrospectively studied patients undergoing LF-MPSD ablation for AF (PVI + diffuse PWI) between August 2017 and December 2019. Clinical characteristics were collected. Kaplan-Meier survival analysis was performed to study AF/atrial flutter (AFL) recurrence. Ablation data were analyzed in patients who underwent a repeat AF/AFL ablation. RESULTS: Of the 463 patients undergoing LF-MPSD AF ablation (PVI alone, or PVI + diffuse PWI), 137 patients had PVI + diffuse PWI. Acute PWI with complete electrocardiogram elimination was achieved in 134 (97.8%) patients. Among the 126 patients with consistent follow-up, 38 (30.2%) patients had AF/AFL recurrence during a median duration of 14 months. Eighteen patients underwent a repeat AF/AFL ablation after PVI + diffuse PWI, and 16 (88.9%) patients had durable PVI, in contrast to 10 of 45 (23.9%) patients who had redo ablation after LF-MPSD PVI alone. Seven patients (38.9%) had durable PWI, while 11 patients had partial electrical recovery at the posterior wall. The median percentage of area without electrical activity at the posterior wall was 70.7%. Conduction block across the posterior wall was maintained in 16 (88.9%) patients. CONCLUSION: There was a high rate of PVI durability in patients undergoing diffuse PWI and PVI. Partial posterior wall electrical recovery was common but conduction block across the posterior wall was maintained in most patients.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/etiology , Atrial Fibrillation/surgery , Atrial Flutter/diagnosis , Atrial Flutter/etiology , Atrial Flutter/surgery , Catheter Ablation/adverse effects , Humans , Pulmonary Veins/surgery , Recurrence , Retrospective Studies , Treatment Outcome
7.
J Cardiovasc Electrophysiol ; 32(9): 2604-2606, 2021 09.
Article in English | MEDLINE | ID: mdl-34314062

ABSTRACT

INTRODUCTION: Ventricular tachycardia (VT) normally occurs from an abnormal structural substrate. CASE: We report a case in which VT was caused by a large tumor in the interventricular septum. Surgical intervention was not an option due to the location of the tumor and its proximity to the coronary arteries. CONCLUSION: The patient underwent ablation and upgrade to CRT before ultimately receiving a heart transplant.


Subject(s)
Catheter Ablation , Heart Neoplasms , Tachycardia, Ventricular , Ventricular Septum , Coronary Vessels , Heart Neoplasms/complications , Heart Neoplasms/diagnostic imaging , Heart Neoplasms/surgery , Humans , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/etiology , Treatment Outcome
8.
J Cardiovasc Electrophysiol ; 31(7): 1864-1866, 2020 Jul.
Article in English | MEDLINE | ID: mdl-31578754

ABSTRACT

In patients with persistent atrial fibrillation (AF) despite durable pulmonary vein isolation, there are a variety of approaches to further ablation. Here we summarize our strategy in this population. In brief, our approach is to isolate the posterior wall, ablate the coronary sinus musculature and left lateral ridge, complete a lateral mitral line, and achieve cavotricuspid isthmus block. Subsequently, we target organized atrial flutters and if AF persists, we ablate areas of long, fractionated electrograms within scarred regions. We administer isuprel in patients with a presentation consistent with triggered atrial fibrillation (low scar burden, paroxysms of AF).


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Electrophysiologic Techniques, Cardiac , Humans , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Treatment Outcome
9.
J Cardiovasc Electrophysiol ; 31(3): 718-722, 2020 03.
Article in English | MEDLINE | ID: mdl-32003095

