Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 677
Filter
Add more filters

Publication year range
1.
Circulation ; 149(18): 1405-1415, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38109351

ABSTRACT

BACKGROUND: Exercise-induced cardiac remodeling can be profound, resulting in clinical overlap with dilated cardiomyopathy, yet the significance of reduced ejection fraction (EF) in athletes is unclear. The aim is to assess the prevalence, clinical consequences, and genetic predisposition of reduced EF in athletes. METHODS: Young endurance athletes were recruited from elite training programs and underwent comprehensive cardiac phenotyping and genetic testing. Those with reduced EF using cardiac magnetic resonance imaging (defined as left ventricular EF <50%, or right ventricular EF <45%, or both) were compared with athletes with normal EF. A validated polygenic risk score for indexed left ventricular end-systolic volume (LVESVi-PRS), previously associated with dilated cardiomyopathy, was assessed. Clinical events were recorded over a mean of 4.4 years. RESULTS: Of the 281 elite endurance athletes (22±8 years, 79.7% male) undergoing comprehensive assessment, 44 of 281 (15.7%) had reduced left ventricular EF (N=12; 4.3%), right ventricular EF (N=14; 5.0%), or both (N=18; 6.4%). Reduced EF was associated with a higher burden of ventricular premature beats (13.6% versus 3.8% with >100 ventricular premature beats/24 h; P=0.008) and lower left ventricular global longitudinal strain (-17%±2% versus -19%±2%; P<0.001). Athletes with reduced EF had a higher mean LVESVi-PRS (0.57±0.13 versus 0.51±0.14; P=0.009) with athletes in the top decile of LVESVi-PRS having an 11-fold increase in the likelihood of reduced EF compared with those in the bottom decile (P=0.034). Male sex and higher LVESVi-PRS were the only significant predictors of reduced EF in a multivariate analysis that included age and fitness. During follow-up, no athletes developed symptomatic heart failure or arrhythmias. Two athletes died, 1 from trauma and 1 from sudden cardiac death, the latter having a reduced right ventricular EF and a LVESVi-PRS >95%. CONCLUSIONS: Reduced EF occurs in approximately 1 in 6 elite endurance athletes and is related to genetic predisposition in addition to exercise training. Genetic and imaging markers may help identify endurance athletes in whom scrutiny about long-term clinical outcomes may be appropriate. REGISTRATION: URL: https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=374976&isReview=true; Unique identifier: ACTRN12618000716268.


Subject(s)
Athletes , Cardiomyopathy, Dilated , Stroke Volume , Humans , Male , Cardiomyopathy, Dilated/genetics , Cardiomyopathy, Dilated/physiopathology , Cardiomyopathy, Dilated/diagnostic imaging , Female , Adult , Young Adult , Physical Endurance/genetics , Adolescent , Genetic Predisposition to Disease , Ventricular Remodeling , Ventricular Function, Left
2.
Circulation ; 149(1): e1-e156, 2024 01 02.
Article in English | MEDLINE | ID: mdl-38033089

ABSTRACT

AIM: The "2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation" provides recommendations to guide clinicians in the treatment of patients with atrial fibrillation. METHODS: A comprehensive literature search was conducted from May 12, 2022, to November 3, 2022, encompassing studies, reviews, and other evidence conducted on human subjects that were published in English from PubMed, EMBASE, the Cochrane Library, the Agency for Healthcare Research and Quality, and other selected databases relevant to this guideline. Additional relevant studies, published through November 2022, during the guideline writing process, were also considered by the writing committee and added to the evidence tables, where appropriate. STRUCTURE: Atrial fibrillation is the most sustained common arrhythmia, and its incidence and prevalence are increasing in the United States and globally. Recommendations from the "2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation" and the "2019 AHA/ACC/HRS Focused Update of the 2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation" have been updated with new evidence to guide clinicians. In addition, new recommendations addressing atrial fibrillation and thromboembolic risk assessment, anticoagulation, left atrial appendage occlusion, atrial fibrillation catheter or surgical ablation, and risk factor modification and atrial fibrillation prevention have been developed.


Subject(s)
Atrial Fibrillation , Cardiology , Thromboembolism , Humans , American Heart Association , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Risk Factors , United States/epidemiology
3.
Eur Heart J ; 2024 Sep 17.
Article in English | MEDLINE | ID: mdl-39288159

ABSTRACT

Atrial fibrillation (AF) is the most prevalent sustained cardiac arrhythmia. Comprehensive modification of established AF risk factors combined with dietary interventions and breaking deleterious habits has been shown to reduce AF burden and recurrence. Numerous AF risk factors, such as diabetes, obesity or hypertension can be partially related to dietary and lifestyle choices. Therefore, dietary interventions may have potential as a therapeutic approach in AF. Based on available data, current guidelines recommend alcohol abstinence or reduction to decrease AF symptoms, burden, and progression, and do not indicate the need for caffeine abstention to prevent AF episodes (unless it is a trigger for AF symptoms). Uncertainty persists regarding harms or benefits of other dietary factors including chocolate, fish, salt, polyunsaturated and monounsaturated fatty acids, vitamins, and micronutrients. This article provides a systematic review of the association between AF and both dietary patterns and components. Additionally, it discusses potentially related mechanisms and introduces different strategies to assess patients' nutrition patterns, including mobile health solutions and diet indices. Finally, it highlights the gaps in knowledge requiring future investigation.

