Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
Add more filters

Country/Region as subject
Publication year range
1.
J Acquir Immune Defic Syndr (1988) ; 6(7): 823-30, 1993 Jul.
Article in English | MEDLINE | ID: mdl-8509982

ABSTRACT

Percentages and absolute counts of CD4+ lymphocytes, as determined by T-lymphocyte immunophenotyping (TLI), are prognostic, as well as diagnostic, of the course of human immunodeficiency virus type 1 infections and are important indicators for initiating Pneumocystis carinii pneumonia prophylaxis and antiretroviral therapy. In December 1990, we requested that a nonrandom sample of 17 laboratories provide us with typical reports of their TLI results from an immunodeficient patient and from a patient whose TLI results were within the laboratory's normal reference ranges. We also searched published literature and documents proposed by professional organizations for recommendations regarding T-lymphocyte testing and reporting. This article compares guidelines for reporting TLI results, as proposed by the National Committee for Clinical Laboratory Standards in Document H42-P, with samples of reports obtained in our case series. Most reports follow some, but not all, of the proposed guidelines. A majority of the laboratories provided interpretations of the results in their reports. We found considerable variation in normal reference ranges. We describe this variation in detail for the CD4+ T-lymphocyte counts and CD4+ T-lymphocyte percentages. This article describes some of the TLI result report forms currently being used and identifies important quality issues in this rapidly expanding area of clinical laboratory testing.


Subject(s)
Immunophenotyping/standards , Medical Records/standards , T-Lymphocyte Subsets , Forms and Records Control , Humans , Leukocyte Count , Reference Values , T-Lymphocyte Subsets/cytology , Terminology as Topic
2.
Public Health Rep ; 105(2): 167-71, 1990.
Article in English | MEDLINE | ID: mdl-2157234

ABSTRACT

In 1986, the Centers for Disease Control (CDC) implemented the Model Performance Evaluation Program (MPEP) to evaluate the performance of laboratories that test for antibody directed against human immunodeficiency virus type 1 (HIV-1). The impetus for developing this program came from the recognition of a need to assess the quality of existing and changing laboratory technology and to ensure that the quality of testing was sufficient to meet medical and public health needs. To develop the program, CDC chose HIV-1 antibody testing as the first specific application for assessing the quality of laboratory performance because (a) of the importance of accurate and reproducible test results for acquired immunodeficiency syndrome (AIDS) surveillance, prevention, and treatment programs; (b) HIV-1 testing technology is new to many laboratories; and (c) HIV-1 testing practices and applications continue to evolve. Unlike proficiency testing programs, the MPEP is not limited to assessing quality in the analytical step, alone. It will also assess quality in the preanalytical and postanalytical steps of the testing process, that is, from the time a test is requested until the clinician who ordered the test takes an action based on the test result. The participating laboratories furnish the information needed for the performance evaluation program by (a) completing questionnaires designed to describe HIV-1 testing laboratories and their testing practices, (b) analyzing specially prepared sample panels for HIV-1 antibody reactivity, and (c) reporting results to CDC.


Subject(s)
AIDS Serodiagnosis/standards , Laboratories/standards , Program Evaluation/standards , AIDS Serodiagnosis/methods , Centers for Disease Control and Prevention, U.S. , Confidentiality , HIV Seroprevalence , Humans , Quality Control , Reference Values , Surveys and Questionnaires , United States/epidemiology
3.
Arch Pathol Lab Med ; 116(5): 471-6, 1992 May.
Article in English | MEDLINE | ID: mdl-1316110

ABSTRACT

In three performance evaluation surveys, panels that consisted of human T-lymphotropic virus type I or type II (HTLV-I/II) antibody-positive and -negative plasma samples were mailed to laboratories that voluntarily participated in the Centers for Disease Control Model Performance Evaluation Program. Donor samples were identical among surveys. In each survey, more than 98% of the laboratories reported enzyme immunoassay (EIA) test results; about 11% also reported results of Western blot (WB) testing. Variation in analytic sensitivity (96.7% to 99.4%) and specificity (98.3% to 99.5%) of EIA tests was noted in the three surveys. For WB testing, no nonreactive interpretations were reported for HTLV-I/II antibody-positive samples in any survey; however, indeterminate interpretations were reported for 35.2% to 40.7% of the WB tests that were performed on HTLV-I/II antibody-positive samples. More than 95% of these indeterminate WB test interpretations were reported for HTLV-II antibody-positive samples. Although HTLV-I/II antibody tests are generally sensitive and specific, their accuracy could be further improved by increasing the specificity of EIA tests and the sensitivity of WB tests.


