Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 114
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Eur Heart J ; 44(33): 3181-3195, 2023 09 01.
Article in English | MEDLINE | ID: mdl-37350747

ABSTRACT

AIMS: The safety and efficacy of transcatheter aortic valve replacement (TAVR) with contemporary balloon expandable transcatheter valves in patients with cardiogenic shock (CS) remain largely unknown. In this study, the TAVRs performed for CS between June 2015 and September 2022 using SAPIEN 3 and SAPIEN 3 Ultra bioprosthesis from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry were analysed. METHODS AND RESULTS: CS was defined as: (i) coding of CS within 24 h on Transcatheter Valve Therapy Registry form; and/or (ii) pre-procedural use of inotropes or mechanical circulatory support devices and/or (iii) cardiac arrest within 24 h prior to TAVR. The control group was comprised of all the other patients undergoing TAVR. Baseline characteristics, all-cause mortality, and major complications at 30-day and 1-year outcomes were reported. Landmark analysis was performed at 30 days post-TAVR. Cox-proportional multivariable analysis was performed to determine the predictors of all-cause mortality at 1 year. A total of 309 505 patients underwent TAVR with balloon-expandable valves during the study period. Of these, 5006 patients presented with CS prior to TAVR (1.6%). The mean Society of Thoracic Surgeons score was 10.76 ± 10.4. The valve was successfully implanted in 97.9% of patients. Technical success according to Valve Academic Research Consortium-3 criteria was 94.5%. In a propensity-matched analysis, CS was associated with higher in-hospital (9.9% vs. 2.7%), 30-day (12.9% vs. 4.9%), and 1-year (29.7% vs. 22.6%) mortality compared to the patients undergoing TAVR without CS. In the landmark analysis after 30 days, the risk of 1-year mortality was similar between the two groups [hazard ratio (HR) 1.07, 95% confidence interval (CI) 0.95-1.21]. Patients who were alive at 1 year noted significant improvements in functional class (Class I/II 89%) and quality of life (ΔKCCQ score +50). In the multivariable analysis, older age (HR 1.02, 95% CI 1.02-1.03), peripheral artery disease (HR 1.25, 95% CI 1.06-1.47), prior implantation of an implantable cardioverter-defibrillator (HR 1.37, 95% CI 1.07-1.77), patients on dialysis (HR 2.07, 95% CI 1.69-2.53), immunocompromised status (HR 1.33, 95% CI 1.05-1.69), New York Heart Association class III/IV symptoms (HR 1.50, 95% CI 1.06-2.12), lower aortic valve mean gradient, lower albumin levels, lower haemoglobin levels, and lower Kansas City Cardiomyopathy Questionnaire scores were independently associated with 1-year mortality. CONCLUSION: This large observational real-world study demonstrates that the TAVR is a safe and effective treatment for aortic stenosis patients presenting with CS. Patients who survived the first 30 days after TAVR had similar mortality rates to those who were not in CS.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , United States , Transcatheter Aortic Valve Replacement/methods , Shock, Cardiogenic , Quality of Life , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnosis , Treatment Outcome , Aortic Valve/surgery , Registries , Risk Factors
2.
Eur Heart J ; 44(44): 4650-4661, 2023 Nov 21.
Article in English | MEDLINE | ID: mdl-37632738

ABSTRACT

BACKGROUND AND AIMS: Guideline-directed medical therapy (GDMT) is recommended before mitral valve transcatheter edge-to-edge repair (MTEER) in patients with heart failure (HF) and severe functional mitral regurgitation (FMR). Whether MTEER is being performed on the background of optimal GDMT in clinical practice is unknown. METHODS: Patients with left ventricular ejection fraction (LVEF) < 50% who underwent MTEER for FMR from 23 July 2019 to 31 March 2022 in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry were identified. Pre-procedure GDMT utilization was assessed. Cox proportional hazards models were constructed to evaluate associations between pre-MTEER therapy (no/single, double, or triple therapy) and risk of 1-year mortality or HF hospitalization (HFH). RESULTS: Among 4199 patients across 449 sites, beta-blockers, angiotensin-converting enzyme inhibitors/angiotensin receptor blockers, mineralocorticoid receptor antagonists, and angiotensin receptor-neprilysin inhibitors were used in 85.1%, 44.4%, 28.6%, and 19.9% before MTEER, respectively. Triple therapy was prescribed for 19.2%, double therapy for 38.2%, single therapy for 36.0%, and 6.5% were on no GDMT. Significant centre-level variation in the proportion of patients on pre-intervention triple therapy was observed (0%-61%; adjusted median odds ratio 1.48 [95% confidence interval (CI) 1.25-3.88]; P < .001). In patients eligible for 1-year follow-up (n = 2014; 341 sites), the composite rate of 1-year mortality or HFH was lowest in patients prescribed triple therapy (23.0%) compared with double (24.8%), single (35.7%), and no (41.1%) therapy (P < .01 comparing across groups). Associations persisted after accounting for relevant clinical characteristics, with lower risk in patients prescribed triple therapy [adjusted hazard ratio (aHR) 0.73, 95% CI .55-.97] and double therapy (aHR 0.69, 95% CI .56-.86) before MTEER compared with no/single therapy. CONCLUSIONS: Under one-fifth of patients with LVEF <50% who underwent MTEER for FMR in this US nationwide registry were prescribed comprehensive GDMT, with substantial variation across sites. Compared with no/single therapy, triple and double therapy before MTEER were independently associated with reduced risk of mortality or HFH 1 year after intervention.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Treatment Outcome , Stroke Volume , Ventricular Function, Left , Mitral Valve Insufficiency/etiology , Heart Valve Prosthesis Implantation/methods , Heart Failure/etiology , Registries
3.
Eur Heart J ; 44(46): 4862-4873, 2023 Dec 07.
Article in English | MEDLINE | ID: mdl-37930776

ABSTRACT

BACKGROUND AND AIMS: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes. METHODS: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy. Major adverse events, reduction in TR grade and haemodynamic outcomes by echocardiography, and clinical, functional, and quality-of-life parameters are reported to one year. RESULTS: Enrolled patients were 71.0% female, mean age 78.7 years, 88.0% ≥ severe TR, and 75.4% New York Heart Association classes III-IV. Tricuspid regurgitation was reduced to ≤mild in 97.6% (P < .001), with increases in stroke volume (10.5 ± 16.8 mL, P < .001) and cardiac output (0.6 ± 1.2 L/min, P < .001). New York Heart Association class I or II was achieved in 93.3% (P < .001), Kansas City Cardiomyopathy Questionnaire score increased by 25.7 points (P < .001), and six-minute walk distance increased by 56.2 m (P < .001). All-cause mortality was 9.1%, and 10.2% of patients were hospitalized for heart failure. CONCLUSIONS: In an elderly, highly comorbid population with ≥moderate TR, patients receiving transfemoral EVOQUE transcatheter TV replacement had sustained TR reduction, significant increases in stroke volume and cardiac output, and high survival and low hospitalization rates with improved clinical, functional, and quality-of-life outcomes to one year. Funded by Edwards Lifesciences, TRISCEND ClinicalTrials.gov number, NCT04221490.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Female , Aged , Male , Tricuspid Valve Insufficiency/epidemiology , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/methods , Prospective Studies , Quality of Life , Treatment Outcome , Cardiac Catheterization/methods , Severity of Illness Index
5.
Catheter Cardiovasc Interv ; 100(6): 1119-1131, 2022 11.
Article in English | MEDLINE | ID: mdl-36183395

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has increasingly been utilized in patients with bicuspid aortic valve (BAV) related aortic stenosis (AS) with insufficient large-scale data on its safety. METHODS: The Nationwide Inpatient Sample and Nationwide Readmission Database (2011-2018) were queried to identify patients undergoing TAVI for BAV versus trileaflet aortic valve (TAV) associated AS. The in-hospital, 30- and 180-day odds of outcomes were assessed using a propensity-matched analysis (PSM) to calculate adjusted odds ratios (aOR) with its 95% confidence interval (CI). RESULTS: A total of 216,723 TAVI (TAV: 214,050 and BAV: 2,673) crude and 5,347 matched population (TAV: 2,674 and BAV: 2,673) was included in the final analysis. At index admission, the adjusted odds of in-hospital mortality (aOR: 1.57, 95% CI: 0.67-3.66), stroke (aOR: 0.77, 95% CI: 0.38-1.57), cardiac tamponade (aOR: 0.75, 95% CI: 0.17-3.36), vascular complications (aOR: 0.33, 95% CI: 0.09-1.22), cardiogenic shock (aOR: 1.77, 95% CI: 0.93-3.38), paravalvular leak (aOR: 0.55, 95% CI: 0.26-1.14), need for mechanical circulatory support device, and permanent pacemaker implantation (PPM) (aOR: 1.02, 95% CI: 0.69-1.52) were not significantly different between TAVI for BAV versus TAV. At 30- and 180-day follow-up duration, the risk of stroke and major postprocedural complications remained similar, except that TAVI in BAV had a higher incidence of PPM implantation compared with TAV. The yearly trend showed an increase in the utilization of TAVI for both TAV and BAV and a steady decline in the overall annual rate of in-hospital complications. CONCLUSION: TAVI utilization in patients with BAV has increased over the recent years. The relative odds of in-hospital mortality, and all other major complications, were similar between patients undergoing TAVI for BAV- and TAV-related AS.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Stroke , Transcatheter Aortic Valve Replacement , Humans , Inpatients , Patient Readmission , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/surgery , Heart Valve Diseases/etiology , Treatment Outcome , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Stroke/etiology
6.
Catheter Cardiovasc Interv ; 98(3): 520-525, 2021 09.
Article in English | MEDLINE | ID: mdl-33128442

ABSTRACT

Since the advent of coronary angiography, the standard for reporting of coronary lesion severity has been to utilize percent diameter stenosis (%DS). Given the imperfections of %DS as well as the widespread availability of intraprocedural intracoronary imaging and physiology assessment, it is time to consider a simpler yet more clinically relevant lesion assessment system. We compiled ten actual cases and presented these cases to 10 operators, providing 100 independent lesion assessments. For each case, operators were asked to describe lesions using %DS and a simplified lesion assessment system. We assessed the relationship between %DS and qualitative lesion assessment as well as the relationship of both measurements to the chosen plan. Greater variability exists with %DS than with qualitative lesion assessment. Despite this, there is good correlation between %DS and the qualitative lesion assessment (ρ = 0.8221). There remains overlap of lesion assessment using the qualitative lesion assessment tool suggesting that even with this simpler tool, there remains interobserver variability (ICC = 0.5164, 95% confidence interval [CI] 0.2924-0.7955). When assessing how both lesion assessment, there appears to be a stronger correlation between the qualitative lesion assessment and the chosen plan versus the %DS and the chosen plan (ρ = 0.9069 vs ρ = 0.8001, P < .01). Given the superior performance of the proposed qualitative system and the ability to estimate lesion severity using both anatomic and clinical factors, we feel that professional societies and clinicians should begin to embrace this simplified means of lesion assessment.


Subject(s)
Coronary Stenosis , Fractional Flow Reserve, Myocardial , Coronary Angiography , Coronary Stenosis/diagnostic imaging , Coronary Vessels/diagnostic imaging , Humans , Observer Variation , Severity of Illness Index , Treatment Outcome
7.
Catheter Cardiovasc Interv ; 98(4): E637-E646, 2021 10.
Article in English | MEDLINE | ID: mdl-34004077

ABSTRACT

OBJECTIVES: We report the 30-day outcomes from the roll-in cohort of the CLASP IID trial, representing the first procedures performed by each site. BACKGROUND: The currently enrolling CLASP IID/IIF pivotal trial is a multicenter, prospective, randomized trial assessing the safety and effectiveness of the PASCAL transcatheter valve repair system in patients with clinically significant MR. The trial allows for up to three roll-in patients per site. METHODS: Eligibility criteria were: DMR ≥3+, prohibitive surgical risk, and deemed suitable for transcatheter repair by the local heart team. Trial oversight included a central screening committee and echocardiographic core laboratory. The primary safety endpoint was a 30-day composite MAE: cardiovascular mortality, stroke, myocardial infarction (MI), new need for renal replacement therapy, severe bleeding, and non-elective mitral valve re-intervention, adjudicated by an independent clinical events committee. Thirty-day echocardiographic, functional, and quality of life outcomes were assessed. RESULTS: A total of 45 roll-in patients with mean age of 83 years and 69% in NYHA class III/IV were treated. Successful implantation was achieved in 100%. The 30-day composite MAE rate was 8.9% including one cardiovascular death (2.2%) due to severe bleeding from a hemorrhagic stroke, one MI, and no need for re-intervention. MR≤1+ was achieved in 73% and ≤2+ in 98% of patients. 89% of patients were in NYHA class I/II (p < .001) with improvements in 6MWD (30 m; p = .054) and KCCQ (17 points; p < .001). CONCLUSIONS: Early results representing sites with first experience with the PASCAL repair system showed favorable 30-day outcomes in patients with DMR≥3+ at prohibitive surgical risk.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Aged, 80 and over , Heart Valve Prosthesis Implantation/adverse effects , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Prospective Studies , Quality of Life , Treatment Outcome
8.
J Nucl Cardiol ; 28(2): 579-588, 2021 Apr.
Article in English | MEDLINE | ID: mdl-31044406

ABSTRACT

BACKGROUND: We investigated role of coronary microvascular disease (CMD) in maladaptive LV remodeling and prognosis in patients with aortic sclerosis or stenosis and no overt CAD. METHODS: This was a retrospective cohort study of patients with aortic sclerosis or stenosis, normal myocardial perfusion and LV ejection fraction (EF) > 50% (n = 43) and matched controls without AS (n = 43). PET and echocardiograms were performed within 1 year of each other. Myocardial perfusion and myocardial flow reserve (MFR) were quantified using PET imaging. LV structure and function, including global longitudinal strain (GLS), were quantified by transthoracic echocardiography. RESULTS: Global MFR declined with increasing AS severity (P = 0.04). Probability of impaired MFR increased with severity of adverse LV remodeling (OR 1.88, CI 1.03 to 3.41, P =0.04). Reduced MFR associated with impaired GLS (r = - 0.29, P = 0.002) and associated with reduced MACE-free survival at 7.27 years median follow-up. Adjusted annualized rate of MACE was highest in those with impaired GLS and MFR and lowest in those with normal GLS and MFR (30.99% vs 1.86%, P =0.002). CONCLUSION AND RELEVANCE: In patients with AS and no overt CAD, impaired MFR associates with adverse LV remodeling and subclinical LV mechanical dysfunction, and is a marker increased clinical risk.


Subject(s)
Aortic Valve Stenosis/physiopathology , Coronary Circulation/physiology , Ventricular Remodeling/physiology , Aged , Aged, 80 and over , Aortic Valve Stenosis/complications , Female , Fractional Flow Reserve, Myocardial , Humans , Male , Microcirculation/physiology , Middle Aged , Retrospective Studies
9.
JAMA ; 326(11): 1034-1044, 2021 09 21.
Article in English | MEDLINE | ID: mdl-34546301

ABSTRACT

Importance: There are limited data on outcomes of transcatheter aortic valve replacement (TAVR) for bicuspid aortic stenosis in patients at low surgical risk. Objective: To compare the outcomes of TAVR with a balloon-expandable valve for bicuspid vs tricuspid aortic stenosis in patients who are at low surgical risk. Design, Setting, and Participants: Registry-based cohort study of patients undergoing TAVR at 684 US centers. Participants were enrolled in the Society of Thoracic Surgeons (STS)/American College of Cardiology Transcatheter Valve Therapies Registry from June 2015 to October 2020. Among 159 661 patients (7058 bicuspid, 152 603 tricuspid), 37 660 patients (3243 bicuspid and 34 417 tricuspid) who were at low surgical risk (defined as STS risk score <3%) were included in the analysis. Exposures: TAVR for bicuspid vs tricuspid aortic stenosis. Main Outcomes and Measures: Coprimary outcomes were 30-day and 1-year mortality and stroke. Secondary outcomes included procedural complications and valve hemodynamics. Results: Among 159 661 patients (7058 bicuspid; 152 603 tricuspid), 3168 propensity-matched pairs of patients with bicuspid and tricuspid aortic stenosis at low surgical risk were analyzed (mean age, 69 years; 69.8% men; mean [SD] STS-predicted risk of mortality, 1.7% [0.6%] for bicuspid and 1.7% [0.7%] for tricuspid). There was no significant difference between the bicuspid and tricuspid groups' rates of death at 30 days (0.9% vs 0.8%; hazard ratio [HR], 1.18 [95% CI, 0.68-2.03]; P = .55) and at 1 year (4.6% vs 6.6%; HR, 0.75 [95% CI, 0.55-1.02]; P = .06) or stroke at 30 days (1.4% vs 1.2%; HR, 1.14 [95% CI, 0.73-1.78]; P = .55) and at 1 year (2.0% vs 2.1%; HR 1.03 [95% CI, 0.69-1.53]; P = .89).There were no significant differences between the bicuspid and tricuspid groups in procedural complications, valve hemodynamics (aortic valve gradient: 13.2 mm Hg vs 13.5 mm Hg; absolute risk difference [RD], 0.3 mm Hg [95% CI, -0.9 to 0.3 mm Hg]), and moderate or severe paravalvular leak (3.4% vs 2.1%; absolute RD, 1.3% [95% CI, -0.6% to 3.2%]). Conclusions and Relevance: In this preliminary, registry-based study of propensity-matched patients at low surgical risk who had undergone TAVR for aortic stenosis, patients treated for bicuspid vs tricuspid aortic stenosis had no significant difference in mortality or stroke at 30 days or 1 year. Because of the potential for selection bias and absence of a control group treated surgically for bicuspid aortic stenosis, randomized trials are needed to adequately assess the efficacy and safety of transcatheter aortic valve replacement for bicuspid aortic stenosis in patients at low surgical risk.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bicuspid Aortic Valve Disease/surgery , Stroke/etiology , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/mortality , Cohort Studies , Female , Humans , Male , Propensity Score , Registries , Risk Factors , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
10.
Catheter Cardiovasc Interv ; 96(3): 659-663, 2020 09 01.
Article in English | MEDLINE | ID: mdl-32251546

ABSTRACT

The coronavirus disease-2019 (COVID-19) pandemic has strained health care resources around the world, causing many institutions to curtail or stop elective procedures. This has resulted in an inability to care for patients with valvular and structural heart disease in a timely fashion, potentially placing these patients at increased risk for adverse cardiovascular complications, including CHF and death. The effective triage of these patients has become challenging in the current environment, as clinicians have had to weigh the risk of bringing susceptible patients into the hospital environment during the COVID-19 pandemic against the risk of delaying a needed procedure. In this document, the authors suggest guidelines for how to triage patients in need of structural heart disease interventions and provide a framework for how to decide when it may be appropriate to proceed with intervention despite the ongoing pandemic. In particular, the authors address the triage of patients in need of transcatheter aortic valve replacement and percutaneous mitral valve repair. The authors also address procedural issues and considerations for the function of structural heart disease teams during the COVID-19 pandemic.


Subject(s)
Cardiac Surgical Procedures/statistics & numerical data , Coronavirus Infections/epidemiology , Heart Diseases/surgery , Pandemics/statistics & numerical data , Pneumonia, Viral/epidemiology , Practice Guidelines as Topic , Triage/standards , COVID-19 , Cardiac Surgical Procedures/methods , Cardiology/methods , Cardiology/standards , Coronavirus Infections/prevention & control , Cross Infection/prevention & control , Female , Heart Diseases/diagnostic imaging , Humans , Male , Occupational Health/statistics & numerical data , Pandemics/prevention & control , Patient Safety , Pneumonia, Viral/prevention & control , Societies, Medical , Triage/statistics & numerical data , United States
11.
J Card Surg ; 35(12): 3555-3559, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32906188

ABSTRACT

BACKGROUND: Given the recent growth in the number of MitraClip procedures in patients with functional mitral regurgitation (MR), there is interest in an echocardiographic index to predict technical success before intervention. We investigated the utility of a novel leaflet coaptation index (LCI) to predict outcomes after MitraClip in functional MR patients. METHODS: Forty consecutive patients with functional MR who underwent MitraClip were included. The LCI was defined as the coapted leaflet length divided by the anteroposterior diameter of the mitral annulus. The coapted leaflet length was calculated by separately tracing the total length of the mitral valve leaflets at early and end systole on transesophageal echocardiography. The primary endpoint was defined as residual MR ≥ moderate after MitraClip. RESULTS: The LCI was significantly associated with residual MR ≥ moderate (odds ratio, 0.827; 95% confidence interval, 0.696-0.982; p = .030) with the cut-off LCI value of 0.14 (sensitivity 70.4%, specificity 69.2%, c-statistic 0.815; p = .001). CONCLUSION: This novel index may be a useful adjunct that can be incorporated into the armamentarium of contemporary clinical performance risk prediction tools for MitraClip success.


Subject(s)
Mitral Valve Annuloplasty , Mitral Valve Insufficiency , Echocardiography, Transesophageal , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Time Factors , Treatment Outcome
12.
J Card Surg ; 35(3): 571-579, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31981435

ABSTRACT

BACKGROUND: Patients with underlying interstitial lung disease (ILD) who undergo cardiac surgery are at high risk of postoperative pulmonary complications. It remains unclear if transcatheter aortic valve replacement (TAVR) offers any benefit over surgical aortic valve replacement (SAVR) in ILD patients with severe aortic stenosis. METHODS: All adult patients with a diagnosis of ILD who underwent either a TAVR or isolated SAVR between January 2002 and December 2017 were retrospectively reviewed. Operative mortality, 30-day readmissions, and adjusted 1-year survival were compared between the two cohorts. RESULTS: The overall cohort included 52 TAVR and 74 SAVR patients. While TAVR patients were significantly older (77.2 vs 72.9 years) with higher Society of Thoracic Surgeons predicted risk of mortality (STS-PROM) scores compared with SAVR patients (6.29 vs 4.49; all P < .02), operative mortality was similar (5.8% vs 4.1%; P = .45). Rates of postoperative stroke, permanent pacemaker implantation, reintubation, and 30-day readmissions did not differ between the two groups (all P > .46). However, TAVR was associated with significantly shorter hospital and intensive care unit (ICU) length of stay, shorter ventilation times, and less requirement for ICU admission (all P < .05). Thirty-day readmissions and adjusted 1-year survival were also similar between the two groups (hazard ratio for TAVR vs SAVR = 1.34; 95% CI: 0.7-2.6). CONCLUSIONS: Among ILD patients with symptomatic aortic stenosis, TAVR was associated with comparable operative and risk-adjusted 1-year survival to SAVR. TAVR patients also had shorter ventilator times, ICU and hospital stay despite being at higher risk. Together, our findings suggest that TAVR may be a better option in this unique cohort.


Subject(s)
Aortic Valve Stenosis/complications , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Lung Diseases, Interstitial/complications , Postoperative Complications , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Female , Humans , Length of Stay , Male , Middle Aged , Operative Time , Risk , Severity of Illness Index , Treatment Outcome
13.
JAMA ; 321(22): 2193-2202, 2019 06 11.
Article in English | MEDLINE | ID: mdl-31184741