4.
Eur Heart J ; 45(7): 510-518, 2024 Feb 16.
Article in English | MEDLINE | ID: mdl-37624879

ABSTRACT

BACKGROUND AND AIMS: Atrial fibrillation (AF) is a chronic progressive disorder. Persistent forms of AF are associated with increased rates of thromboembolism, heart failure, and death. Catheter ablation modifies the pathogenic mechanism of AF progression. No randomized studies have evaluated the impact of the ablation energy on progression to persistent atrial tachyarrhythmia. METHODS: Three hundred forty-six patients with drug-refractory paroxysmal AF were enrolled and randomly assigned to contact-force-guided RF ablation (CF-RF ablation, 115), 4 min cryoballoon ablation (CRYO-4, 115), or 2 min cryoballoon ablation (CRYO-2, 116). Implantable cardiac monitors placed at study entry were used for follow-up. The main outcome was the first episode of persistent atrial tachyarrhythmia. Secondary outcomes included atrial tachyarrhythmia recurrence and arrhythmia burden on the implantable monitor. RESULTS: At a median of 944.0 (interquartile range [IQR], 612.5-1104) days, 0 of 115 patients (0.0%) randomly assigned to CF-RF, 8 of 115 patients (7.0%) assigned to CRYO-4, and 5 of 116 patients (4.3%) assigned to CRYO-2 experienced an episode of persistent atrial tachyarrhythmia (P = .03). A documented recurrence of any atrial tachyarrhythmia ≥30 s occurred in 56.5%, 53.9%, and 62.9% of those randomized to CF-RF, CRYO-4, and CRYO-2, respectively; P = .65. Compared with that of the pre-ablation monitoring period, AF burden was reduced by a median of 99.5% (IQR 94.0%, 100.0%) with CF-RF, 99.9% (IQR 93.3%-100.0%) with CRYO-4, and 99.1%% (IQR 87.0%-100.0%) with CRYO-2 (P = .38). CONCLUSIONS: Catheter ablation of paroxysmal AF using radiofrequency energy was associated with fewer patients developing persistent AF on follow-up.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Cryosurgery/adverse effects , Treatment Outcome , Catheter Ablation/adverse effects , Tachycardia , Recurrence , Pulmonary Veins/surgery
5.
Eur Heart J ; 45(29): 2604-2616, 2024 Aug 03.
Article in English | MEDLINE | ID: mdl-38759110

ABSTRACT

BACKGROUND AND AIMS: Patterns of atrial fibrillation (AF) recurrence post-catheter ablation for persistent AF (PsAF) are not well described. This study aimed to describe the pattern of AF recurrence seen following catheter ablation for PsAF and the implications for healthcare utilization and quality of life (QoL). METHODS: This was a post-hoc analysis of the CAPLA study, an international, multicentre study that randomized patients with symptomatic PsAF to pulmonary vein isolation plus posterior wall isolation or pulmonary vein isolation alone. Patients underwent twice daily single lead ECG, implantable device monitoring or three monthly Holter monitoring. RESULTS: 154 of 333 (46.2%) patients (median age 67.3 years, 28% female) experienced AF recurrence at 12-month follow-up. Recurrence was paroxysmal in 97 (63%) patients and persistent in 57 (37%). Recurrence type did not differ between randomization groups (P = .508). Median AF burden was 27.4% in PsAF recurrence and .9% in paroxysmal AF (PAF) recurrence (P < .001). Patients with PsAF recurrence had lower baseline left ventricular ejection fraction (PsAF 50% vs. PAF 60%, P < .001) and larger left atrial volume (PsAF 54.2 ± 19.3 mL/m² vs. PAF 44.8 ± 11.6 mL/m², P = .008). Healthcare utilization was significantly higher in PsAF (45 patients [78.9%]) vs. PAF recurrence (45 patients [46.4%], P < .001) and lowest in those without recurrence (17 patients [9.5%], P < .001). Patients without AF recurrence had greater improvements in QoL as assessed by the Atrial Fibrillation Effect on Quality-of-Life (AFEQT) questionnaire (Δ33.3 ± 25.2 points) compared to those with PAF (Δ24.0 ± 25.0 points, P = .012) or PsAF (Δ13.4 ± 22.9 points, P < .001) recurrence. CONCLUSIONS: AF recurrence is more often paroxysmal after catheter ablation for PsAF irrespective of ablation strategy. Recurrent PsAF was associated with higher AF burden, increased healthcare utilization and antiarrhythmic drug use. The type of AF recurrence and AF burden may be considered important endpoints in clinical trials investigating ablation of PsAF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Quality of Life , Recurrence , Humans , Atrial Fibrillation/surgery , Female , Male , Catheter Ablation/methods , Aged , Middle Aged , Pulmonary Veins/surgery , Electrocardiography, Ambulatory , Patient Acceptance of Health Care/statistics & numerical data , Treatment Outcome
6.
Circulation ; 147(19): 1422-1432, 2023 05 09.
Article in English | MEDLINE | ID: mdl-36877118

ABSTRACT

BACKGROUND: Pulsed field ablation uses electrical pulses to cause nonthermal irreversible electroporation and induce cardiac cell death. Pulsed field ablation may have effectiveness comparable to traditional catheter ablation while preventing thermally mediated complications. METHODS: The PULSED AF pivotal study (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF) was a prospective, global, multicenter, nonrandomized, paired single-arm study in which patients with paroxysmal (n=150) or persistent (n=150) symptomatic atrial fibrillation (AF) refractory to class I or III antiarrhythmic drugs were treated with pulsed field ablation. All patients were monitored for 1 year using weekly and symptomatic transtelephonic monitoring; 3-, 6-, and 12-month ECGs; and 6- and 12-month 24-hour Holter monitoring. The primary effectiveness end point was freedom from a composite of acute procedural failure, arrhythmia recurrence, or antiarrhythmic escalation through 12 months, excluding a 3-month blanking period to allow recovery from the procedure. The primary safety end point was freedom from a composite of serious procedure- and device-related adverse events. Kaplan-Meier methods were used to evaluate the primary end points. RESULTS: Pulsed field ablation was shown to be effective at 1 year in 66.2% (95% CI, 57.9 to 73.2) of patients with paroxysmal AF and 55.1% (95% CI, 46.7 to 62.7) of patients with persistent AF. The primary safety end point occurred in 1 patient (0.7%; 95% CI, 0.1 to 4.6) in both the paroxysmal and persistent AF cohorts. CONCLUSIONS: PULSED AF demonstrated a low rate of primary safety adverse events (0.7%) and provided effectiveness consistent with established ablation technologies using a novel irreversible electroporation energy to treat patients with AF. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04198701.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/drug therapy , Prospective Studies , Treatment Outcome , Anti-Arrhythmia Agents/therapeutic use , Electrocardiography , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
7.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38701222

ABSTRACT

AIMS: Pulsed field ablation (PFA) for the treatment of atrial fibrillation (AF) potentially offers improved safety and procedural efficiencies compared with thermal ablation. Opportunities remain to improve effective circumferential lesion delivery, safety, and workflow of first-generation PFA systems. In this study, we aim to evaluate the initial clinical experience with a balloon-in-basket, 3D integrated PFA system with a purpose-built form factor for pulmonary vein (PV) isolation. METHODS AND RESULTS: The VOLT CE Mark Study is a pre-market, prospective, multi-centre, single-arm study to evaluate the safety and effectiveness of the Volt™ PFA system for the treatment of paroxysmal (PAF) or persistent AF (PersAF). Feasibility sub-study subjects underwent phrenic nerve evaluation, endoscopy, chest computed tomography, and cerebral magnetic resonance imaging. Study endpoints were the rate of primary serious adverse event within 7 days and acute procedural effectiveness. A total of 32 subjects (age 61.6 ± 9.6 years, 65.6% male, 84.4% PAF) were enrolled and treated in the feasibility sub-study and completed a 30-day follow-up. Acute effectiveness was achieved in 99.2% (127/128) of treated PVs (96.9% of subjects, 31/32) with 23.8 ± 4.2 PFA applications/subject. Procedure, fluoroscopy, LA dwell, and transpired ablation times were 124.6 ± 28.1, 19.8 ± 8.9, 53.0 ± 21.0, and 48.0 ± 19.9 min, respectively. Systematic assessments of initial safety revealed no phrenic nerve injury, pulmonary vein stenosis, or oesophageal lesions causally related to the PFA system and three subjects with silent cerebral lesions (9.4%). There were no primary serious adverse events. CONCLUSION: The initial clinical use of the Volt PFA System demonstrates acute safety and effectiveness in the treatment of symptomatic, drug refractory AF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Feasibility Studies , Pulmonary Veins , Humans , Male , Female , Atrial Fibrillation/surgery , Atrial Fibrillation/therapy , Atrial Fibrillation/physiopathology , Middle Aged , Pulmonary Veins/surgery , Treatment Outcome , Prospective Studies , Catheter Ablation/methods , Catheter Ablation/instrumentation , Aged , Equipment Design , Phrenic Nerve/injuries , Time Factors
8.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38587017

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Latin America , Treatment Outcome , Catheters , Asia , Catheter Ablation/adverse effects , Catheter Ablation/methods
9.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38591838

ABSTRACT

AIMS: Recent trial data demonstrate beneficial effects of active rhythm management in patients with atrial fibrillation (AF) and support the concept that a low arrhythmia burden is associated with a low risk of AF-related complications. The aim of this document is to summarize the key outcomes of the 9th AFNET/EHRA Consensus Conference of the Atrial Fibrillation NETwork (AFNET) and the European Heart Rhythm Association (EHRA). METHODS AND RESULTS: Eighty-three international experts met in Münster for 2 days in September 2023. Key findings are as follows: (i) Active rhythm management should be part of the default initial treatment for all suitable patients with AF. (ii) Patients with device-detected AF have a low burden of AF and a low risk of stroke. Anticoagulation prevents some strokes and also increases major but non-lethal bleeding. (iii) More research is needed to improve stroke risk prediction in patients with AF, especially in those with a low AF burden. Biomolecules, genetics, and imaging can support this. (iv) The presence of AF should trigger systematic workup and comprehensive treatment of concomitant cardiovascular conditions. (v) Machine learning algorithms have been used to improve detection or likely development of AF. Cooperation between clinicians and data scientists is needed to leverage the potential of data science applications for patients with AF. CONCLUSIONS: Patients with AF and a low arrhythmia burden have a lower risk of stroke and other cardiovascular events than those with a high arrhythmia burden. Combining active rhythm control, anticoagulation, rate control, and therapy of concomitant cardiovascular conditions can improve the lives of patients with AF.


Subject(s)
Atrial Fibrillation , Stroke , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Stroke/etiology , Stroke/prevention & control , Risk , Hemorrhage , Anticoagulants/therapeutic use
10.
Intern Med J ; 54(4): 620-625, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37860995

ABSTRACT

BACKGROUND: Anticoagulation can prevent most strokes in individuals with atrial fibrillation (AF); however, many people presenting with stroke and known AF are not anticoagulated. Language barriers and poor health literacy have previously been associated with decreased patient medication adherence. The association between language barriers and initiation of anticoagulation therapy for AF is uncertain. AIMS: The aims of this study were to determine whether demographic factors, including non-English primary language, were (1) associated with not being initiated on anticoagulation for known AF prior to admission with stroke, and (2) associated with non-adherence to anticoagulation in the setting of known AF prior to admission with stroke. METHODS: A multicentre retrospective cohort study was conducted for consecutive individuals admitted to the three South Australian tertiary hospitals with stroke units over a 5-year period. RESULTS: There were 6829 individuals admitted with stroke. These cases included 5835 ischaemic stroke patients, 1333 of whom had pre-existing AF. Only 40.0% presenting with ischaemic stroke in the setting of known pre-existing AF were anticoagulated. When controlling for demographics, socioeconomic status and past medical history (including the components of the CHADS2VASC score and anticoagulation contraindications), having a primary language other than English was associated with a lower likelihood of having been commenced on anticoagulant for known pre-stroke AF (odds ratio: 0.52, 95% confidence interval: 0.36-0.77, P = 0.001), but was not associated with a differing likelihood of anticoagulation adherence. CONCLUSIONS: A significant proportion of patients with stroke have pre-existing unanticoagulated AF; these rates are substantially higher if the primary language is other than English. Targeted research and interventions to minimise evidence-treatment gaps in this cohort may significantly reduce stroke burden.

11.
Eur Heart J ; 44(27): 2447-2454, 2023 Jul 14.
Article in English | MEDLINE | ID: mdl-37062010

ABSTRACT

BACKGROUND: Catheter ablation is an effective strategy in atrial fibrillation (AF). However, its timing in the course of management remains unclear. The aim of this study was to determine if an early vs. delayed AF ablation strategy is associated with differences in arrhythmia outcomes during 12-month follow-up. METHODS AND RESULTS: One hundred patients with symptomatic AF referred to a tertiary centre for management were randomized in a 1:1 ratio to either an early ablation strategy (within 1 month of recruitment) or a delayed ablation strategy (optimized medical therapy followed by catheter ablation at 12 months post recruitment). The primary endpoint was atrial arrhythmia free survival at 12 months post-ablation. Secondary outcomes included: (i) AF burden, (ii) AF burden by AF phenotype, and (iii) antiarrhythmic drug (AAD) use at 12 months. Overall, 89 patients completed the study protocol (Early vs. Delayed: 48 vs. 41). Mean age was 59 ± 12.9 years (29% women). Pulmonary vein isolation was achieved in 100% of patients. At 12 months, 56.3% of patients in the early ablation group were free from recurrent arrhythmia, compared with 58.6% in the delayed ablation group (HR 1.12, 95% CI 0.59-2.13, P = 0.7). All secondary outcomes showed no significant difference including median AF burden (Early vs. Delayed: 0% [IQR 3.2] vs. 0% [5], P = 0.66), median AF burden amongst paroxysmal AF patients (0% [IQR 1.1] vs. 0% [4.5], P = 0.78), or persistent AF patients (0% [IQR 22.8] vs. 0% [5.6], P = 0.45) or AAD use (33% vs. 37%, P = 0.8). CONCLUSION: Compared with an early ablation strategy, delaying AF ablation by 12 months for AAD management did not result in reduced ablation efficacy.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Female , Male , Humans , Atrial Fibrillation/drug therapy , Treatment Outcome , Anti-Arrhythmia Agents/therapeutic use , Catheter Ablation/methods , Recurrence , Pulmonary Veins/surgery
12.
Eur Heart J ; 44(36): 3443-3452, 2023 09 21.
Article in English | MEDLINE | ID: mdl-37350480

ABSTRACT

AIMS: Lifestyle risk factors are a modifiable target in atrial fibrillation (AF) management. The relative contribution of individual lifestyle risk factors to AF development has not been described. Development and validation of an AF lifestyle risk score to identify individuals at risk of AF in the general population are the aims of the study. METHODS AND RESULTS: The UK Biobank (UKB) and Framingham Heart Study (FHS) are large prospective cohorts with outcomes measured >10 years. Incident AF was based on International Classification of Diseases version 10 coding. Prior AF was excluded. Cox proportional hazards regression identified independent AF predictors, which were evaluated in a multivariable model. A weighted score was developed in the UKB and externally validated in the FHS. Kaplan-Meier estimates ascertained the risk of AF development. Among 314 280 UKB participants, AF incidence was 5.7%, with median time to AF 7.6 years (interquartile range 4.5-10.2). Hypertension, age, body mass index, male sex, sleep apnoea, smoking, and alcohol were predictive variables (all P < 0.001); physical inactivity [hazard ratio (HR) 1.01, 95% confidence interval (CI) 0.96-1.05, P = 0.80] and diabetes (HR 1.03, 95% CI 0.97-1.09, P = 0·38) were not significant. The HARMS2-AF score had similar predictive performance [area under the curve (AUC) 0.782] to the unweighted model (AUC 0.802) in the UKB. External validation in the FHS (AF incidence 6.0% of 7171 participants) demonstrated an AUC of 0.757 (95% CI 0.735-0.779). A higher HARMS2-AF score (≥5 points) was associated with a heightened AF risk (score 5-9: HR 12.79; score 10-14: HR 38.70). The HARMS2-AF risk model outperformed the Framingham-AF (AUC 0.568) and ARIC (AUC 0.713) risk models (both P < 0.001) and was comparable to the CHARGE-AF risk score (AUC 0.754, P = 0.73). CONCLUSION: The HARMS2-AF score is a novel lifestyle risk score which may help identify individuals at risk of AF in the general community and assist population screening.


Subject(s)
Atrial Fibrillation , Humans , Male , Prospective Studies , Cohort Studies , Risk Factors , Longitudinal Studies , Risk Assessment , Incidence , Proportional Hazards Models
13.
Heart Lung Circ ; 2024 Sep 06.
Article in English | MEDLINE | ID: mdl-39244450

ABSTRACT

Atrial fibrillation (AF) is highly prevalent in the Australian community, ranking amongst the highest globally. The consequences of AF are significant. Stroke, dementia and heart failure risk are increased substantially, hospitalisations are amongst the highest for all cardiovascular causes, and Australians living with AF suffer from substantial symptoms that impact quality of life. Australian research has made a significant impact at the global level in advancing the care of patients living with AF. However, new strategies are required to reduce the growing incidence of AF and its associated healthcare demand. The Australian Cardiovascular Alliance (ACvA) has led the development of an arrhythmia clinical theme with the objective of tackling major research priorities to achieve a reduction in AF burden across Australia. In this summary, we highlight these research priorities with particular focus on the strengths of Australian research and the strategies needed to move forward in reducing incident AF and improving outcomes for those who live with this chronic condition.

14.
Circulation ; 146(9): e119-e136, 2022 08 30.
Article in English | MEDLINE | ID: mdl-35912643

ABSTRACT

Sleep-disordered breathing (SDB), characterized by specific underlying physiological mechanisms, comprises obstructive and central pathophysiology, affects nearly 1 billion individuals worldwide, and is associated with excessive cardiopulmonary morbidity. Strong evidence implicates SDB in cardiac arrhythmogenesis. Immediate consequences of SDB include autonomic nervous system fluctuations, recurrent hypoxia, alterations in carbon dioxide/acid-base status, disrupted sleep architecture, and accompanying increases in negative intrathoracic pressures directly affecting cardiac function. Day-night patterning and circadian biology of SDB-induced pathophysiological sequelae collectively influence the structural and electrophysiological cardiac substrate, thereby creating an ideal milieu for arrhythmogenic propensity. Cohort studies support strong associations of SDB and cardiac arrhythmia, with evidence that discrete respiratory events trigger atrial and ventricular arrhythmic events. Observational studies suggest that SDB treatment reduces atrial fibrillation recurrence after rhythm control interventions. However, high-level evidence from clinical trials that supports a role for SDB intervention on rhythm control is not available. The goals of this scientific statement are to increase knowledge and awareness of the existing science relating SDB to cardiac arrhythmias (atrial fibrillation, ventricular tachyarrhythmias, sudden cardiac death, and bradyarrhythmias), synthesizing data relevant for clinical practice and identifying current knowledge gaps, presenting best practice consensus statements, and prioritizing future scientific directions. Key opportunities identified that are specific to cardiac arrhythmia include optimizing SDB screening, characterizing SDB predictive metrics and underlying pathophysiology, elucidating sex-specific and background-related influences in SDB, assessing the role of mobile health innovations, and prioritizing the conduct of rigorous and adequately powered clinical trials.


Subject(s)
Atrial Fibrillation , Sleep Apnea Syndromes , Tachycardia, Ventricular , Adult , American Heart Association , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Autonomic Nervous System , Female , Humans , Male , Sleep Apnea Syndromes/complications , Sleep Apnea Syndromes/diagnosis , Sleep Apnea Syndromes/epidemiology , Tachycardia, Ventricular/complications
15.
Am J Physiol Heart Circ Physiol ; 325(4): H822-H836, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37505470

ABSTRACT

The left atrium (LA) plays a critical role in receiving pulmonary venous return and modulating left ventricular (LV) filling. With the onset of exercise, LA function contributes to the augmentation in stroke volume. Due to the growing focus on atrial imaging, there is now evidence that structural remodeling and dysfunction of the LA is associated with adverse outcomes including incident cardiovascular disease. In patients with established disease, pathological changes in atrial structure and function are associated with exercise intolerance, increased hospital admissions and mortality, independent of left ventricular function. Exercise training is widely recommended in patients with cardiovascular disease to improve patient outcomes and maintain functional capacity. There are widely documented changes in LV function with exercise, yet less attention has been given to the LA. In this review, we first describe LA physiology at rest and during exercise, before exploring its association with cardiac disease outcomes including atrial fibrillation, heart failure, and stroke. The adaptation of the LA to short- and longer-term exercise training is evaluated through review of longitudinal studies of exercise training in healthy participants free of cardiovascular disease and athletes. We then consider the changes in LA structure and function among patients with established disease, where adverse atrial remodeling may be implicated in the disease process. Finally, we consider important future directions for assessment of atrial structure and function using novel imaging modalities, in response to acute and chronic exercise.


Subject(s)
Atrial Fibrillation , Heart Failure , Humans , Heart Atria , Exercise , Ventricular Function, Left/physiology , Stroke Volume
16.
J Cardiovasc Electrophysiol ; 34(1): 142-146, 2023 01.
Article in English | MEDLINE | ID: mdl-36349715

ABSTRACT

OBJECTIVE: This study aimed to report the real-world atrial fibrillation (AF) diagnostic yield of the implantable cardiac monitor (ICM) in patients with stroke or transient ischemic attack (TIA), and compare it to patients with an ICM for unexplained syncope. METHODS: We used patient data from device clinics across the United States of America with ICM remote monitoring via PaceMate™, implanted for stroke or TIA, and unexplained syncope. Patients with known AF or atrial flutter were excluded. The outcome was AF lasting ≥2 min, adjudicated by International Board of Heart Rhythm Examiners certified cardiac device specialists. RESULTS: We included a total of 2469 patients, 51.1% with stroke or TIA (mean age: 69.7 [SD: 12.2] years, 41.1% female) and 48.9% with syncope (mean age: 67.0 [SD: 17.1] years, 59.4% female). The cumulative AF detection rate in patients with stroke or TIA was 5.5%, 8.9%, and 14.0% at 12, 24, and 36 months, respectively. The median episode duration was 73 (interquartile range: 10-456) min, ranging from 2 min to 40.9 days, with 52.3%, 28.6%, and 4.4% of episodes lasting at least 1, 6, and 24 h, respectively. AF detection was increased by age (adjusted hazard ratio [for every 1-year increase]: 1.024, 95% confidence interval: 1.008-1.040; p = .003), but was not influenced by sex (p = .089). For comparison, the cumulative detection rate at 12, 24, and 36 months were, respectively, 2.4%, 5.2%, and 7.4% in patients with syncope. CONCLUSION: Patients with stroke or TIA have a higher rate of AF detection. However, this real-world study shows significantly lower AF detection rates than what has been previously reported.


Subject(s)
Atrial Fibrillation , Ischemic Attack, Transient , Stroke , Humans , Female , Aged , Male , Atrial Fibrillation/diagnosis , Cohort Studies , Ischemic Attack, Transient/complications , Ischemic Attack, Transient/diagnosis , Electrocardiography, Ambulatory , Stroke/complications , Stroke/diagnosis , Syncope/diagnosis , Syncope/etiology
17.
J Cardiovasc Electrophysiol ; 34(2): 257-267, 2023 02.
Article in English | MEDLINE | ID: mdl-36378803

ABSTRACT

BACKGROUND: Implantable cardioverter defibrillators (ICD) are indicated for primary and secondary prevention of sudden cardiac arrest. Despite enhancements in design and technologies, the ICD lead is the most vulnerable component of the ICD system and failure of ICD leads remains a significant clinical problem. A novel, small-diameter, lumenless, catheter-delivered, defibrillator lead was developed with the aim to improve long-term reliability. METHODS AND RESULTS: The Lead Evaluation for Defibrillation and Reliability (LEADR) study is a multi-center, single-arm, Bayesian, adaptive design, pre-market interventional pivotal clinical study. Up to 60 study sites from around the world will participate in the study. Patients indicated for a de novo ICD will undergo defibrillation testing at implantation and clinical assessments at baseline, implant, pre-hospital discharge, 3 months, 6 months, and every 6 months thereafter until official study closure. Patients may be participating for a minimum of 18 months to approximately 3 years. Fracture-free survival will be evaluated using a Bayesian statistical method that incorporates both virtual patient data (combination of bench testing to failure with in-vivo use condition data) with clinical patients. The clinical subject sample size will be determined using decision rules for number of subject enrollments and follow-up time based upon the observed number of fractures at certain time points in the study. The adaptive study design will therefore result in a minimum of 500 and a maximum of 900 patients enrolled. CONCLUSION: The LEADR Clinical Study was designed to efficiently provide evidence for short- and long-term safety and efficacy of a novel lead design using Bayesian methods including a novel virtual patient approach.


Subject(s)
Defibrillators, Implantable , Heart Arrest , Humans , Bayes Theorem , Reproducibility of Results , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Treatment Outcome
18.
J Cardiovasc Electrophysiol ; 34(12): 2514-2526, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37787013

ABSTRACT

BACKGROUND: Obesity is associated with an increased risk of developing recurrent atrial fibrillation (AF) after catheter ablation (CA). However, the current data on weight loss interventions show inconsistent results in preventing the recurrence of AF after CA. METHODS: We conducted a systematic search in MEDLINE and EMBASE to identify studies that reported the outcome of recurrence of AF after CA in obese patients undergoing weight interventions. The subgroup analysis included: (1) Weight loss versus no weight loss, (2) >10% weight loss versus <10% weight loss, (3) <10% weight loss versus no weight loss, (4) Follow-up <12 months, and (5) Follow-up >12 months after CA. Mantel-Haenszel risk ratios with a 95% confidence interval (CI) were calculated using a random effects model and for heterogeneity, I2 statistics were reported. RESULTS: A total of 10 studies (one randomized controlled trial and nine observational studies) comprising 1851 patients were included. The recurrence of AF was numerically reduced in the weight loss group (34.5%) versus no weight loss group (58.2%), but no statistically significant difference was observed (risk ratio [RR] = 0.76; 95% CI: 0.49-1.18, p = .22). However, there was a statistically significant reduction in recurrence of AF with weight loss versus no weight loss at follow-up >12 months after CA (RR = 0.47; 95% CI: 0.32-0.68, p < .0001). At follow-up >12 months after CA, both >10% weight loss versus <10% weight loss (RR = 0.49; 95% CI: 0.31-0.80, p = .004) and <10% weight loss versus no weight loss (RR = 0.39; 95% CI: 0.31-0.49, p < .00001) were associated with a statistically significant reduction in recurrent AF. CONCLUSION: In patients with AF undergoing CA, weight loss is associated with reducing recurrent AF at > 12 months after ablation and these benefits are consistently seen with both >10% and <10% weight loss. The benefits of weight loss in preventing recurrent AF after CA should be examined in larger studies with extended follow-up duration.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Treatment Outcome , Recurrence , Obesity/complications , Obesity/diagnosis , Catheter Ablation/adverse effects , Catheter Ablation/methods , Randomized Controlled Trials as Topic
19.
J Cardiovasc Electrophysiol ; 34(2): 279-290, 2023 02.
Article in English | MEDLINE | ID: mdl-36352771

ABSTRACT

INTRODUCTION: Use of a novel magnetic sensor enabled optical contact force ablation catheter has been established to be safe and effective for treatment of symptomatic drug-refractory paroxysmal atrial fibrillation (AF) but has yet to be demonstrated in the persistent AF (PersAF) population. METHODS: PERSIST-END was a multicenter, prospective, nonrandomized, investigational study designed to demonstrate the safety and effectiveness of TactiCath™ Ablation Catheter, Sensor Enabled™(SE) (TactiCath SE) for use in the treatment of subjects with documented PersAF refractory or intolerant to at least one Class I/III AAD. The ablation strategy included pulmonary vein isolation and additional targets at physician discretion. Follow-up through 15-months, including a 3-month blanking period and 3-month therapy consolidation period, was performed with cardiac event and Holter monitoring. Primary safety, primary effectiveness, clinical success, and quality of life (QOL) endpoints were analyzed. RESULTS: Of 224 subjects enrolled at 21 investigational sites in the United States and Australia, 223 underwent ablation with the investigational catheter. The primary safety event rate was 3.1% (seven events in seven subjects). The Kaplan-Meier estimate of freedom from AF/atrial flutter/atrial tachycardia recurrence at 15-months was 61.6% and clinical success at 15 months was 89.8%. Subject QOL significantly improved following ablation as assessed via AFEQT (31.6 point increase, p < .0001) and EQ-5D-5L (10.7 point increase, p < .0001) and was met with a 53% reduction in all cause cardiovascular healthcare utilization. CONCLUSION: The sensor-enabled force-sensing catheter is safe and effective for the treatment of drug refractory recurrent symptomatic PersAF, reducing arrhythmia recurrence while improving QOL and healthcare utilization.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/drug therapy , Quality of Life , Prospective Studies , Heart Conduction System , Catheter Ablation/adverse effects , Catheter Ablation/methods , Pulmonary Veins/surgery , Treatment Outcome , Recurrence
20.
Eur J Neurol ; 30(7): 2042-2050, 2023 07.
Article in English | MEDLINE | ID: mdl-37038345

ABSTRACT

BACKGROUND AND PURPOSE: Whether carotid artery disease could improve stroke risk stratification tools in patients with atrial fibrillation (AF) remains uncertain. This study was undertaken to investigate the risk of ischemic stroke associated with occlusive and nonocclusive carotid atherosclerotic disease in patients with AF in the prospective population-based Cardiovascular Health Study. METHODS: We included participants aged ≥65 years with AF. We used multivariable Cox regression analysis to explore the risk of ischemic stroke associated with the percentage of carotid stenosis, plaque irregularity, echogenicity, and vulnerability (markedly irregular, ulcerated, or hypoechoic plaques). RESULTS: A total of 1398 participants were included (55.2% female, 61.7% aged 65-74 years). The maximum carotid stenosis was <50%, 50%-99%, and 100% in 94.5%, 5%, and 0.5% of participants, respectively. High-risk plaques based on echogenicity and plaque irregularity were found in 25.6% and 8.9% of participants, respectively. After a median follow-up of 10.9 years (interquartile range = 7.5-15.6), 298 ischemic strokes were recorded. There was no difference in the incidence of ischemic stroke according to the degree of carotid artery stenosis (p = 0.44), plaque echogenicity (low vs. high risk, p = 0.68), plaque irregularity (low vs. high risk, p = 0.55), and plaque vulnerability (p = 0.86). The CHA2DS2-VASc score was associated with an increased risk of ischemic stroke (adjusted hazard ratio = 1.28, 95% confidence interval = 1.18-1.40, p < 0.001). Both maximum grade of stenosis and plaque vulnerability were not associated with incident ischemic stroke (all p > 0.05). CONCLUSIONS: Neither the degree of carotid stenosis nor the presence of vulnerable plaques was associated with incident ischemic stroke in this cohort of individuals with AF. This suggests that carotid disease was probably not a significant contributor to ischemic stroke in this population.


Subject(s)
Atrial Fibrillation , Carotid Artery Diseases , Carotid Stenosis , Ischemic Stroke , Plaque, Atherosclerotic , Stroke , Humans , Female , Male , Stroke/etiology , Stroke/complications , Carotid Stenosis/complications , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/epidemiology , Ischemic Stroke/complications , Atrial Fibrillation/complications , Atrial Fibrillation/epidemiology , Prospective Studies , Risk Factors , Carotid Artery Diseases/complications , Plaque, Atherosclerotic/complications , Plaque, Atherosclerotic/diagnostic imaging , Plaque, Atherosclerotic/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL