ABSTRACT
Real-time monitoring of heart rate is useful for monitoring workers. Wearable heart rate monitors worn on the upper body are less susceptible to artefacts caused by arm and wrist movements than popular wristband-type sensors using the photoplethysmography method. Therefore, they are considered suitable for stable and accurate measurement for various movements. In this study, we conducted an experiment to verify the accuracy of our developed and commercially available wearable heart rate monitor consisting of a smart shirt with bioelectrodes and a transmitter, assuming a real-world work environment with physical loads. An exercise protocol was designed to light to moderate intensity according to international standards because no standard exercise protocol for the validation simulating these works has been reported. This protocol includes worker-specific movements such as applying external vibration and lifting and lowering loads. In the experiment, we simultaneously measured the instantaneous heart rate with the above wearable device and a Holter monitor as a reference to evaluate mean absolute percentage error (MAPE). The MAPE was 0.92% or less for all exercise protocols conducted. This value indicates that the accuracy of the wearable device is high enough for use in real-world cases of physical load in light to moderate intensity tasks such as those in our experimental protocol. In addition, the experimental protocol and measurement data devised in this study can be used as a benchmark for other wearable heart rate monitors for use for similar purposes.
Subject(s)
Heart Rate Determination , Wearable Electronic Devices , Humans , Heart Rate , Photoplethysmography , Electrocardiography, AmbulatoryABSTRACT
Recent studies of saccharides' peculiar anti-freezing and anti-dehydration properties point to a close association with their strong hydration capability and destructuring effect on the hydrogen bond (HB) network of bulk water. The underlying mechanisms are, however, not well understood. In this respect, examination of the complex dielectric constants of saccharide aqueous solutions, especially over a broadband frequency region, should provide interesting insights into these properties, since the dielectric responses reflect corresponding dynamics over the time scales measured. In order to do this, the complex dielectric constants of glucose solutions between 0.5 GHz and 12 THz (from the microwave to the far-infrared region) were measured. We then performed analysis procedures on this broadband spectrum by decomposing it into four Debye and two Lorentz functions, with particular attention being paid to the ß relaxation (glucose tumbling), δ relaxation (rotational polarization of the hydrated water), slow relaxation (reorientation of the HB network water), fast relaxation (rotation of the non-HB water), and intermolecular stretching vibration (hindered translation of water). On the basis of this analysis, we revealed that the hydrated water surrounding the glucose molecules exhibits a mono-modal relaxational dispersion with 2-3 times slower relaxation times than unperturbed bulk water and with a hydration number of around 20. Furthermore, other species of water with distorted tetrahedral HB water structures, as well as increases in the relative proportion of non-HB water molecules which have a faster relaxation time and are not a part of the surrounding bulk water HB network, was found in the vicinity of the glucose molecules. These clearly point to the HB destructuring effect of saccharide solutes in aqueous solution. The results, as a whole, provide a detailed picture of glucose-water and water-water interactions in the vicinity of the glucose molecules at various time scales from sub-picosecond to hundreds of picoseconds.
Subject(s)
Glucose/chemistry , Solvents/chemistry , Water/chemistry , Dielectric Spectroscopy , Hydrogen Bonding , SolutionsABSTRACT
An electrocardiogram (ECG) is used to observe the electrical activity of the heart via electrodes on the body surface. Recently, an ECG with fewer electrodes, such as a bipolar ECG in which two electrodes are attached to the chest, has been employed as wearable devices. However, the effect of different geometrical factors and electrode-pair locations on the amplitude and waveform of ECG signals remains unclear. In this study, we computationally evaluated the effects of body morphology, heart size and orientation, and electrode misalignment on ECG signals for 48 scenarios using 35 bipolar electrode pairs (1680 waveforms) with a dynamic time warping (DTW) algorithm. It was observed that the physique of the human body model predominantly affected the amplitude and waveform of the ECG signals. A multivariate analysis indicated that the heart-electrode distance and the solid angle of the heart from the electrode characterized the amplitude and waveform of the ECG signals, respectively. Furthermore, the electrode locations for less individual variability and less waveform distortion were close to the location of electrodes V2 and V3 in the standard 12-lead. These findings will facilitate the placement of ECG electrodes and interpretation of the measured ECG signals for wearable devices.
Subject(s)
Electrocardiography , Wearable Electronic Devices , Humans , Algorithms , ElectrodesABSTRACT
Acceleration sensors are widely used in consumer wearable devices and smartphones. Postures estimated from recorded accelerations are commonly used as features indicating the activities of patients in medical studies. However, recording for over 24 h is more likely to result in data losses than recording for a few hours, especially when consumer-grade wearable devices are used. Here, to impute postures over a period of 24 h, we propose an imputation method that uses ensemble averaging. This method outputs a time series of postures over 24 h with less lost data by calculating the ratios of postures taken at the same time of day during several measurement-session days. Whereas conventional imputation methods are based on approaches with groups of subjects having multiple variables, the proposed method imputes the lost data variables individually and does not require other variables except posture. We validated the method on 306 measurement data from 99 stroke inpatients in a hospital rehabilitation ward. First, to classify postures from acceleration data measured by a wearable sensor placed on the patient's trunk, we preliminary estimated possible thresholds for classifying postures as 'reclining' and 'sitting or standing' by investigating the valleys in the histogram of occurrences of trunk angles during a long-term recording. Next, the imputations of the proposed method were validated. The proposed method significantly reduced the missing data rate from 5.76% to 0.21%, outperforming a conventional method.
ABSTRACT
Temperature elevation due to global warming increases the risks of dehydration, which can induce heat-related illness. Proper rehydration with appropriate amounts of water and electrolytes is essential to aid body fluid homeostasis. Wearable sweat sensors which can monitor both the sweat rate and sweat electrolyte concentration may be an effective tool for determining appropriate rehydration. Here, we developed a novel potentially wearable sensor that can monitor both the local sweat rate and sweat electrolyte concentration continuously. The new device includes a system with a short microfluidic pathway that guides the sweat appearing on the skin to a small space in the device to form a quantifiable droplet. The sweat rate is assessed from the time for the droplet to appear and droplet volume, while an integrated electric sensor detects the sodium chloride concentration in each sweat droplet. We demonstrated that this new device could record both the flow rates of artificial sweat and its sodium chloride concentration in ranges of human sweating with an accuracy within ±10%. This is equivalent to the accuracy of commercially available sweat rate meters and sweat ion sensors. The present study provides a new perspective for the design of wearable sensors that can continuously monitor sweat rates and sweat electrolyte concentrations for potential application to a healthcare device.
ABSTRACT
The last century has seen a gradual increase in global average temperatures-a phenomenon that has come to be known as global warming. The World Meteorological Organization (WMO) has reported that 2020 was one of the three warmest years on record and that the global average temperature was ~1.2°C above preindustrial (1850-1900) levels [1]. Adverse effects on health resulting from global warming are important issues to consider, as health risks associated with such extreme heat are anticipated [2]. In fact, this warming has been shown to severely limit human activity in tropical and mid-latitude regions [3], and in particular, outdoor and manual workers who are exposed to ambient heat during working hours are susceptible to increased health risks. Thus, workers should pay attention to their own physical conditions and proactively keep out of the heat to rest when uncomfortable. Additionally, supervisors must manage worker's physical conditions and schedule regular breaks. Therefore, in this trial a new integrated system was developed to notify individuals at risk based on their thermal physiology. This method uses biological and environmental information obtained directly via wearable sensors and the estimated body core temperature collected on-ground cannot be measured wirelessly and noninvasively [4].
Subject(s)
Heat Stress Disorders , Hot Temperature/adverse effects , Monitoring, Physiologic , Occupational Health , Body Temperature , Global Warming , Humans , Risk Assessment , Wearable Electronic DevicesABSTRACT
Athletes in all sports face injury or illness if they train too much. Therefore, it is crucial for them to manage their training load. Monitoring the heart rate is one way to estimate training load. However, there are limitations to a monitor's measurement ability in contact sports like rugby. Another method to estimate training load in contact sports is the rating of perceived exertion of a player, which is based on a questionnaire. It however takes a long time to obtain answers to questionnaires in team sports. As a solution to this problem, we developed a wearable heart rate monitor for rugby players. The garment-type monitor with flank electrodes can measure the heart rate even in rugby training situations. We also propose a method to estimate the training load from the measured heart rate. The method can be used instead of a questionnaire administered to the players and can reduce the labor in the estimation of the training load.
Subject(s)
Football , Heart Rate , Monitoring, Physiologic/instrumentation , Physical Conditioning, Human , Wearable Electronic Devices , Athletes , Electrodes , Humans , WorkloadABSTRACT
In order to understand the internal phenomena in a microwave discharge ion thruster, it is important to measure the distribution of the microwave electric field inside the discharge chamber, which is directly related to the plasma production. In this study, we proposed a novel method of measuring a microwave electric field with an electro-optic (EO) probe based on the Pockels effect. The probe, including a cooling system, contains no metal and can be accessed in the discharge chamber with less disruption to the microwave distribution. This method enables measurement of the electric field profile under ion beam acceleration. We first verified the measurement with the EO probe by a comparison with a finite-difference time domain numerical simulation of the microwave electric field in atmosphere. Second, we showed that the deviations of the reflected microwave power and the beam current were less than 8% due to inserting the EO probe into the ion thruster under ion beam acceleration. Finally, we successfully demonstrated the measurement of the electric-field profile in the ion thruster under ion beam acceleration. These measurements show that the electric field distribution in the thruster dramatically changes in the ion thruster under ion beam acceleration as the propellant mass flow rate increases. These results indicate that this new method using an EO probe can provide a useful guide for improving the propulsion of microwave discharge ion thrusters.