Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 186
Filter
Add more filters

Publication year range
1.
Catheter Cardiovasc Interv ; 95(6): 1076-1084, 2020 05 01.
Article in English | MEDLINE | ID: mdl-31489742

ABSTRACT

OBJECTIVES: To evaluate the long-term safety and efficacy of the novel combined sirolimus-eluting endothelial progenitor cell capture Combo stent (OrbusNeich, Fort Lauderdale, FL) at 5 years in the REMEDEE (Randomized study to Evaluate the safety and effectiveness of an abluMinal sirolimus coated bio-Engineered stEnt) trial. BACKGROUND: Drug-eluting stents have limited restenosis and reintervention but are complicated by late and very late thrombosis and accelerated neoatherosclerosis. Alternative or adjunctive technologies are needed to address these limitations. METHODS: A total of 183 patients with de novo lesions in native coronary arteries were randomized 2:1 to Combo (n = 124) or Taxus Liberté (n = 59). Primary endpoint was 9 month angiographic in-stent late lumen loss and the secondary endpoint was the occurrence of major adverse events (MACE) through 5-year follow-up. RESULTS: Compared with Taxus, after 5 years the Combo stent was associated with similar rates of MACE (18.3% vs. 16.9%, p = .89), cardiac death (0.8% vs. 5.1%, p = .07), myocardial infarction (4.1% vs. 3.4%, p = .81), target lesion (9.4% vs. 10.2%, p = .78), and target vessel revascularization (14.4% vs. 11.9%, p = .73). No cases of definite stent thrombosis were reported in the Combo group. The follow-up rate at 5 years was 97.7%. CONCLUSION: At 5-year follow-up, the Combo stent remained clinically safe and effective with an overall low rate of MACE comparable to Taxus.


Subject(s)
Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Drug-Eluting Stents , Endothelial Progenitor Cells/pathology , Percutaneous Coronary Intervention/instrumentation , Sirolimus/administration & dosage , Aged , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Artery Disease/pathology , Coronary Restenosis/etiology , Coronary Thrombosis/etiology , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prospective Studies , Risk Factors , Sirolimus/adverse effects , Time Factors , Treatment Outcome
2.
Herz ; 44(8): 676-683, 2019 Dec.
Article in German | MEDLINE | ID: mdl-31712870

ABSTRACT

After an unusually long period of time of 6 years, in August 2019 the updated version of the European Society of Cardiology (ESC) guidelines from 2013 on the management of stable coronary artery disease was published. The course of "stable" coronary artery disease is only assumed to be stable and pathologically is often progressive but initially goes unnoticed. In order to raise awareness for the progressive character of "stable" coronary artery disease, the term chronic coronary syndrome (CCS) was introduced. In this overview the various phenotypes of CCS are divided into three groups. 1) Suspected obstructive coronary artery disease: the emphasis here is on functional, noninvasive imaging diagnostics of ischemia and cardiac computed tomography (CT). These diagnostic options have become even more important in the light of the decreasing prevalence of coronary artery disease. 2) Known obstructive coronary artery disease: here there are many new practice-relevant recommendations, particularly in the field of pharmaceutical treatment with antithrombotic drugs. 3) Microvascular disease: in symptomatic patients the exclusion of epicardial coronary stenoses using invasive coronary angiography should not signify the end of the diagnostic procedure. Functional tests in the catheter laboratory should be initiated in order not to overlook a microvascular cause of the complaints and do an injustice to the patient.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Humans , Practice Guidelines as Topic
3.
Am Heart J ; 175: 56-65, 2016 May.
Article in English | MEDLINE | ID: mdl-27179724

ABSTRACT

BACKGROUND: We aimed to compare differences in risk and timing of recurrent ischemic events among patients with stable ischemic heart disease (SIHD), non-ST-segment elevation acute coronary syndrome (NSTE-ACS), and ST-segment elevation myocardial infarction (STEMI) undergoing percutaneous coronary intervention (PCI). METHODS: We performed an individual data pooled analysis of 5 randomized controlled all-comer trials including a total of 8,859 patients and investigated the risk and timing of recurrent ischemic events among patients with SIHD (n = 3,543), NSTE-ACS (n = 3,364), and STEMI (n = 1,952) throughout 2 years of follow-up. RESULTS: At 2 years, all-cause mortality was higher among patients with STEMI (6.4%) and NSTE-ACS (6.1%) compared with those with SIHD (4.2%) (STEMI vs SIHD: hazard ratio [HR] 1.40, 95% CI 1.09-1.78, P = .007; NSTE-ACS vs SIHD: 1.40, 95% CI 1.13-1.73, P = .002). In a landmark analysis, the risk of mortality among patients with STEMI compared with those with SIHD was confined to the first 30 days after PCI (HR 6.19, 95% CI 3.15-12.16, P < .001) but was similar between 30 days and 2 years (HR 1.00, 95% CI 0.76-1.33, P = .974) (Pinteraction < .001). Conversely, patients with NSTE-ACS had a higher risk of mortality compared with those with SIHD both within the first 30 days (HR 2.19, 95% CI 1.08-4.47, P = .031) and beyond (HR 1.34, 95% CI 1.07-1.67, P = .012) (Pinteraction < .001). A similar pattern in the differential timing of events was observed for cardiac death. Beyond 30 days, the risk of myocardial infarction was comparable in patients with STEMI and SIHD, whereas the risk in patients with NSTE-ACS was increased (HR 1.65, 95% CI 1.23-2.21, P = .001). CONCLUSION: Whereas patients with NSTE-ACS are at increased risk for death at any time after PCI, the mortality of STEMI patients is higher during the first 30 days after PCI but not thereafter compared with patients with SIHD.


Subject(s)
Angina, Stable , Long Term Adverse Effects , Non-ST Elevated Myocardial Infarction , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Aged , Angina, Stable/diagnosis , Angina, Stable/mortality , Angina, Stable/therapy , Female , Humans , Long Term Adverse Effects/diagnosis , Long Term Adverse Effects/etiology , Long Term Adverse Effects/mortality , Male , Middle Aged , Mortality , Non-ST Elevated Myocardial Infarction/diagnosis , Non-ST Elevated Myocardial Infarction/mortality , Non-ST Elevated Myocardial Infarction/therapy , Outcome and Process Assessment, Health Care , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/statistics & numerical data , Prognosis , Recurrence , Risk Assessment , ST Elevation Myocardial Infarction/diagnosis , ST Elevation Myocardial Infarction/mortality , ST Elevation Myocardial Infarction/therapy , Time Factors
4.
Catheter Cardiovasc Interv ; 87(2): 253-61, 2016 Feb 01.
Article in English | MEDLINE | ID: mdl-24323592

ABSTRACT

AIMS: To evaluate the rate of clinical events and bleeding risk according to age in patients undergoing percutaneous coronary intervention (PCI) with a new-generation drug-eluting stent (DES) enrolled in the RESOLUTE Global Clinical Program. METHODS: This study represents a pooled analysis of five trials included in the RESOLUTE program including 5,130 patients, of whom 1,675 (32.6%) were ≥70 years old (elderly patients). RESULTS: After adjusting for confounders, age ≥70 years was a significant predictor of high mortality at 30 days (0.6 vs. 0.1%, P = 0.017) and 2 years (7.2 vs. 2%, P < 0.001). No differences were seen with respect to acute myocardial infarction (MI) or target lesion and vessel revascularization rates between young and elderly patients. Bleeding rates were higher in the elderly throughout follow-up. In the elderly, 7 of the 27 (26%) patients with bleeding episodes died, with a median time between bleeding episode to death of 21 days. In the younger population, 1 patient of 17 with a bleeding episode died (400 days later). CONCLUSIONS: Elderly patients undergoing PCI with a new-generation DES have increased mortality and bleeding risk, with similar rates of acute MI and repeat revascularization. Bleeding risk was higher in the elderly and strongly related to death. Target lesion failure rates were not significantly different between the two age groups, suggesting that the Resolute zotarolimus-eluting stent (R-ZES) is effective for patients younger and older than 70 years of age. R-ZES may be recommended for elderly patients when PCI with a DES is identified as a suitable option.


Subject(s)
Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Drug-Eluting Stents , Percutaneous Coronary Intervention/instrumentation , Sirolimus/analogs & derivatives , Age Factors , Aged , Aged, 80 and over , Coronary Artery Disease/diagnosis , Coronary Artery Disease/mortality , Female , Hemorrhage/etiology , Humans , Kaplan-Meier Estimate , Logistic Models , Male , Middle Aged , Multivariate Analysis , Myocardial Infarction/etiology , Observational Studies as Topic , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Randomized Controlled Trials as Topic , Risk Factors , Sirolimus/administration & dosage , Time Factors , Treatment Outcome
5.
Catheter Cardiovasc Interv ; 85(6): 952-8, 2015 May.
Article in English | MEDLINE | ID: mdl-25689692

ABSTRACT

BACKGROUND: An increased body mass index (BMI) is associated with a high risk of cardiovascular disease and reduction in life expectancy. However, several studies reported improved clinical outcomes in obese patients treated for cardiovascular diseases. The aim of the present study is to investigate the impact of BMI on long-term clinical outcomes after implantation of zotarolimus eluting stents. METHODS: Individual patient data were pooled from the RESOLUTE Clinical Program comprising five trials worldwide. The study population was sorted according to BMI tertiles and clinical outcomes were evaluated at 2-year follow-up. RESULTS: Data from a total of 5,127 patients receiving the R-ZES were included in the present study. BMI tertiles were as follow: I tertile (≤ 25.95 kg/m(2) -Low or normal weight) 1,727 patients; II tertile (>25.95 ≤ 29.74 kg/m(2) -overweight) 1,695 patients, and III tertile (>29.74 kg/m(2) -obese) 1,705 patients. At 2-years follow-up no difference was found for patients with high BMI (III tertile) compared with patients with normal or low BMI (I tertile) in terms of target lesion failure (I-III tertile, HR [95% CI] = 0.89 [0.69, 1.14], P = 0.341; major adverse cardiac events (I-III tertile, HR [95% CI] = 0.90 [0.72, 1.14], P = 0.389; cardiac death (I-III tertile, HR [95% CI] = 1.20 [0.73, 1.99], P = 0.476); myocardial infarction (I-III tertile, HR [95% CI] = 0.86 [0.55, 1.35], P = 0.509; clinically-driven target lesion revascularization (I-III tertile, HR [95% CI] = 0.75 [0.53, 1.08], P = 0.123; definite or probable stent thrombosis (I-III tertile, HR [95% CI] = 0.98 [0.49, 1.99], P = 0.964. CONCLUSIONS: In the present study, the patients' body mass index was found to have no impact on long-term clinical outcomes after coronary artery interventions.


Subject(s)
Angioplasty, Balloon, Coronary/mortality , Body Mass Index , Coronary Restenosis/epidemiology , Coronary Stenosis/therapy , Drug-Eluting Stents , Aged , Angioplasty, Balloon, Coronary/methods , Cohort Studies , Coronary Angiography/methods , Coronary Restenosis/diagnostic imaging , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/mortality , Databases, Factual , Everolimus/pharmacology , Female , Follow-Up Studies , Humans , Internationality , Kaplan-Meier Estimate , Male , Middle Aged , Multivariate Analysis , Proportional Hazards Models , Retrospective Studies , Risk Assessment , Severity of Illness Index , Survival Rate , Time Factors , Treatment Outcome
6.
Eur Heart J ; 35(29): 1949-56, 2014 Aug 01.
Article in English | MEDLINE | ID: mdl-24510638

ABSTRACT

AIM: The optimal duration of dual antiplatelet therapy (DAPT) following the use of new generation drug-eluting stents is unknown. METHODS AND RESULTS: The association between DAPT interruption and the rates of stent thrombosis (ST) and cardiac death/target-vessel myocardial infarction (CD/TVMI) in patients receiving a Resolute zotarolimus-eluting stent (R-ZES) was analysed in 4896 patients from the pooled RESOLUTE clinical programme. Daily acetylsalicylate (ASA) and a thienopyridine for 6-12 months were prescribed. A DAPT interruption was defined as any interruption of ASA and/or a thienopyridine of >1 day; long interruptions were >14 days. Three groups were analysed: no interruption, interruption during the first month, and >1-12 months. There were 1069 (21.83%) patients with a DAPT interruption and 3827 patients with no interruption. Among the 166 patients in the 1-month interruption group, 6 definite/probable ST events occurred (3.61%; all long DAPT interruptions), and among the 903 patients in the >1-12 months (60% occurred between 6 and 12 months) interruption group, 1 ST event occurred (0.11%; 2-day DAPT interruption). Among patients with no DAPT interruption, 32 ST events occurred (0.84%). Rates of CD/TVMI were 6.84% in the 1-month long interruption group, 1.41% in the >1-12 months long interruption group, and 4.08% in patients on continuous DAPT. CONCLUSION: In a pooled population of patients receiving an R-ZES, DAPT interruptions within 1 month are associated with a high risk of adverse outcomes. Dual antiplatelet therapy interruptions between 1 and 12 months were associated with low rates of ST and adverse cardiac outcomes. Randomized clinical trials are needed to determine whether early temporary or permanent interruption of DAPT is truly safe. ClinicalTrials.gov Identifiers: NCT00617084; NCT00726453; NCT00752128; NCT00927940.


Subject(s)
Blood Vessel Prosthesis , Coronary Thrombosis/prevention & control , Drug-Eluting Stents , Fibrinolytic Agents/therapeutic use , Platelet Aggregation Inhibitors/therapeutic use , Prosthesis Failure/adverse effects , Withholding Treatment , Aspirin/therapeutic use , Clinical Trials as Topic , Clopidogrel , Death, Sudden, Cardiac/etiology , Female , Graft Occlusion, Vascular/prevention & control , Humans , Male , Middle Aged , Multicenter Studies as Topic , Myocardial Infarction/etiology , Prospective Studies , Sirolimus/analogs & derivatives , Sirolimus/therapeutic use , Ticlopidine/analogs & derivatives , Ticlopidine/therapeutic use , Time Factors , Treatment Outcome
7.
Catheter Cardiovasc Interv ; 84(1): 17-23, 2014 Jul 01.
Article in English | MEDLINE | ID: mdl-24659581

ABSTRACT

BACKGROUND: Drug eluting stents for the treatment of small vessel coronary artery disease have traditionally yielded inferior clinical outcomes compared to the use of DES in large vessels. The benefit of the second-generation Resolute zotarolimus-eluting stent (R-ZES) in small vessels was examined. METHODS: Two-year clinical outcomes from five combined R-ZES studies were compared between patients with small (reference vessel diameter [RVD] ≤2.5 mm; n = 1,956) and large (RVD >2.5 mm; n = 3174) vessels. RESULTS: Despite a higher incidence of comorbidities in the small vessel group, there was no significant difference in target lesion failure (TLF) (10.1% vs. 8.7%; P = 0.54) at 2 years. When the subgroup of patients with diabetes was examined (n = 1,553) there was no significant difference in 2-year TLF in small compared to large vessels (11.2% vs. 11.1%; P = 0.17). Similarly, within the small vessel cohort, no significant difference was seen regarding TLF at 2 years between people with and without diabetes (11.2% vs 9.6%; P = 0.28). CONCLUSION: When used for the treatment of small vessels, the R-ZES appears to provide acceptable clinical results at 2 years when compared to its performance in large vessels.


Subject(s)
Coronary Artery Disease/surgery , Coronary Vessels/surgery , Drug-Eluting Stents , Percutaneous Coronary Intervention/methods , Sirolimus/analogs & derivatives , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Prosthesis Design , Registries , Sirolimus/pharmacology , Time Factors , Treatment Outcome
8.
BMC Health Serv Res ; 14: 263, 2014 Jun 17.
Article in English | MEDLINE | ID: mdl-24938674

ABSTRACT

BACKGROUND: Cardiovascular diseases are the main cause of death worldwide, making their prevention a major health care challenge. In 2006, a German statutory health insurance company presented a novel individualised prevention programme (KardioPro), which focused on coronary heart disease (CHD) screening, risk factor assessment, early detection and secondary prevention. This study evaluates KardioPro in CHD risk subgroups, and analyses the cost-effectiveness of different individualised prevention strategies. METHODS: The CHD risk subgroups were assembled based on routine data from the statutory health insurance company, making use of a quasi-beta regression model for risk prediction. The control group was selected via propensity score matching based on logistic regression and an approximate nearest neighbour approach. The main outcome was cost-effectiveness. Effectiveness was measured as event-free time, and events were defined as myocardial infarction, stroke and death. Incremental cost-effectiveness ratios comparing participants with non-participants were calculated for each subgroup. To assess the uncertainty of results, a bootstrapping approach was applied. RESULTS: The cost-effectiveness of KardioPro in the group at high risk of CHD was € 20,901 per event-free year; in the medium-risk group, € 52,323 per event-free year; in the low-risk group, € 186,074 per event-free year; and in the group with known CHD, € 26,456 per event-free year. KardioPro was associated with a significant health gain but also a significant cost increase. However, statistical significance could not be shown for all subgroups. CONCLUSION: The cost-effectiveness of KardioPro differs substantially according to the group being targeted. Depending on the willingness-to-pay, it may be reasonable to only offer KardioPro to patients at high risk of further cardiovascular events. This high-risk group could be identified from routine statutory health insurance data. However, the long-term consequences of KardioPro still need to be evaluated.


Subject(s)
Cardiovascular Diseases/prevention & control , Insurance Carriers , Primary Prevention/economics , Adult , Cost-Benefit Analysis , Early Diagnosis , Female , Germany , Humans , Male , Mass Screening/economics , Program Evaluation , Propensity Score , Risk Assessment/economics , Secondary Prevention/economics
9.
N Engl J Med ; 363(2): 136-46, 2010 Jul 08.
Article in English | MEDLINE | ID: mdl-20554978

ABSTRACT

BACKGROUND: New-generation coronary stents that release zotarolimus or everolimus have been shown to reduce the risk of restenosis. However, it is unclear whether there are differences in efficacy and safety between the two types of stents on the basis of prospectively adjudicated end points endorsed by the Food and Drug Administration. METHODS: In this multicenter, noninferiority trial with minimal exclusion criteria, we randomly assigned 2292 patients to undergo treatment with coronary stents releasing either zotarolimus or everolimus. Twenty percent of patients were randomly selected for repeat angiography at 13 months. The primary end point was target-lesion failure, defined as a composite of death from cardiac causes, any myocardial infarction (not clearly attributable to a nontarget vessel), or clinically indicated target-lesion revascularization within 12 months. The secondary angiographic end point was the extent of in-stent stenosis at 13 months. RESULTS: At least one off-label criterion for stent placement was present in 66% of patients. The zotarolimus-eluting stent was noninferior to the everolimus-eluting stent with respect to the primary end point, which occurred in 8.2% and 8.3% of patients, respectively (P<0.001 for noninferiority). There were no significant between-group differences in the rate of death from cardiac causes, any myocardial infarction, or revascularization. The rate of stent thrombosis was 2.3% in the zotarolimus-stent group and 1.5% in the everolimus-stent group (P=0.17). The zotarolimus-eluting stent was also noninferior regarding the degree (+/-SD) of in-stent stenosis (21.65+/-14.42% for zotarolimus vs. 19.76+/-14.64% for everolimus, P=0.04 for noninferiority). In-stent late lumen loss was 0.27+/-0.43 mm in the zotarolimus-stent group versus 0.19+/-0.40 mm in the everolimus-stent group (P=0.08). There were no significant between-group differences in the rate of adverse events. CONCLUSIONS: At 13 months, the new-generation zotarolimus-eluting stent was found to be noninferior to the everolimus-eluting stent in a population of patients who had minimal exclusion criteria. (ClinicalTrials.gov number, NCT00617084.)


Subject(s)
Coronary Disease/therapy , Drug-Eluting Stents , Myocardial Infarction/therapy , Sirolimus/analogs & derivatives , Aged , Coronary Angiography , Coronary Disease/mortality , Coronary Restenosis , Drug-Eluting Stents/adverse effects , Everolimus , Female , Humans , Intention to Treat Analysis , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Infarction/epidemiology , Prosthesis Design , Retreatment , Sirolimus/administration & dosage , Treatment Failure
10.
Catheter Cardiovasc Interv ; 82(2): 184-90, 2013 Aug 01.
Article in English | MEDLINE | ID: mdl-23008177

ABSTRACT

BACKGROUND: Primary percutaneous coronary intervention (PCI) improves survival compared with thrombolytic therapy in ST-segment elevation myocardial infarction (STEMI), with much of the benefit attributable to greater rates of normal epicardial and myocardial perfusion resulting in enhanced myocardial salvage. However, reduced tissue reperfusion after primary PCI may occur from distal thromboemboli with capillary plugging. The MGuard stent consists of a balloon-expandable metallic scaffold with mesh sleeve fibers of polyethylene terephthalate attached to its outer surface to trap friable debris/thrombi and reduce distal embolization. The MGuard for Acute ST Elevation Reperfusion (MASTER) trial has been designed to evaluate the MGuard stent in patients with STEMI. STUDY DESIGN: The MASTER trial is a prospective, multicenter, randomized study designed to compare the incidence of complete (=70%) ST-segment resolution with PCI using bare metal or drug-eluting stents (the control arm) versus PCI with the MGuard stent, measured 60 to 90 min after the last angiogram (primary endpoint). Secondary endpoints include the rates of TIMI flow and myocardial blush, and clinical outcomes through 1-year follow-up. The study has enrolled 432 patients with STEMI undergoing primary or rescue angioplasty within 12 hr of symptom onset and includes substudies with cardiac magnetic resonance imaging and quantitative coronary angiography to evaluate infarct size, microvascular obstruction, and angiographic restenosis. CONCLUSIONS: Distal embolization is common during primary PCI and results in reduced myocardial perfusion and lack of reduction of infarct size. The MASTER trial is a prospective, randomized trial designed to assess the potential of the novel MGuard stent with protective mesh net to reduce embolization and enhance myocardial reperfusion compared with routine PCI in the setting of STEMI.


Subject(s)
Embolic Protection Devices , Myocardial Infarction/therapy , Percutaneous Coronary Intervention/instrumentation , Prosthesis Design , Stents , Brazil , Clinical Protocols , Coronary Angiography , Coronary Restenosis/etiology , Coronary Restenosis/prevention & control , Drug-Eluting Stents , Europe , Humans , Magnetic Resonance Imaging , Metals , Myocardial Infarction/diagnosis , Myocardial Infarction/mortality , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prospective Studies , Research Design , Thromboembolism/etiology , Thromboembolism/prevention & control , Time Factors , Treatment Outcome , United States
11.
Nuklearmedizin ; 62(4): 235-243, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37268009

ABSTRACT

AIM: This paper presents the results of the 9th survey of myocardial perfusion SPECT (MPS) from the reporting year 2021. METHODS: 218 questionnaires (131 practices (PR), 58 hospitals (HO), 29 university hospitals (UH)) were evaluated. Results of the last survey 2018 are set in squared brackets. RESULTS: MPS data from a total of 133,057 [145,930] patients (-8.8%) with 131,868 [143,707] stress and 106,546 [121,899] rest MPS were analysed. A comparison with official data revealed that 54% all MPS were recorded. From 2018 to 2021, official data showed a every year an increase in MPS numbers. On average, 610 [502] MPS patients (+22%) were examined in each department. 74% [69%] of the responders reported an increase or no changes in their MPS patient numbers. Ambulatory care cardiologists represented as always, the mayor referral group (68% [69%]). For the first time, pharmacological stress was more frequently applied than ergometry (42% [51]). Regadenoson was mostly used. The use of the different protocols remained nearly unchanged. Two-day protocols were predominantly applied (49% [48%]). A shift from multi-headed cameras (58% [72%]) to SPECT-CT systems (24% [17%]) was found. Attenuation correction was performed in 33% [26%] of all MPS. 88% [86%] of all stress, 88% [87%] of all rest and 87% [83%] of all stress and rest MPS were acquired as gated SPECT. 72% [67%] of all departments performed scoring by default. The number of departments without scoring decreased to 13% [16%]. CONCLUSIONS: The MPS Study 2021 shows that the long-term positive development of MPS imaging in Germany is continuing. The COVID-19 pandemia did not change this trend. The procedural and technical details of MPS imaging reveal a high level of guideline conformity.


Subject(s)
COVID-19 , Myocardial Perfusion Imaging , Humans , Myocardial Perfusion Imaging/methods , Tomography, Emission-Computed, Single-Photon , Surveys and Questionnaires , Hospitals, University , Germany/epidemiology , Perfusion
12.
Lancet ; 377(9773): 1241-7, 2011 Apr 09.
Article in English | MEDLINE | ID: mdl-21459430

ABSTRACT

BACKGROUND: In the RESOLUTE All Comers trial, the Resolute zotarolimus-eluting stent was non-inferior to the Xience V everolimus-eluting stent for the primary stent-related endpoint of target lesion failure (cardiac death, target vessel myocardial infarction, and ischaemia-driven target lesion revascularisation) at 1 year. However, data for long-term safety and efficacy from randomised studies of new generation drug-eluting coronary stents in patients treated in routine clinical practice are scarce. We report the prespecified 2-year clinical outcomes from the RESOLUTE All Comers trial. METHODS: In 2008, patients with at least one coronary lesion 2.25-4.0 mm in diameter, with greater than 50% stenosis, were randomly assigned to a Resolute zotarolimus-eluting stent or a Xience V everolimus-eluting stent at 17 centres in Europe and Israel. Randomisation was by an interactive voice response system stratified by centre. Study investigators were not masked to treatment allocation; but those who did data management and analysis, and patients were masked. There were no restrictions as to the number of vessels or lesions treated, or the number of stents implanted. We assessed prespecified safety and efficacy outcomes at 2 years with specific focus on patient-related composite (all death, all myocardial infarction, all revascularisation) and stent-related composite outcomes. Analyses were by intention to treat. This study is registered with ClinicalTrials.gov, number NCT00617084. FINDINGS: 1140 patients were assigned to the zotarolimus-eluting stent and 1152 to the everolimus-eluting stent; 1121 and 1128 patients, respectively, completed 2-year follow-up. The patient-related outcome (231 [20.6%] zotarolimus vs 231 [20.5%] everolimus; difference 0.1%, 95% CI-3.2 to 3.5; p=0.958) and stent-related outcome (126 [11.2%] vs 121 [10.7%]; difference 0.5%, -2.1 to 3.1; p=0.736) did not differ between groups, although rates of the stent-related outcome were substantially lower than were those for the patient-related outcome. Three patients in each group (0.3%) had very late (after 1 year) stent thrombosis. INTERPRETATION: Similar safety and efficacy outcomes were sustained between two new generation drug-eluting stents at 2-year follow-up. The greater number of patient-related than stent-related events in patients with complex clinical and lesion characteristics emphasises that during long-term follow-up, the optimisation of secondary prevention is at least as important as the selection of which new generation drug-eluting stent to implant in a specific lesion. FUNDING: Medtronic (USA).


Subject(s)
Coronary Artery Disease/therapy , Coronary Restenosis/prevention & control , Death, Sudden, Cardiac/prevention & control , Drug-Eluting Stents , Myocardial Infarction/prevention & control , Sirolimus/analogs & derivatives , Adult , Aged , Confounding Factors, Epidemiologic , Coronary Angiography , Coronary Restenosis/diagnostic imaging , Europe , Everolimus , Female , Follow-Up Studies , Humans , Immunosuppressive Agents/therapeutic use , Israel , Male , Middle Aged , Myocardial Revascularization/statistics & numerical data , Prospective Studies , Secondary Prevention/methods , Sirolimus/therapeutic use , Treatment Outcome
13.
Clin Chem ; 58(1): 200-8, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22156668

ABSTRACT

BACKGROUND: Measuring circulating cardiac troponin using novel sensitive assays has revealed that even minute elevations are associated with increased mortality in patients with coronary artery disease or even in the general population. Less well defined, however, is the incremental value of measuring circulating cardiac troponin I (cTnI) by a sensitive assay for risk assessment in primary prevention. METHODS: We measured circulating concentrations of cTnI, N-terminal pro-B-type natriuretic peptide (NT-proBNP), and high-sensitivity C-reactive protein (hsCRP) in 5388 individuals free of known cardiovascular disease recruited into the DETECT study, a prospective longitudinal population-based cohort study. We determined the prognostic implications for incident major adverse cardiovascular events (MACE) during 5 years of follow-up. RESULTS: Circulating cTnI was detectable in 19% of the subjects. Increased cTnI concentrations were associated with established risk factors for atherosclerosis and demonstrated a graded relationship with all-cause mortality and incident MACE during 5-year follow-up. A single measurement of cTnI significantly improved risk prediction over established risk factors, and also added prognostic information, when adjusted for serum concentrations of NT-proBNP and hsCRP. CONCLUSIONS: Minute increases in cTnI are associated with increased mortality and incident MACE in a large primary prevention cohort and, thus, identify contributors to cardiovascular risk not fully captured by traditional risk factor assessment.


Subject(s)
Cardiovascular Diseases/diagnosis , Primary Prevention , Troponin I/blood , Aged , Biomarkers/blood , C-Reactive Protein/analysis , Cardiovascular Diseases/mortality , Coronary Disease/diagnosis , Coronary Disease/mortality , Female , Humans , Male , Middle Aged , Mortality , Natriuretic Peptide, Brain/blood , Peptide Fragments/blood , Prognosis , Proportional Hazards Models , Prospective Studies , Protein Precursors/blood , Risk Assessment , Risk Factors , Sensitivity and Specificity
14.
Catheter Cardiovasc Interv ; 79(2): 243-52, 2012 Feb 01.
Article in English | MEDLINE | ID: mdl-21542121

ABSTRACT

OBJECTIVE: We investigated the relation between duration of dual antiplatelet therapy (DAPT) and clinical outcomes up to 12 months after Genous™ endothelial progenitor cell capturing R stent™ placement in patients from the e-HEALING registry. BACKGROUND: Cessation of (DAPT) has been shown to be associated with the occurrence of stent thrombosis (ST). After Genous placement, 1 month of DAPT is recommended. METHODS: Patients were analyzed according to continuation or discontinuation of DAPT at a 30-day and 6-month landmark, excluding patients with events before the landmark. Each landmark was a new baseline, and outcomes were followed up to 12 months after stenting. The main outcome for our current analysis was target vessel failure (TVF), defined as target vessel-related cardiac death or myocardial infarction and target vessel revascularization. Secondary outcomes included ST. (Un)adjusted hazard ratios (HR) for TVF were calculated with Cox regression. RESULTS: No difference was observed in the incidence of TVF [HR: 1.03; 95% confidence intervals (CI): 0.65-1.65, P = 0.89] in patients continuing DAPT (n = 4,249) at 30 days versus patients stopped (n = 309), and HR: 0.82 (95% CI: 0.55-1.23, P = 0.34) in patients continuing DAPT (n = 2,654) at 6 months versus patients stopped [n = 1,408] DAPT). Furthermore, no differences were observed in ST. Even after addition of identified independent predictors for TVF, adjusted TVF hazards were comparable. CONCLUSIONS: In a post-hoc analysis of e-HEALING, duration of DAPT was not associated with the occurrence of the outcomes TVF or ST. The Genous stent may be an attractive treatment especially in patients at increased risk for (temporary) cessation of DAPT or bleeding.


Subject(s)
Coronary Artery Disease/therapy , Drug-Eluting Stents , Myocardial Revascularization/methods , Platelet Aggregation Inhibitors/therapeutic use , Product Surveillance, Postmarketing/statistics & numerical data , Aged , Bioengineering , Drug Therapy, Combination , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Prosthesis Design , Registries , Treatment Outcome
15.
J Interv Cardiol ; 25(4): 344-52, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22409587

ABSTRACT

BACKGROUND: Controversy exists about the impact of treating bifurcations on overall outcome of coronary interventions using drug-eluting stents (DES). We sought to investigate 1-year outcome of the treatment of bifurcation lesions using DES in a large "real-world" cohort. METHODS AND RESULTS: Among 5,126 patients enrolled in phase I of the multicenter German Drug-Eluting Stent Registry, 814 (16%) were treated for a bifurcation lesion. Patients with bifurcations were compared to those without bifurcations in terms of baseline characteristics, major adverse cardiac and cerebrovascular events (MACCE) and target vessel revascularization (TVR) at 1 year. Usage of sirolimus-eluting stents (SES) versus paclitaxel-eluting stents (PES) was also evaluated. In total, 1,021 and 5,189 stents were implanted in the bifurcation (1.25 stents/patient) and nonbifurcation (1.2 stents/patient) group, respectively, but 64.5% of bifurcation lesions were treated with a single stent. More complex lesion and procedural characteristics were observed in the bifurcation group. However, there was no difference in 1-year MACCE rates (a composite of death, myocardial infarction, and stroke) between the bifurcation group and nonbifurcation group (8.1% vs. 8.3%, P = 0.85). Rates of TVR (11.2% vs. 10.8%, P = 0.75) and Academic Research Consoritum-defined definite stent thrombosis (0.9% vs. 0.8%, P = 0.67) were also comparable. MACCE and TVR rates remained similar after adjustment for differences in baseline characteristics. MACCE and TVR in SES patients were 7.2% and 12.6% versus 8.7% and 10.2% in PES patients (P = 0.46 and P = 0.30, respectively). CONCLUSION: In this large multicenter registry, treatment of bifurcation lesions with DES appears effective and safe. The presence of bifurcations did not affect 1-year outcomes after DES implantation. The outcomes for SES and PES were similar.


Subject(s)
Coronary Artery Disease/therapy , Drug-Eluting Stents , Paclitaxel/therapeutic use , Sirolimus/therapeutic use , Aged , Antineoplastic Agents, Phytogenic/therapeutic use , Cohort Studies , Female , Follow-Up Studies , Germany , Humans , Immunosuppressive Agents/therapeutic use , Male , Middle Aged , Percutaneous Coronary Intervention , Prospective Studies , Registries , Treatment Outcome
16.
Heart Vessels ; 27(4): 360-9, 2012 Jul.
Article in English | MEDLINE | ID: mdl-21725668

ABSTRACT

The National Institute for Clinical Excellence (NICE) guidelines recommend the use of bare-metal stents (BMS) in non-complex lesions with a low risk of restenosis (diameter ≥3 mm and lesion length ≤15 mm) and the use of drug-eluting stents (DES) in more complex lesions with a high risk of restenosis (diameter <3.0 mm or lesion length >15 mm). However, the guidelines were created based on studies evaluating BMS and DES only. We performed an analysis of patients undergoing non-urgent percutaneous coronary intervention with the novel endothelial cell capturing stent (ECS). The ECS is coated with CD34(+) antibodies that attract circulating endothelial progenitor cells to the stent surface, thereby accelerating the endothelialization of the stented area. We analyzed all patients enrolled in the worldwide e-HEALING registry that met the NICE criteria for either low-risk or high-risk lesions and were treated with ≥1 ECS. The main study outcome was target vessel failure (TVF) at 12-month follow-up, defined as the composite of cardiac death or MI and target vessel revascularization (TVR). A total of 4,241 patients were assessed in the current analysis. At 12-month follow-up, TVF occurred in 7.0% of the patients with low-risk lesions and in 8.8% of the patients with high-risk lesions (p = 0.045). When evaluating the diabetic patients versus the non-diabetic patients per risk group, no significant differences were found in TVF, MI or TVR in either risk group. The ECS shows good clinical outcomes in lesions carrying either a high or a low risk of restenosis according to the NICE guidelines with comparable rates of cardiac death, myocardial infarction, and stent thrombosis. The TVF rate with ECS was slightly higher in patients with high-risk lesions, driven by higher clinically driven TLR. The risk of restenosis with ECS in patients carrying high-risk lesions needs to be carefully considered relative to other risks associated with DES. Furthermore, the presence of diabetes mellitus did not influence the incidence of TVF in either risk group.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/standards , Coronary Restenosis/prevention & control , Coronary Stenosis/therapy , Coronary Vessels/pathology , Endothelial Cells/pathology , Government Agencies/standards , Stem Cells/pathology , Stents/standards , Aged , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/mortality , Antibodies/administration & dosage , Antigens, CD34/immunology , Coated Materials, Biocompatible/standards , Coronary Restenosis/etiology , Coronary Restenosis/mortality , Coronary Restenosis/pathology , Coronary Stenosis/mortality , Coronary Stenosis/pathology , Coronary Vessels/immunology , Endothelial Cells/immunology , Female , Guideline Adherence/standards , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Infarction/etiology , Neointima , Patient Selection , Practice Guidelines as Topic/standards , Product Surveillance, Postmarketing , Proportional Hazards Models , Prosthesis Design , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Stem Cells/immunology , Thrombosis/etiology , Time Factors , Treatment Outcome
17.
Eur Heart J ; 32(11): 1398-408, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21345854

ABSTRACT

AIMS: The applicability of currently available risk prediction models for patients undergoing percutaneous coronary interventions (PCIs) is limited. We aimed to develop a model for the prediction of in-hospital mortality after PCI that is based on contemporary and representative data from a European perspective. METHODS AND RESULTS: Our analyses are based on the Euro Heart Survey of PCIs, which contains information on 46 064 consecutive patients who underwent PCI for different indications in 176 participating European centres during 2005-08. Patients were randomly divided into a training (n = 23 032) and a validation (n = 23 032) set with similar characteristics. In these sets, 339 (1.5%) and 305 (1.3%) patients died during hospitalization, respectively. On the basis of the training set, a logistic model was constructed that related 16 independent patient or lesion characteristics with mortality, including PCI indication, advanced age, haemodynamic instability, multivessel disease, and proximal LAD disease. In both the training and validation data sets, the model had a good performance in terms of discrimination (C-index 0.91 and 0.90, respectively) and calibration (Hosmer-Lemeshow P-value 0.39 and 0.18, respectively). CONCLUSION: In-hospital mortality in PCI patients was well predicted by a risk score that contains 16 factors. The score has strong applicability for European practices.


Subject(s)
Angioplasty, Balloon, Coronary/mortality , Myocardial Infarction/therapy , Severity of Illness Index , Aged , Europe , Female , Hospital Mortality , Humans , Male , Middle Aged , Myocardial Infarction/mortality , Risk Assessment
18.
Eur Heart J ; 32(19): 2454-63, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21659439

ABSTRACT

AIMS: To compare the tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent (ZES) vs. a fluoropolymer-coated everolimus-eluting stent (EES) at 13 months, using optical coherence tomography (OCT) in an 'all-comers' population of patients, in order to clarify the mechanism of eventual differences in the biocompatibility and thrombogenicity of the devices. METHODS AND RESULTS: Patients randomized to angiographic follow-up in the RESOLUTE All Comers trial (NCT00617084) at pre-specified OCT sites underwent OCT follow-up at 13 months. Tissue coverage and apposition were assessed strut by strut, and the results in both treatment groups were compared using multilevel logistic or linear regression, as appropriate, with clustering at three different levels: patient, lesion, and stent. Fifty-eight patients (30 ZES and 28 EES), 72 lesions, 107 stents, and 23 197 struts were analysed. Eight hundred and eighty-seven and 654 uncovered struts (7.4 and 5.8%, P= 0.378), and 216 and 161 malapposed struts (1.8 and 1.4%, P= 0.569) were found in the ZES and EES groups, respectively. The mean thickness of coverage was 116 ± 99 µm in ZES and 142 ± 113 µm in EES (P= 0.466). No differences in per cent neointimal volume obstruction (12.5 ± 7.9 vs. 15.0 ± 10.7%) or other areas-volumetric parameters were found between ZES and EES, respectively. CONCLUSION: No significant differences in tissue coverage, malapposition, or lumen/stent areas and volumes were detected by OCT between the hydrophilic polymer-coated ZES and the fluoropolymer-coated EES at 13-month follow-up.


Subject(s)
Coronary Stenosis/therapy , Drug-Eluting Stents , Sirolimus/analogs & derivatives , Tubulin Modulators/administration & dosage , Aged , Everolimus , Female , Follow-Up Studies , Humans , Male , Middle Aged , Polymers , Prospective Studies , Sirolimus/administration & dosage , Tomography, Optical Coherence , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL