Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Pediatr Emerg Care ; 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38950383

ABSTRACT

OBJECTIVES: The aim of this study was to create and validate a 3-dimensional (3D) ultrasound model with normal and abnormal pediatric hip joint anatomy that is comparable to a pediatric hip joint in appearance and anatomy and replicates sonographic characteristics of a pediatric hip joint. METHODS: A 3D rendering of the bone and soft tissue was created from a computed tomography pelvic scan of a pediatric patient. This rendering was modified to include a unilateral joint effusion. The bone was 3D printed with a photopolymer plastic, whereas the soft tissue was cast with a silicone mixture in a 3D-printed mold. The effusion was simulated by injecting saline into the soft tissue cavity surrounding the bone. The ultrasound model was validated by pediatric point-of-care ultrasonographers at an international pediatric ultrasound conference. RESULTS: A pediatric hip ultrasound model was developed that simulates both normal and abnormal pediatric hip joint anatomy, each with an appropriately sized, measurable joint effusion. Validation by pediatric point-of-care ultrasonographers showed that the key aspects of a normal pediatric hip joint (femoral physis, sloped femoral neck, and adequate soft tissue) with an identifiable and measurable effusion were included in the ultrasound model. CONCLUSIONS: In this study, we successfully created a cost-effective, reusable, and reproducible 3D pediatric hip ultrasound model. The majority of pediatric point-of-care ultrasonographers who evaluated the model agreed that this model is comparable to a pediatric patient for the purpose of teaching ultrasound skills and joint space measurement.

2.
Pediatr Transplant ; 22(8): e13290, 2018 12.
Article in English | MEDLINE | ID: mdl-30251298

ABSTRACT

BACKGROUND: Listed pediatric heart transplant patients have the highest solid-organ waitlist mortality rate. The donor-recipient body weight (DRBW) ratio is the clinical standard for allograft size matching but may unnecessarily limit a patient's donor pool. To overcome DRBW ratio limitations, two methods of performing virtual heart transplant fit assessments were developed that account for patient-specific nuances. Method 1 uses an allograft total cardiac volume (TCV) prediction model informed by patient data wherein a matched allograft 3-D reconstruction is selected from a virtual library for assessment. Method 2 uses donor images for a direct virtual transplant assessment. METHODS: Assessments were performed in medical image reconstruction software. The allograft model was developed using allometric/isometric scaling assumptions and cross-validation. RESULTS: The final predictive model included gender, height, and weight. The 25th-, 50th-, and 75th-percentiles for TCV percentage errors were -13% (over-prediction), -1%, and 8% (under-prediction), respectively. Two examples illustrating the potential of virtual assessments are presented. CONCLUSION: Transplant centers can apply these methods to perform their virtual assessments using existing technology. These techniques have potential to improve organ allocation. With additional experience and refinement, virtual transplants may become standard of care for determining suitability of donor organ size for an identified recipient.


Subject(s)
Heart Transplantation/methods , Heart/anatomy & histology , Organ Size , Tissue and Organ Procurement/methods , Adolescent , Adult , Allografts , Cardiac Volume , Child , Child, Preschool , Diagnostic Imaging , Female , Humans , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional , Infant , Magnetic Resonance Imaging , Male , Retrospective Studies , Tissue Donors , Tomography, X-Ray Computed , Waiting Lists , Young Adult
3.
Interv Cardiol Clin ; 13(3): 421-430, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38839174

ABSTRACT

Since PDA stenting was first attempted in the early 1990s, significant technical advancements have improved outcomes and some centers have even transitioned to exclusive PDA stenting for all infants with duct-dependent pulmonary circulation. In addition to its use in infants with duct-dependent pulmonary circulation, PDA stenting has also been adapted as a percutaneous palliative option for suprasystemic pulmonary arterial hypertension and as a component of the hybrid procedure. In this article, the authors aim to review indications and outcomes for PDA stenting, describe the procedure, and discuss future directions.


Subject(s)
Ductus Arteriosus, Patent , Stents , Humans , Ductus Arteriosus, Patent/surgery , Cardiac Catheterization/methods , Palliative Care/methods , Treatment Outcome
4.
3D Print Med ; 10(1): 3, 2024 Jan 29.
Article in English | MEDLINE | ID: mdl-38282094

ABSTRACT

BACKGROUND: The use of medical 3D printing (focusing on anatomical modeling) has continued to grow since the Radiological Society of North America's (RSNA) 3D Printing Special Interest Group (3DPSIG) released its initial guideline and appropriateness rating document in 2018. The 3DPSIG formed a focused writing group to provide updated appropriateness ratings for 3D printing anatomical models across a variety of congenital heart disease. Evidence-based- (where available) and expert-consensus-driven appropriateness ratings are provided for twenty-eight congenital heart lesion categories. METHODS: A structured literature search was conducted to identify all relevant articles using 3D printing technology associated with pediatric congenital heart disease indications. Each study was vetted by the authors and strength of evidence was assessed according to published appropriateness ratings. RESULTS: Evidence-based recommendations for when 3D printing is appropriate are provided for pediatric congenital heart lesions. Recommendations are provided in accordance with strength of evidence of publications corresponding to each cardiac clinical scenario combined with expert opinion from members of the 3DPSIG. CONCLUSIONS: This consensus appropriateness ratings document, created by the members of the RSNA 3DPSIG, provides a reference for clinical standards of 3D printing for pediatric congenital heart disease clinical scenarios.

5.
JACC Case Rep ; 10: 101760, 2023 Mar 15.
Article in English | MEDLINE | ID: mdl-36974056

ABSTRACT

The authors report a closed-chest, transcatheter large-vessel connection (hepatic conduit to azygous vein) to reverse pulmonary arteriovenous malformations in a 10-year-old patient after Fontan for heterotaxy/interrupted inferior vena cava, with an increase in oxygen saturation from 78% to 96%. Computational fluid dynamics estimated a 14-fold increase in hepatic blood flow to the left pulmonary artery (from 1.3% to 14%). (Level of Difficulty: Advanced.).

6.
3D Print Med ; 9(1): 8, 2023 Mar 23.
Article in English | MEDLINE | ID: mdl-36952139

ABSTRACT

The use of medical 3D printing has expanded dramatically for breast diseases. A writing group composed of the Radiological Society of North America (RSNA) Special Interest Group on 3D Printing (SIG) provides updated appropriateness criteria for breast 3D printing in various clinical scenarios. Evidence-based appropriateness criteria are provided for the following clinical scenarios: benign breast lesions and high-risk breast lesions, breast cancer, breast reconstruction, and breast radiation (treatment planning and radiation delivery).

7.
3D Print Med ; 9(1): 34, 2023 Nov 30.
Article in English | MEDLINE | ID: mdl-38032479

ABSTRACT

BACKGROUND: Medical three-dimensional (3D) printing has demonstrated utility and value in anatomic models for vascular conditions. A writing group composed of the Radiological Society of North America (RSNA) Special Interest Group on 3D Printing (3DPSIG) provides appropriateness recommendations for vascular 3D printing indications. METHODS: A structured literature search was conducted to identify all relevant articles using 3D printing technology associated with vascular indications. Each study was vetted by the authors and strength of evidence was assessed according to published appropriateness ratings. RESULTS: Evidence-based recommendations for when 3D printing is appropriate are provided for the following areas: aneurysm, dissection, extremity vascular disease, other arterial diseases, acute venous thromboembolic disease, venous disorders, lymphedema, congenital vascular malformations, vascular trauma, vascular tumors, visceral vasculature for surgical planning, dialysis access, vascular research/development and modeling, and other vasculopathy. Recommendations are provided in accordance with strength of evidence of publications corresponding to each vascular condition combined with expert opinion from members of the 3DPSIG. CONCLUSION: This consensus appropriateness ratings document, created by the members of the 3DPSIG, provides an updated reference for clinical standards of 3D printing for the care of patients with vascular conditions.

8.
Cardiovasc Revasc Med ; 34: 128-133, 2022 01.
Article in English | MEDLINE | ID: mdl-33526391

ABSTRACT

BACKGROUND/PURPOSE: Patients with a functional single ventricle undergo multiple, palliative open-heart surgeries. This includes a superior cavopulmonary anastomosis or bidirectional Glenn shunt. A less-invasive transcatheter approach may reduce morbidity. METHODS/MATERIALS: We analyzed pre-Glenn X-ray contrast angiography (XA), cardiac computed tomography (CT), and cardiac magnetic resonance (CMR) studies. RESULTS: Over an eleven-year period (1/2007 - 6/2017), 139 Glenn surgeries were performed at our institution. The typical age range at surgery was 59 - 371 days (median = 163; IQR = 138 - 203). Eight-nine XA, ten CT, and ten CMR studies obtained from these patients were analyzed. Cephalad SVC measurements (millimeters) were 7.3 ± 1.7 (XA), 7.7 ± 1.6 (CT) and 6.9 ± 1.8 (CMR). RPA measurements were 7.3 ± 1.9 (XA), 7.4 ± 1.6 (CT) and 6.6 ± 1.9 (CMR). Potential device lengths were 10.9 ± 6 - 17.4 ± 6.4 (XA), 10.1 ± 2.1 - 17.7 ± 2.4 (CT) and 17.3 ± 4. - 23.7 ± 5.5 (CMR). SVC-RPA angle (degrees) was 132.9 ± 13.2 (CT) and 140 ± 10.2 (MRI). Image quality of all CT (100%), almost all XA (SVC 100%, RPA 99%), and most MRI (SVC 80%, RPA 90%) were deemed sufficient. Parametric modeling virtual fit device with 10 mm diameter and 20 - 25 mm length was ideal. CONCLUSIONS: Ideal transcatheter cavopulmonary shunt device for the typical patient would be 10 mm in diameter and 20-25 mm in length.


