Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 4559-4562, 2020 07.
Article in English | MEDLINE | ID: mdl-33019008

ABSTRACT

Wearable devices have been showing promising results in a large range of applications: since industry, to entertainment and, in particular, healthcare. In the scope of movement disorders, wearable devices are being widely implemented for motor symptoms objective assessment. Currently, clinicians evaluate patients' motor symptoms resorting to subjective scales and visual perception, such as in Parkinson's Disease. The possibility to make use of wearable devices to quantify this disorder motor symptoms would bring an accurate follow-up on the disease progression, leading to more efficient treatments.Here we present a novel textile embedded low-power wearable device capable to be used in any scenario of movement disorders assessment due to its seamless, comfort and versatility. Regarding our research, it has already improved the setup of a wrist rigidity quantification system for Parkinson's Disease patients: the iHandU system. The wearable comprises a hardware sensing unit integrated in a textile band with an innovative design assuring higher comfort and easiness-to-use in movement disorders assessment. It enables to collect inertial data (9-axis) and has the possibility to integrate two analog sensors. A web platform was developed for data reading, visualization and recording. To ensure inertial data reliability, validation tests for the accelerometer and gyroscope sensors were conducted by comparison with its theoretical behavior, obtaining very good results.


Subject(s)
Parkinson Disease , Wearable Electronic Devices , Humans , Parkinson Disease/therapy , Reproducibility of Results , Textiles , Wrist Joint
2.
Int J Med Inform ; 129: 60-68, 2019 09.
Article in English | MEDLINE | ID: mdl-31445290

ABSTRACT

It is known that excessive levels of occupational stress affect professionals' technical and non-technical skills and surgeons are no exception. However, very few studies address this problem in neurosurgeons. A system for monitoring cardiovascular strain and autonomic imbalance during intracranial aneurysm procedures is proposed in order to obtain overall cardiac measures from those procedures. Additionally, this study also allows to detect stressful events and compare their impact with the surgeon's own appraisal. Linear and nonlinear heart rate variability (HRV) features were extracted from surgeon's electrocardiogram (ECG) signal using wearable ECG monitors and mobile technology during 10 intracranial aneurysm surgeries with two surgeons. Stress appraisal and cognitive workload were assessed using self-report measures. Findings suggest that the surgeon associated to the main role during the clipping can be exposed to high levels of stress, especially if a rupture occurs (pNN20 = 0%), while the assistant surgeon tends to experience mental fatigue. Cognitive workload scores of one of the surgeons were negatively correlated with AVNN, SDNN, pNN20, pNN50, 1 V, 2 L V, SD2 and CVI measures. Cognitive workload was positively related with stress appraisal, suggesting that more mentally demanding procedures are also assessed as more stressful. Finally, pNN20 seems to better mirror behavior during stress moments than pNN50. Additionally, a sympathovagal excitation occurs in one of the professionals after changing to main role. The present methodology shows potential for the identification of harmful events. This work may be of importance for the design of effective interventions in order to reduce surgeons stress levels. Furthermore, this approach can be applied to other professions.


Subject(s)
Stress, Physiological , Wearable Electronic Devices , Adult , Cooperative Behavior , Electrocardiography , Humans , Male , Middle Aged , Monitoring, Physiologic/methods , Surgeons , Workload
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 5494-5497, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31947098

ABSTRACT

Transthyretin Familial Amyloid Polyneuropathy (TTR-FAP) is a rare and disabling neurological disorder caused by a mutation of the transthyretin gene. One of the disease's characteristics that mostly affects patients' quality of life is its influence on locomotion, with a variable evolution timing. Quantitative motion analysis is useful for assessing motor function, including gait, in diseases affecting movement. However, it is still an evolving field, especially in TTR-FAP, with only a few available studies. A single markerless RGB-D camera provides 3-D body joint data in a less expensive, more portable and less intrusive way than reference multi-camera marker-based systems for motion capture. In this contribution, we investigate if a gait analysis system based on a RGB-D camera can be used to detect gait changes over time for a given TTR-FAP patient. 3-D data provided by that system and a reference system were acquired from six TTR-FAP patients, while performing a simple gait task, once and then a year and a half later. For each gait cycle and system, several gait parameters were computed. For each patient, we investigated if the RBG-D camera system is able to detect the existence or not of statistically significant differences between the two different acquisitions (separated by 1.5 years of disease evolution), in a similar way to the reference system. The obtained results show the potential of using a single RGB-D camera to detect relevant changes in spatiotemporal gait parameters (e.g., stride duration and stride length), during TTR-FAP patient follow-up.


Subject(s)
Amyloid Neuropathies, Familial , Gait Analysis , Amyloid Neuropathies, Familial/diagnosis , Gait , Humans , Prealbumin , Quality of Life
4.
Stud Health Technol Inform ; 247: 46-50, 2018.
Article in English | MEDLINE | ID: mdl-29677920

ABSTRACT

Epilepsy diagnosis is typically performed through 2Dvideo-EEG monitoring, relying on the viewer's subjective interpretation of the patient's movements of interest. Several attempts at quantifying seizure movements have been performed in the past using 2D marker-based approaches, which have several drawbacks for the clinical routine (e.g. occlusions, lack of precision, and discomfort for the patient). These drawbacks are overcome with a 3D markerless approach. Recently, we published the development of a single-bed 3Dvideo-EEG system using a single RGB-D camera (Kinect v1). In this contribution, we describe how we expanded the previous single-bed system to a multi-bed departmental one that has been managing 6.61 Terabytes per day since March 2016. Our unique dataset collected so far includes 2.13 Terabytes of multimedia data, corresponding to 278 3Dvideo-EEG seizures from 111 patients. To the best of the authors' knowledge, this system is unique and has the potential of being spread to multiple EMUs around the world for the benefit of a greater number of patients.


Subject(s)
Electroencephalography , Epilepsy/diagnosis , Humans , Monitoring, Physiologic , Motion , Movement
5.
Neuroradiol J ; 30(4): 318-323, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28632041

ABSTRACT

Background and purpose We evaluated two methods to identify mesial temporal sclerosis (MTS): visual inspection by experienced epilepsy neuroradiologists based on structural magnetic resonance imaging sequences and automated hippocampal volumetry provided by a processing pipeline based on the FMRIB Software Library. Methods This retrospective study included patients from the epilepsy monitoring unit database of our institution. All patients underwent brain magnetic resonance imaging in 1.5T and 3T scanners with protocols that included thin coronal T2, T1 and fluid-attenuated inversion recovery and isometric T1 acquisitions. Two neuroradiologists with experience in epilepsy and blinded to clinical data evaluated magnetic resonance images for the diagnosis of MTS. The diagnosis of MTS based on an automated method included the calculation of a volumetric asymmetry index between the two hippocampi of each patient and a threshold value to define the presence of MTS obtained through statistical tests (receiver operating characteristics curve). Hippocampi were segmented for volumetric quantification using the FIRST tool and fslstats from the FMRIB Software Library. Results The final cohort included 19 patients with unilateral MTS (14 left side): 14 women and a mean age of 43.4 ± 10.4 years. Neuroradiologists had a sensitivity of 100% and specificity of 73.3% to detect MTS (gold standard, k = 0.755). Automated hippocampal volumetry had a sensitivity of 84.2% and specificity of 86.7% (k = 0.704). Combined, these methods had a sensitivity of 84.2% and a specificity of 100% (k = 0.825). Conclusions Automated volumetry of the hippocampus could play an important role in temporal lobe epilepsy evaluation, namely on confirmation of unilateral MTS diagnosis in patients with radiological suggestive findings.


Subject(s)
Epilepsy, Temporal Lobe/diagnostic imaging , Epilepsy, Temporal Lobe/pathology , Hippocampus/diagnostic imaging , Hippocampus/pathology , Magnetic Resonance Imaging/methods , Adult , Diagnosis, Differential , Female , Humans , Male , Retrospective Studies , Sclerosis , Sensitivity and Specificity
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 1368-1371, 2017 Jul.
Article in English | MEDLINE | ID: mdl-29060131

ABSTRACT

Transthyretin Familial Amyloid Polyneuropathy (TTR-FAP) is a rare neurological disease caused by a genetic mutation with a variable presentation and consequent challenging diagnosis, complex follow-up and treatment. At this moment, this condition has no cure and treatment options are under development. One of the disease's implications is a definite and progressive motor impairment that from the early stages compromises walking ability and daily life activities. The detection of this impairment is key for the disease onset diagnosis. With the goal of improving diagnosis of the symptoms and patients' quality of life, the authors have assessed the gait characteristics of subjects suffering from this condition. This contribution shows the results of a preliminary study, using a non-intrusive, markerless vision-based gait analysis tool. To the best of our knowledge, the reported results constitute the first gait analysis data of TTR-FAP mutation carriers.


Subject(s)
Amyloid Neuropathies, Familial , Gait , Humans , Mutation , Prealbumin , Quality of Life
7.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 5809-5812, 2016 Aug.
Article in English | MEDLINE | ID: mdl-28269575

ABSTRACT

Intraoperative evaluation of the efficacy of Deep Brain Stimulation includes evaluation of the effect on rigidity. A subjective semi-quantitative scale is used, dependent on the examiner perception and experience. A system was proposed previously, aiming to tackle this subjectivity, using quantitative data and providing real-time feedback of the computed rigidity reduction, hence supporting the physician decision. This system comprised of a gyroscope-based motion sensor in a textile band, placed in the patients hand, which communicated its measurements to a laptop. The latter computed a signal descriptor from the angular velocity of the hand during wrist flexion in DBS surgery. The first approach relied on using a general rigidity reduction model, regardless of the initial severity of the symptom. Thus, to enhance the performance of the previously presented system, we aimed to develop models for high and low baseline rigidity, according to the examiner assessment before any stimulation. This would allow a more patient-oriented approach. Additionally, usability was improved by having in situ processing in a smartphone, instead of a computer. Such system has shown to be reliable, presenting an accuracy of 82.0% and a mean error of 3.4%. Relatively to previous results, the performance was similar, further supporting the importance of considering the cogwheel rigidity to better infer about the reduction in rigidity. Overall, we present a simple, wearable, mobile system, suitable for intra-operatory conditions during DBS, supporting a physician in decision-making when setting stimulation parameters.


Subject(s)
Deep Brain Stimulation/methods , Intraoperative Neurophysiological Monitoring , Muscle Rigidity/diagnosis , Parkinson Disease/therapy , Wrist , Humans , Parkinson Disease/diagnosis
8.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 6339-6342, 2016 Aug.
Article in English | MEDLINE | ID: mdl-28269699

ABSTRACT

Hippocampal sclerosis (HS) is the most common cause of temporal lobe epilepsy (TLE) and can be identified in magnetic resonance imaging as hippocampal atrophy and subsequent volume loss. Detecting this kind of abnormalities through simple radiological assessment could be difficult, even for experienced radiologists. For that reason, hippocampal volumetry is generally used to support this kind of diagnosis. Manual volumetry is the traditional approach but it is time consuming and requires the physician to be familiar with neuroimaging software tools. In this paper, we propose an automated method, written as a script that uses FSL-FIRST, to perform hippocampal segmentation and compute an index to quantify hippocampi asymmetry (HAI). We compared the automated detection of HS (left or right) based on the HAI with the agreement of two experts in a group of 19 patients and 15 controls, achieving 84.2% sensitivity, 86.7% specificity and a Cohen's kappa coefficient of 0.704. The proposed method is integrated in the "Advanced Brain Imaging Lab" (ABrIL) cloud neurocomputing platform. The automated procedure is 77% (on average) faster to compute vs. the manual volumetry segmentation performed by an experienced physician.


Subject(s)
Epilepsy, Temporal Lobe/pathology , Hippocampus/pathology , Adult , Automation , Female , Hippocampus/diagnostic imaging , Humans , Magnetic Resonance Imaging , Male , Neuroimaging , Organ Size , Sclerosis , Sensitivity and Specificity , Time Factors
9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 2339-2342, 2016 Aug.
Article in English | MEDLINE | ID: mdl-28268795

ABSTRACT

Many neurological diseases, such as Parkinson's disease and epilepsy, can significantly impair the motor function of the patients, often leading to a dramatic loss of their quality of life. Human motion analysis is regarded as fundamental towards an early diagnosis and enhanced follow-up in this type of diseases. In this contribution, we present NeuroKinect, a novel system designed for motion analysis in neurological diseases. This system includes an RGB-D camera (Microsoft Kinect) and two integrated software applications, KiT (KinecTracker) and KiMA (Kinect Motion Analyzer). The applications enable the preview, acquisition, review and management of data provided by the sensor, which are then used for motion analysis of relevant events. NeuroKinect is a portable, low-cost and markerless solution that is suitable for use in the clinical environment. Furthermore, it is able to provide quantitative support to the clinical assessment of different neurological diseases with movement impairments, as demonstrated by its usage in two different clinical routine scenarios: gait analysis in Parkinson's disease and seizure semiology analysis in epilepsy.


Subject(s)
Image Processing, Computer-Assisted , Motion , Parkinson Disease , Software , Humans , Movement , Photography , Quality of Life
10.
Article in English | MEDLINE | ID: mdl-26737724

ABSTRACT

The communication between two neurons is established by endogenous chemical particles aggregated in vesicles that move along the axons. It is known that an abnormal transport of these vesicles is correlated with neurodegenerative diseases. The quantification of the dynamics of vesicles movement can therefore be a window to study early detection of such diseases. Nevertheless, most of the studies in the literature rely on manual tracking techniques. In this paper we present a novel methodology for quantifying neurotransmitter vesicle dynamics by using a combination of image tracking and classification algorithms. We use confocal microscopy videos of living neurons to detect and classify vesicles using support vector machine (SVM), while motion is extracted via global nearest neighbor (GNN) tracking approach. Results of the classification algorithm are presented and compared to a ground truth dataset defined by experts. Sensitivity of 90% and specificity of 97% were obtained at a much lower computational cost than an established method from the literature (0.24s/frame vs. 125s/frame). These preliminary results suggest the great potential of the method and tool we have been developing for single particle movement dynamics measure in living cells.


Subject(s)
Axons/physiology , Neurotransmitter Agents/metabolism , Transport Vesicles/physiology , Algorithms , Axonal Transport , Humans , Image Processing, Computer-Assisted , Microscopy, Confocal , Microscopy, Fluorescence , Single-Cell Analysis , Support Vector Machine , Time-Lapse Imaging , User-Computer Interface
11.
Annu Int Conf IEEE Eng Med Biol Soc ; 2015: 1279-82, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26736501

ABSTRACT

Human motion analysis can provide valuable information for supporting the clinical assessment of movement disorders, such as Parkinson's disease (PD). In this contribution, we study the suitability of a Kinect v2 based system for supporting PD assessment in a clinical environment, in comparison to the original Kinect (v1). In this study, 3-D body joint data were acquired from both normal subjects, and PD patients treated with deep brain stimulation (DBS). Then, several gait parameters were extracted from the gathered data. The obtained results show that 96% of the considered parameters are appropriate for distinguishing between non-PD subjects, PD patients with DBS stimulator switched on, and PD patients with stimulator switched off (p-value <; 0.001, Kruskal-Wallis test). These results are markedly better than the ones obtained using Kinect v1, where only 73% of the parameters are considered appropriate (p-value <; 0.001).


Subject(s)
Parkinson Disease , Deep Brain Stimulation , Gait , Humans , Subthalamic Nucleus
12.
Article in English | MEDLINE | ID: mdl-25570014

ABSTRACT

Neuroscience is an increasingly multidisciplinary and highly cooperative field where neuroimaging plays an important role. Neuroimaging rapid evolution is demanding for a growing number of computing resources and skills that need to be put in place at every lab. Typically each group tries to setup their own servers and workstations to support their neuroimaging needs, having to learn from Operating System management to specific neuroscience software tools details before any results can be obtained from each setup. This setup and learning process is replicated in every lab, even if a strong collaboration among several groups is going on. In this paper we present a new cloud service model - Brain Imaging Application as a Service (BiAaaS) - and one of its implementation - Advanced Brain Imaging Lab (ABrIL) - in the form of an ubiquitous virtual desktop remote infrastructure that offers a set of neuroimaging computational services in an interactive neuroscientist-friendly graphical user interface (GUI). This remote desktop has been used for several multi-institution cooperative projects with different neuroscience objectives that already achieved important results, such as the contribution to a high impact paper published in the January issue of the Neuroimage journal. The ABrIL system has shown its applicability in several neuroscience projects with a relatively low-cost, promoting truly collaborative actions and speeding up project results and their clinical applicability.


Subject(s)
Neuroimaging , User-Computer Interface , Brain/anatomy & histology , Brain/physiology , Brain Mapping , Cloud Computing , Diffusion Tensor Imaging , Humans
13.
Article in English | MEDLINE | ID: mdl-25570653

ABSTRACT

Movement-related diseases, such as Parkinson's disease (PD), progressively affect the motor function, many times leading to severe motor impairment and dramatic loss of the patients' quality of life. Human motion analysis techniques can be very useful to support clinical assessment of this type of diseases. In this contribution, we present a RGB-D camera (Microsoft Kinect) system and its evaluation for PD assessment. Based on skeleton data extracted from the gait of three PD patients treated with deep brain stimulation and three control subjects, several gait parameters were computed and analyzed, with the aim of discriminating between non-PD and PD subjects, as well as between two PD states (stimulator ON and OFF). We verified that among the several quantitative gait parameters, the variance of the center shoulder velocity presented the highest discriminative power to distinguish between non-PD, PD ON and PD OFF states (p = 0.004). Furthermore, we have shown that our low-cost portable system can be easily mounted in any hospital environment for evaluating patients' gait. These results demonstrate the potential of using a RGB-D camera as a PD assessment tool.


Subject(s)
Gait/physiology , Parkinson Disease/physiopathology , Photography/instrumentation , Deep Brain Stimulation , Female , Humans , Joints/physiopathology , Male , Middle Aged , User-Computer Interface
SELECTION OF CITATIONS
SEARCH DETAIL