Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
J Anat ; 239(2): 251-263, 2021 08.
Article in English | MEDLINE | ID: mdl-33782948

ABSTRACT

Structural dynamics of calcified cartilage (CC) are poorly understood. Conventionally, CC structure is analyzed using histological sections. Micro-computed tomography (µCT) allows for three-dimensional (3D) imaging of mineralized tissues; however, the segmentation between bone and mineralized cartilage is challenging. Here, we present state-of-the-art deep learning segmentation for µCT images to assess 3D CC morphology. The sample includes 16 knees from 12 New Zealand White rabbits dissected into osteochondral samples from six anatomical regions: lateral and medial femoral condyles, lateral and medial tibial plateaus, femoral groove, and patella (n = 96). The samples were imaged with µCT and processed for conventional histology. Manually segmented CC from the images was used to train segmentation models with different encoder-decoder architectures. The models with the greatest out-of-fold evaluation Dice score were selected. CC thickness was compared across 24 regions, co-registered between the imaging modalities using Pearson correlation and Bland-Altman analyses. Finally, the anatomical CC thickness variation was assessed via a Linear Mixed Model analysis. The best segmentation models yielded average Dice of 0.891 and 0.807 for histology and µCT segmentation, respectively. The correlation between the co-registered regions was strong (r = 0.897, bias = 21.9 µm, standard deviation = 21.5 µm). Finally, both methods could separate the CC thickness between the patella, femoral, and tibial regions (p < 0.001). As a conclusion, the proposed µCT analysis allows for ex vivo 3D assessment of CC morphology. We demonstrated the biomedical relevance of the method by quantifying CC thickness in different anatomical regions with a varying mean thickness. CC was thickest in the patella and thinnest in the tibial plateau. Our method is relatively straightforward to implement into standard µCT analysis pipelines, allowing the analysis of CC morphology. In future research, µCT imaging might be preferable to histology, especially when analyzing dynamic changes in cartilage mineralization. It could also provide further understanding of 3D morphological changes that may occur in mineralized cartilage, such as thickening of the subchondral plate in osteoarthritis and other joint diseases.


Subject(s)
Cartilage, Articular/diagnostic imaging , Animals , Cartilage, Articular/pathology , Deep Learning , Female , Rabbits , X-Ray Microtomography
2.
Ann Biomed Eng ; 52(5): 1255-1269, 2024 May.
Article in English | MEDLINE | ID: mdl-38361137

ABSTRACT

PURPOSE: Clinical cone-beam computed tomography (CBCT) devices are limited to imaging features of half a millimeter in size and cannot quantify the tissue microstructure. We demonstrate a robust deep-learning method for enhancing clinical CT images, only requiring a limited set of easy-to-acquire training data. METHODS: Knee tissue from five cadavers and six total knee replacement patients, and 14 teeth from eight patients were scanned using laboratory CT as training data for the developed super-resolution (SR) technique. The method was benchmarked against ex vivo test set, 52 osteochondral samples are imaged with clinical and laboratory CT. A quality assurance phantom was imaged with clinical CT to quantify the technical image quality. To visually assess the clinical image quality, musculoskeletal and maxillofacial CBCT studies were enhanced with SR and contrasted to interpolated images. A dental radiologist and surgeon reviewed the maxillofacial images. RESULTS: The SR models predicted the bone morphological parameters on the ex vivo test set more accurately than conventional image processing. The phantom analysis confirmed higher spatial resolution on the SR images than interpolation, but image grayscales were modified. Musculoskeletal and maxillofacial CBCT images showed more details on SR than interpolation; however, artifacts were observed near the crown of the teeth. The readers assessed mediocre overall scores for both SR and interpolation. The source code and pretrained networks are publicly available. CONCLUSION: Model training with laboratory modalities could push the resolution limit beyond state-of-the-art clinical musculoskeletal and dental CBCT. A larger maxillofacial training dataset is recommended for dental applications.


Subject(s)
Cone-Beam Computed Tomography , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Cone-Beam Computed Tomography/methods , Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Head
SELECTION OF CITATIONS
SEARCH DETAIL