ABSTRACT

INTRODUCTION: The optimal approach to the extraction of leads with large vegetations remains uncertain. METHODS: High-risk patients with lead associated vegetations undergoing device extraction at Vanderbilt Hospital with concomitant use of the Penumbra Aspiration System (Penumbra Inc, Alameda, CA) are described. An 8.5 Fr Agilis NXT (Abbott Inc, St. Paul, MN) was advanced to the right atrium, through which a Penumbra Indigo Cat-8 catheter was advanced. Using intracardiac echocardiography, the Penumbra was positioned directly on the vegetation, suction was applied until adherent, and the Indigo catheter and Agilis sheath were then removed en-bloc and aspirated debris flushed out. This was repeated until debulking was considered successful. RESULTS: Eight cases were performed. The median vegetation size was 2 cm. Pathogens were Enterococcus, Staphylococcus, Candida, Cutibacterium, and Enterobacter. In seven of eight cases, aspiration successfully reduced vegetations to less than 1 cm before successful percutaneous cardiac implantable electronic device removal. One patient underwent surgical removal via thoracotomy. There were no acute complications related to the Penumbra catheter. Three patients had CT evidence of small pulmonary emboli postprocedure. The length of stay was 3 to 27 days. One patient died on POD 1 of refractory ventricular tachycardia unrelated to the procedure. One patient died of ongoing sepsis 2 weeks postextraction. CONCLUSIONS: The Penumbra Indigo Aspiration system can be useful for vegetation debulking before transvenous lead extraction.


Subject(s)
Defibrillators, Implantable/adverse effects , Device Removal/instrumentation , Endocarditis, Bacterial/surgery , Pacemaker, Artificial/adverse effects , Prosthesis-Related Infections/surgery , Thrombectomy/instrumentation , Adult , Aged , Aged, 80 and over , Databases, Factual , Device Removal/adverse effects , Endocarditis, Bacterial/diagnosis , Endocarditis, Bacterial/microbiology , Female , Humans , Male , Middle Aged , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/microbiology , Risk Factors , Suction/instrumentation , Thrombectomy/adverse effects , Treatment Outcome
10.
J Cardiovasc Electrophysiol ; 30(11): 2501-2507, 2019 11.
Article in English | MEDLINE | ID: mdl-31515883

ABSTRACT

INTRODUCTION: Hyponatremia commonly follows percutaneous exclusion of the left atrial appendage (LAA) with the LARIAT suture delivery device. The aim of this study was to evaluate for clinical predictors hyponatremia following ligation of the appendage with the LARIAT device. METHODS AND RESULTS: A retrospective analysis was conducted on 61 consecutive patients (average age 69.7 ± 9.8 years, 55.7% male) who underwent successful appendage ligation with the LARIAT device. Acute hyponatremia (AH) was defined as a drop in serum sodium (Na) by greater than or equal to 4 mmol/L within 48 hours of ligation while exaggerated acute hyponatremia (EAH) was defined as a drop greater than or equal to 10 mmol/L. Among all patients, there was a significant decrease in [Na] at 24 hours (3.26 ± 2.77 mmol/L) and 48 hours (4.98 ± 3.74 mmol/L). Thirty-two patients (52.4%) had AH while six patients (9.8%) experienced EAH. A body mass index (BMI) of less than 28.4 kg/m2 was associated with AH (P = .037) while a BMI < 25 kg/m2 was associated with EAH (P = .021). A linear regression analysis comparing the maximum sodium decrease to the indexed left atrial (LA) diameter found that for every 1 cm/m2 increase in indexed LA diameter, there was a 2.5 mEq/L decrease in serum sodium (P = .04). CONCLUSIONS: Hyponatremia frequently occurs following LAA ligation with the LARIAT device. A low BMI < 25 kg/m2 is associated with a drop in serum sodium of greater than 10 mmol/L while increasing indexed LA diameter predicts any AH. AH is also associated with a significantly lower systolic blood pressure 48 to 72 hours post LAA exclusion with the LARIAT device.


Subject(s)
Atrial Appendage/surgery , Atrial Fibrillation/surgery , Cardiac Surgical Procedures/adverse effects , Cardiac Surgical Procedures/instrumentation , Hyponatremia/etiology , Sodium/blood , Acute Disease , Aged , Aged, 80 and over , Atrial Appendage/physiopathology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Atrial Function, Left , Biomarkers/blood , Blood Pressure , Body Mass Index , Female , Humans , Hyponatremia/blood , Hyponatremia/diagnosis , Ligation , Male , Middle Aged , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL