ABSTRACT
Transcatheter aortic valve replacement (TAVR) often leads to conduction abnormalities, necessitating pacemaker implantation. This review of 38 meta-analyses identified preexisting right bundle branch block (RBBB), LAHB, and new-onset left bundle branch block as key risk factors, with a higher PPM risk in male and older patients. Procedural factors like transfemoral access and self-expandable valves also increase this risk. Prevention focuses on tailoring TAVR to individual electrophysiological and anatomical profiles. However, there's a lack of consensus in managing these conduction disturbances post-TAVR, highlighting the need for further research and standardized treatment strategies.
Subject(s)
Aortic Valve Stenosis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Male , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Aortic Valve Stenosis/surgery , Risk Factors , Pacemaker, Artificial/adverse effects , Bundle-Branch Block/diagnosis , Bundle-Branch Block/etiology , Bundle-Branch Block/prevention & control , Aortic Valve/surgeryABSTRACT
Background: Rates of major bleeding and intraprocedural thrombotic events (IPTE) in the setting of percutaneous coronary intervention (PCI) using weight-adjusted unfractionated heparin (UFH) without activated clotting time (ACT) monitoring are not known. Methods: We reviewed 2,748 consecutive patients who underwent coronary angiography at our tertiary care university hospital between January 2017 and December 2020. All patients who underwent PCI with weight-adjusted UFH without ACT guidance were considered for further analysis. Major bleeding complications occurring within 48 hours of PCI were collected from patients' medical records. IPTE were collected independently by two interventional cardiologists after review of coronary angiograms. Results: There were 718 patients included in the analysis (65.4 ± 12.2 years old; 81.3% male). In total, 45 patients (7.8%) experienced a major bleed or IPTE. The most common IPTE were slow/no reflow (1.5%) and coronary artery dissection with decreased flow (1.1%). Other IPTE occurred in <1% of cases. Major bleeding occurred in 11 patients (1.5%), of whom 8 required blood transfusion and 3 required vascular intervention. Bleeding complications were more common with femoral compared with radial access (6.6% vs. 0.2%, P < 0.001). Conclusion: Weight-adjusted UFH use during PCI without ACT monitoring was related to low rates of major bleeding or IPTE.
Subject(s)
Percutaneous Coronary Intervention , Thrombosis , Humans , Male , Middle Aged , Aged , Female , Heparin/adverse effects , Percutaneous Coronary Intervention/adverse effects , Treatment Outcome , Hemorrhage/chemically induced , Anticoagulants/adverse effectsABSTRACT
Atrial septal defect (ASD) is one of the most common congenital heart defects. Transcatheter device closure of ASDs is safe and effective with most of the reported data being described from developed countries. To evaluate the short and mid-term results and experience of device closure of ASDs at a tertiary center in a developing country and compare it to that from developed countries. Retrospective study based on data collection from all patients who have undergone transcatheter percutaneous device closure for ASD from January 2005 until December 2017 at the Children's Heart Center at the American University of Beirut, Medical Center, Lebanon. During the study period, a total of 254 cardiac catheterizations were performed for device closure of ASDs. The mean age of the patients was 18 ± 17.9 years with 37% being less than 6 years of age. Females were 54%. Defect size ranged from 7 to 37 mm and device size ranged from 8 to 40 mm. The procedure was executed with a success rate of 96%. Five patients had device embolization (2%); in one patient the device was snared and for the remainder the devices were removed surgically. None of the study patients had thrombus formation, neurological complications, bacterial endocarditis, or cardiac erosions. There was no mortality. Device closure of ASDs at our tertiary center in a developing country has an effective and safe profile with excellent results and low complications rates, which compare favorably to those reported from centers in developed countries.
Subject(s)
Cardiac Catheterization/methods , Heart Septal Defects, Atrial/surgery , Septal Occluder Device/statistics & numerical data , Adolescent , Adult , Aged , Cardiac Catheterization/adverse effects , Child , Child, Preschool , Developed Countries/statistics & numerical data , Developing Countries/statistics & numerical data , Female , Humans , Infant , Lebanon , Male , Middle Aged , Postoperative Complications/epidemiology , Retrospective Studies , Septal Occluder Device/adverse effects , Treatment Outcome , Young AdultABSTRACT
Transcatheter aortic valve replacement (TAVR) has become an established therapeutic option for patients with symptomatic, severe aortic stenosis. The optimal treatment strategy for concomitant coronary artery disease (CAD) has not been tested prospectively in a randomized clinical trial. This study aimed to describe the degree of CAD, revascularization strategies, and long-term clinical outcomes in a large-scale all-comers TAVR-population. Nine hundred and forty-four consecutive patients underwent TAVR. Obstructive CAD was reported in 224 patients (23.7%)-of these, 150 (66.9%) presented with one-vessel disease (1-VD), 51 (22.8%) with 2-VD, and 23 (10.3%) with 3-VD. Two-thirds underwent coronary revascularization before TAVR; half of those patients with 1-VD and only one-third of those with multivessel disease were completely revascularized. In general, borderline stenoses (50%-70%) were more frequently revascularized in proximal coronary segments than in more distal segments. Long-term survival rates by Kaplan-Meier analysis of the total TAVR population at 5 and 9 years were 64.7% and 54.1%, respectively. A diagnostic coronary angiography was performed in 16.5% of patients within 5 years after TAVR; only 4.8% underwent consequent percutaneous coronary intervention (PCI). There was no difference in survival and need for revascularization post-TAVR between those patients with or without obstructive CAD ± revascularization. Neither was there a survival difference between those with or without previous CABG and/or chronic total occlusion(s). In conclusion, CAD is prevalent in TAVR patients and pre-TAVR coronary revascularization is typically focused on treating proximal and high-grade stenosis. A selective pre-TAVR PCI strategy results in favorable clinical outcomes with very low rates of post-TAVR coronary revascularization.
Subject(s)
Aortic Valve Stenosis/surgery , Coronary Artery Disease/therapy , Coronary Stenosis/therapy , Myocardial Revascularization , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/mortality , Denmark/epidemiology , Female , Humans , Male , Myocardial Revascularization/adverse effects , Myocardial Revascularization/mortality , Prevalence , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment OutcomeABSTRACT
BACKGROUND: Whether the efficacy and safety of dual antiplatelet therapy (DAPT) are uniform between sexes is unclear. We sought to compare clinical outcomes between short- (≤6 months) versus long-term (≥1 year) DAPT after drug-eluting stent (DES) placement in women and men. METHODS AND RESULTS: We pooled individual patient data from 6 randomized trials of DAPT (EXCELLENT, OPTIMIZE, PRODIGY, RESET, SECURITY, ITALIC PLUS). The primary outcome was 1-year risk of major adverse cardiac events (MACE). The main secondary outcome was 1-year risk of any bleeding. Out of the 11,473 randomized patients included in the pooled dataset, 3,454 (30%) were females. At 1-year follow-up, women had higher risk of MACE (3.6% vs. 2.8%; P = 0.01) but similar risk of bleeding (1.9% vs. 1.6%; P = 0.16) as compared with men. Compared with long-term DAPT, short-term DAPT was associated with similar rates of MACE in both women (HR 0.88; 95% CI 0.62-1.25) and men (HR 1.25; 95% CI 0.95-1.6; P interaction = 0.08)]. At 1-year follow-up, short-term DAPT was associated with lower rates of bleeding as compared with long-term DAPT in both women (HR 0.84; 95% CI 0.51-1.37) and men (HR 0.58; 95% CI 0.40-0.84; P-interaction = 0.25). The presence of MVD was associated with higher MACE rates in the short-term DAPT group in women (HR: 1.16; CI 0.60-2.23) and men (HR: 2.29; CI 1.22-4.29; P interaction = 0.25). CONCLUSIONS: Short-term DAPT is associated with similar rates of MACE but lower risk of bleeding when as compared with prolonged DAPT. There was no significant difference between sexes in the population studied. © 2016 Wiley Periodicals, Inc.
Subject(s)
Drug-Eluting Stents , Percutaneous Coronary Intervention/instrumentation , Platelet Aggregation Inhibitors/administration & dosage , Aged , Coronary Thrombosis/etiology , Drug Administration Schedule , Female , Hemorrhage/chemically induced , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Multivariate Analysis , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Platelet Aggregation Inhibitors/adverse effects , Proportional Hazards Models , Randomized Controlled Trials as Topic , Risk Assessment , Risk Factors , Sex Factors , Time Factors , Treatment OutcomeABSTRACT
Transcatheter aortic valve implantation (TAVI) has become a well-established intervention with reproducible and excellent early and mid-term outcomes. A minimalist approach to TAVI is already the standard of care in many experienced centers. In this report, we share our experience and opinions on how we can further simplify the TAVI procedure in hope to establish the best possible outcomes.
Subject(s)
Aortic Valve Stenosis , Aortic Valve , Catheterization, Peripheral , Femoral Artery/surgery , Heart Valve Prosthesis , Postoperative Complications , Radial Artery/surgery , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Catheterization, Peripheral/methods , Female , France , Humans , Male , Patient Care Planning/standards , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Quality Improvement , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/methods , Treatment OutcomeABSTRACT
PURPOSE: To compare the procedure and safety outcomes of the transradial approach (TRA) with the femoral approach (FA) for treating aortoiliac and femoropopliteal stenoses and occlusions. METHODS: A single-center retrospective study was conducted involving 188 patients (mean age 66.4±10.8 years; 116 men) with lower limb claudication or critical limb ischemia who underwent aortoiliac (131, 62.4%) or femoropopliteal (79, 37.6%) interventions on 210 lesions over a 3-year period. Operator discretion determined TRA suitability; exclusions included Raynaud's disease, upper limb occlusive disease, previous TRA difficulties, or planned hemodialysis. Lesion characteristics, clinical endpoints, and access site complications were compared. RESULTS: FA was used primarily in 123 patients and the TRA (12 left and 53 right radial arteries) in 65 procedures. Eleven (16.9%) TRAs failed vs 9 (7.3%) FAs (p=0.42). Crossover to FA was due to occlusive lesions requiring alternative equipment in 9 cases and to tortuosity of the aortic arch vessels in 2 patients. The 134 FA interventions (balloon angioplasty, stents) were retrograde (112, 83.6%) or antegrade (22, 16.4%). There were significantly more TASC C/D lesions in the FA group (p=0.02). Sheath sizes (5-F to 8-F) did not differ between groups, and no significant differences were found between FA vs TRA in terms of procedure time (50.0±28.9 vs 46.8±25.1 minutes, p=0.50) or length of stay (2.2±0.6 vs 2.1±0.3 days, p=0.24). While there were no strokes, access site complications occurred in 6.0% of the FA patients vs 3.7% of the TRA patients (p=0.12). CONCLUSION: The transradial approach for aortoiliac and femoropopliteal interventions is safe and efficacious compared with the transfemoral approach for a range of lesion subtypes. Nevertheless, there remains a need for improvements in peripheral device and catheter technology to decrease transradial failure rates.
Subject(s)
Angioplasty, Balloon , Constriction, Pathologic/surgery , Popliteal Artery/surgery , Stents , Aged , Femoral Artery/surgery , Humans , Male , Middle Aged , Retrospective Studies , Treatment OutcomeABSTRACT
We describe a unique report of percutaneous closure of multiple secundum atrial septal defects in a child utilizing three Occlutech Figulla septal occluders deployed sequentially. The procedure was performed under live three-dimensional transesophageal echocardiography guidance.
ABSTRACT
Transcatheter tricuspid valve intervention (TTVI) has emerged as a promising alternative for patients with severe tricuspid regurgitation who are deemed high-risk for surgery. With advancements in device design and delivery systems, TTVI has shown promising outcomes in reducing tricuspid regurgitation severity and improving symptoms in selected patients. Paravalvular leaks (PVLs) are one of the most common complications faced, which can significantly contribute to patients' morbidity and mortality. Percutaneous PVL closure represents a minimally invasive approach to address this issue, but its efficacy and safety in the context of transcatheter tricuspid valve-in-ring implantation require further elucidation. We describe the case of a 44-year-old lady with a history of rheumatic valve disease status post-tricuspid valve annuloplasty with an incomplete ring who presented to cardiology clinics with symptomatic torrential tricuspid regurgitation. Due to the high risk of surgical reintervention secondary to severe right ventricular (RV) failure, she was denied surgical intervention. Therefore, she underwent transcatheter tricuspid valve-in-ring (TVIR) implantation with a 26 mm MyVal (Meril Life Sciences Pvt Ltd., Vapi, GJ, IND), which was complicated by a residual severe tricuspid paravalvular regurgitation. The defect was subsequently closed by a dedicated Occlutech PVL device (Occlutech, Helsingborg, SWE) measuring 18 mm x 10 mm. Post which, the patient had trivial tricuspid regurgitation and significant improvement in signs and symptoms with subsequent follow-up.
ABSTRACT
Introduction: In pulmonary embolism (PE), when used for catheter-directed thrombolysis (CDT), low-dose alteplase is associated with good outcomes. Tenecteplase has been only used as intravenous for this indication. In the context of our national economic crisis where alteplase was unavailable, we describe our experience with tenecteplase CDT. Case: A 73-year-old male, hypertensive and smoker with COPD, presented to the ED with intermediate high-risk PE.(ED) with intermediate high-risk PE. Heparin infusion was initiated. A few hours later, the patient developed atrial fibrillation (AF) for which amiodarone infusion was started. Also, a left femoral and popliteal vein thrombosis was also confirmed by the lower extremity duplex. As the patient remained dyspneic with unstable vital signs, the decision was to perform a CDT. In the absence of alteplase, tenecteplase was used at 0.5 mg/h over 30 h, for a total of 15 mg. Result: Twenty-four hours after tenecteplase initiation, dyspnea and vital signs had significantly improved. Oxygen support was gradually dropping to finally stop. Being on concomitant heparin infusion, the patient had a mild blood oozing at the femoral vein site of entry; however, this did not require any transfusion or discontinuation of heparin. The patient regained his baseline physical and mental functions and was discharged on enoxaparin and amiodarone tablet. Discussion: This is the first experience describing the use of tenecteplase as part of CDT in a patient with acute intermediate high-risk PE. The combination to therapeutic heparin infusion, already described in different clinical scenarios with intravenous tenecteplase, was safe and well tolerated Conclusion: CDT with tenecteplase was, for the first time, safely and effectively used in an intermediate high-risk PE patient. However, more studies are needed to confirm and establish these findings.
ABSTRACT
INTRODUCTION: Transcatheter aortic valve replacement (TAVR) is an effective alternative to surgical aortic valve replacement (SAVR) in patients with severe aortic stenosis in all surgical risk groups. Reports of clinical outcomes post-TAVR in developing countries are scarce. We aimed to address the clinical outcomes and safety profile of TAVR in a developing country. METHODS: We conducted a single-center, retrospective study on patients undergoing TAVR at the American University of Beirut Medical Center (AUBMC) from January 2016 to April 2023. We included a total of 399 patients. Our primary endpoint was to assess the rate of TAVR in-hospital and 30-day mortality, neurologic events, and new permanent pacemaker implantation (PPI) in patients, stratified by the Society of Thoracic Surgeons (STS) risk of mortality score. RESULTS: Survival rates were 98.7% (394) at discharge vs. 97.5% (389) at 30 days post-procedure. The technical success rate was 95% (379) at the end of the procedure. Device success and early safety rates were 93.5% (373) and 83% (331), respectively at 30 days post-procedure. The all-cause mortality rate increased from 1.3% (5) at discharge to 2.5% (10) at 30-day intervals. The rate of ischemic stroke was 1.3% (five) at discharge and increased to 2% (eight) at 30 days post-procedure. PPI was needed in 5.8% (23) of patients at discharge with an increase to 7% (28) at one-month interval. Overall, the rates of TAVR outcomes among the three risk groups were comparable including neurologic events, valve-related complications, bleeding problems, vascular and access-related complications, and myocardial infarction. CONCLUSION: This study at AUBMC highlights the successful implementation of the TAVR program in a developing country, showcasing its efficacy and safety within 30 days post-operation, despite challenges such as financial constraints and limited access to specialized training. Larger cohorts and longer follow-up periods are needed to accurately represent clinical outcomes in developing countries.
ABSTRACT
BACKGROUND: Left atrial appendage (LAA) closure is an alternative to chronic anticoagulation for stroke prevention in patients with nonvalvular atrial fibrillation. Multiple devices were used for LAA closure, with the Amplatzer Amulet LAA Occluder (Abbott, Chicago, IL, USA) and Watchman device (Boston Scientific, Marlborough, MA, USA) being the most commonly used in clinical practice. In August 2021, the FDA approved the use of the Amplatzer Amulet LAA Occluder. There is still a knowledge gap in the safety profile of the Amplatzer Amulet LAA Occluder device in comparison to the Watchman device. OBJECTIVE: The aim of this study was to assess and compare the safety profile peri-procedure and post-procedure between the Amplatzer Amulet LAA Occluder and Watchman devices. METHODS: Patients who underwent LAA closure using Watchman or Amulet devices from July 2015 to August 2020 at the American University of Beirut Medical Center were included in the analysis. Primary endpoints included peri-operative and post-procedural complications (thromboembolic events, bleeding complications, vascular access complications, pericardial effusion/tamponade, device positional complications and in-hospital death). RESULTS: The study included 37 patients (21 had Watchman devices, 16 had Amplatzer Amulet LAA Occluder devices, and 28 were men, mean age 76.57 ± 9.3 years). Seven patients developed post-procedural iatrogenic atrial septal defects (four in the Watchman group vs three in the Amulet group, p-value=0.982). Three patients developed pericardial effusion (one in the Watchman vs two in the Amulet group, p-value=0.394). Only one patient developed peri-device leak (one in the Watchman group vs none in the Amulet group, p-value=0.283). One device could not be deployed (one in the Amulet group vs none in the Watchman group, p-value=0.191). None of the patients developed in-hospital death, cardiac tamponade, device embolism, device thrombosis, stroke/transient ischemic attack (TIA), cranial bleeding, or arrhythmias after the procedure. The rate of peri-operative complications was similar between both groups. Both groups displayed low rates of adverse events in the peri-operative and post-operative periods. CONCLUSION: There was no significant difference in the safety profile of Amplatzer Amulet LAA Occluders and Watchman devices. There was a low incidence of peri-operative and post-operative adverse events with the implanted devices.
ABSTRACT
We describe a case of valve thrombosis and a subsequent thromboembolic event within only 10 days of transcatheter aortic valve implantation (TAVI). Postprocedural anticoagulants are not standard of care medications post-TAVI in patients without atrial fibrillation. Valve thrombosis is an indication to initiate anticoagulation to resolve and prevent further thrombus.
ABSTRACT
Transcatheter aortic valve replacement (TAVR) is indicated for the treatment of patients with severe aortic stenosis (AS) at low, intermediate, and high risk. Immediate complications post-TAVR that lead to hemodynamic compromise include: retroperitoneal bleeding, aortic dissection or rupture, pericardial tamponade, coronary ostial obstruction, acute severe central or paravalvular regurgitation, heart block, and suicide left ventricle. The presence of significant paravalvular leak (PVL) after TAVR is now an uncommon complication with newer generation devices. We present a case of an 82-year-old frail female patient who presented to our clinic with dyspnea upon minimal exertion and orthopnea. She was found to have severe AS that was treated with TAVR. The procedure was complicated by hemodynamic compromise due to severe PVL and left ventricular outflow tract (LVOT) obstruction which was underestimated by transthoracic echocardiography. The PVL was eventually treated with a vascular plug device and the LVOT obstruction was treated with alcohol septal ablation. This case highlights the vital role of early and aggressive work up in unstable patients post-TAVR and the importance of transesophageal echocardiography in patients with unexplained hypotension post-TAVR to unmask the severe PVL and dynamic LVOT obstruction.
ABSTRACT
RATIONALE AND OBJECTIVES: Aortic stenosis (AS) is one of the most common valvular heart disease. Symptomatic AS is associated with a high mortality rate which prompts fast intervention. The introduction of transcatheter aortic valve replacement (TAVR) has drastically improved the outcome of high surgical risk for mortality patients with severe AS. However, this procedure requires the employment of multimodality imaging in the pre-procedural planning, intra-procedural optimization, and post-procedural follow-up stages. This also requires an accurate understanding of the indications, measurements, strength, and limitations of each imaging modality during the different TAVR stages. CONCLUSION: In this review, we aim to outline to radiologists the evidence-based approach and indications of different imaging modalities through the pre, peri, and post TAVR stages.
Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Multimodal Imaging , Radiologists , Treatment OutcomeABSTRACT
Right-to-left shunt due to abnormal systemic venous drainage to the left heart is among the causes of hypoxemia following Fontan operation. There are conflicting data regarding the closure of the venovenous collaterals (VVCs) post-Fontan, showing decreased survival in older patients. In a child with visceral heterotaxy, we describe a rare fistula draining a right-sided hepatic vein into hepatic venous plexus and a right-sided pulmonary venous atrium. The patient presented with severe hypoxemia post-Fontan and underwent fistula occlusion with AMPLATZER™ Vascular Plug II, successfully improving hemodynamic status with resolution of the hypoxemia. Younger patients with cyanosis due to VVCs may benefit from percutaneous occlusion post-Fontan.
ABSTRACT
OBJECTIVES: The goal of this study was to assess the performance and incidence of the deterioration of the Labcor Dokimos bioprosthetic aortic valve. METHODS: We performed a retrospective medical chart review of 116 patients who underwent surgical aortic valve replacement with the Labcor Dokimos aortic valve between 2010 and 2018. Abstracted data included patient demographic and echocardiographic data. Patients were divided into 2 groups: patients with structural valve deterioration (SVD) and patients without SVD. RESULTS: Among the patients with complete follow-up (n = 95), 10 patients were excluded because they died within a year; 85 patients were included in the final analysis. Of the 85 patients, 32 (38%) developed SVD; 22 (26%) had severe SVD, 15 (18%) of whom underwent reintervention. The most common aetiology of SVD was severe central aortic regurgitation, which was detected in 91% of the patients who had severe SVD. The average time from operation to severe SVD was 4.7 years with a minimum of 1.5 years and a maximum of 7.9 years. CONCLUSIONS: Bioprosthetic aortic valve deterioration due to severe aortic regurgitation is common and occurs early with the Labcor Dokimos valve. This occurrence needs to be furthered investigated in larger registries.
Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/adverse effects , Humans , Prosthesis Design , Prosthesis Failure , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment OutcomeABSTRACT
BACKGROUND/PURPOSE: CoA remains one of the most common congenital heart diseases and is associated with significant morbidity and mortality and if untreated. We aim to evaluate the safety, feasibility, and outcomes of endovascular stenting of Coarctation of the aorta (CoA) in a developing country with limited resources and compare it to available benchmarks. MATERIALS/METHODS: A retrospectively review of all patients who underwent endovascular stent repair of aortic coarctation at our tertiary center since 2009 was done. RESULTS: 18 patients were identified, sixteen had native CoA, while two had recurrent CoA. mean age at the time of procedure was 21.2 ± 9.8 years (range 10-45 years), and 12(66%) patients were males. The mean follow-up duration was 4 ± 2.8 years. Post stenting, the average ascending-to-descending aorta systolic gradient decreased by 42.9 ± 20.4 mmHg (p < 0.001). After the intervention, 13(72.2%) patients achieved normal BP while 5(27.8%) had residual hypertension. Fourteen patients received bare-metal stents, and four had covered stents. Attempted stent implantation was successful in all patients. Our procedural success rate was 94%. On follow-up, no dissections or aneurysmal changes were detected, four patients underwent re-expansion of the stent, one patient with suboptimal stenting result required surgery 6 months after stenting, and two patients had minor post-operative complications. CONCLUSIONS: Endovascular stenting for de-novo or recurrent CoA in children and adults at a tertiary center in a developing country is feasible and safe with outcomes comparable to developed countries. A multidisciplinary team approach is paramount in achieving good results and low complication rates in limited-resource settings.