Subject(s)
Blotting, Western/trends , Human T-lymphotropic virus 1/isolation & purification , Human T-lymphotropic virus 2/isolation & purification , Immunoenzyme Techniques , Blotting, Western/standards , Centers for Disease Control and Prevention, U.S. , Evaluation Studies as Topic , Humans , Immunoenzyme Techniques/standards , Quality Assurance, Health Care , Sensitivity and Specificity , United States
4.
Arch Pathol Lab Med ; 125(12): 1546-54, 2001 Dec.
Article in English | MEDLINE | ID: mdl-11735688

ABSTRACT

CONTEXT: Human immunodeficiency virus (HIV) RNA testing (viral load testing) is increasingly important in the care of patients infected with HIV-1 to determine when to initiate, monitor, and change antiretroviral therapy. Patient viral load testing information is communicated to the clinician through the laboratory test report. OBJECTIVES: To examine the format and information used in reporting viral load testing results and determine the clarity of the information provided in these reports. DESIGN: Patient test reports with all personal identifiers removed were requested of viral load testing laboratories participating in a telephone survey of laboratory practices. Hospital, independent, health department, and "other type" laboratories identified as university-associated laboratories participated in the telephone survey. RESULTS: Thirty-seven unique test reports were collected. All laboratories reported results in copies/mL, while 14% also reported results as "log(10) copies/mL." The test kit was identified by only 24% of the laboratories. Reportable ranges were specified by 70% of the laboratories, but there was considerable variation in terminology. One laboratory reported a viral load copy number below the manufacturer's test kit lower limit of sensitivity. The layout and format differed among reports. Some results were expressed in log(10), others contained nonsignificant integers, while others contained exponential numbers. Supplemental information in some reports included previous patient test results and significance of changes from baseline. The format of some reports made it difficult to read the report information and interpret the testing results. CONCLUSION: This study emphasizes the importance of standardizing the reporting of HIV-1 viral load test results to minimize result misinterpretation and incorrect treatment.


Subject(s)
Disease Notification/methods , HIV Infections/virology , HIV-1/isolation & purification , Laboratories/standards , Viral Load/methods , Data Collection , HIV Infections/diagnosis , Humans , Quality Control , RNA, Viral/analysis , Reagent Kits, Diagnostic , Reproducibility of Results , United States
5.
Arch Pathol Lab Med ; 114(3): 263-7, 1990 Mar.
Article in English | MEDLINE | ID: mdl-2154961

ABSTRACT

Ensuring high quality in human immunodeficiency virus type 1 (HIV-1) antibody testing is an essential component of the organized public health response to epidemic HIV-1 infection. In 1986, the Centers for Disease Control designed the Model Performance Evaluation Program to assess and improve the analytic quality of HIV-1 antibody testing. In addition, the program was designed to gather information about HIV-1 antibody testing practices. The utility of this information is in identifying potential barriers to quality throughout the total testing process. Currently, 1405 laboratories participate in the program. Participating laboratories are located both within and outside the United States and consist primarily of hospitals, blood banks, health departments, and independent laboratories. The responses to a questionnaire completed by 1050 program-participant laboratories in September 1988 suggest that at several stages in the HIV-1 antibody total testing process, laboratory practices (including the interpretation of Western blot patterns) are variable and that standardization of these practices would improve quality.


Subject(s)
HIV Antibodies/analysis , HIV Infections/diagnosis , HIV-1/immunology , Program Evaluation , Quality Assurance, Health Care , Centers for Disease Control and Prevention, U.S. , Data Collection , Humans , Quality Control , United States
6.
Arch Pathol Lab Med ; 117(11): 1148-55, 1993 Nov.
Article in English | MEDLINE | ID: mdl-8239938

ABSTRACT

To identify factors that may affect the quality of laboratory performance of human immunodeficiency virus type 1 (HIV-1) antibody testing, the Centers for Disease Control and Prevention Model Performance Evaluation Program surveyed laboratories in 1989 that performed enzyme immunoassay (EIA) and Western blot tests for HIV-1 antibody. Panels of 10 HIV-1-antibody-positive and antibody-negative plasma samples, some of which were duplicates, were mailed to program-participating laboratories. Laboratories were also mailed survey questionnaires to ascertain their laboratory characteristics and testing practices. Using 1988 data, researchers previously found that the overall analytic performance of laboratories performing HIV-1 antibody testing was independently associated with the following: (1) requiring a minimum degree of testing personnel; (2) having written criteria for identifying unsatisfactory specimens; (3) requiring in-house training for testing personnel; (4) having tested more than 10,000 specimens; (5) being identified as an "other" laboratory type; (6) having more than 24 months of testing experience; (7) laboratory uses specific (Abbott) materials for EIA; and (8) testing specimens collected by family-planning clinics. To verify these findings, we performed multivariate analysis on 1989 performance data. For the 1989 EIA analytic sensitivity, significant positive (P < or = .05) associations were detected with having written criteria for identifying unsatisfactory specimens and with having tested more than 10,000 specimens. For the 1989 overall EIA analytic performance, a significant negative (P < or = .05) association was found with using specific (Abbott) EIA materials, and a significant positive (P < or = .05) association was found with having tested more than 10,000 specimens. For Western blot results, the only significant (P < or = .05) associations were for both analytic sensitivity and overall analytic performance and having tested more than 10,000 specimens.


Subject(s)
HIV Antibodies/analysis , HIV-1/immunology , Quality Assurance, Health Care , Blotting, Western , False Positive Reactions , Humans , Immunoenzyme Techniques , Multivariate Analysis
7.
Arch Pathol Lab Med ; 122(8): 700-7, 1998 Aug.
Article in English | MEDLINE | ID: mdl-9701331

ABSTRACT

OBJECTIVE: To assess use of quality control (QC) material, supplemental to internal kit controls (calibrators), as protection against errors in enzyme immunoassay testing for human immunodeficiency virus type 1 antibodies. DESIGN: From August 1994 to January 1996, enzyme immunoassay testing accuracy was assessed for laboratories participating in the Centers for Disease Control and Prevention Model Performance Evaluation Program that provided information regarding their use of QC material. Error rates were examined for human immunodeficiency virus type 1 antibody-negative, strongly positive, and weakly positive samples. RESULTS: The overall error rate with QC (2.20%) was significantly (P = .0023) lower than the error rate without QC (2.90%). With QC use there was a significant reduction in the relative risk of error for negative (P = .014) and weakly positive (P = .0067) samples. After multivariate analysis, use of QC lowered overall error rate by 29% (P = .0009). Laboratories not using QC were at increased risk of systematic error. Following the Clinical Laboratory Improvement Amendments of 1988 guidelines for QC material was relatively more protective against error than lower frequencies/number of levels. CONCLUSIONS: Using QC protected against errors in enzyme immunoassay testing for human immunodeficiency virus type 1 antibodies. Two levels of QC should be used with each run as mandated by the Clinical Laboratory Improvement Amendments of 1988.


Subject(s)
HIV Antibodies/analysis , HIV-1/immunology , Immunoenzyme Techniques/standards , Reagent Kits, Diagnostic/standards , Clinical Laboratory Techniques/standards , Humans , Laboratories/classification , Laboratories/standards , Multivariate Analysis , Quality Control , Sensitivity and Specificity
8.
Arch Pathol Lab Med ; 116(5): 477-81, 1992 May.
Article in English | MEDLINE | ID: mdl-1580749

ABSTRACT

In 1986, a performance evaluation program at the Centers for Disease Control was implemented to assess the quality of performance of laboratories testing for human immunodeficiency virus type 1 antibody and to identify problems that occur during the testing process. Laboratories participating in the Centers for Disease Control Model Performance Evaluation Program for human immunodeficiency virus type 1 antibody testing furnished enzyme immunoassay results after they tested performance evaluation panels that were sent to them in August and November 1989. The panels consisted of 10 individual samples containing antibody-negative and antibody-positive samples, some of which were duplicates. Not all laboratories received the same panel of samples. Low false-negative and false-positive rates, as well as high intrashipment and intershipment reproducibility, indicate that most laboratories did not experience difficulty in testing performance evaluation samples sent to them in August and November 1989.


Subject(s)
HIV Antibodies/analysis , HIV-1/immunology , Immunoenzyme Techniques/standards , Laboratories/standards , Evaluation Studies as Topic , HIV Infections/diagnosis , Humans , Quality Assurance, Health Care , Reagent Kits, Diagnostic , Reproducibility of Results , Sensitivity and Specificity , Surveys and Questionnaires
9.
Clin Lab Sci ; 12(5): 278-89, 1999.
Article in English | MEDLINE | ID: mdl-10623327

ABSTRACT

OBJECTIVE: To develop and evaluate methods and results for blind proficiency testing for CD4+ T-cells by T-lymphocyte immunophenotyping. DESIGN: A model system was developed to submit duplicate specimens for T-lymphocyte immunophenotyping as if they were routine patient specimens rather than proficiency specimens. Testing results were compared both interlaboratory and intralaboratory. The model system was designed to gather information on not just the analysis, but other segments of the total testing process. SETTING: Research facilities at the Graduate School of Public Health, San Diego State University, San Diego CA. PARTICIPANTS: 1) A healthy adult volunteer donating one pint of blood. 2) Laboratories offering T-lymphocyte immunophenotyping. MAIN OUTCOME MEASURES: 1) Feasibility of blind proficiency so that PT specimens are received, analyzed, and reported by laboratories without being identified as 'proficiency specimens.' 2) The ease and cost of such a system. 3) The comparability of results and report content among laboratories. RESULTS: A total of twenty-two laboratories received blind proficiency specimens. The model developed to submit specimens and receive results proved feasible. The interlaboratory coefficient of variation for CD4+ count for the four survey years ranged from 10% to 66% and for the CD4+ percent ranged from 4% to 15%. The per specimen cost in this blind proficiency testing was $437.65, approximately seven and a half times the cost for nonblinded proficiency testing or performance evaluations. CONCLUSIONS: Blind proficiency as a tool to compare laboratory test results for T-lymphocyte immunophenotyping is feasible but adds costs. The model system is useful to examine more of the laboratory total testing process than the analysis segment.


Subject(s)
CD4-Positive T-Lymphocytes/classification , Immunophenotyping , Blood Specimen Collection , CD4-Positive T-Lymphocytes/immunology , Humans
10.
Clin Lab Sci ; 5(3): 165-71, 1992.
Article in English | MEDLINE | ID: mdl-10147724

ABSTRACT

The use of blind proficiency testing (PT) to examine analytic performance of human immunodeficiency virus type 1 (HIV-1) antibody testing. A total of 32 hospital, blood bank, public health, and commercial laboratories were included in this study. Test sera were introduced as clinical specimens for HIV-1 testing from private practitioners, group practices, clinics, and hospitals in Southern California. A total of 26 laboratories were located throughout California, with six laboratories located in six other states. Results from 306 enzyme immunoassay screening tests and 192 supplemental tests for HIV-1 were reported. Although one positive specimen was reported as indeterminate in almost 30% of results, screening and supplemental testing performances were excellent, with accuracy levels comparable to performance reported on open PT and performance evaluation surveys in the United States. The indeterminate results were attributed to the interpretive criteria used rather than to laboratory errors. Blind PT can be an important tool in improving the quality of total laboratory testing, the usefulness of laboratory results in patient care, and ultimately the health of the public.


Subject(s)
AIDS Serodiagnosis/standards , Blotting, Western , Evaluation Studies as Topic , HIV Antibodies/analysis , Humans , Immunoenzyme Techniques , Laboratories/standards , Quality Control , Sensitivity and Specificity , Single-Blind Method , United States
11.
Clin Lab Sci ; 5(3): 172-6, 1992.
Article in English | MEDLINE | ID: mdl-10147725

ABSTRACT

Blind proficiency testing was used to examine nonanalytic performance indicators for human immunodeficiency virus type 1 (HIV-1) antibody testing. Physician offices, clinics, and hospitals located throughout Southern California submitted simulated patient specimens to laboratories as routine test requests. A total of 32 laboratories were involved during five blind proficiency testing surveys. Turnaround time for a reactive specimen ranged from three to 17 days. Laboratory charges for evaluating a reactive specimen varied depending on the volume of testing, prevalence of reactive specimens, and whether screening and confirmatory tests were billed separately or as a package price. Charges for an enzyme immunoassay screening test plus supplemental tests ranged from $11.75 to $114.50, with a median of $31.00 for 24 laboratories that participated in one of the five surveys. Evaluation of laboratory report content revealed that 37% of the 16 screening reports and 71% of the 14 supplemental reports contained information that was unrelated to the patient results. Evaluation of the testing system documents the need to monitor multiple outcomes of the total laboratory testing process, not just the analytic testing phase.


Subject(s)
AIDS Serodiagnosis/standards , AIDS Serodiagnosis/economics , Evaluation Studies as Topic , Fees and Charges , HIV Antibodies/analysis , Humans , Immunoenzyme Techniques , Quality Control , Single-Blind Method , Time Factors
12.
MLO Med Lab Obs ; 29(12): 40-2, 1997 Dec.
Article in English | MEDLINE | ID: mdl-10175643

ABSTRACT

The Pan American Health Organization (PAHO) supports performance evaluation programs in clinical chemistry, Caribbean. Much more work remains to be done before many labs in this part of the world can be certified as providing accurate results, but PAHO has taken an important first step toward establishing benchmarks and rallying for labs to improve test quality.


Subject(s)
Laboratories/standards , Quality Control , Caribbean Region , Centers for Disease Control and Prevention, U.S. , Laboratories/organization & administration , Latin America , Pan American Health Organization , Planning Techniques , Predictive Value of Tests , Program Evaluation , Reference Values , United States
13.
Infect Immun ; 11(6): 1195-202, 1975 Jun.
Article in English | MEDLINE | ID: mdl-806521

ABSTRACT

A ribosomal preparation isolated from group A, type 14 Streptococcus pyogenes protected mice against a challenge of 1,000 mean lethal doses. Optimal immunization consisted of subcutaneous administration of 326 mug of protein with Freund incomplete adjuvant. Animals immunized with higher or lower antigen concentrations showed decreased survival. Freund incomplete adjuvant was necessary to insure optimum immunization. Immunochemical studies showed no M protein or C carbohydrate present in the ribosomal preparation. Mice optimally immunized with the type 14 ribosomal preparation were protected against heterologous challenge with M types 2, 5, 8, and 12. Protein-free ribonucleic acid extracts isolated from the type 14 ribosomal preparation did not protect mice against homologous challenge. But ribonucleic acid-free protein extracts showed 100% protection in mice after homologous challenge.


Subject(s)
Bacterial Vaccines/isolation & purification , Ribosomal Proteins/isolation & purification , Streptococcus pyogenes/immunology , Animals , Blood/microbiology , Centrifugation, Density Gradient , Electrophoresis, Polyacrylamide Gel , Immunization , Immunodiffusion , Mice , RNA, Ribosomal/isolation & purification , Spleen/microbiology , Ultracentrifugation
14.
Isr J Med Sci ; 23(6): 613-7, 1987 Jun.
Article in English | MEDLINE | ID: mdl-3667228

ABSTRACT

Mycoplasma hominis is a human genital pathogen with importance in postpartum pregnancy complications (postpartum fever/endometritis). Previous research has suggested that serum antibody levels to M. hominis are important in predicting which groups of women are at risk. M. hominis strain PG21 was examined by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and Western blots to determine which protein antigens would be good candidates for use in serologic tests. Western blots of strain PG21 were probed with acute and convalescent human sera from patients with culture-confirmed M. hominis infections, animal sera directed against strain PG21 and other M. hominis strains, and sera from patients with confirmed infections from other sexually transmitted diseases (STD). Western blot analysis showed that the prenatal (Groups I, II, III) and convalescent (Group IV) M. hominis human sera reacted with proteins with apparent MWs of 106, 67, 46, and 40 kilodaltons (kDa). Only the convalescent sera (Group IV) and the prenatal sera (Group III) reacted with proteins having apparent MWs of 58 and 50 kDa. Animal antisera directed against all strains of M. hominis examined showed that these proteins were reactive in all strains, and other STD human sera did not react with proteins in strain PG21 corresponding to the apparent MWs of 50 and 58 kDa. Preliminary evidence suggested that proteins with the apparent MWs of 50 and 58 kDa may be viable candidates for use in serologic tests for the detection of human anti-M. hominis antibodies and help to eliminate cross-reactivity observed with whole-cell lysates.


Subject(s)
Antibodies, Bacterial/biosynthesis , Genital Diseases, Female/immunology , Mycoplasma Infections/immunology , Mycoplasma/immunology , Pregnancy Complications, Infectious/immunology , Puerperal Infection/immunology , Adult , Antigens, Bacterial/immunology , Child, Preschool , Convalescence , Endometritis/etiology , Endometritis/immunology , Female , Genital Diseases, Female/etiology , Humans , Immunoelectrophoresis , Mycoplasma/classification , Mycoplasma/pathogenicity , Mycoplasma Infections/etiology , Pregnancy , Pregnancy Complications, Infectious/etiology , Puerperal Infection/etiology
15.
J Clin Microbiol ; 20(6): 1171-3, 1984 Dec.
Article in English | MEDLINE | ID: mdl-6440907

ABSTRACT

A total of 149 sera, including 79 pre- and posttreatment sera from 33 patients with disseminated gonococcal infections, 18 from patients with uncomplicated gonococcal infections, 6 from patients with pelvic inflammatory disease, 4 from patients with genital Chlamydia trachomatis infections, and 42 from normal volunteers, were examined for C-reactive protein with a latex agglutination C-reactive protein detection kit (Difco Laboratories, Detroit, Mich.). Results were quantitated with LC-Partigen C-reactive protein radial immuno-diffusion plates (Calbiochem-Behring, La Jolla, Calif.). Positive latex agglutination results were observed in all of the pretreatment sera and some of the posttreatment sera of patients with disseminated gonococcal infections and in two sera from patients with pelvic inflammatory disease, which corresponded to quantitative C-reactive protein levels in the radial immunodiffusion plates. C-reactive protein levels were not detectable in the serum samples from normal volunteers or patients with uncomplicated gonococcal infections or genital chlamydial infections. Positive latex agglutination occurred as early as 20 s in sera with high C-reactive protein levels, and all positive results were observed within 90 s of the 3-min test limit. Positive latex test results were obtained with C-reactive protein levels as low as 1 mg/dl (10 micrograms/ml).


Subject(s)
C-Reactive Protein/analysis , Gonorrhea/diagnosis , Latex Fixation Tests , Lymphogranuloma Venereum/diagnosis , Evaluation Studies as Topic , Female , Gonorrhea/blood , Humans , Immunodiffusion , Lymphogranuloma Venereum/blood , Pelvic Inflammatory Disease/blood
16.
J Clin Microbiol ; 15(2): 342-4, 1982 Feb.
Article in English | MEDLINE | ID: mdl-7068831

ABSTRACT

A simple medium containing yeast extract, phosphate, and hemin as major components has been formulated for the study of legionellae. The medium supports the growth of a wide range of clinical and environmental isolates, with plating efficiencies comparable to those of charcoal-yeast extract agar. In addition, it does not contain activated charcoal or other components which may be associated with adverse reactions in humans. The medium is buffered and transparent; therefore, it would be suitable for genetic studies, production of biological reagents such as antigens and skin tests for human use, and antibiotic susceptibility assays.


Subject(s)
Culture Media , Legionella/growth & development , Charcoal , Hemin , Yeasts
17.
J Infect Dis ; 139(5): 569-74, 1979 May.
Article in English | MEDLINE | ID: mdl-108344

ABSTRACT

Subcutaneous chambers were implanted in mice, injected with Neisseria gonorrhoeae, and supplemented with complement as a model for studying the immunogenicity and strain diversity of N. gonorrhoeae. Immunotypic resistance to N. gonorrhoeae in immunized mice was significantly (P less than 0.01) increased by injection of exogenous guinea pig complement into the host before challenge with gonococci. By using this model to test gonococcal isolates from various geographical areas, two highly immunogenic but immunotypically different gonococcal strains were identified. The piliated cells of these strains induced both complement-enhanced immunity and a degree of exogenous complement-independent immunity. The immunity in mice not treated with complement developed more slowly, was less effective, and waned earlier than that which was complement-dependent. Pretreatment with complement, although highly effective in preventing infection in immunized mice, was much less beneficial in terminating already established infections, even though bactericidal antibodies were present at the time of complement treatment. The mouse chamber model in which both complement-mediated and complement-independent mechanisms of protection can be evaluated may provide an additional tool for elucidating the immunology of gonococcal or other microbial infections.


Subject(s)
Complement System Proteins , Gonorrhea/immunology , Neisseria gonorrhoeae/immunology , Animals , Complement C2/deficiency , Complement C4/deficiency , Female , Gonorrhea/prevention & control , Guinea Pigs , Immune Sera/pharmacology , Mice , Mice, Inbred ICR , Skin/immunology , Virulence
18.
J Clin Microbiol ; 22(3): 379-82, 1985 Sep.
Article in English | MEDLINE | ID: mdl-3930560

ABSTRACT

A total of 101 isolates of penicillinase-producing and non-penicillinase-producing Neisseria gonorrhoeae with known nutritional requirements, plasmid content, and serovars, were examined for lectin agglutination patterns. These isolates were from outbreaks in Georgia, California, Hawaii, and Pennsylvania. Cell suspensions made from 16- to 18-h cultures were mixed with 14 different lectins, and the resultant agglutination patterns were classified as agglutination groups. Among the 101 isolates tested, 24 different agglutination groups were demonstrated. Of the organisms tested, 55% were located in 3 of the 24 groups, and 86% of the isolates reacted with the lectins Trichosanthes kinlowii, Griffonia simplicifolia I, peanut agglutinin, soybean agglutinin, potato agglutinin, and wheat germ agglutinin. One isolate did not react with peanut or potato agglutinin, five isolates lacked reactivity with potato agglutinin, and six isolates did not react with wheat germ agglutinin. Of the wheat germ-negative isolates, four were from Pennsylvania and were identical with regard to auxotype, plasmid content, serovar, and lectin group. The other two wheat germ-negative isolates were from California and were unrelated by the same criteria to the four Pennsylvania isolates and to each other. Among the isolates tested, there were no differences in lectin groups with regard to the sex of the patient. In the Georgia collection, agglutination with one lectin group was confined to isolates of serogroup IA. This association was not observed for the other geographic areas. Some isolates showing identical auxotype, plasmid content, and serovars could be differentiated based on lectin agglutination patterns, whereas other isolates were identical by all testing criteria.


Subject(s)
Gonorrhea/microbiology , Lectins/pharmacology , Neisseria gonorrhoeae/classification , Agglutination Tests , California , Carbohydrates/analysis , Female , Georgia , Hawaii , Humans , Male , Neisseria gonorrhoeae/analysis , Neisseria gonorrhoeae/genetics , Pennsylvania , Plasmids
19.
Infect Immun ; 23(3): 717-22, 1979 Mar.
Article in English | MEDLINE | ID: mdl-88414

ABSTRACT

Gonococci, irrespective of serotype or immunotype, varied significantly in their capacity to induce immunity in animal models, and in vitro serological relatedness did not always insure in vivo cross-protection. By using a serum bactericidal assay followed by in vivo cross-protection studies, new immunotypic strains which were highly protective were identified from cultures isolated in different geographical areas and from patients with various clinical manifestations. Beta-lactamase production and gonococcal immunotype did not appear as related characteristics in that certain penicillin-sensitive strains were highly effective in immunizing animals against infection with beta-lactamase producers. The findings of this study emphasize the importance of using appropriate biological tests and strains for the investigation of gonococcal immunity and vaccine development. Immunization with a combination of a few major gonococcal immunotypic immunogens may provide substantial protection against the majority of penicillin-sensitive and beta-lactamase-producing gonococci. Investigation of isolated immunotypic immunogens is in progress.


Subject(s)
Antigens, Bacterial/analysis , Neisseria gonorrhoeae/immunology , Animals , Antibody Specificity , Cross Reactions , Epitopes , Guinea Pigs , Immunization , Mice , Serotyping
20.
J Clin Microbiol ; 28(8): 1799-807, 1990 Aug.
Article in English | MEDLINE | ID: mdl-2168439

ABSTRACT

Results from laboratories performing indirect immunofluorescence (IIF) testing for human immunodeficiency virus type 1 antibody and participating in the Centers for Disease Control Model Performance Evaluation Program in 1988 are presented. Approximately 90% of all laboratories receiving specimen panels or questionnaires furnished results to the Centers for Disease Control. In September 1988, 111 reports were received from IIF laboratories from 34 states and nine countries; most of these laboratories did IIF testing in conjunction with other antibody tests. Hospital laboratories were the most common type of laboratory participating in the program. Laboratories that performed IIF employed fewer personnel and performed testing less frequently than did laboratories that performed enzyme immunoassays or Western blot (immunoblot) tests and were likely to use a commercial test kit. Most of the laboratories that referred specimens for IIF testing sent them to the state laboratory. The analytic specificity for the Model Performance Evaluation Program specimens was 98.5% when indeterminate results on a negative specimen were considered correct (negative) and 89.6% when indeterminate results on a negative specimen were considered incorrect; analytic sensitivity was 94.8% when indeterminate results on a positive specimen were correct (positive) and 91.4% when indeterminate results on a positive specimen were considered incorrect. When indeterminate results were considered correct, all types of laboratories (blood bank, state, hospital, independent, and other) had analytic specificities over 96%, and all manufacturers had analytic specificities above 95%. All types of laboratories had analytic sensitivities over 92%, and analytic sensitivities were above 94% for all manufacturers and reagent sources except Cellular Products. Comparison of percentages of correct responses between IIF and Western blot assays on those samples for which there was good agreement on the target interpretation revealed no significant differences. Both individual donor and diluted materials were included in the evaluations; the diluted donor material presented the greatest testing difficulty. Within-survey reproducibility was about 93% overall and by specimen type. Between-survey reproducibility was about 81% for negative and indeterminate specimens and 88.5% for positive specimens, for an overall between-survey reproducibility of 84.3%. Differences in performance were noted when results were compared by type of laboratory and test manufacturer.


Subject(s)
Acquired Immunodeficiency Syndrome/diagnosis , Fluorescent Antibody Technique , HIV-1 , Laboratories/standards , Acquired Immunodeficiency Syndrome/epidemiology , Centers for Disease Control and Prevention, U.S. , Evaluation Studies as Topic , Humans , Quality Assurance, Health Care , Reagent Kits, Diagnostic , Reproducibility of Results , Sensitivity and Specificity , Surveys and Questionnaires , Task Performance and Analysis , United States
SELECTION OF CITATIONS
SEARCH DETAIL