Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
1.
Arch Toxicol ; 92(4): 1593-1608, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29411056

ABSTRACT

Although the value of the regulatory accepted batteries for in vitro genotoxicity testing is recognized, they result in a high number of false positives. This has a major impact on society and industries developing novel compounds for pharmaceutical, chemical, and consumer products, as afflicted compounds have to be (prematurely) abandoned or further tested on animals. Using the metabolically competent human HepaRG™ cell line and toxicogenomics approaches, we have developed an upgraded, innovative, and proprietary gene classifier. This gene classifier is based on transcriptomic changes induced by 12 genotoxic and 12 non-genotoxic reference compounds tested at sub-cytotoxic concentrations, i.e., IC10 concentrations as determined by the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay. The resulting gene classifier was translated into an easy-to-handle qPCR array that, as shown by pathway analysis, covers several different cellular processes related to genotoxicity. To further assess the predictivity of the tool, a set of 5 known positive and 5 known negative test compounds for genotoxicity was evaluated. In addition, 2 compounds with debatable genotoxicity data were tested to explore how the qPCR array would classify these. With an accuracy of 100%, when equivocal results were considered positive, the results showed that combining HepaRG™ cells with a genotoxin-specific qPCR array can improve (geno)toxicological hazard assessment. In addition, the developed qPCR array was able to provide additional information on compounds for which so far debatable genotoxicity data are available. The results indicate that the new in vitro tool can improve human safety assessment of chemicals in general by basing predictions on mechanistic toxicogenomics information.


Subject(s)
DNA Damage , Mutagenicity Tests/methods , Mutagens/toxicity , Real-Time Polymerase Chain Reaction/methods , Cell Line , Humans , Toxicogenetics
2.
Mutagenesis ; 31(4): 453-61, 2016 07.
Article in English | MEDLINE | ID: mdl-26980085

ABSTRACT

Prior to the downstream development of chemical substances, including pharmaceuticals and cosmetics, their influence on the genetic apparatus has to be tested. Several in vitro and in vivo assays have been developed to test for genotoxicity. In a first tier, a battery of two to three in vitro tests is recommended to cover mutagenicity, clastogenicity and aneugenicity as main endpoints. This regulatory in vitro test battery is known to have a high sensitivity, which is at the expense of the specificity. The high number of false positive in vitro results leads to excessive in vivo follow-up studies. In the case of cosmetics it may even induce the ban of the particular compound since in Europe the use of experimental animals is no longer allowed for cosmetics. In this article, an alternative approach to derisk a misleading positive Ames test is explored. Hereto we first tested the performance of five existing computational tools to predict the potential mutagenicity of a data set of 132 cosmetic compounds with a known genotoxicity profile. Furthermore, we present, as a proof-of-principle, a strategy in which a combination of computational tools and mechanistic information derived from in vitro transcriptomics analyses is used to derisk a misleading positive Ames test result. Our data shows that this strategy may represent a valuable tool in a weight-of-evidence approach to further evaluate a positive outcome in an Ames test.


Subject(s)
Computer Simulation , Gene Expression Profiling/methods , Mutagenicity Tests/methods , Computational Biology/methods , Cosmetics , Data Accuracy , Sensitivity and Specificity
3.
Environ Mol Mutagen ; 65(1-2): 4-24, 2024.
Article in English | MEDLINE | ID: mdl-38545858

ABSTRACT

ToxTracker is a mammalian cell reporter assay that predicts the genotoxic properties of compounds with high accuracy. By evaluating induction of various reporter genes that play a key role in relevant cellular pathways, it provides insight into chemical mode-of-action (MoA), thereby supporting discrimination of direct-acting genotoxicants and cytotoxic chemicals. A comprehensive interlaboratory validation trial was conducted, in which the principles outlined in OECD Guidance Document 34 were followed, with the primary objectives of establishing transferability and reproducibility of the assay and confirming the ability of ToxTracker to correctly classify genotoxic and non-genotoxic compounds. Reproducibility of the assay to predict genotoxic MoA was confirmed across participating laboratories and data were evaluated in terms of concordance with in vivo genotoxicity outcomes. Seven laboratories tested a total of 64 genotoxic and non-genotoxic chemicals that together cover a broad chemical space. The within-laboratory reproducibility (WLR) was up to 98% (73%-98% across participants) and the overall between-laboratory reproducibility (BLR) was 83%. This trial confirmed the accuracy of ToxTracker to predict in vivo genotoxicants with a sensitivity of 84.4% and a specificity of 91.2%. We concluded that ToxTracker is a robust in vitro assay for the accurate prediction of in vivo genotoxicity. Considering ToxTracker's robust standalone accuracy and that it can provide important information on the MoA of chemicals, it is seen as a valuable addition to the regulatory in vitro genotoxicity battery that may even have the potential to replace certain currently used in vitro battery assays.


Subject(s)
DNA Damage , Mammals , Animals , Humans , Mutagenicity Tests , Reproducibility of Results , Genes, Reporter
4.
Mutat Res ; 744(1): 111-6, 2012 Apr 11.
Article in English | MEDLINE | ID: mdl-22342612

ABSTRACT

Two year rodent bioassays play a key role in the assessment of carcinogenic potential of chemicals to humans. The seventh amendment to the European Cosmetics Directive will ban in 2013 the marketing of cosmetic and personal care products that contain ingredients that have been tested in animal models. Thus 2-year rodent bioassays will not be available for cosmetics/personal care products. Furthermore, for large testing programs like REACH, in vivo carcinogenicity testing is impractical. Alternative ways to carcinogenicity assessment are urgently required. In terms of standardization and validation, the most advanced in vitro tests for carcinogenicity are the cell transformation assays (CTAs). Although CTAs do not mimic the whole carcinogenesis process in vivo, they represent a valuable support in identifying transforming potential of chemicals. CTAs have been shown to detect genotoxic as well as non-genotoxic carcinogens and are helpful in the determination of thresholds for genotoxic and non-genotoxic carcinogens. The extensive review on CTAs by the OECD (OECD (2007) Environmental Health and Safety Publications, Series on Testing and Assessment, No. 31) and the proven within- and between-laboratories reproducibility of the SHE CTAs justifies broader use of these methods to assess carcinogenic potential of chemicals.


Subject(s)
Carcinogenicity Tests/methods , Cell Transformation, Neoplastic , Cosmetics/toxicity , Drug and Narcotic Control/legislation & jurisprudence , Drug-Related Side Effects and Adverse Reactions , Food Safety , Toxicology/legislation & jurisprudence , Animal Testing Alternatives/methods , Animals , Carcinogens/toxicity , Mutagenicity Tests , Toxicology/methods
5.
Mutat Res ; 744(1): 12-9, 2012 Apr 11.
Article in English | MEDLINE | ID: mdl-22138617

ABSTRACT

The potential for a compound to induce carcinogenicity is a key consideration when ascertaining hazard and risk assessment of chemicals. Among the in vitro alternatives that have been developed for predicting carcinogenicity, in vitro cell transformation assays (CTAs) have been shown to involve a multistage process that closely models important stages of in vivo carcinogenesis and have the potential to detect both genotoxic and non-genotoxic carcinogens. These assays have been in use for decades and a substantial amount of data demonstrating their performance is available in the literature. However, for the standardised use of these assays for regulatory purposes, a formal evaluation of the assays, in particular focusing on development of standardised transferable protocols and further information on assay reproducibility, was considered important to serve as a basis for the drafting of generally accepted OECD test guidelines. To address this issue, a prevalidation study of the CTAs using the BALB/c 3T3 cell line, SHE cells at pH 6.7, and SHE cells at pH 7.0 was coordinated by the European Centre for the Validation of Alternative Methods (ECVAM) and focused on issues of standardisation of protocols, test method transferability and within- and between-laboratory reproducibility. The study resulted in the availability of standardised protocols that had undergone prevalidation [1,2]. The results of the ECVAM study demonstrated that for the BALB/c 3T3 method, some modifications to the protocol were needed to obtain reproducible results between laboratories, while the SHE pH 6.7 and the SHE pH 7.0 protocols are transferable between laboratories, and results are reproducible within- and between-laboratories. It is recommended that the BALB/c 3T3 and SHE protocols as instituted in this prevalidation study should be used in future applications of these respective transformation assays. To support their harmonised use and regulatory application, the development of an OECD test guideline for the SHE CTAs, based on the protocol published in this issue, is recommended. The development of an OECD test guideline for the BALB/c 3T3 CTA should likewise be further pursued upon the availability of additional supportive data and improvement of the statistical analysis.


Subject(s)
Animal Testing Alternatives/methods , Carcinogenicity Tests/methods , Cell Transformation, Neoplastic , Animal Testing Alternatives/standards , Animals , BALB 3T3 Cells , Carcinogenicity Tests/standards , Carcinogens/toxicity , Cricetinae , Mesocricetus , Mice , Reproducibility of Results , Validation Studies as Topic
6.
Regul Toxicol Pharmacol ; 62(2): 393-403, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22085589

ABSTRACT

Validated in vitro methods for skin corrosion and irritation were adopted by the OECD and by the European Union during the last decade. In the EU, Switzerland and countries adopting the EU legislation, these assays may allow the full replacement of animal testing for identifying and classifying compounds as skin corrosives, skin irritants, and non irritants. In order to develop harmonised recommendations on the use of in vitro data for regulatory assessment purposes within the European framework, a workshop was organized by the Swiss Federal Office of Public Health together with ECVAM and the BfR. It comprised stakeholders from various European countries involved in the process from in vitro testing to the regulatory assessment of in vitro data. Discussions addressed the following questions: (1) the information requirements considered useful for regulatory assessment; (2) the applicability of in vitro skin corrosion data to assign the corrosive subcategories as implemented by the EU Classification, Labelling and Packaging Regulation; (3) the applicability of testing strategies for determining skin corrosion and irritation hazards; and (4) the applicability of the adopted in vitro assays to test mixtures, preparations and dilutions. Overall, a number of agreements and recommendations were achieved in order to clarify and facilitate the assessment and use of in vitro data from regulatory accepted methods, and ultimately help regulators and scientists facing with the new in vitro approaches to evaluate skin irritation and corrosion hazards and risks without animal data.


Subject(s)
Caustics/toxicity , Irritants/toxicity , Risk Assessment/legislation & jurisprudence , Skin/drug effects , Animal Testing Alternatives , Animals , European Union , Female , Male , Switzerland
7.
Mutat Res ; 721(1): 27-73, 2011 Mar 18.
Article in English | MEDLINE | ID: mdl-21238603

ABSTRACT

In vitro genotoxicity testing needs to include tests in both bacterial and mammalian cells, and be able to detect gene mutations, chromosomal damage and aneuploidy. This may be achieved by a combination of the Ames test (detects gene mutations) and the in vitro micronucleus test (MNvit), since the latter detects both chromosomal aberrations and aneuploidy. In this paper we therefore present an analysis of an existing database of rodent carcinogens and a new database of in vivo genotoxins in terms of the in vitro genotoxicity tests needed to detect their in vivo activity. Published in vitro data from at least one test system (most were from the Ames test) were available for 557 carcinogens and 405 in vivo genotoxins. Because there are fewer publications on the MNvit than for other mammalian cell tests, and because the concordance between the MNvit and the in vitro chromosomal aberration (CAvit) test is so high for clastogenic activity, positive results in the CAvit test were taken as indicative of a positive result in the MNvit where there were no, or only inadequate data for the latter. Also, because Hprt and Tk loci both detect gene-mutation activity, a positive Hprt test was taken as indicative of a mouse-lymphoma Tk assay (MLA)-positive, where there were no data for the latter. Almost all of the 962 rodent carcinogens and in vivo genotoxins were detected by an in vitro battery comprising Ames+MNvit. An additional 11 carcinogens and six in vivo genotoxins would apparently be detected by the MLA, but many of these had not been tested in the MNvit or CAvit tests. Only four chemicals emerge as potentially being more readily detected in MLA than in Ames+MNvit--benzyl acetate, toluene, morphine and thiabendazole--and none of these are convincing cases to argue for the inclusion of the MLA in addition to Ames+MNvit. Thus, there is no convincing evidence that any genotoxic rodent carcinogens or in vivo genotoxins would remain undetected in an in vitro test battery consisting of Ames+MNvit.


Subject(s)
Carcinogenicity Tests/methods , Carcinogens/toxicity , Mutagenicity Tests/methods , Mutagens/toxicity , Animals , DNA Damage , Databases, Factual , Micronucleus Tests/methods , Rodentia/genetics , Salmonella typhimurium/genetics , Sensitivity and Specificity
8.
Mutat Res ; 680(1-2): 31-42, 2009.
Article in English | MEDLINE | ID: mdl-19765670

ABSTRACT

In vivo genetic toxicology tests measure direct DNA damage or the formation of gene or chromosomal mutations, and are used to predict the mutagenic and carcinogenic potential of compounds for regulatory purposes and/or to follow-up positive results from in vitro testing. These tests are widely used and consume large numbers of animals, with a foreseeable marked increase as a result of the EU chemicals legislation (REACH), which may require follow-up of any positive outcome in the in vitro standard battery with appropriate in vivo tests, regardless of the tonnage level of the chemical. A 2-day workshop with genotoxicity experts from academia, regulatory agencies and industry was hosted by the European Centre for the Validation of Alternative Methods (ECVAM) in Ranco, Italy from 24 to 25 June 2008. The objectives of the workshop were to discuss how to reduce the number of animals in standard genotoxicity tests, whether the application of smarter test strategies can lead to lower animal numbers, and how the possibilities for reduction can be promoted and implemented. The workshop agreed that there are many reduction options available that are scientifically credible and therefore ready for use. Most of these are compliant with regulatory guidelines, i.e. the use of one sex only, one administration and two sampling times versus two or three administrations and one sampling time for micronucleus (MN), chromosomal aberration (CA) and Comet assays; and the integration of the MN endpoint into repeat-dose toxicity studies. The omission of a concurrent positive control in routine CA and MN tests has been proven to be scientifically acceptable, although the OECD guidelines still require this; also the combination of acute MN and Comet assay studies are compliant with guidelines, except for sampling times. Based on the data presented at the workshop, the participants concluded that these options have not been sufficiently utilized to date. Key factors for this seem to be the uncertainty regarding regulatory compliance/acceptance, lack of awareness, and an in many cases unjustified uncertainty regarding the scientific acceptance of reduction options. The workshop therefore encourages the use and promotion of these options as well as the dissemination of data related to reduction opportunities by the scientific community in order to boost the acceptance level of these approaches. Furthermore, experimental proof is needed and under way to demonstrate the credibility of additional options for reduction of the number of animals, such as the integration of the Comet assay into repeat-dose toxicity studies.


Subject(s)
Animal Testing Alternatives/legislation & jurisprudence , Animal Welfare/legislation & jurisprudence , Mutagens/toxicity , Research Design/legislation & jurisprudence , Toxicity Tests , Animals , DNA Damage , European Union , Female , Government Agencies , Male , Mutagenicity Tests/standards , Mutagens/classification , Research Design/standards , Toxicity Tests/ethics , Toxicity Tests/methods , Toxicity Tests/standards
9.
Mutagenesis ; 23(4): 271-83, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18326866

ABSTRACT

In the past decade several studies comparing the in vitro chromosome aberration test (CAT) and the in vitro micronucleus test (MNT) were performed. A high correlation was observed in each of the studies (>85%); however, no formal validation for the micronucleus in vitro assay had been carried out. Therefore, a working group was established by the European Centre for the Validation of Alternative Methods (ECVAM) to perform a retrospective validation of the existing data, in order to evaluate the validity of the in vitro MNT on the basis of the modular validation approach. The primary focus of this retrospective validation was on the evaluation of the potential of the in vitro MNT as alternative to the standard in vitro CAT. The working group evaluated, in a first step, the available published data and came to the conclusion that two studies [German ring trial, von der Hude, W., Kalweit, S., Engelhardt, G. et al. (2000) In-vitro micronucleus assay with Chinese hamster V79 cells: results of a collaborative study with 26 chemicals. Mutat. Res., 468, 137-163, and SFTG International Collaborative Study, Lorge, E., Thybaud, V., Aardema, M., Oliver, J., Wataka, A., Lorenzon, G. and Marzin, D. (2006) SFTG International Collaborative Study on in-vitro micronucleus test I. General conditions and overall conclusions of the study. Mutat. Res., 607, 13-36] met the criteria for a retrospective validation according to the criteria previously defined by the working group. These two studies were evaluated in depth (including the reanalysis of raw data) and provided the information required for assessing the reliability (reproducibility) of the test. For the assessment of the concordance between the in vitro MNT and the in vitro CAT, additional published data were considered. Based on this retrospective validation, the ECVAM Validation Management Team concluded that the in vitro MNT is reliable and relevant and can therefore be used as an alternative method to the in vitro CAT. Following peer review, these conclusions were formally endorsed by the ECVAM Scientific Advisory Committee.


Subject(s)
Micronucleus Tests/methods , Animals , CHO Cells , Cells, Cultured , Cricetinae , Cricetulus , Europe , Humans , Mice , Micronucleus Tests/standards , Reproducibility of Results , Retrospective Studies , Societies, Scientific , Technology Transfer
10.
Toxicol In Vitro ; 22(8): 1948-56, 2008 Dec.
Article in English | MEDLINE | ID: mdl-18845236

ABSTRACT

The embryonic stem cell test (EST) is an ECVAM-validated assay to detect embryotoxicity. The output of the assay is the effect of test compounds on the differentiation of murine-derived embryonic stem cells (D3 cells), recorded by visual analysis of contracting cardiomyocyte-like cells. Incorporation of a system to assess the contractility in an automated manner is proposed, to increase the throughput in the EST independent of observer bias. The automated system is based on image recording of each well, resulting in the area (pixels) and frequency of contractility (Hz). Four test compounds were assessed for their embryotoxic potency in the 96-well version of the EST, with both manual and automated analysis: 6-Aminonicotinamide, Valproic Acid, Boric Acid, and Penicillin G. There was no statistically significant difference in the outcome of both methods in the fraction of contractility (p<0.05), resulting in the same rank-order of Relative Embryotoxic Potency (REP) values: 6-aminonicotinamide (1)>valproic acid (0.007-0.013)>Boric Acid (0.002-0.005)>Penicillin G (0.00001). The automated image recording of contractile cardiomyocyte-like cells in the EST allows for an unbiased high throughput method to assess the embryotoxic potency of test compounds, resulting in an outcome comparable to manual analysis.


Subject(s)
Cell Differentiation/drug effects , Embryonic Stem Cells/drug effects , Teratogens/toxicity , Toxicity Tests/methods , Animals , Automation , Cell Culture Techniques , Mice , Myocardial Contraction/drug effects , Myocytes, Cardiac/drug effects , Myocytes, Cardiac/metabolism , Observer Variation
11.
Toxicol In Vitro ; 22(7): 1789-96, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18672049

ABSTRACT

In order to support drug research in the selection process for non-embryotoxic pharmaceutical compounds, a screening method for embryotoxicity is needed. The murine embryonic stem cell test (EST) is a validated in vitro test based on two permanent mouse cell lines and delivering results in 10-days. Implementation of this test within our laboratory, revealed variability in the differentiation potential of the embryonic stem cells and, as a consequence, a lot of assays needed to be rejected due the fact the acceptance criteria were not reached. In order to gain a better yield of contracting myocardial cells, we used (1) a stringent control of the cell growth during subcultivation and a standardised hanging drop culture method and (2) a non-enzymatic cell harvest instead of a trypsin/EDTA cell harvest. Implementing of these cell culture modifications resulted in a decreased variability in the size of embryonic bodies, an increase of the number of acceptable tests and a significant increase of the differentiation potential of embryonic cells into strong beating myocardium, which made scoring less time consuming. Testing of 6 reference compounds in the optimized EST showed that the cell culture modifications did not changed the in vitro classification.


Subject(s)
Cell Culture Techniques/methods , Cell Differentiation/drug effects , Embryonic Stem Cells/drug effects , Toxicity Tests/methods , Animals , BALB 3T3 Cells , Edetic Acid/metabolism , Embryonic Stem Cells/metabolism , Mice , Myocardium/cytology , Trypsin/metabolism
12.
Birth Defects Res B Dev Reprod Toxicol ; 83(4): 446-56, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18702117

ABSTRACT

A meeting was convened so that users of three models for in vitro developmental toxicity (embryonic stem cells, whole embryo culture, and zebrafish) could share their experiences with each model, and explore the areas for improvement. We present a summary of this meeting and the recommendations of the group.


Subject(s)
Embryo Culture Techniques/methods , Embryonic Stem Cells/cytology , Toxicity Tests/methods , Zebrafish/embryology , Animals , Embryo, Mammalian/cytology , Embryo, Nonmammalian/cytology , Mice
14.
Mutat Res ; 628(1): 31-55, 2007 Mar 30.
Article in English | MEDLINE | ID: mdl-17293159

ABSTRACT

Workshop participants agreed that genotoxicity tests in mammalian cells in vitro produce a remarkably high and unacceptable occurrence of irrelevant positive results (e.g. when compared with rodent carcinogenicity). As reported in several recent reviews, the rate of irrelevant positives (i.e. low specificity) for some studies using in vitro methods (when compared to this "gold standard") means that an increased number of test articles are subjected to additional in vivo genotoxicity testing, in many cases before, e.g. the efficacy (in the case of pharmaceuticals) of the compound has been evaluated. If in vitro tests were more predictive for in vivo genotoxicity and carcinogenicity (i.e. fewer false positives) then there would be a significant reduction in the number of animals used. Beyond animal (or human) carcinogenicity as the "gold standard", it is acknowledged that genotoxicity tests provide much information about cellular behaviour, cell division processes and cellular fate to a (geno)toxic insult. Since the disease impact of these effects is seldom known, and a verification of relevant toxicity is normally also the subject of (sub)chronic animal studies, the prediction of in vivo relevant results from in vitro genotoxicity tests is also important for aspects that may not have a direct impact on carcinogenesis as the ultimate endpoint of concern. In order to address the high rate of in vitro false positive results, a 2-day workshop was held at the European Centre for the Validation of Alternative Methods (ECVAM), Ispra, Italy in April 2006. More than 20 genotoxicity experts from academia, government and industry were invited to review data from the currently available cell systems, to discuss whether there exist cells and test systems that have a reduced tendency to false positive results, to review potential modifications to existing protocols and cell systems that might result in improved specificity, and to review the performance of some new test systems that show promise of improved specificity without sacrificing sensitivity. It was concluded that better guidance on the likely mechanisms resulting in positive results that are not biologically relevant for human health, and how to obtain evidence for those mechanisms, is needed both for practitioners and regulatory reviewers. Participants discussed the fact that cell lines commonly used for genotoxicity testing have a number of deficiencies that may contribute to the high false positive rate. These include, amongst others, lack of normal metabolism leading to reliance on exogenous metabolic activation systems (e.g. Aroclor-induced rat S9), impaired p53 function and altered DNA repair capability. The high concentrations of test chemicals (i.e. 10 mM or 5000 microg/ml, unless precluded by solubility or excessive toxicity) and the high levels of cytotoxicity currently required in mammalian cell genotoxicity tests were discussed as further potential sources of false positive results. Even if the goal is to detect carcinogens with short in vitro tests under more or less acute conditions, it does not seem logical to exceed the capabilities of cellular metabolic turnover, activation and defence processes. The concept of "promiscuous activation" was discussed. For numerous mutagens, the decisive in vivo enzymes are missing in vitro. However, if the substrate concentration is increased sufficiently, some other enzymes (that are unimportant in vivo) may take over the activation-leading to the same or a different active metabolite. Since we often do not use the right enzyme systems for positive controls in vitro, we have to rely on their promiscuous activation, i.e. to use excessive concentrations to get an empirical correlation between genotoxicity and carcinogenicity. A thorough review of published and industry data is urgently needed to determine whether the currently required limit concentration of 10mM or 5000 microg/ml, and high levels of cytotoxicity, are necessary for the detection of in vivo genotoxins and DNA-reactive, mutagenic carcinogens. In addition, various measures of cytotoxicity are currently allowable under OECD test guidelines, but there are few comparative data on whether different measures would result in different maximum concentrations for testing. A detailed comparison of cytotoxicity assessment strategies is needed. An assessment of whether test endpoints can be selected that are not intrinsically associated with cytotoxicity, and therefore are less susceptible to artefacts produced by cytotoxicity, should also be undertaken. There was agreement amongst the workshop participants that cell systems which are p53 and DNA-repair proficient, and have defined Phase 1 and Phase 2 metabolism, covering a broad set of enzyme forms, and used within the context of appropriately set limits of concentration and cytotoxicity, offer the best hope for reduced false positives. Whilst there is some evidence that human lymphocytes are less susceptible to false positives than the current rodent cell lines, other cell systems based on HepG2, TK6 and MCL-5 cells, as well as 3D skin models based on primary human keratinocytes also show some promise. Other human cell lines such as HepaRG, and human stem cells (the target for carcinogenicity) have not been used for genotoxicity investigations and should be considered for evaluation. Genetic engineering is also a valuable tool to incorporate missing enzyme systems into target cells. A collaborative research programme is needed to identify, further develop and evaluate new cell systems with appropriate sensitivity but improved specificity. In order to review current data for selection of appropriate top concentrations, measures and levels of cytotoxicity, metabolism, and to be able to improve existing or validate new assay systems, the participants called for the establishment of an expert group to identify the in vivo genotoxins and DNA-reactive, mutagenic carcinogens that we expect our in vitro genotoxicity assays to detect as well as the non-genotoxins and non-carcinogens we expect them not to detect.


Subject(s)
Mutagenicity Tests , Animals , Cells, Cultured , False Positive Reactions , Humans , Models, Biological , Reagent Kits, Diagnostic , Tissue Culture Techniques
15.
Environ Mol Mutagen ; 46(1): 30-42, 2005 Jul.
Article in English | MEDLINE | ID: mdl-15880423

ABSTRACT

According to the current Organization of Economic Cooperation and Development (OECD) and International Committee on Harmonization (ICH) guidelines for the mammalian erythrocyte micronucleus (MN) test, analysis of peripheral blood reticulocytes (RETs) for the presence of micronuclei can be performed using flow cytometry. The MicroFlow PLUS method (Litron Laboratories, Rochester, NY) for MN analysis by flow cytometry is based on the binding of FITC-labeled antibodies to the CD71 transferrin receptor of immature RETs, on parallel RNA degradation, and on propidium iodide staining of DNA present as micronuclei. The objective of this study was to assess the sensitivity of this flow cytometry method to detect time- and dose-dependent induction of micronuclei in mouse peripheral blood RETs after treatment with nine chemical agents. Five known clastogens, two known aneugens, and two compounds previously reported to be inactive in the mouse bone marrow MN test were evaluated at three dose levels. Multiple blood sampling of the same animal before and at two time points after treatment was conducted. All known mutagens produced a dose-dependent increase in micronucleated reticulocytes (MN-RETs); the compounds previously shown to be inactive in the in vivo MN test were also negative using the present methodology. The highest frequency of MN-RETs was observed at 48 hr after treatment, except for 5-fluorouracil, which had its peak response at 72 hr. The results indicate that micronuclei can be measured by multiple blood sampling of the same animal before and after treatment without altering the sensitivity of the assay. The results confirm that the flow cytometric assessment of MN-RETs in mouse peripheral blood using MicroFlow PLUS is a sensitive method with high analysis throughput, and robust quality control.


Subject(s)
Blood Specimen Collection/methods , Flow Cytometry , Micronuclei, Chromosome-Defective/chemically induced , Mutagens/toxicity , Reticulocytes/drug effects , Animals , Dose-Response Relationship, Drug , Male , Mice , Micronucleus Tests/methods , Reticulocytes/metabolism , Time Factors
16.
Environ Mol Mutagen ; 45(1): 44-55, 2005.
Article in English | MEDLINE | ID: mdl-15605355

ABSTRACT

An interlaboratory study was performed to validate an anti-CD71/flow cytometry-based technique for enumerating micronucleated reticulocytes (MN-RETs) in mouse peripheral blood. These experiments were designed to address International Workshop on Genotoxicity Test Procedures validation criteria by evaluating the degree of correspondence between MN-RET measurements generated by flow cytometry (FCM) with those obtained using traditional microscopy-based methods. In addition to these cross-methods data, flow cytometric MN-RET measurements for each blood sample were performed at two separate sites in order to evaluate the reproducibility of data between laboratories. In these studies, groups of male CD-1 mice were treated with vehicle (saline or vegetable oil), a negative control (saline or vegetable oil), or four dose levels of five known genotoxicants (clastogens: cyclophosphamide, benzo[a]pyrene, 5-fluorouracil, methotrexate; aneugen: vincristine sulfate). Exposure occurred on 3 consecutive days via intraperitoneal injection, and blood samples were obtained approximately 24 hr after the final treatment. MN-RET frequencies were determined for each sample based on the analysis of 2,000 (microscopy) and 20,000 (FCM) reticulocytes. Regardless of the method utilized, each genotoxic agent was observed to cause statistically significant increases in the frequency of MN-RETs, and each response occurred in a dose-dependent manner. Spearman's correlation coefficient (rs) for FCM versus microscopy-based MN-RET measurements (nine experiments, 252 paired measurements) was 0.740, indicating a high degree of correspondence between methods. The rs value for all flow cytometric MN-RET measurements performed at the two independent sites was 0.857 (n = 248), suggesting that the automated method is highly transferable between laboratories. Additionally, the flow cytometric system offered advantages relative to microscopy-based scoring, including a greater number of cells analyzed, much faster analysis times, and a greater degree of objectivity. Collectively, data presented in this report suggest that the overall performance of mouse peripheral blood micronucleus tests is enhanced by the use of the flow cytometric scoring procedure.


Subject(s)
Flow Cytometry/methods , Micronucleus Tests/methods , Reticulocytes , Animals , Antigens, CD , Antigens, Differentiation, B-Lymphocyte , Benzo(a)pyrene/toxicity , Cyclophosphamide/toxicity , Dose-Response Relationship, Drug , Male , Methotrexate/toxicity , Mice , Mutagens/toxicity , Receptors, Transferrin , Vincristine/toxicity
17.
Altern Lab Anim ; 30 Suppl 2: 221-3, 2002 Dec.
Article in English | MEDLINE | ID: mdl-12513680

ABSTRACT

In the pharmaceutical industry, toxicology testing is normally done by preclinical scientists during the Development phase. In the last decade, the implementation of high-throughput screens during the Discovery phase has resulted in an ever-increasing number of lead candidates to be selected for drug development. The low throughput of the conventional safety tests is a bottleneck in the drug-development process. The pharmaceutical industry needs new techniques, down-scaled tests and in vitro alternative test models to determine the absorption, distribution, metabolism, and excretion (ADME) and toxicology profiles of compounds in the late-Discovery phase and/or early in the Development phase. Medium-throughput ADME and toxicity tests will enhance the selection of safer new chemical entities for animals and/or humans. Consequently, this testing strategy will not only reduce the use of resources and the overall development time, but will also result in a substantial decrease in animal use.


Subject(s)
Animal Testing Alternatives , Drug Evaluation, Preclinical , Drugs, Investigational/toxicity , Toxicity Tests , Animals , Drugs, Investigational/pharmacokinetics , European Union , Humans , In Vitro Techniques , Reproducibility of Results , Risk Assessment
19.
Mutat Res Genet Toxicol Environ Mutagen ; 775-776: 55-68, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25435356

ABSTRACT

Positive results in the Ames test correlate well with carcinogenic potential in rodents. This correlation is not perfect because mutations are only one of many stages in tumour development. Also, situations can be envisaged where the mutagenic response may be specific to the bacteria or the test protocol, e.g., bacterial-specific metabolism, exceeding a detoxification threshold, or the induction of oxidative damage to which bacteria may be more sensitive than mammalian cells in vitro or tissues in vivo. Since most chemicals are also tested for genotoxicity in mammalian cells, the pattern of mammalian cell results may help identify whether Ames-positive results predict carcinogenic or in vivo mutagenic activity. A workshop was therefore organised and sponsored by the EU Reference Laboratory for Alternatives to Animal Testing (EURL ECVAM) to investigate this further. Participants presented results from other genotoxicity tests with Ames-positive compounds. Data came from published, regulatory agency, and industry sources. The question was posed whether negative results in mammalian cell tests were associated with absence of carcinogenic or in vivo genotoxic activity despite a positive Ames test. In the limited time available, the presented data were combined and an initial analysis suggested that the association of negative in vitro mammalian cell test results with lack of in vivo genotoxic or carcinogenic activity could have some significance. Possible reasons why a positive Ames test may not be associated with in vivo activity and what additional investigations/tests might contribute to a more robust evaluation were discussed. Because a considerable overlap was identified among the different databases presented, it was recommended that a consolidated database be built, with overlapping chemicals removed, so that a more robust analysis of the predictive capacity for potential carcinogenic and in vivo genotoxic activity could be derived from the patterns of mammalian cell test results obtained for Ames-positive compounds.


Subject(s)
Carcinogens/toxicity , Mutagens/toxicity , Toxicity Tests/trends , Animals , DNA Damage/drug effects , Databases, Factual , Europe , Humans , In Vitro Techniques , Rodentia , Toxicity Tests/methods
20.
Toxicol In Vitro ; 27(4): 1298-311, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23501624

ABSTRACT

Measurement of ocular irritancy is a necessary step in the safety evaluation of both industrial and consumer products. Assessment of the acute eye irritation potential is therefore part of the international regulatory requirements for testing of chemicals. The Bovine Corneal Opacity and Permeability (BCOP) assay is generally accepted as a valid in vitro alternative method to the Draize eye irritation test to detect corrosive and severe eye irritants (category 1), but has not proven sensitive enough to discriminate accurately moderate (category 2A/2B) to mild and non-irritating compounds. In the currently accepted BCOP assay, opacity is determined by the amount of light transmission through the cornea, and permeability is determined by the amount of sodium fluorescein dye that passes through all corneal cell layers. Both measurements are used to assign an In Vitro Irritancy Score (IVIS) for prediction of the in vivo ocular irritation potential of a test substance. Nowadays, opacity is measured by an OP-KIT opacitometer providing a center-weighted reading of light transmission by measuring changes in voltage when the transmission of white light passes through the cornea alters. As a consequence, this may underestimate opacity that develops as spots or heterogeneous opaque areas on the periphery of an isolated cornea. A prototype of a laser light-based opacitometer (PLLBO) allowing better measurement of opacities was developed by Van Goethem et al. (2010). This new device showed improved sensitivity to detect subtle changes in corneal transparency. Furthermore, the new opacitometer allowed the analysis of the complete corneal surface and was able to detect more efficiently opaque spots located along the sides of the excised corneas. A further improved prototype of the PLLBO was constructed in combination with a camera and a speckle noise reducer. Treatment conditions of the corneas in the cornea holders were optimized in order to mimic more the real in vivo situation. A set of test compounds with irritancy potencies especially in the mild and moderate range was tested. The improved LLBO showed some promising features which potentially could improve the usefulness of the BCOP test. Adaptation of cornea holders showed to be of limited value and only restricted to concentrations up to 15% which mimics more test conditions in industry. This 3-year research project was sponsored by the Stavros Niarchos Foundation (Greece).


Subject(s)
Animal Testing Alternatives/methods , Biological Assay/methods , Cornea/drug effects , Irritants/toxicity , Animal Testing Alternatives/instrumentation , Animals , Biological Assay/instrumentation , Cattle , Cornea/metabolism , Corneal Opacity/chemically induced , Equipment Design , In Vitro Techniques , Lasers , Permeability/drug effects , Rabbits
SELECTION OF CITATIONS
SEARCH DETAIL