Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Anal Chem ; 95(27): 10186-10195, 2023 Jul 11.
Article in English | MEDLINE | ID: mdl-37384657

ABSTRACT

3D and 2D-cross-sectional X-ray fluorescence analysis of biological material is a powerful tool to image the distribution of elements and to understand and quantify metal homeostasis and the distribution of anthropogenic metals and nanoparticles with minimal preparation artifacts. Using tomograms recorded on cryogenically prepared leaves of Allium schoenoprasum, the cross-sectional distribution of physiologically relevant elements like calcium, potassium, manganese, and zinc could be tomographically reconstructed by peak fitting followed by a conventional maximum-likelihood algorithm with self-absorption correction to reveal the quantitative cross-sectional element distribution. If light elements such as S and P are located deep in the sample compared to the escape depth of their characteristic X-ray fluorescence lines, the quantitative reconstruction becomes inaccurate. As a consequence, noise is amplified to a magnitude where it might be misinterpreted as actual concentration. We show that a tomographic MCA hyperspectral reconstruction in combination with a self-absorption correction allows for fitting of the XRF spectra directly in real space, which significantly improves the qualitative and quantitative analysis of the light elements compared to the conventional method as noise and artifacts in the tomographic reconstruction are reduced. This reconstruction approach can substantially improve the quantitative analysis of trace elements as it allows the fitting of summed voxel spectra in anatomical regions of interest. The presented method can be applied to XRF 2D single-slice tomography data and 3D tomograms and is particularly relevant for, but not limited to, biological material in order to help retrieve self-absorption corrected quantitative reconstructions of the spatial distribution of light elements and ultra-trace-elements.

2.
Opt Express ; 27(6): 8639-8650, 2019 Mar 18.
Article in English | MEDLINE | ID: mdl-31052678

ABSTRACT

The recent success in the development of high-precision printing techniques allows one to manufacture free-standing polymer structures of high quality. Two-photon polymerization lithography is a mask-less technique with down to 100 nm resolution that provides full geometric freedom. It has recently been applied to the nanofabrication of X-ray compound refractive lenses (CRLs). In this article we report on the characterization of two sets of CRLs of different design produced by two-photon polymerization-induced lithography.

3.
Opt Express ; 25(25): 31640-31650, 2017 Dec 11.
Article in English | MEDLINE | ID: mdl-29245835

ABSTRACT

We present light induced refractive index changes in iron doped lithium niobate detected with a novel microscopy technique called ptychography. This method determines the change of the refractive index together with the intensity distribution of the writing beam from a single scan with a reconstructed spatial resolution of 3 µm and a sensitivity of the refractive index change of 10-5. We show that the light induced refractive index change is strongly connected to the intensity shape of the writing beam and that it shows the expected nonlocal behaviour. Applying the novel method to the investigation of the photorefractive effect offers an excellent opportunity to study this nonlocal response to the spatial distribution of the writing beam.

4.
J Microsc ; 241(1): 9-12, 2011 Jan.
Article in English | MEDLINE | ID: mdl-21118244

ABSTRACT

We used hard X-ray scanning microscopy with ptychographic coherent diffraction contrast to image a front-end processed passivated microchip fabricated in 80 nm technology. No sample preparation was needed to image buried interconnects and contact layers with a spatial resolution of slightly better than 40 nm. The phase shift in the sample is obtained quantitatively. With the additional knowledge of the elemental composition determined in parallel by X-ray fluorescence mapping, quantitative information about specific nanostructures is obtained. A significant enhancement in signal-to-noise ratio and spatial resolution is achieved compared to conventional hard X-ray scanning microscopy.

5.
Nat Commun ; 12(1): 3468, 2021 Jun 08.
Article in English | MEDLINE | ID: mdl-34103498

ABSTRACT

Cavitation bubbles can be seeded from a plasma following optical breakdown, by focusing an intense laser in water. The fast dynamics are associated with extreme states of gas and liquid, especially in the nascent state. This offers a unique setting to probe water and water vapor far-from equilibrium. However, current optical techniques cannot quantify these early states due to contrast and resolution limitations. X-ray holography with single X-ray free-electron laser pulses has now enabled a quasi-instantaneous high resolution structural probe with contrast proportional to the electron density of the object. In this work, we demonstrate cone-beam holographic flash imaging of laser-induced cavitation bubbles in water with nanofocused X-ray free-electron laser pulses. We quantify the spatial and temporal pressure distribution of the shockwave surrounding the expanding cavitation bubble at time delays shortly after seeding and compare the results to numerical simulations.

6.
J Phys Condens Matter ; 21(26): 264012, 2009 Jul 01.
Article in English | MEDLINE | ID: mdl-21828460

ABSTRACT

A one-dimensional silver (Ag) nanoparticle gradient layer is prepared from an aqueous colloidal solution upon a polystyrene (PS) coated silicon (Si) substrate. For preparation two walls of different wettability are used. The 40 nm PS-layer exhibits a locally constant film thickness due to the strong roughness correlation with the underlying Si-substrate and is less wettable as compared to the glass plate placed above. The Ag nanoparticles have a triangular prism-like shape. The structural characterization of the obtained complex gradient formed by drying is performed with microbeam grazing incidence small-angle x-ray scattering based on compound refractive lenses. Due to the adsorption from aqueous solution in the selective geometry a double gradient type structure defined by two areas with characteristic lateral lengths and a cross-over regime between both is observed.

7.
Sci Adv ; 5(3): eaau8044, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30873430

ABSTRACT

Under rapid high-temperature, high-pressure loading, lattices exhibit complex elastic-inelastic responses. The dynamics of these responses are challenging to measure experimentally because of high sample density and extremely small relevant spatial and temporal scales. Here, we use an x-ray free-electron laser providing simultaneous in situ direct imaging and x-ray diffraction to spatially resolve lattice dynamics of silicon under high-strain rate conditions. We present the first imaging of a new intermediate elastic feature modulating compression along the axis of applied stress, and we identify the structure, compression, and density behind each observed wave. The ultrafast probe x-rays enabled time-resolved characterization of the intermediate elastic feature, which is leveraged to constrain kinetic inhibition of the phase transformation between 2 and 4 ns. These results not only address long-standing questions about the response of silicon under extreme environments but also demonstrate the potential for ultrafast direct measurements to illuminate new lattice dynamics.

8.
Rev Sci Instrum ; 78(7): 073702, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17672761

ABSTRACT

We have designed and built a compact x-ray microtomography system to perform element mapping and absorption imaging by exploiting scanning fluorescence tomography and full-field transmission microtomography, respectively. It is based on a low power microfocus tube and is potentially appropriate for x-ray diagnostics in space. Full-field transmission tomography yields the three-dimensional inner structure of an object. Fluorescence microtomography provides the element distribution on a virtual section through the sample. Both techniques can be combined for appropriate samples. Microradiography as well as fluorescence mapping are also possible. For fluorescence microtomography a small and intensive microbeam is required. It is generated using a polycapillary optic. Operating the microfocus tube with a molybdenum target at 12 W, a microbeam with a full width at half maximum lateral extension of 16 microm and a flux of about 10(8) photonss is generated. As an example of application, this beam is used to determine the element distribution inside dried plant samples. For full-field scanning tomography, the x-ray optic is removed and the sample is imaged in magnifying projection onto a two-dimensional position sensitive detector. Depending on the sample size, a spatial resolution down to about 10 microm is possible in this mode. The method is demonstrated by three-dimensional imaging of a rat humerus.


Subject(s)
Absorptiometry, Photon/instrumentation , Tomography, X-Ray/instrumentation , Absorptiometry, Photon/methods , Equipment Design , Equipment Failure Analysis , Miniaturization , Reproducibility of Results , Sensitivity and Specificity
9.
Rev Sci Instrum ; 82(10): 105108, 2011 Oct.
Article in English | MEDLINE | ID: mdl-22047330

ABSTRACT

A laboratory based high resolution x-ray radiograph was developed for the investigation of solidification dynamics in alloys. It is based on a low-power microfocus x-ray tube and is potentially appropriate for x-ray diagnostics in space. The x-ray microscope offers a high spatial resolution down to approximately 5 µm. Dynamic processes can be resolved with a frequency of up to 6 Hz. In reference experiments, the setup was optimized to yield a high contrast for AlCu-alloys. With samples of about 150 µm thickness, high quality image sequences of the solidification process were obtained with high resolution in time and space.

10.
J Phys Condens Matter ; 23(18): 184111, 2011 May 11.
Article in English | MEDLINE | ID: mdl-21508480

ABSTRACT

The structure and flow of droplets on solid surfaces is investigated with imaging and scattering techniques and compared to simulations. To access nanostructures at the liquid-solid interface advanced scattering techniques such as grazing incidence small-angle x-ray scattering (GISAXS) with micro- and nanometer-sized beams, GISAXS and in situ imaging ellipsometry and GISAXS tomography are used. Using gold nanoparticle suspensions, structures observed in the wetting area due to deposition are probed in situ during the drying of the droplets. After drying, nanostructures in the wetting area and inside the dried droplets are monitored. In addition to drying, a macroscopic movement of droplets is caused by body forces acting on an inclined substrate. The complexity of the solid surfaces is increased from simple silicon substrates to binary polymer brushes, which undergo a switching due to the liquid in the droplet. Nanostructures introduced in the polymer brush due to the movement of droplets are observed.


Subject(s)
Gold/chemistry , Nanostructures/chemistry , Physics/methods , Computer Simulation , Electronics , Nanoparticles/chemistry , Nanotechnology/methods , Particle Size , Polymers/chemistry , Scattering, Radiation , Silicon , Surface Properties , Wettability , X-Rays
11.
Phys Rev Lett ; 101(9): 090801, 2008 Aug 29.
Article in English | MEDLINE | ID: mdl-18851597

ABSTRACT

Coherent x-ray diffraction imaging is an x-ray microscopy technique with the potential of reaching spatial resolutions well beyond the diffraction limits of x-ray microscopes based on optics. However, the available coherent dose at modern x-ray sources is limited, setting practical bounds on the spatial resolution of the technique. By focusing the available coherent flux onto the sample, the spatial resolution can be improved for radiation-hard specimens. A small gold particle (size <100 nm) was illuminated with a hard x-ray nanobeam (E=15.25 keV, beam dimensions approximately 100 x 100 nm2) and is reconstructed from its coherent diffraction pattern. A resolution of about 5 nm is achieved in 600 s exposure time.

12.
Phys Rev Lett ; 94(5): 054802, 2005 Feb 11.
Article in English | MEDLINE | ID: mdl-15783651

ABSTRACT

We address the question of what is the smallest spot size that hard x rays can be focused to using refractive optics. A thick refractive x-ray lens is considered, whose aperture is gradually (adiabatically) adapted to the size of the beam as it converges to the focus. These adiabatically focusing lenses are shown to have a relatively large numerical aperture, focusing hard x rays down to a lateral size of 2 nm (FWHM), well below the theoretical limit for focusing with waveguides [C. Bergemann, Phys. Rev. Lett.912003204801].

SELECTION OF CITATIONS
SEARCH DETAIL