ABSTRACT

Importance: Transcatheter aortic valve replacement (TAVR) indications are expanding, leading to an increasing number of patients with bicuspid aortic stenosis undergoing TAVR. Pivotal randomized trials conducted to obtain US Food and Drug Administration approval excluded bicuspid anatomy. Objective: To compare the outcomes of TAVR with a balloon-expandable valve for bicuspid vs tricuspid aortic stenosis. Design, Setting, and Participants: Registry-based prospective cohort study of patients undergoing TAVR at 552 US centers. Participants were enrolled in the Society of Thoracic Surgeons (STS)/American College of Cardiology (ACC) Transcatheter Valve Therapies Registry from June 2015 to November 2018. Exposures: TAVR for bicuspid vs tricuspid aortic stenosis. Main Outcomes and Measures: Primary outcomes were 30-day and 1-year mortality and stroke. Secondary outcomes included procedural complications, valve hemodynamics, and quality of life assessment. Results: Of 81 822 consecutive patients with aortic stenosis (2726 bicuspid; 79 096 tricuspid), 2691 propensity-score matched pairs of bicuspid and tricuspid aortic stenosis were analyzed (median age, 74 years [interquartile range {IQR}, 66-81 years]; 39.1%, women; mean [SD] STS-predicted risk of mortality, 4.9% [4.0%] and 5.1% [4.2%], respectively). All-cause mortality was not significantly different between patients with bicuspid and tricuspid aortic stenosis at 30 days (2.6% vs 2.5%; hazard ratio [HR], 1.04, [95% CI, 0.74-1.47]) and 1 year (10.5% vs 12.0%; HR, 0.90 [95% CI, 0.73-1.10]). The 30-day stroke rate was significantly higher for bicuspid vs tricuspid aortic stenosis (2.5% vs 1.6%; HR, 1.57 [95% CI, 1.06-2.33]). The risk of procedural complications requiring open heart surgery was significantly higher in the bicuspid vs tricuspid cohort (0.9% vs 0.4%, respectively; absolute risk difference [RD], 0.5% [95% CI, 0%-0.9%]). There were no significant differences in valve hemodynamics. There were no significant differences in moderate or severe paravalvular leak at 30 days (2.0% vs 2.4%; absolute RD, 0.3% [95% CI, -1.3% to 0.7%]) and 1 year (3.2% vs 2.5%; absolute RD, 0.7% [95% CI, -1.3% to 2.7%]). At 1 year there was no significant difference in improvement in quality of life between the groups (difference in improvement in the Kansas City Cardiomyopathy Questionnaire overall summary score, -2.4 [95% CI, -5.1 to 0.3]; P = .08). Conclusions and Relevance: In this preliminary, registry-based study of propensity-matched patients who had undergone transcatheter aortic valve replacement for aortic stenosis, patients with bicuspid vs tricuspid aortic stenosis had no significant difference in 30-day or 1-year mortality but had increased 30-day risk for stroke. Because of the potential for selection bias and the absence of a control group treated surgically for bicuspid stenosis, randomized trials are needed to adequately assess the efficacy and safety of transcatheter aortic valve replacement for bicuspid aortic stenosis.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/abnormalities , Stroke/etiology , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Aged , Aged, 80 and over , Aortic Valve/surgery , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Postoperative Complications/mortality , Propensity Score , Prospective Studies , Registries , Risk
14.
Circulation ; 135(17): e927-e999, 2017 Apr 25.
Article in English | MEDLINE | ID: mdl-28356445

ABSTRACT

BACKGROUND: Kawasaki disease is an acute vasculitis of childhood that leads to coronary artery aneurysms in ≈25% of untreated cases. It has been reported worldwide and is the leading cause of acquired heart disease in children in developed countries. METHODS AND RESULTS: To revise the previous American Heart Association guidelines, a multidisciplinary writing group of experts was convened to review and appraise available evidence and practice-based opinion, as well as to provide updated recommendations for diagnosis, treatment of the acute illness, and long-term management. Although the cause remains unknown, discussion sections highlight new insights into the epidemiology, genetics, pathogenesis, pathology, natural history, and long-term outcomes. Prompt diagnosis is essential, and an updated algorithm defines supplemental information to be used to assist the diagnosis when classic clinical criteria are incomplete. Although intravenous immune globulin is the mainstay of initial treatment, the role for additional primary therapy in selected patients is discussed. Approximately 10% to 20% of patients do not respond to initial intravenous immune globulin, and recommendations for additional therapies are provided. Careful initial management of evolving coronary artery abnormalities is essential, necessitating an increased frequency of assessments and escalation of thromboprophylaxis. Risk stratification for long-term management is based primarily on maximal coronary artery luminal dimensions, normalized as Z scores, and is calibrated to both past and current involvement. Patients with aneurysms require life-long and uninterrupted cardiology follow-up. CONCLUSIONS: These recommendations provide updated and best evidence-based guidance to healthcare providers who diagnose and manage Kawasaki disease, but clinical decision making should be individualized to specific patient circumstances.


Subject(s)
American Heart Association , Mucocutaneous Lymph Node Syndrome/diagnostic imaging , Mucocutaneous Lymph Node Syndrome/therapy , Algorithms , Clinical Decision-Making , Consensus , Critical Pathways/standards , Decision Support Techniques , Humans , Mucocutaneous Lymph Node Syndrome/epidemiology , Predictive Value of Tests , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , United States
15.
Catheter Cardiovasc Interv ; 91(4): 798-805, 2018 03 01.
Article in English | MEDLINE | ID: mdl-28988432

ABSTRACT

OBJECTIVES: To assess the impact of low flow with and without preserved left ventricular ejection fraction (LVEF) on outcomes after transcatheter aortic valve replacement (TAVR). BACKGROUND: Prior studies have shown that patients with low flow, AVG, and LVEF have worse outcomes after TAVR. It is unclear whether low AVG and LVEF remain prognostic after adjusting for flow, and how the outcomes of patients with low flow with and without preserved LVEF compare after TAVR. The goal of this study was to provide insight into these open questions. METHODS: Data from 340 TAVR patients at Brigham and Women's Hospital from 2011 through 2015 were analyzed. Low flow was defined as stroke volume index (SVI) ≤35 mL/m2 , low AVG as mean gradient < 40 mmHg, and reduced LVEF as < 50%. RESULTS: Low flow was present in 96 (28.2%) patients, 48 (50.0%) of whom also had reduced LVEF. At 1 year, low flow was associated with increased mortality (21.9 vs 7.4%; P = 0.0002) and heart failure (HF) (20.8 vs 5.3%; P = 0.0113). Among patients with low flow, those with preserved LVEF had increased mortality (HR 5.17, 95% CI 2.73-9.80; P < 0.001) and HF (HR 7.69, 95% CI 3.86-15.31; P < 0.001). After adjusting for clinical factors, patients with low flow had increased mortality (HR 6.51, 95% CI 2.98-14.22; P < 0.001) and HF (HR 5.52, 95% CI 2.34-12.98; P < 0.001), while neither low AVG nor low LVEF were associated with increases in mortality or HF. CONCLUSIONS: In patients undergoing TAVR, low flow was an independent predictor of 1-year mortality and HF, and a stronger predictor than either low AVG or LVEF. Patients with low flow and preserved EF had increased mortality and HF at 1-year, while those with low flow and reduced EF had outcomes similar to patients with normal flow.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Stroke Volume , Transcatheter Aortic Valve Replacement , Ventricular Dysfunction, Left/physiopathology , Ventricular Function, Left , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Boston , Female , Heart Failure/mortality , Heart Failure/physiopathology , Hospital Mortality , Humans , Length of Stay , Male , Recovery of Function , Retrospective Studies , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/mortality
16.
J Heart Valve Dis ; 27(1): 9-16, 2018 Jan.
Article in English | MEDLINE | ID: mdl-30560594

ABSTRACT

BACKGROUND: A lower rate of permanent pacemaker (PPM) has been linked to a target aortic implantation height (AIH) >0.70, following transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 valve. Based on clinical experience, it was hypothesized that a higher AIH (≥0.85) would lower the rate of PPM implantation. METHODS: A total of 127 patients (66 females, 61 males; mean age 82 ± 8 years) underwent TAVR with the SAPIEN 3 valve between May 2015 and July 2016. AIH was defined as the proportion of the valve frame above the aortic annulus in the post-deployment aortogram. A target AIH (≥0.70) was achieved in 113 patients (89%). Cases were stratified into a High Implantation (HI) group (AIH ≥0.85; 33 patients) or a Standard Implantation (SI) group (AIH <0.85; 94 patients). RESULTS: The mean Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score of all patients was 6.4 ± 3.5%. Preoperative right bundle branch block (RBBB) was prevalent in 13% of SI patients, and in 18% of HI patients (p = 0.56). There were no significant differences in operative mortality (3.2% versus 0%), median length of stay (2 days versus 3 days) and incidence of moderate-to-severe paravalvular leak (3.2% versus 0%; all p >0.410) between SI and HI patients, respectively. Likewise, the incidence of new PPM did not differ between the two groups (12% in HI versus 13% in SI; p ≥0.99). The mean AIH was similar for patients with PPM implantation (0.80 ± 0.08) compared to those without (0.78 ± 0.06; p = 0.520). Preoperative RBBB was significantly associated with PPM implantation (odds ratio (OR) 10.1; p = 0.002), and patients who underwent PPM implantation had a higher operative mortality (12.5% versus 1%; p = 0.040). CONCLUSIONS: Among TAVR patients who received the SAPIEN 3 heart valve, a higher AIH (≥0.85) was not associated with a lower rate of PPM implantation or increased operative mortality. Prior RBBB was the only independent risk factor for new PPM implantation. Long-term follow up is crucial in determining the clinical significance of PPM implantation.


Subject(s)
Aortic Valve/surgery , Bundle-Branch Block/therapy , Heart Valve Diseases/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortography , Bundle-Branch Block/complications , Cardiac Pacing, Artificial , Female , Humans , Male
17.
Pediatr Cardiol ; 39(7): 1299-1307, 2018 Oct.
Article in English | MEDLINE | ID: mdl-29744657

ABSTRACT

This study assesses the characteristics of coronary obstructions that underwent transcatheter intervention in a pediatric catheterization laboratory, the procedural details, and patient outcomes. Acute cardiac failure due to coronary obstructions in children is rare. The role of catheter based intervention is largely unreported. Single center retrospective review between January 2000 and December 2016. Thirty-three patients (median age 2y/o [0-38], weighing 9.6 kg [2.2-91]) underwent 39 transcatheter interventions on 39 lesions, mainly left main coronary (16/39; 39%) and right coronary (9/39; 23%) arteries. Most patients had congenital heart disease (29/33; 88%). Cath indications included ventricular dysfunction (17), cardiac arrest (7), failure to wean from cardiopulmonary bypass (5), and other (4). Almost half (18/39; 46%) were performed on ECMO support. Obstructions were post-surgical (16; 4 with coronary manipulation), thrombotic (13; 5 < 30 days from cardiac surgery), and miscellaneous lesions (10). Interventions included 25 bare metal stents implanted in 22 lesions in 17 patients (mainly post-surgical lesions; 3 at Damus-Kaye-Stansel anastomosis), nine balloon angioplasty only, four lytic therapy ± mechanical disruption of thrombus, and four technical failures. There were no procedure-related deaths. Most patients survived to discharge or transplant (24/33; 73%). Six patients who received stents had follow-up catheterization (median 15.5 months [1-106]); all were without restenosis. Most coronary obstructions intervened upon in a pediatric cath lab were on young, critically ill patients with congenital heart disease secondary to surgical manipulation/injury or thrombosis. Transcatheter intervention should be considered a potential treatment strategy in this population.


Subject(s)
Cardiac Catheterization/methods , Coronary Occlusion/surgery , Coronary Vessels/surgery , Myocardial Reperfusion/methods , Adolescent , Adult , Cardiac Catheterization/adverse effects , Child , Child, Preschool , Coronary Occlusion/complications , Coronary Occlusion/mortality , Coronary Vessels/pathology , Heart Defects, Congenital/surgery , Humans , Infant , Infant, Newborn , Myocardial Reperfusion/adverse effects , Retrospective Studies , Stents , Survival Rate , Treatment Outcome , Young Adult
18.
Cardiology ; 137(1): 1-8, 2017.
Article in English | MEDLINE | ID: mdl-27925612

ABSTRACT

BACKGROUND: We aimed to compare periprocedural transesophageal echocardiography (TEE) with postprocedural transthoracic echocardiography (TTE) for the diagnosis of aortic regurgitation (AR). METHODS AND RESULTS: TEE and TTE images of 163 transcatheter aortic valve replacement (TAVR) patients (mean age 81 ± 8 years; 56% men) were reviewed separately and blinded to each other as well as to all clinical data. The median time between TEE during TAVR (TEE/TAVR) and TTE was 4 days (IQR 2-10 days). After TAVR, 48% of the patients had at least trace AR by TEE, 56% by angiography and 67% by TTE. The majority of AR was paravalvular (78%). More patients were classified with mild-to-moderate AR by TTE than by TEE (44 vs. 22%, p < 0.01). When examining the 46 patients with AR by TTE which was not at TEE/TAVR, both systolic and diastolic blood pressure (SBP and DBP) were significantly higher during TTE than during TEE (mean ΔSBP = 9 ± 4 mm Hg and mean ΔDBP = 6 ± 2 mm Hg, p < 0.01 for both). No differences in BP between TEE and TTE were found among patients with no AR or among those who had AR in both studies. At a median follow-up of 185 days (IQR 39-424 days), the overall mortality was 17%, but this was not associated with the presence of AR on TTE or TEE. CONCLUSIONS: Patients' hemodynamic conditions may result in underdiagnosis of paravalvular regurgitation in periprocedural TEE. Our findings suggest that a postprocedural evaluation for AR by TTE could serve as a reasonable alternative to TEE for the evaluation of AR.


Subject(s)
Aortic Valve Insufficiency/diagnostic imaging , Echocardiography/methods , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Aged , Aged, 80 and over , Aortic Valve Insufficiency/etiology , Boston , Echocardiography, Transesophageal , Female , Hemodynamics , Humans , Logistic Models , Male , Multivariate Analysis , Perioperative Care , Retrospective Studies , Severity of Illness Index , Treatment Outcome
19.
J Card Surg ; 30(6): 510-2, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25873004

ABSTRACT

A variety of access routes have been employed for transcatheter aortic valve replacement (TAVR). We report a TAVR case using the abdominal aorta as the direct access route when other approaches are not feasible.


Subject(s)
Aorta, Abdominal , Aortic Valve Stenosis/surgery , Transcatheter Aortic Valve Replacement/methods , Aged , Humans , Male , Risk , Severity of Illness Index , Treatment Outcome
20.
Cureus ; 16(4): e57977, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38738074

ABSTRACT

Crohn's disease is a chronic inflammatory bowel disease that primarily affects the terminal ileum and proximal colon. The exact cause is unknown but likely involves genetic factors, environmental triggers, and immune dysregulation. This case report delineates the choice of diagnostics for a 70-year-old patient presenting with symptoms indicative of small bowel obstruction. Initial assessments and imaging suggested a common clinical scenario, yet further investigation uncovered an unexpected diagnosis of Crohn's disease, a condition infrequently encountered in this age demographic.

SELECTION OF CITATIONS
SEARCH DETAIL