Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 314
Filter
Add more filters

Publication year range
1.
N Engl J Med ; 389(21): 1949-1960, 2023 Nov 23.
Article in English | MEDLINE | ID: mdl-37874020

ABSTRACT

BACKGROUND: A previous analysis in this trial showed that among patients with severe, symptomatic aortic stenosis who were at low surgical risk, the rate of the composite end point of death, stroke, or rehospitalization at 1 year was significantly lower with transcatheter aortic-valve replacement (TAVR) than with surgical aortic-valve replacement. Longer-term outcomes are unknown. METHODS: We randomly assigned patients with severe, symptomatic aortic stenosis and low surgical risk to undergo either TAVR or surgery. The first primary end point was a composite of death, stroke, or rehospitalization related to the valve, the procedure, or heart failure. The second primary end point was a hierarchical composite that included death, disabling stroke, nondisabling stroke, and the number of rehospitalization days, analyzed with the use of a win ratio analysis. Clinical, echocardiographic, and health-status outcomes were assessed through 5 years. RESULTS: A total of 1000 patients underwent randomization: 503 patients were assigned to undergo TAVR, and 497 to undergo surgery. A component of the first primary end point occurred in 111 of 496 patients in the TAVR group and in 117 of 454 patients in the surgery group (Kaplan-Meier estimates, 22.8% in the TAVR group and 27.2% in the surgery group; difference, -4.3 percentage points; 95% confidence interval [CI], -9.9 to 1.3; P = 0.07). The win ratio for the second primary end point was 1.17 (95% CI, 0.90 to 1.51; P = 0.25). The Kaplan-Meier estimates for the components of the first primary end point were as follows: death, 10.0% in the TAVR group and 8.2% in the surgery group; stroke, 5.8% and 6.4%, respectively; and rehospitalization, 13.7% and 17.4%. The hemodynamic performance of the valve, assessed according to the mean (±SD) valve gradient, was 12.8±6.5 mm Hg in the TAVR group and 11.7±5.6 mm Hg in the surgery group. Bioprosthetic-valve failure occurred in 3.3% of the patients in the TAVR group and in 3.8% of those in the surgery group. CONCLUSIONS: Among low-risk patients with severe, symptomatic aortic stenosis who underwent TAVR or surgery, there was no significant between-group difference in the two primary composite outcomes. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Postoperative Complications/etiology , Risk Factors , Stroke/epidemiology , Stroke/etiology , Stroke/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , Follow-Up Studies , Patient Readmission , Heart Failure/etiology
2.
Circulation ; 149(9): 658-668, 2024 02 27.
Article in English | MEDLINE | ID: mdl-38084590

ABSTRACT

BACKGROUND: Deep hypothermia has been the standard for hypothermic circulatory arrest (HCA) during aortic arch surgery. However, centers worldwide have shifted toward lesser hypothermia with antegrade cerebral perfusion. This has been supported by retrospective data, but there has yet to be a multicenter, prospective randomized study comparing deep versus moderate hypothermia during HCA. METHODS: This was a randomized single-blind trial (GOT ICE [Cognitive Effects of Body Temperature During Hypothermic Circulatory Arrest]) of patients undergoing arch surgery with HCA plus antegrade cerebral perfusion at 4 US referral aortic centers (August 2016-December 2021). Patients were randomized to 1 of 3 hypothermia groups: DP, deep (≤20.0 °C); LM, low-moderate (20.1-24.0 °C); and HM, high-moderate (24.1-28.0 °C). The primary outcome was composite global cognitive change score between baseline and 4 weeks postoperatively. Analysis followed the intention-to-treat principle to evaluate if: (1) LM noninferior to DP on global cognitive change score; (2) DP superior to HM. The secondary outcomes were domain-specific cognitive change scores, neuroimaging findings, quality of life, and adverse events. RESULTS: A total of 308 patients consented; 282 met inclusion and were randomized. A total of 273 completed surgery, and 251 completed the 4-week follow-up (DP, 85 [34%]; LM, 80 [34%]; HM, 86 [34%]). Mean global cognitive change score from baseline to 4 weeks in the LM group was noninferior to the DP group; likewise, no significant difference was observed between DP and HM. Noninferiority of LM versus DP, and lack of difference between DP and HM, remained for domain-specific cognitive change scores, except structured verbal memory, with noninferiority of LM versus DP not established and structured verbal memory better preserved in DP versus HM (P = 0.036). There were no significant differences in structural or functional magnetic resonance imaging brain imaging between groups postoperatively. Regardless of temperature, patients who underwent HCA demonstrated significant reductions in cerebral gray matter volume, cortical thickness, and regional brain functional connectivity. Thirty-day in-hospital mortality, major morbidity, and quality of life were not different between groups. CONCLUSIONS: This randomized multicenter study evaluating arch surgery HCA temperature strategies found low-moderate hypothermia noninferior to traditional deep hypothermia on global cognitive change 4 weeks after surgery, although in secondary analysis, structured verbal memory was better preserved in the deep group. The verbal memory differences in the low- and high-moderate groups and structural and functional connectivity reductions from baseline merit further investigation and suggest opportunities to further optimize brain perfusion during HCA. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02834065.


Subject(s)
Aorta, Thoracic , Hypothermia , Humans , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Retrospective Studies , Prospective Studies , Quality of Life , Single-Blind Method , Body Temperature , Circulatory Arrest, Deep Hypothermia Induced/adverse effects , Perfusion/adverse effects , Perfusion/methods , Cognition , Cerebrovascular Circulation , Treatment Outcome
3.
Genomics ; 116(5): 110878, 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38851465

ABSTRACT

Traumatic perioperative conditions may trigger early systemic responses, activate leukocytes and reprogram the immune system. We hypothesize that leukocyte activation may not revert to pre-surgical states, and that protracted activation may emerge with increased risks of comorbidities. We tested this concept by examining the transcriptomes of monocytes and T cells in a representative observational cohort of patients (n = 13) admitted for elective cardiac surgery. Transcriptomes in T cells and monocytes were compared from before surgery (t0), and monocytes were analyzed longitudinally after acute (t24hr), and convalescent (t3m) time points. Monocytes and T cells expressed distinct transcriptomes, reflected by statistically significant differential expression of 558 T cell related genes. Monocytes expressed genes related to protein degradation and presented atypical activation of surface markers and cytoplasmic functions over time. Additionally, monocytes exhibited limited transcriptomic heterogeneity prior to surgery, and long-term patterns of gene expression associated with atherosclerosis showed three temporally distinct signatures. These data establish that post-cardiac surgery transcriptomes of monocytes differ even at three months compared to baselines, which may reflect latent ('smoldering') inflammation and persistent progression of tissue degenerative processes that should inform clinical care.

4.
N Engl J Med ; 382(9): 799-809, 2020 02 27.
Article in English | MEDLINE | ID: mdl-31995682

ABSTRACT

BACKGROUND: There are scant data on long-term clinical outcomes and bioprosthetic-valve function after transcatheter aortic-valve replacement (TAVR) as compared with surgical aortic-valve replacement in patients with severe aortic stenosis and intermediate surgical risk. METHODS: We enrolled 2032 intermediate-risk patients with severe, symptomatic aortic stenosis at 57 centers. Patients were stratified according to intended transfemoral or transthoracic access (76.3% and 23.7%, respectively) and were randomly assigned to undergo either TAVR or surgical replacement. Clinical, echocardiographic, and health-status outcomes were followed for 5 years. The primary end point was death from any cause or disabling stroke. RESULTS: At 5 years, there was no significant difference in the incidence of death from any cause or disabling stroke between the TAVR group and the surgery group (47.9% and 43.4%, respectively; hazard ratio, 1.09; 95% confidence interval [CI], 0.95 to 1.25; P = 0.21). Results were similar for the transfemoral-access cohort (44.5% and 42.0%, respectively; hazard ratio, 1.02; 95% CI, 0.87 to 1.20), but the incidence of death or disabling stroke was higher after TAVR than after surgery in the transthoracic-access cohort (59.3% vs. 48.3%; hazard ratio, 1.32; 95% CI, 1.02 to 1.71). At 5 years, more patients in the TAVR group than in the surgery group had at least mild paravalvular aortic regurgitation (33.3% vs. 6.3%). Repeat hospitalizations were more frequent after TAVR than after surgery (33.3% vs. 25.2%), as were aortic-valve reinterventions (3.2% vs. 0.8%). Improvement in health status at 5 years was similar for TAVR and surgery. CONCLUSIONS: Among patients with aortic stenosis who were at intermediate surgical risk, there was no significant difference in the incidence of death or disabling stroke at 5 years after TAVR as compared with surgical aortic-valve replacement. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.).


Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Cohort Studies , Echocardiography , Female , Health Status , Humans , Incidence , Intention to Treat Analysis , Kaplan-Meier Estimate , Male , Multivariate Analysis , Postoperative Complications/mortality , Risk Factors , Stroke/epidemiology , Stroke/etiology , Treatment Outcome
5.
J Endovasc Ther ; : 15266028231187741, 2023 Jul 24.
Article in English | MEDLINE | ID: mdl-37485662

ABSTRACT

PURPOSE: This study presents analytic techniques to quantify cardiac pulsatility-induced deformations of thoracic aortic endografts in patients with thoracic aortic aneurysm (TAA), dissection (TAD), and blunt thoracic aortic injury (BTAI) after thoracic endovascular aortic repair (TEVAR). TECHNIQUE: We analyzed 19 image data sets from 14 patients treated for TAA, TAD, and BTAI with cardiac-gated post-TEVAR CTs. Systolic and diastolic geometric models were constructed and diametric, axial, and bending deformations were quantified. For patients with cardiac-gated pre-op scans, the damping of pulsatile diametric distension was computed. Maximum localized diametric distension was 2.4±1.0%, 4.2±1.7%, and 5.5±1.6%, and axial deformation was 0.0±0.1%, -0.1±0.3%, and 1.1±0.6% in the endografts of TAA, TAD, and BTAI cohorts, respectively. Diametric distension damping from pre- to post-TEVAR was ~50%. Diametric and bending deformations were localized at certain axial positions on the endograft, and the inner curve bends more than the centerline, especially adjacent to overlapping regions. CONCLUSION: The presented techniques support investigation of multi-axial endograft deformations between disease causes and geometric locations on the device. Discretized quantification of deformation is needed to define device fatigue testing conditions and predict device durability in patients. CLINICAL IMPACT: This study demonstrates analytic techniques to quantify discretized deformation of thoracic endografts. Cardiac-resolved computed tomography is sometimes acquired for surgical planning and follow-up, however, the dynamic data are not typically used to quantify pulsatile deformations. Our analytic techniques extract the centerline and surface geometry of the stented thoracic aorta during the cardiac cycle, which are used to quantify diametric, axial, and bending deformations to provide better understanding of device durability and impact on the native anatomy.

6.
Med Sci Monit ; 29: e937934, 2023 Jan 13.
Article in English | MEDLINE | ID: mdl-36635948

ABSTRACT

BACKGROUND Receptor activator of nuclear factor kappa B ligand (RANKL), osteoprotegerin (OPG), cartilage oligomeric matrix protein (COMP), bone morphogenetic protein (BMP-2), and fibroblast growth factor 23 (FGF-23) are involved in inflammation, calcium deposition, and fibrosis of blood vessels. Acute changes in these factors may contribute to the progression of arteriosclerosis, especially if their elevated serum levels persist postoperatively. MATERIAL AND METHODS A total of 90 patients (79 White, 4 African American, and 7 Other) undergoing elective heart surgery were enrolled in the study. Blood was collected before surgery and after surgery at 24 hours, 7 days, and 3 months to allow for longitudinal comparisons. After the plasma isolation, several biomarkers levels were studied using an enzymatic-linked assay. Demographic and clinical information were obtained from electronic health records. RESULTS At 24 hours after surgery, RANKL (RANKLbaseline=248.7±215.7 vs RANKLt24h=376.4±329.7; P=0.035), and BMP-2 (BMP-2baseline=283.7±255.4 vs BMP-2t24h=482.4; P=0.015) were significantly elevated compared to baseline, with levels returning to baseline at 7 days. FGF-23 increased significantly from baseline (FGF-23baseline=1020±1210) to 7 days (FGF-237d=2191±5188; P=0.029) and remained significantly higher than baseline at 3 months (FGF-233m=2041±3521; P=0.044). White blood cells (WBC) remained elevated at discharge (WBCbaseline=6.8±2.1 vs WBC24h=15.0±5.3 vs WBCdischarge=8.8±3.4). IL-8 and C-reactive protein normalized at 3 months. Estimated blood loss was significantly correlated with RANKL at 24 hours (r²=0.33; P=0.035). Serum creatinine levels after surgery at 24 hours (r²=0.41; p=0.008) and 7 days (r²=0.59; P=0.000) was strongly correlated with COMP. CONCLUSIONS Persistent elevation of serum FGF-23 indicates a potential for accelerated arteriosclerosis after cardiac surgery.


Subject(s)
Arteriosclerosis , Cardiac Surgical Procedures , Humans , Receptor Activator of Nuclear Factor-kappa B , RANK Ligand/metabolism , Cartilage Oligomeric Matrix Protein , Fibroblast Growth Factor-23 , Convalescence , Osteoprotegerin
7.
N Engl J Med ; 380(18): 1695-1705, 2019 05 02.
Article in English | MEDLINE | ID: mdl-30883058

ABSTRACT

BACKGROUND: Among patients with aortic stenosis who are at intermediate or high risk for death with surgery, major outcomes are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. There is insufficient evidence regarding the comparison of the two procedures in patients who are at low risk. METHODS: We randomly assigned patients with severe aortic stenosis and low surgical risk to undergo either TAVR with transfemoral placement of a balloon-expandable valve or surgery. The primary end point was a composite of death, stroke, or rehospitalization at 1 year. Both noninferiority testing (with a prespecified margin of 6 percentage points) and superiority testing were performed in the as-treated population. RESULTS: At 71 centers, 1000 patients underwent randomization. The mean age of the patients was 73 years, and the mean Society of Thoracic Surgeons risk score was 1.9% (with scores ranging from 0 to 100% and higher scores indicating a greater risk of death within 30 days after the procedure). The Kaplan-Meier estimate of the rate of the primary composite end point at 1 year was significantly lower in the TAVR group than in the surgery group (8.5% vs. 15.1%; absolute difference, -6.6 percentage points; 95% confidence interval [CI], -10.8 to -2.5; P<0.001 for noninferiority; hazard ratio, 0.54; 95% CI, 0.37 to 0.79; P = 0.001 for superiority). At 30 days, TAVR resulted in a lower rate of stroke than surgery (P = 0.02) and in lower rates of death or stroke (P = 0.01) and new-onset atrial fibrillation (P<0.001). TAVR also resulted in a shorter index hospitalization than surgery (P<0.001) and in a lower risk of a poor treatment outcome (death or a low Kansas City Cardiomyopathy Questionnaire score) at 30 days (P<0.001). There were no significant between-group differences in major vascular complications, new permanent pacemaker insertions, or moderate or severe paravalvular regurgitation. CONCLUSIONS: Among patients with severe aortic stenosis who were at low surgical risk, the rate of the composite of death, stroke, or rehospitalization at 1 year was significantly lower with TAVR than with surgery. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Patient Readmission/statistics & numerical data , Postoperative Complications/epidemiology , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/mortality , Atrial Fibrillation/etiology , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Kaplan-Meier Estimate , Length of Stay , Male , Prosthesis Design , Risk Factors , Stroke/epidemiology , Stroke/etiology , Transcatheter Aortic Valve Replacement/adverse effects
8.
J Vasc Surg ; 76(1): 88-95.e1, 2022 07.
Article in English | MEDLINE | ID: mdl-35276270

ABSTRACT

OBJECTIVE: General anesthesia (GA) is associated with inherent risks that can be avoided by the use of lesser invasive anesthetic strategies. We hypothesize that examine and compare the use of local or regional anesthesia (LRA) to that of GA in patients undergoing thoracic endovascular aortic repair (TEVAR). METHODS: Patients undergoing TEVAR between 2010 and 2020 in the Vascular Quality Initiative were analyzed. Exclusion criteria included receipt of branched or physician-modified endografts and devices extending distally beyond zone 5. Patients were categorized as receiving LRA or GA. Center volume was reported by quartile according to annualized TEVAR volume, and operative outcomes were compared using appropriate frequentists tests. Univariable and multivariable regression models for anesthesia type and operative outcomes were created to compare unadjusted and adjusted rates of each outcome. Long-term survival was estimated using a Kaplan-Meier survival estimator, whereas adjusted survival analysis was performed using a Cox proportional hazards model. RESULTS: Of the 17,099 patients who underwent TEVAR, 7299 met the inclusion and exclusion criteria. Of these, 3.8% received LRA. There were no significant differences in the annual proportion of patients who received LRA from 2011 to 2020 (P = .49, χ2 test for trend). Only 18.8% of patients who received LRA were treated at the highest quartile volume centers. Patients who received LRA were older and more comorbid compared with those who received GA. There were no differences in in-hospital mortality (odds ratio [OR], 0.79; 95% confidence interval [CI], 0.42-1.38; P = .44) or composite of any complication (OR, 0.79; 95% CI, 0.54-1.14; P = .22) between patients who received LRA compared with those who received GA. This also applied to patients presenting with rupture. Receipt of LRA was associated with lower odds of postoperative congestive heart failure (OR, 0.19; 95% CI, 0.01-0.89; P = .01) as well as decreased length of intensive care unit (OR, 0.54; 95% CI, 0.40-0.72; P < .01) and hospital length of stay (OR, 0.64; 95% CI, 0.46-0.84; P < .01). LRA was not associated with decreased long-term survival compared with GA (hazard ratio, 0.95; 95% CI, 0.72-1.25; P = .72). CONCLUSIONS: Despite a greater number of baseline comorbidities, patients undergoing TEVAR with LRA experienced shorter intensive care unit and postoperative lengths of stay, with similar operative outcomes and long-term survival compared with patients who received GA. Similar findings were found among the rupture cohort. LRA should be considered more frequently in select patients undergoing TEVAR.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Anesthesia, General/adverse effects , Aortic Aneurysm, Thoracic/complications , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Humans , Postoperative Complications , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
9.
Curr Opin Cardiol ; 37(6): 439-445, 2022 11 01.
Article in English | MEDLINE | ID: mdl-36004870

ABSTRACT

PURPOSE OF REVIEW: The gold standard treatment for aneurysms and dissections involving the aortic arch remains open total arch replacement. High-risk operative candidates may benefit from hybrid or completely endovascular techniques to reduce the risk of perioperative mortality and morbidity. RECENT FINDINGS: Numerous endografts are available for investigational use in the aortic arch as part of investigational device exemption (IDE) programs. Some are fenestrated or scalloped, whereas others are branched, ranging from single branch to triple branch stent-grafts. Initial results for completely endovascular repair of the aortic arch are encouraging. Current data estimates that rates of successful deployment of arch endografts ranges from 84.2% to 100%, whereas operative mortality may be as high as 13.2%, with stroke rates being as high as 20% and spinal cord ischemia being as high as 3.1%. SUMMARY: More data are necessary to compare hybrid and endovascular stent-grafting of the aortic arch to conventional open total arch replacement. Longitudinal follow-up is also lacking, which will determine the long-term durability of endografts in the aortic arch. However, endovascular repair represents an important opportunity for improving outcomes in high-risk patients with complex aneurysms and dissections of the aortic arch.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/methods , Humans , Postoperative Complications/therapy , Prosthesis Design , Retrospective Studies , Risk Factors , Stents , Time Factors , Treatment Outcome
10.
Catheter Cardiovasc Interv ; 99(3): 869-876, 2022 02.
Article in English | MEDLINE | ID: mdl-34533891

ABSTRACT

OBJECTIVES: To assess the safety profile of redo-TAVR procedures from patients in the transcatheter valve therapy (TVT) Registry. BACKGROUND: The use of transcatheter aortic valves (TAV) to treat previously implanted failing TAVS (TAV-in-TAV) has been an increasingly important topic as indications for TAVR move to younger and lower-risk patients, but data on the safety and efficacy of redo-TAVR is limited. METHODS: Patients undergoing redo-TAVR procedures using the Evolut R, Evolut PRO or Evolut PRO+ valve in the TVT Registry between April 2015 and March 2020 were included. In-hospital, 30-day and 1-year outcomes were analyzed. RESULTS: Redo-TAVR was performed in 292 patients (213 patients received the Evolut R valve and 79 received the Evolut PRO or PRO+ valve). Device success was achieved in 94.5%. In-hospital mortality was 2.1%, stroke occurred in 2.7%, and 77.2% of patients were discharged home. There were no cases of coronary compression/obstruction or myocardial infarction that occurred in index hospitalization. Mean gradient at 30-days was 11.9 ± 6.9 mmHg, and 73.1% had none/trace total aortic regurgitation. CONCLUSIONS: Results from the TVT Registry demonstrate good short-term outcomes after redo-TAVR with the supra-annular, self-expandable Evolut platform. Long-term follow-up is necessary to further expand understanding this complex scenario.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Humans , Prosthesis Design , Registries , Risk Factors , Treatment Outcome
11.
Med Sci Monit ; 28: e937652, 2022 Sep 29.
Article in English | MEDLINE | ID: mdl-36171690

ABSTRACT

BACKGROUND Cardiac surgery triggers acute changes in serum leptin and fibroblast growth factor 21 (FGF-21). Considering their pleiotropic role in inflammation and abnormal glucose metabolism, perseverance of their abnormal serum level can have a long-term impact on recovery and end-organ failures. Long-term dynamics after cardiac surgery are unknown. MATERIAL AND METHODS Serum was collected from 123 patients before cardiac surgery (tbaseline) and 24 h (t24h), 7 days (t7d), and 3 months (t3m) later. Also, interleukin 6 (IL-6) and C-reactive protein (CRP) assessed nonspecific inflammatory responses. Neurodegeneration was gauged with serum amyloid ß1-40 and ß1-42. Demographic and clinical information, including disposition at 28 days and t3m from admission, were collected. RESULTS Serum leptin increased at t24h (leptinbaseline=613+747.9 vs leptin24h=768±718.1; P=0.0083) and decreased at t7d (leptin7d=499.5±540.2; P=0.043). FGF-21 levels increased at t24h and t7d. Cytokines normalized by t3m. Presurgical leptin levels were higher in Asians and were the primary determinant of postoperative leptin changes. Leptin levels were most elevated in patients undergoing aortic valve and arch surgery; the perioperative increase was significant only in patients with mitral valve surgery. Leptin and FGF-21 did not correlate with markers of general inflammation (CRP, IL-6), which partially resolved after t3m. Amyloid ß1-42 at t3m correlated with leptin peak at t24h. Low prehospital FGF-21 level correlated with the incidence of perioperative stroke; postoperative FGF-21 correlated with discharge to facility vs home. CONCLUSIONS Leptin and FGF-21 evolve independently from the inflammatory response in the aftermath of cardiac surgery and correlate with cardiac remodeling and neurodegeneration markers.


Subject(s)
Cardiac Surgical Procedures , Leptin , Biomarkers , C-Reactive Protein/metabolism , Cytokines , Fibroblast Growth Factors , Glucose , Humans , Inflammation , Interleukin-6
12.
Circulation ; 141(19): 1527-1537, 2020 05 12.
Article in English | MEDLINE | ID: mdl-32272848

ABSTRACT

BACKGROUND: This study aimed to compare echocardiographic findings in low-risk patients with severe aortic stenosis after surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR). METHODS: The PARTNER 3 trial (Placement of Aortic Transcatheter Valves) randomized 1000 patients with severe aortic stenosis and low surgical risk to undergo either transfemoral TAVR with the balloon-expandable SAPIEN 3 valve or SAVR. Transthoracic echocardiograms obtained at baseline and at 30 days and 1 year after the procedure were analyzed by a consortium of 2 echocardiography core laboratories. RESULTS: The percentage of moderate or severe aortic regurgitation (AR) was low and not statistically different between the TAVR and SAVR groups at 30 days (0.8% versus 0.2%; P=0.38). Mild AR was more frequent after TAVR than SAVR at 30 days (28.8% versus 4.2%; P<0.001). At 1 year, mean transvalvular gradient (13.7±5.6 versus 11.6±5.0 mm Hg; P=0.12) and aortic valve area (1.72±0.37 versus 1.76±0.42 cm2; P=0.12) were similar in TAVR and SAVR. The percentage of severe prosthesis-patient mismatch at 30 days was low and similar between TAVR and SAVR (4.6 versus 6.3%; P=0.30). Valvulo-arterial impedance (Zva), which reflects total left ventricular hemodynamic burden, was lower with TAVR than SAVR at 1 year (3.7±0.8 versus 3.9±0.9 mm Hg/mL/m2; P<0.001). Tricuspid annulus plane systolic excursion decreased and the percentage of moderate or severe tricuspid regurgitation increased from baseline to 1 year in SAVR but remained unchanged in TAVR. Irrespective of treatment arm, high Zva and low tricuspid annulus plane systolic excursion, but not moderate to severe AR or severe prosthesis-patient mismatch, were associated with increased risk of the composite end point of mortality, stroke, and rehospitalization at 1 year. CONCLUSIONS: In patients with severe aortic stenosis and low surgical risk, TAVR with the SAPIEN 3 valve was associated with similar percentage of moderate or severe AR compared with SAVR but higher percentage of mild AR. Transprosthetic gradients, valve areas, percentage of severe prosthesis-patient mismatch, and left ventricular mass regression were similar in TAVR and SAVR. SAVR was associated with significant deterioration of right ventricular systolic function and greater tricuspid regurgitation, which persisted at 1 year. High Zva and low tricuspid annulus plane systolic excursion were associated with worse outcome at 1 year whereas AR and severe prosthesis-patient mismatch were not. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02675114.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Echocardiography , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Hemodynamics , Humans , Male , North America , Predictive Value of Tests , Prosthesis Design , Prosthesis Failure , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
13.
Am Heart J ; 232: 1-9, 2021 02.
Article in English | MEDLINE | ID: mdl-33214129

ABSTRACT

BACKGROUND: Patients with atrial fibrillation (AF) who have undergone mitral valve repair are at risk for thromboembolic strokes. Prior to 2019, only vitamin K antagonists were recommended for patients with AF who had undergone mitral valve repair despite the introduction of direct oral anticoagulants (DOAC) in 2010. OBJECTIVE: To characterize the use of anticoagulants in patients with AF who underwent surgical mitral valve repair (sMVR) or transcatheter mitral valve repair (tMVR). METHODS: We performed a retrospective cohort analysis of patients with AF undergoing sMVR or tMVR between 04/2014 and 12/2018 using Optum's de-identified Clinformatics® Data Mart Database. We identified anticoagulants prescribed within 90 days of discharge from hospitalization. RESULTS: Overall, 1997 patients with AF underwent valve repair: 1560 underwent sMVR, and 437 underwent tMVR. The mean CHA2DS2-VASc score among all patients was 4.1 (SD 1.9). The overall use of anticoagulation was unchanged between 2014 (72.2%) and 2018 (70.0%) (P = .49). Among patients who underwent sMVR or tMVR between April 2014 and December 2018, the use of VKA therapy decreased from 62.9% to 32.1% (P < .01 for trend) and the use of DOACs increased from 12.4% to 37.3% (P < .01 for trend). CONCLUSIONS: Among patients with AF who underwent sMVR or tMVR between 2014 and 2018, roughly 30% of patients were not treated with any anticoagulant within 90 days of discharge, despite an elevated stroke risk in the cohort. The rate of DOAC use increased steadily over the study period but did not significantly increase the rate of overall anticoagulant use in this high-risk cohort.


Subject(s)
Anticoagulants/therapeutic use , Atrial Fibrillation/drug therapy , Factor Xa Inhibitors/therapeutic use , Mitral Valve Annuloplasty , Mitral Valve Insufficiency/surgery , Stroke/prevention & control , Warfarin/therapeutic use , Aged , Aged, 80 and over , Atrial Fibrillation/complications , Female , Guideline Adherence , Humans , Logistic Models , Male , Middle Aged , Mitral Valve Insufficiency/complications , Postoperative Care , Practice Guidelines as Topic , Stroke/etiology
14.
J Cardiothorac Vasc Anesth ; 35(7): 2144-2154, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33268279

ABSTRACT

Coronary artery bypass grafting is a highly efficacious mode of myocardial revascularization that reduces mortality from ischemic heart disease. The patient presenting after acute myocardial infarction in cardiogenic shock presents a unique challenge. Early revascularization is proven to reduce mortality, but many questions remain, including the optimal mode and extent of revascularization, the role of mechanical circulatory support, and which patients are candidates for surgical intervention. Unprecedented attention to the outcomes of cardiac surgery means decisions about the management of the acute myocardial infarction in cardiogenic shock patients are influenced by risk aversion. The authors here review this topic to arm the reader with a comprehensive understanding of the literature to better guide surgical decision-making and perioperative management.


Subject(s)
Myocardial Infarction , Shock, Cardiogenic , Coronary Artery Bypass , Humans , Myocardial Infarction/complications , Myocardial Infarction/therapy , Myocardial Revascularization , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy , Treatment Outcome
15.
J Card Surg ; 36(11): 4292-4300, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34405439

ABSTRACT

BACKGROUND: Open total arch replacement remains the gold standard treatment for aneurysms and dissections involving the aortic arch. However, high-risk surgical candidates may benefit from endovascular techniques to reduce the risk of perioperative mortality and morbidity, especially neurologic complications. Numerous endografts are available for investigational use in the aortic arch as part of investigational device exemption (IDE) programs. Some devices are fenestrated or scalloped, while others are branched, ranging from single branch to triple branch stent-grafts. Furthermore, chimney techniques and in situ fenestration may be utilized in bailout or emergent situations. RESULTS: Initial results describing outcomes of complete endovascular repair of the aortic arch are encouraging, with current data estimating that technical success ranges from 84.2% to 100%. Moreover, operative mortality may be as high as 13.2%, while neurologic complications also remain common, with stroke rates being as high as 20% and spinal cord ischemia being as high as 3.1%. However, more data are necessary to determine the comparative treatment effect of endovascular stent-grafting of the aortic arch, compared with conventional open and hybrid repairs. Longitudinal follow-up is also lacking, which will determine the long-term durability of endografts in the aortic arch. Nevertheless, endovascular repair represents an important opportunity for improving outcomes in patients with complex and potentially devastating pathologies of the aortic arch.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Humans , Postoperative Complications/epidemiology , Prosthesis Design , Risk Factors , Stents , Treatment Outcome
16.
Curr Heart Fail Rep ; 18(4): 240-251, 2021 08.
Article in English | MEDLINE | ID: mdl-33956313

ABSTRACT

PURPOSE OF REVIEW: Cardiogenic shock represents a very challenging patient population due to the undifferentiated pathologies presenting as cardiogenic shock, difficult decision-making, prognostication, and ever-expanding support options. The role of cardiac surgeons on this team is evolving. RECENT FINDINGS: The implementation of a shock team is associated with improved outcomes in patients with cardiogenic shock. Early deployment of mechanical circulatory support devices may allow an opportunity to rescue these patients. Cardiothoracic surgeons are a critical component of the shock team who can deploy timely mechanical support and surgical intervention in selected patients for optimal outcomes.


Subject(s)
Heart Failure , Heart-Assist Devices , Surgeons , Humans , Shock, Cardiogenic/therapy
17.
J Card Surg ; 35(7): 1410-1413, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32333431

ABSTRACT

OBJECTIVE: There is a paucity of clinical data on critically ill patients with COVID-19 requiring extracorporeal life support. METHODS: A statewide multi-institutional collaborative for COVID-19 patients was utilized to obtain clinical data on the first 10 critically ill COVID-19 patients who required extracorporeal membrane oxygenation (ECMO). RESULTS: Of the first 10 patients that required ECMO for COVID-19, the age ranged from 31 to 62 years with the majority (70%) being men. Seven (70%) had comorbidities. The majority (80%) of patients had known sick contact and exposure to COVID-19 positive patients or traveled to pandemic areas inside the United States within the 2 weeks before symptom onset. None of the patients were healthcare workers. The most common symptoms leading to the presentation were high fever ≥103°F (90%), cough (80%) and dyspnea (70%), followed by fatigue and gastrointestinal symptoms (both 30%), myalgia, loss of taste, pleuritic chest pain, and confusion (all 10%). All patients had bilateral infiltrates on chest X-rays suggestive of interstitial viral pneumonia. All patients were cannulated in the venovenous configuration. Two (20%) patients were successfully liberated from ECMO support after 7 and 10 days, respectively, and one (10%) patient is currently on a weaning course. One patient (10%) died after 9 days on ECMO from multiorgan dysfunction. CONCLUSIONS: These preliminary multi-institutional data from a statewide collaborative offer insight into the clinical characteristics of the first 10 patients requiring ECMO for COVID-19 and their initial clinical course. Greater morbidity and mortality is likely to be seen in these critically ill patients with longer follow-up.


Subject(s)
Coronavirus Infections/epidemiology , Coronavirus Infections/therapy , Critical Illness/therapy , Extracorporeal Membrane Oxygenation/methods , Pneumonia, Viral/epidemiology , Pneumonia, Viral/therapy , Respiratory Distress Syndrome/therapy , Adult , COVID-19 , Cause of Death , Cohort Studies , Coronavirus Infections/diagnosis , Critical Illness/mortality , Extracorporeal Membrane Oxygenation/mortality , Female , Follow-Up Studies , Hospital Mortality/trends , Humans , Male , Middle Aged , Pandemics , Pneumonia, Viral/diagnosis , Respiratory Distress Syndrome/mortality , Respiratory Distress Syndrome/virology , Retrospective Studies , Risk Assessment , Treatment Outcome , United States
18.
Circulation ; 137(4): 388-399, 2018 01 23.
Article in English | MEDLINE | ID: mdl-29358344

ABSTRACT

Bioprostheses are prone to structural valve degeneration, resulting in limited long-term durability. A significant challenge when comparing the durability of different types of bioprostheses is the lack of a standardized terminology for the definition of a degenerated valve. This issue becomes especially important when we try to compare the degeneration rate of surgically inserted and transcatheter bioprosthetic valves. This document, by the VIVID (Valve-in-Valve International Data), proposes practical and standardized definitions of valve degeneration and provides recommendations for the timing of clinical and imaging follow-up assessments accordingly. Its goal is to improve the quality of research and clinical care for patients with deteriorated bioprostheses by providing objective and strict criteria that can be utilized in future clinical trials. We hope that the adoption of these criteria by both the cardiological and surgical communities will lead to improved comparability and interpretation of durability analyses.


Subject(s)
Bioprosthesis/classification , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis/classification , Heart Valves/surgery , Prosthesis Failure , Terminology as Topic , Transcatheter Aortic Valve Replacement/instrumentation , Device Removal , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/physiopathology , Heart Valve Prosthesis Implantation/adverse effects , Heart Valves/diagnostic imaging , Heart Valves/physiopathology , Humans , Predictive Value of Tests , Prosthesis Design , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
19.
N Engl J Med ; 374(17): 1609-20, 2016 04 28.
Article in English | MEDLINE | ID: mdl-27040324

ABSTRACT

BACKGROUND: Previous trials have shown that among high-risk patients with aortic stenosis, survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. We evaluated the two procedures in a randomized trial involving intermediate-risk patients. METHODS: We randomly assigned 2032 intermediate-risk patients with severe aortic stenosis, at 57 centers, to undergo either TAVR or surgical replacement. The primary end point was death from any cause or disabling stroke at 2 years. The primary hypothesis was that TAVR would not be inferior to surgical replacement. Before randomization, patients were entered into one of two cohorts on the basis of clinical and imaging findings; 76.3% of the patients were included in the transfemoral-access cohort and 23.7% in the transthoracic-access cohort. RESULTS: The rate of death from any cause or disabling stroke was similar in the TAVR group and the surgery group (P=0.001 for noninferiority). At 2 years, the Kaplan-Meier event rates were 19.3% in the TAVR group and 21.1% in the surgery group (hazard ratio in the TAVR group, 0.89; 95% confidence interval [CI], 0.73 to 1.09; P=0.25). In the transfemoral-access cohort, TAVR resulted in a lower rate of death or disabling stroke than surgery (hazard ratio, 0.79; 95% CI, 0.62 to 1.00; P=0.05), whereas in the transthoracic-access cohort, outcomes were similar in the two groups. TAVR resulted in larger aortic-valve areas than did surgery and also resulted in lower rates of acute kidney injury, severe bleeding, and new-onset atrial fibrillation; surgery resulted in fewer major vascular complications and less paravalvular aortic regurgitation. CONCLUSIONS: In intermediate-risk patients, TAVR was similar to surgical aortic-valve replacement with respect to the primary end point of death or disabling stroke. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.).


Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Female , Heart Valve Prosthesis Implantation/mortality , Humans , Kaplan-Meier Estimate , Male , Multivariate Analysis , Postoperative Complications/mortality , Risk Factors , Stroke/etiology , Stroke/mortality , Ultrasonography
20.
Circulation ; 136(22): 2132-2140, 2017 Nov 28.
Article in English | MEDLINE | ID: mdl-28864443

ABSTRACT

BACKGROUND: Conscious sedation is used during transcatheter aortic valve replacement (TAVR) with limited evidence as to the safety and efficacy of this practice. METHODS: The National Cardiovascular Data Registry Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry was used to characterize the anesthesia choice and clinical outcomes of all US patients undergoing elective percutaneous transfemoral TAVR between April 1, 2014, and June 30, 2015. Raw and inverse probability of treatment-weighted analyses were performed to compare patients undergoing TAVR with general anesthesia with patients undergoing TAVR with conscious sedation on an intention-to-treat basis for the primary outcome of in-hospital mortality, and secondary outcomes including 30-day mortality, in-hospital and 30-day death/stroke, procedural success, intensive care unit and hospital length-of-stay, and rates of discharge to home. Post hoc falsification end point analyses were performed to evaluate for residual confounding. RESULTS: Conscious sedation was used in 1737/10 997 (15.8%) cases with a significant trend of increasing usage over the time period studied (P for trend<0.001). In raw analyses, intraprocedural success with conscious sedation and general anesthesia was similar (98.2% versus 98.5%, P=0.31). The conscious sedation group was less likely to experience in-hospital (1.6% versus 2.5%, P=0.03) and 30-day death (2.9% versus 4.1%, P=0.03). Conversion from conscious sedation to general anesthesia was noted in 102 of 1737 (5.9%) of conscious sedation cases. After inverse probability of treatment-weighted adjustment for 51 covariates, conscious sedation was associated with lower procedural success (97.9% versus 98.6%, P<0.001) and a reduced rate of mortality at the in-hospital (1.5% versus 2.4%, P<0.001) and 30-day (2.3% versus 4.0%, P<0.001) time points. Conscious sedation was associated with reductions in procedural inotrope requirement, intensive care unit and hospital length of stay (6.0 versus 6.5 days, P<0.001), and combined 30-day death/stroke rates (4.8% versus 6.4%, P<0.001). Falsification end point analyses of vascular complications, bleeding, and new pacemaker/defibrillator implantation demonstrated no significant differences between groups after adjustment. CONCLUSIONS: In US practice, conscious sedation is associated with briefer length of stay and lower in-hospital and 30-day mortality in comparison with TAVR with general anesthesia in both unadjusted and adjusted analyses. These results suggest the safety of conscious sedation in this population, although comparative effectiveness analyses using observational data cannot definitively establish the superiority of one technique over another.


Subject(s)
Anesthesia, General , Aortic Valve Stenosis/therapy , Conscious Sedation , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Anesthesia, General/adverse effects , Anesthesia, General/mortality , Anesthesia, General/trends , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Comparative Effectiveness Research , Conscious Sedation/adverse effects , Conscious Sedation/mortality , Conscious Sedation/trends , Female , Hospital Mortality , Humans , Intention to Treat Analysis , Length of Stay , Male , Patient Discharge , Practice Patterns, Physicians'/trends , Registries , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/trends , Treatment Outcome , United States
SELECTION OF CITATIONS
SEARCH DETAIL