Subject(s)
Fontan Procedure , Heart Bypass, Right , Heart Defects, Congenital , Fontan Procedure/adverse effects , Fontan Procedure/methods , Heart Bypass, Right/adverse effects , Heart Bypass, Right/methods , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery , Humans , Multimodal Imaging , Pulmonary Artery , Retrospective Studies
9.
Cell Rep Med ; 2(7): 100348, 2021 07 20.
Article in English | MEDLINE | ID: mdl-34337564

ABSTRACT

3D visualization technologies such as virtual reality (VR), augmented reality (AR), and mixed reality (MR) have gained popularity in the recent decade. Digital extended reality (XR) technologies have been adopted in various domains ranging from entertainment to education because of their accessibility and affordability. XR modalities create an immersive experience, enabling 3D visualization of the content without a conventional 2D display constraint. Here, we provide a perspective on XR in current biomedical applications and demonstrate case studies using cell biology concepts, multiplexed proteomics images, surgical data for heart operations, and cardiac 3D models. Emerging challenges associated with XR technologies in the context of adverse health effects and a cost comparison of distinct platforms are discussed. The presented XR platforms will be useful for biomedical education, medical training, surgical guidance, and molecular data visualization to enhance trainees' and students' learning, medical operation accuracy, and the comprehensibility of complex biological systems.


Subject(s)
Augmented Reality , Biomedical Technology , Virtual Reality , Biomedical Technology/economics , Costs and Cost Analysis , Emotions , Humans , Learning
10.
JACC Case Rep ; 2(11): 1734-1735, 2020 Sep.
Article in English | MEDLINE | ID: mdl-33000000

ABSTRACT

Limited arterial vascular access precluded necessary transcatheter intervention in a 22-year-old woman with repaired interrupted aortic arch type B. Alternative transcaval vascular access enabled percutaneous therapy. This practice evolution is likely to benefit the growing numbers of adults with congenital heart disease. (Level of Difficulty: Advanced.).

11.
World Neurosurg ; 88: 175-181, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26805698

ABSTRACT

BACKGROUND: Neurosurgery simulator development is growing as practitioners recognize the need for improved instructional and rehearsal platforms to improve procedural skills and patient care. In addition, changes in practice patterns have decreased the volume of specific cases, such as aneurysm clippings, which reduces the opportunity for operating room experience. OBJECTIVE: The authors developed a hands-on, dimensionally accurate model for aneurysm clipping using patient-derived anatomic data and three-dimensional (3D) printing. Design of the model focused on reproducibility as well as adaptability to new patient geometry. METHODS: A modular, reproducible, and patient-derived medical simulacrum was developed for medical learners to practice aneurysmal clipping procedures. Various forms of 3D printing were used to develop a geometrically accurate cranium and vascular tree featuring 9 patient-derived aneurysms. 3D printing in conjunction with elastomeric casting was leveraged to achieve a patient-derived brain model with tactile properties not yet available from commercial 3D printing technology. An educational pilot study was performed to gauge simulation efficacy. RESULTS: Through the novel manufacturing process, a patient-derived simulacrum was developed for neurovascular surgical simulation. A follow-up qualitative study suggests potential to enhance current educational programs; assessments support the efficacy of the simulacrum. CONCLUSIONS: The proposed aneurysm clipping simulator has the potential to improve learning experiences in surgical environment. 3D printing and elastomeric casting can produce patient-derived models for a dynamic learning environment that add value to surgical training and preparation.


Subject(s)
Intracranial Aneurysm/pathology , Intracranial Aneurysm/surgery , Models, Anatomic , Neurosurgery/education , Patient-Specific Modeling , Printing, Three-Dimensional , Humans , Silicones/chemistry , Vascular Surgical Procedures/methods
12.
World Neurosurg ; 84(5): 1333-9, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26100167

ABSTRACT

BACKGROUND: Educational simulators provide a means for students and experts to learn and refine surgical skills. Educators can leverage the strengths of medical simulators to effectively teach complex and high-risk surgical procedures, such as placement of an external ventricular drain. OBJECTIVE: Our objective was to develop a cost-effective, patient-derived medical simulacrum for cerebral lateral ventriculostomy. METHODS: A cost-effective, patient-derived medical simulacrum was developed for placement of an external lateral ventriculostomy. Elastomeric and gel casting techniques were used to achieve realistic brain geometry and material properties. 3D printing technology was leveraged to develop accurate cranial properties and dimensions. An economical, gravity-driven pump was developed to provide normal and abnormal ventricular pressures. A small pilot study was performed to gauge simulation efficacy using a technology acceptance model. RESULTS: An accurate geometric representation of the brain was developed with independent lateral cerebral ventricular chambers. A gravity-driven pump pressurized the ventricular cavities to physiologic values. A qualitative study illustrated that the simulation has potential as an educational tool to train medical professionals in the ventriculostomy procedure. CONCLUSION: The ventricular simulacrum can improve learning in a medical education environment. Rapid prototyping and multi-material casting techniques can produce patient-derived models for cost-effective and realistic surgical training scenarios.


Subject(s)
Cerebral Ventricles/anatomy & histology , Models, Anatomic , Printing, Three-Dimensional , Ventriculostomy/methods , Attitude of Health Personnel , Humans , Hydrogels , Lateral Ventricles/anatomy & histology , Magnetic Resonance Imaging , Neurosurgery/education , Pilot Projects , Students, Medical , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL