Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Heart Lung Circ ; 31(8): 1166-1175, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35339372

ABSTRACT

OBJECTIVES: The clinical implications of finding immobile leaflet(s) at the time of bioprosthetic valve implantation but with acceptable prosthetic haemodynamics are uncertain. We sought to determine the characteristics of such patients and their impact on outcome. METHODS: Patients with immobile leaflet at the time of surgical bioprosthetic valve implantation were identified retrospectively by a systematic search of an institutional echocardiography database (2010-2020). Intraoperative echocardiograms were reviewed de-novo to confirm immobile leaflet(s) at the time of implantation. Cases were matched 1:2 to controls with normal bioprosthetic leaflets motion for age, sex, prosthesis position, prosthesis model, size, year of implantation, and pre-implantation left ventricular ejection fraction. Proportional hazards method was used to analyse the composite endpoint of stroke, valve thrombosis or re-intervention. RESULTS: Immobile leaflet at the time of bioprosthetic valve implantation were found in 26 patients (median age 71 ys 39% males) following tricuspid (n=13), mitral (n=11) and aortic (n=2) valve replacements; 96% received porcine prostheses; prosthesis size was 27 mm or larger in 92%. Immobile leaflet were recorded on intraoperative reports in 16 (62%) cases. It resulted in elevated gradient or mild-moderate prosthetic regurgitation in three (12%), but none led to immediate corrective action intraoperatively. At median follow-up of 21 (4-50) months, presence of immobile leaflet was associated with composite clinical endpoint of stroke, valve thrombosis or re-intervention (hazard ratio 6.8, 95% CI 1.8-25.2, p<0.01) compared to controls. CONCLUSION: Immobile leaflet immediately post-bioprosthetic valve implantation is frequently under-recognised intraoperatively and appears to be associated with early bioprosthetic dysfunction and worse clinical outcome.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Stroke , Thrombosis , Animals , Bioprosthesis/adverse effects , Female , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Male , Prosthesis Design , Prosthesis Failure , Retrospective Studies , Risk Factors , Stroke/etiology , Stroke Volume , Swine , Thrombosis/etiology , Treatment Outcome , Ventricular Function, Left
2.
Curr Cardiol Rep ; 22(8): 60, 2020 06 19.
Article in English | MEDLINE | ID: mdl-32562136

ABSTRACT

PURPOSE OF REVIEW: This review summarizes the optimal techniques for the performance of pericardiocentesis in contemporary practice, highlighting the indications, contraindications, and techniques used. Routine pericardial catheter management and the diagnostic role of pericardial fluid analysis are described. RECENT FINDINGS: Echocardiographic-guided pericardiocentesis should be considered the therapy of choice in current clinical practice and may be performed safely despite the presence of coagulopathy and thrombocytopenia in the hands of expert operators. Computed tomography (CT)-guided techniques may provide a useful adjunctive tool in patients with poor acoustic windows or complex loculated effusions. Conservative management utilizing pericardiocentesis may be considered in select patients with device lead and interventional-related pericardial effusions. Echocardiographic-guided pericardiocentesis with extended pericardial drainage (goal output < 50 mL/24 h) should be considered the standard of care in contemporary practice. Pericardial fluid analysis should be tailored based on the clinical history and appearances of the pericardial fluid.


Subject(s)
Cardiac Tamponade , Pericardial Effusion , Echocardiography , Humans , Pericardiocentesis , Pericardium
3.
Am Heart J ; 215: 12-19, 2019 09.
Article in English | MEDLINE | ID: mdl-31260901

ABSTRACT

Prior studies have demonstrated that the cardiac intensive care unit (CICU) patient population has evolved over time. We sought to describe the temporal changes in comorbidities, illness severity, diagnoses, procedures and adjusted mortality within our CICU practice in recent years. METHODS: We retrospectively reviewed unique CICU admissions at the Mayo Clinic from January 2007 to April 2018. Comorbidities, severity of illness scores, discharge diagnosis codes and CICU procedures and therapies were recorded, and temporal trends were assessed using linear regression and Cochran-Armitage trend tests. Trends in adjusted hospital mortality over time were assessed using multivariable logistic regression. RESULTS: We included 12,418 patients with a mean age of 67.6 years (including 37.7% females). Temporal trends in the prevalence of several comorbidities and discharge diagnoses were observed, reflecting an increase in the prevalence of non-coronary cardiovascular diseases, critical care diagnoses, and organ failure (all P ≪ .05). The use of several CICU therapies and procedures increased over time, including mechanical ventilation, invasive lines and vasoactive drugs (all P ≪ .05). A temporal decrease in adjusted hospital mortality was observed among the subgroup of patients with (adjusted OR per year 0.97, 95% CI 0.94-0.99, P = .023) and without (adjusted OR per year 0.91, 95% CI 0.85-0.96, P = .002) a critical care discharge diagnosis. CONCLUSIONS: We observed an increasing prevalence of critical care and organ failure diagnoses as well as increased utilization of critical care therapies in this CICU cohort, associated with a decrease in risk-adjusted hospital mortality over time.


Subject(s)
Cardiovascular Diseases , Coronary Care Units , Critical Care , Critical Illness , Aged , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/therapy , Comorbidity , Coronary Care Units/statistics & numerical data , Coronary Care Units/trends , Critical Care/methods , Critical Care/statistics & numerical data , Critical Care Outcomes , Critical Illness/mortality , Critical Illness/therapy , Diagnostic Techniques, Cardiovascular/classification , Female , Humans , Male , Mortality/trends , Patient Acceptance of Health Care/statistics & numerical data , Prevalence , Retrospective Studies , Severity of Illness Index , United States/epidemiology
4.
Echocardiography ; 36(7): 1397-1400, 2019 07.
Article in English | MEDLINE | ID: mdl-31209920

ABSTRACT

We describe a case of a mass-like echocardiographic density on a mechanical prosthetic aortic valve. We initially suspected a thrombus vs vegetation on transthoracic echocardiography, but after transesophageal echocardiography, the density was subsequently determined to be cavitation by reviewing the initial images in slow motion.


Subject(s)
Aortic Valve/diagnostic imaging , Echocardiography/methods , Heart Valve Prosthesis , Microbubbles , Coronary Thrombosis/diagnostic imaging , Diagnosis, Differential , Humans , Male , Middle Aged , Stress, Mechanical
5.
J Cardiovasc Electrophysiol ; 25(10): 1119-24, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24863054

ABSTRACT

INTRODUCTION: Cardiac perforation is an infrequent but potentially life-threatening complication associated with placement of a cardiac implantable electronic device (CIED). The objective of this study was to determine the outcomes of percutaneous lead revision in patients who had lead perforation of the myocardium after CIED placement. METHODS AND RESULTS: We reviewed records of 1,458 patients who underwent CIED lead extraction or repositioning. Of these, 31 (2.1%) had the procedure performed for lead perforation as a complication of CIED placement. Demographic, clinical, and follow-up characteristics of the patients were analyzed. Mean (SD) patient age was 65 (23) years. Cardiac perforation was detected within 24 hours after implantation in 9 patients, within 1 month in 17, and greater than 1 month in 5. Pericardiocentesis was performed with a pigtail drainage catheter in place before the lead revision in 17 patients (55%) who had pericardial effusion, with or without hemodynamic compromise. All culprit leads were successfully managed with percutaneous lead removal (n = 3 [10%]), new lead placement (n = 12 [38%]), or lead repositioning (n = 16 [52%]). Of the 17 patients with pericardiocentesis before the reoperation, none had tamponade develop; in contrast, 3 of the remaining 14 patients had tamponade develop and required urgent pericardiocentesis. All patients survived without requiring open chest surgery. CONCLUSION: Percutaneous removal or repositioning of the perforating lead is feasible and appears effective. Placement of a prophylactic pericardial drain catheter may reduce the incidence of urgent pericardiocentesis during or after a procedure.


Subject(s)
Cardiac Resynchronization Therapy Devices/statistics & numerical data , Device Removal/statistics & numerical data , Electrodes, Implanted/statistics & numerical data , Heart Injuries/epidemiology , Heart Injuries/prevention & control , Wounds, Penetrating/epidemiology , Wounds, Penetrating/prevention & control , Adolescent , Adult , Aged , Aged, 80 and over , Cardiac Resynchronization Therapy , Child , Heart Injuries/diagnosis , Humans , Incidence , Middle Aged , Minnesota/epidemiology , Prosthesis Failure , Prosthesis Implantation/statistics & numerical data , Reoperation/statistics & numerical data , Risk Assessment , Wounds, Penetrating/diagnosis , Young Adult
8.
JACC Case Rep ; 29(3): 102182, 2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38361568

ABSTRACT

A 68-year-old woman presented with an incidentally found intracardiac mass. Transesophageal echocardiography (TEE) showed a 26 × 8 mm mobile mass attached to a calcified posterolateral mitral annulus. The mass was removed with a commercially available percutaneous catheter system using cerebral embolic protection and TEE guidance. The pathologic examination showed caseous mitral annular calcification.

9.
Mayo Clin Proc Innov Qual Outcomes ; 8(4): 396-405, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39100655

ABSTRACT

Objective: To review the salient features of multimodality cardiovascular imaging in patients with disseminated Mycobacterium chimaera (MC) infections after exposure to contaminated heater-cooler units during cardiopulmonary bypass. Patients and Methods: Twelve patients with confirmed MC infection were retrospectively identified after a review from January 1, 2010, to April 30, 2021. The electronic medical records were examined with a focus on transthoracic echocardiography, transesophageal echocardiography, cardiac computed tomography (CT), cardiac magnetic resonance imaging, and positron emission tomography-CT. Results: Three (27.3%) patients had diagnostic findings of endocarditis on transthoracic echocardiography, with most patients having nonspecific abnormalities including elevated prosthetic valve gradients or prosthetic leaflet thickening. Transesophageal echocardiography identified 4 (36.7%) patients with vegetations and 3 (27.3%) with aortic root abscess or pseudoaneurysm, with more common findings such as mild aortic root or prosthetic leaflet thickening. Six (50%) patients underwent cardiac CT imaging, which found aortic root pseudoaneurysms or abscesses, prosthetic ring dehiscence, and leaflet thickening. Three (25%) patients underwent cardiac magnetic resonance imaging demonstrating prosthetic valve vegetations, leaflet thickening, and abnormal myocardial delayed enhancement in a noncoronary distribution, suggesting myocarditis. Ten (83%) patients underwent positron emission tomography-CT, 4 (40%) had an abnormal fluorodeoxyglucose uptake around the cardiac prosthetic material, and 7 (70%) had a fluorodeoxyglucose uptake in other organs, suggesting concomitant multiorgan involvement. Conclusion: Multimodality cardiovascular imaging is central to the management of patients with disseminated MC and can help establish a preliminary diagnosis while awaiting confirmatory microbiological data, potentially reducing the time to diagnosis. Imaging findings are subtle and atypical, not always meeting classically modified Duke's criteria for infectious endocarditis. Clinicians should have a high index of suspicion for the disease and a low threshold for repeat imaging when initial testing is equivocal.

10.
Ann Card Anaesth ; 26(1): 83-85, 2023.
Article in English | MEDLINE | ID: mdl-36722593

ABSTRACT

Although rare, iatrogenic aortocoronary arteriovenous fistulae (ACAVF) occur when a coronary graft is mistakenly anastomosed to an epicardial vein rather than its intended arterial target. Patients may be asymptomatic, demonstrate angina, dyspnea, arrhythmias, syncope, or diminished exercise capacity, and may have wide pulse pressures with evidence of coronary steal. A thorough insight into the disordered anatomy is critical to safely manage a patient for redo cardiac surgery, especially when attempting to arrest the heart. We present a case for redo cardiac surgery of an iatrogenic ACAVF confirmed perioperatively with multiple modalities and its intraoperative management.


Subject(s)
Arteriovenous Fistula , Cardiac Surgical Procedures , Humans , Coronary Artery Bypass , Heart , Angina Pectoris , Arteriovenous Fistula/diagnostic imaging , Arteriovenous Fistula/etiology , Arteriovenous Fistula/surgery
12.
J Card Surg ; 26(2): 151-3, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21158915

ABSTRACT

Diagnosing a paradoxical embolism is challenging, and it can be proven only if the thrombus is identified across the intracardiac defect. Very few cases have been diagnosed as an impending paradoxical embolism. Recently, the diagnosis and management of these entities have greatly improved with the advent of transesophageal echocardiography (compared with transthoracic echocardiography). Pulmonary hypertension may cause right-to-left shunting across a patent foramen ovale and predispose development of a paradoxical embolism. We report a patient with an impending paradoxical embolism that was caught in transit across the patent foramen ovale. The patient was treated successfully with emergent surgery.


Subject(s)
Embolism, Paradoxical/surgery , Foramen Ovale, Patent/complications , Pulmonary Embolism/surgery , Aged , Diagnosis, Differential , Echocardiography, Transesophageal , Embolism, Paradoxical/diagnosis , Embolism, Paradoxical/etiology , Follow-Up Studies , Foramen Ovale, Patent/diagnosis , Foramen Ovale, Patent/surgery , Humans , Male , Pulmonary Embolism/diagnosis , Pulmonary Embolism/etiology , Tomography, X-Ray Computed
13.
J Cardiovasc Electrophysiol ; 21(9): 1046-9, 2010 Sep.
Article in English | MEDLINE | ID: mdl-20233269

ABSTRACT

We present a case of large pneumopericardium resulting from an esophageal pericardial fistula following ablation for atrial fibrillation (AF). The presentation, evaluation, and management of this specific patient, along with a review of present techniques to diagnose esophageal injury, provide a unique insight into the pathophysiology of left atrial-esophageal fistula formation.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Esophageal Fistula/etiology , Pneumopericardium/etiology , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Debridement , Electrocardiography, Ambulatory , Electrophysiologic Techniques, Cardiac , Esophageal Fistula/diagnostic imaging , Esophageal Fistula/surgery , Heart Rate , Humans , Male , Pneumopericardium/diagnostic imaging , Pneumopericardium/surgery , Thoracotomy , Tomography, X-Ray Computed , Treatment Outcome
14.
Open Forum Infect Dis ; 7(3): ofaa069, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32211446

ABSTRACT

BACKGROUND: The American Heart Association (AHA) guidelines for infective endocarditis (IE) management recommend end-of-therapy (EOT) echocardiography (ETE) to "establish a new baseline" and based on "expert opinion." METHODS: Medical records of IE patients treated between January 2005 and December 2011 were reviewed. Utilization of ETE and cumulative incidence of re-treatment with antimicrobials or cardiovascular surgery (re-Rx/CVS) within 1 year after EOT were evaluated. RESULTS: A total of 243 patients completed clinical follow-up at EOT and 170 at 1 year after EOT. One hundred seventy-seven of 243 (72.8%) underwent ETE, the majority (51.4%) transthoracic echocardiography. One hundred thirty-three of 177 (75.1%) were without new/worsened signs or symptoms (new/w-SSx). One hundred forty-one of 177 (79.7%) overall and 117/133 (87.9%) patients without new/w-SSx had no new ETE findings as compared with initial echocardiography. Among 36/177 (20.3%) with new ETE findings, 20/36 (55.6%) had new/w-SSx; ETE findings were more likely in patients with new/w-SSx (39.2% vs 8.3%; P < 0.001) at EOT. Patients were at increased risk of re-Rx/CVS with either new ETE findings (hazard ratio [HR], 25.86; 95% confidence interval [CI], 7.64-87.56; P < .001) or new/w-SSx (HR, 5.35; 95% CI, 2.87-9.95; P < .001). The highest risk of re-Rx/CVS was in patients with both new/w-SSx and new ETE findings (HR, 45.94; 95% CI, 19.07-110.71). Conversely, only 7/187 (3.4%) patients without new/w-SSx who had an ETE required re-Rx/CVS. CONCLUSIONS: The majority of patients without new/w-SSx at EOT will not have new ETE findings or need re-Rx/CVS within 1 year after EOT. EOT new/w-SSx is associated with new ETE findings and predicts the need for re-Rx/CVS. Further study is needed to determine whether patients without new/w-SSx need ETE.

15.
J Cardiovasc Electrophysiol ; 20(3): 280-3, 2009 Mar.
Article in English | MEDLINE | ID: mdl-19261039

ABSTRACT

INTRODUCTION: Emergency pericardiocentesis during electrophysiology procedures is often associated with significant aspiration of pericardial blood, requiring transfusion. We sought to assess the feasibility of urgent use of an autologous blood recovery system in the electrophysiology laboratory to autotransfuse blood aspirated from the pericardium. METHODS AND RESULTS: We retrospectively analyzed Mayo Clinic electrophysiology records for patients who had ablation procedure-related pericardial effusions requiring emergency pericardial drainage during an 8-month period. An autologous blood recovery system was used during pericardiocentesis to separate and clean packed red blood cells from the pericardial aspirate. These cells were returned acutely to the patient intravenously. The procedural safety, aspirated and autotransfused volumes, and efficacy of this approach were evaluated. During the study period, nine patients underwent pericardial drainage with autotransfusion using a cell-salvage instrument during electrophysiology procedures. The mean aspirated volume was 1,078 mL, with a mean autotransfused volume of 390 mL. For four patients, all with aspirated volumes of 1,100 mL or less, autotransfusion alone was sufficient to maintain hemodynamic stability and avoid allogeneic transfusion. One patient required surgical intervention because of ongoing pericardial bleeding. The ablation procedure was completed after aspiration in two patients. No procedural complications related to the use of the cell-salvage system occurred. CONCLUSION: Autologous blood recovery during pericardiocentesis is safe, convenient, and feasible. With early use it may decrease or eliminate the need for allogeneic blood transfusion and, in selected cases, may permit completion of the ablation procedure.


Subject(s)
Blood Component Removal/instrumentation , Blood Transfusion, Autologous/instrumentation , Cardiac Tamponade/etiology , Cardiac Tamponade/prevention & control , Catheter Ablation/adverse effects , Pericardial Effusion/etiology , Pericardial Effusion/therapy , Pericardiocentesis/instrumentation , Adult , Aged , Blood Transfusion, Autologous/methods , Emergency Medical Services/methods , Equipment Design , Equipment Failure Analysis , Female , Humans , Male , Middle Aged , Pericardiocentesis/methods , Retrospective Studies , Treatment Outcome
16.
Eur Heart J Cardiovasc Imaging ; 20(3): 298-306, 2019 03 01.
Article in English | MEDLINE | ID: mdl-29982372

ABSTRACT

AIMS: To review 2D and Doppler findings in patients diagnosed with effusive-constrictive pericarditis (ECP) and compare these to patients with cardiac tamponade and patients with surgically-proven constrictive pericarditis (CP). METHODS AND RESULTS: We identified 22 patients diagnosed with ECP at Mayo Clinic, MN, USA between 2002 and 2016 who had persistent elevation of jugular venous pressure post-pericardiocentesis. We compared them to 30 patients with CP and 30 patients with cardiac tamponade who had normalization of venous pressure post-pericardiocentesis. All patients were in sinus rhythm. Mean age was 57 ± 18 years in the ECP group; 36% were females. Most ECP and cardiac tamponade cases were idiopathic (41% and 33%, respectively). Prior to pericardiocentesis, medial and lateral e' velocities were higher in ECP compared with tamponade; both ECP and tamponade patients had markedly decreased hepatic vein diastolic forward flow velocities. Inspiratory and expiratory mitral E/A ratios were higher in ECP compared with tamponade, but lower than those observed in CP. Post-pericardiocentesis, hepatic vein diastolic forward flow velocities increased in both ECP and tamponade. Hepatic vein diastolic reversal velocities decreased in tamponade but were unchanged in ECP. During median follow-up of 481 days, three patients required pericardiectomy for CP; they were all in the ECP group (14% of ECP cases). CONCLUSION: ECP may have unique echo-Doppler features that distinguish it from both CP and tamponade. Our findings suggest that ECP could be diagnosed by echocardiography even prior to pericardiocentesis. ECP appears to have a good prognosis, particularly in patients presenting acutely.


Subject(s)
Cardiac Tamponade/diagnostic imaging , Cardiac Tamponade/surgery , Echocardiography, Doppler/methods , Pericarditis, Constrictive/diagnostic imaging , Pericarditis, Constrictive/surgery , Academic Medical Centers , Aged , Cardiac Tamponade/physiopathology , Cohort Studies , Female , Humans , Male , Middle Aged , Pericardiectomy/methods , Pericardiocentesis/methods , Pericarditis, Constrictive/physiopathology , Postoperative Care/methods , Preoperative Care , Prognosis , Retrospective Studies , Risk Assessment , Statistics, Nonparametric , Treatment Outcome
17.
J Vasc Surg ; 48(6): 1600-2, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19118743

ABSTRACT

Chylopericardium is an uncommon disease predominantly caused by trauma. Prolonged chyle depletion may result in nutritional, metabolic, and immunologic deficiencies due to loss of essential proteins, immunoglobulins, fat, vitamins, electrolytes, and water. Medical treatment includes a low-fat diet with medium-chain triglyceride restriction, cardiac support, diuretic medications, and drainage of the pericardial effusion. Conventional surgical therapy consists of pericardial fenestration and thoracic duct ligation. We report a case of massive secondary chylous pericardial effusion successfully treated with microsurgical lymphovenous anastomosis, reconnecting the occluded thoracic duct to the internal jugular vein. This case highlights features and management strategies of this perplexing clinical condition.


Subject(s)
Pericardial Effusion/surgery , Plastic Surgery Procedures/methods , Thoracic Duct/surgery , Vascular Surgical Procedures/methods , Aged , Constriction, Pathologic , Diagnosis, Differential , Echocardiography , Female , Follow-Up Studies , Humans , Lymphography , Pericardial Effusion/diagnosis , Pericardial Effusion/etiology , Thoracic Duct/diagnostic imaging , Tomography, X-Ray Computed
19.
Circulation ; 111(5): 546-54, 2005 Feb 08.
Article in English | MEDLINE | ID: mdl-15699274

ABSTRACT

BACKGROUND: Although segmental or circumferential ablation is effective in eliminating pulmonary vein (PV)-mediated atrial fibrillation (AF), this procedure may be complicated by the occurrence of PV stenosis. METHODS AND RESULTS: To establish the clinical presentation, diagnostic manifestations, and interventional management of PV stenosis, 23 patients with stenosis of 34 veins complicating ablation of AF were evaluated. Each patient became symptomatic 103+/-100 days after undergoing ablation. In 8 veins, the ablation producing the PV stenosis was a repeated procedure for continued AF. Nineteen patients presented with dyspnea on exertion, 7 with dyspnea at rest, 9 with cough, and 6 with chest pain. On multirow spiral computed tomography examination, the narrowest lumen of the affected PVs measured 3+/-2 mm compared with 13+/-3 mm at baseline (P< or =0.001). The relative perfusion of affected lung segments on isotope scans was reduced to 4+/-3% of total perfusion compared with 22+/-10% in unaffected segments. At percutaneous intervention, these veins showed 80+/-13% stenosis, with a mean gradient of 12+/-5 mm Hg. This was significantly reduced to a residual stenosis of 9+/-8% (P< or =0.001) and a residual gradient of 3+/-4 mm Hg (P< or =0.001). Twenty veins were treated with balloon dilatation alone, whereas 14 veins were stented with standard 10-mm-diameter bare-metal stents. Although the symptomatic response was nearly immediate and impressive, 14 patients developed in-stent or in-segment restenosis, requiring repeated interventions in 13. CONCLUSIONS: Percutaneous intervention produces rapid and dramatic symptom relief in patients with highly symptomatic PV stenosis after radiofrequency ablation for AF. Nevertheless, alternative treatment methods will be required to decrease recurrent in-stent or in-segment restenosis.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Pulmonary Veins/surgery , Pulmonary Veno-Occlusive Disease/diagnosis , Pulmonary Veno-Occlusive Disease/therapy , Adult , Atrial Fibrillation/complications , Constriction, Pathologic/diagnosis , Constriction, Pathologic/etiology , Constriction, Pathologic/therapy , Echocardiography, Transesophageal , Female , Follow-Up Studies , Humans , Male , Middle Aged , Pulmonary Veins/diagnostic imaging , Pulmonary Veno-Occlusive Disease/etiology , Tomography, X-Ray Computed
20.
Acute Card Care ; 18(1): 25-27, 2016 Mar.
Article in English | MEDLINE | ID: mdl-27754701
SELECTION OF CITATIONS
SEARCH DETAIL